Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

WEAK-LENSING PEAK FINDING: ESTIMATORS, FILTERS, AND BIASES

Large catalogs of shear-selected peaks have recently become a reality. In order to properly interpret the abundance and properties of these peaks, it is necessary to take into account the effects of the clustering of source galaxies, among themselves and with the lens. In addition, the preferred selection of magnified galaxies in a flux- and size-limited sample leads to fluctuations in the apparent source density that correlate with the lensing field. In this paper, we investigate these issues for two different choices of shear estimators that are commonly in use today: globally normalized and locally normalized estimators. While in principle equivalent, in practice these estimators respond differently to systematic effects such as magnification and cluster member dilution. Furthermore, we find that the answer to the question of which estimator is statistically superior depends on the specific shape of the filter employed for peak finding; suboptimal choices of the estimator+filter combination can result in a suppression of the number of high peaks by orders of magnitude. Magnification and size bias generally act to increase the signal-to-noise {nu} of shear peaks; for high peaks the boost can be as large as {Delta}{nu} {approx} 1-2. Due to the steepness of the peak abundance function, these boosts can result in a significant increase in the observed abundance of shear peaks. A companion paper investigates these same issues within the context of stacked weak-lensing mass estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

A NUMERICAL METHOD FOR THE VISUALIZATION OF THE Fe XIV EMISSION IN THE SOLAR CORONA USING BROADBAND FILTERS

The goal of this article is to demonstrate how the emission from the Fe XIV 530.3 nm coronal emission line, also known as the green line, can be extracted from images taken during total solar eclipses with commercially available color cameras. This concept is technically feasible because Fe XIV is the brightest optical emission line in the inner corona, and because the sensors of these cameras are retrofitted with a standard Bayer mask, namely, a square grid of spectrally broad (about 100 nm) green, blue, and red filters in the ratio of 2:1:1. The technique presented here, and developed for this purpose, yields qualitatively accurate Fe XIV images, as tested by comparing with Fe XIV eclipse images taken with a 0.15 nm narrow-bandpass filter. While this approach cannot replace narrow-bandpass Fe XIV images for quantitative studies of the corona, it provides a simple and affordable tool for studying the morphology of coronal structures emitting preferentially at the peak ionization temperature of Fe XIV, namely, 1.8 Multiplication-Sign 10{sup 6} K.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of plasma properties using an extended Kalman filter with plasma global models

A physically-constrained extended Kalman filter (EKF) is applied to various zero-dimensional global models for the estimation of plasma properties using time-dependent experimental data such as the plasma density or ion flux. The capability of the EKF is demonstrated to estimate unknown system states simultaneously, such as reaction rate coefficients and the absorbed electron input power, which can be difficult, if not impossible, to measure experimentally. Global models accounting for pure argon reactions and argon-oxygen reactions are used in this work to demonstrate the ability of the filter to estimate dynamic and complex systems. Furthermore, the results obtained from the EKF plasma global model illustrate that model-data fusion techniques can be used to estimate plasma properties and processes for time-varying systems, such as pulsed discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Fit Evaluation of N95 Filtering Facepiece Respirators and Coronavirus Inactivation Following Heat Treatment

Abstract Reuse of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use has become common in healthcare facilities due to shortages caused by the COVID-19 pandemic. Here, we report that murine hepatitis coronavirus initially seeded on FFR filter material is inactivated (6 order of magnitude reduction as measured by median tissue culture infective dose, TCID50) after dry heating at 75°C for 30 min. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or 10 heating cycles. Previous studies have reported that the filtration efficiency of FFRs is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to reuse N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also observe that a radiative heat source (e.g. an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investigating heat as a means to recycle FFRs. These differences suggest that while our repeated decontamination cycles do not affect FFR fit, overall wear time and the number of donning/doffing cycles are important factors that likely degrade FFR fit and must be investigated further.

60 APPLIED LIFE SCIENCES↗

Spatial filtering of light by chirped photonic crystals

We propose an efficient method for spatial filtering of light beams by propagating them through two-dimensional (also three dimensional) chirped photonic crystals, i.e., through the photonic structures with fixed transverse lattice period and with the longitudinal lattice period varying along the direction of the beam propagation. We prove the proposed idea by numerically solving the paraxial propagation equation in refraction-index-modulated media and we evaluate the efficiency of the process by harmonic-expansion analysis. The technique can be also applied for filtering (for cleaning) of the packages of atomic waves (Bose condensates), also to improve the directionality of acoustic and mechanical waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increasing future gravitational-wave detectors' sensitivity by means of amplitude filter cavities and quantum entanglement

The future laser interferometric gravitational-wave detectors' sensitivity can be improved using squeezed light. In particular, recently a scheme which uses the optical field with frequency-dependent squeeze factor, prepared by means of a relatively short ({approx}30 m) amplitude filter cavity, was proposed [Thomas Corbitt, Nergis Mavalvala, and Stan Whitcomb, Phys. Rev. D 70, 022002 (2004).]. Here we consider an improved version of this scheme, which allows one to further reduce the quantum noise by exploiting the quantum entanglement between the optical fields at the filter cavity two ports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust Cubature Kalman Filter for Dynamic State Estimation of Synchronous Machines Under Unknown Measurement Noise Statistics

The Kalman-type filtering techniques including cubature Kalman filter (CKF) does not work well in non-Gaussian environments, especially in the presence of outliers. To solve this problem, Huber's M-estimation-based robust CKF (RCKF) is proposed for synchronous machines by combining the Huber's M-estimation theory with the classical CKF, which is capable of coping with the deterioration in performance and discretization of tracking curves when measurement noise statistics deviate from the prior noise statistics. The proposed RCKF algorithm has good adaptability to unknown measurement noise statistics characteristics including non-Gaussian measurement noise and outliers. The simulation results on the WSCC 3-machine 9-bus system and New England 16-machine 68-bus system verify the effectiveness of the proposed method and its advantage over the classical CKF.

42 ENGINEERING↗

A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e{sup -} to 100000 e{sup -}, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Channel Estimation for Filter Bank Multicarrier Systems in Low SNR Environments

Channel estimation techniques are crucial for reliable communications. This paper is concerned with channel estimation in a filter bank multicarrier spread spectrum (FBMCSS) system. We explore two channel estimator options: (i) a method that makes use of a periodic preamble and mimics the channel estimation techniques that are widely used in OFDM-based systems; and (ii) a method that stays within the traditional realm of filter bank signal processing. For the case where the channel noise is white, both methods are analyzed in detail and their performance is compared against their respective Cramer-Rao Lower Bounds (CRLB). Advantages and disadvantages of the two methods under different channel conditions are given to provide insight to the reader as to when one will outperform the other.

99 GENERAL AND MISCELLANEOUS↗

Multicode Signaling in a Filter Bank Multicarrier Spread Spectrum System and Its Application to HF Communications

The use of filter banks for implementing multicarrier spread spectrum systems leads to a class of effective waveforms that are highly resilient to partial-band interferers. Such waveforms can be also designed to keep the peak-to-average power ratio (PAPR) of the resulting signal at a minimum level. The use of multiple spreading gain vectors (known as multicodes), on the other hand, is an effective method for increasing the data rate in spread spectrum systems, in general. This paper presents a detailed analysis of a class of filter bank multicarrier spread spectrum (FBMC-SS) waveforms and demonstrates an effective receiver implementation of them when multicodes are applied. Application of the developed multicode waveform for communications over high-frequency (HF) skywave channels is also explored, and the benefits that it provides are studied both numerically, through computer simulations, and experimentally, by examining the receivers performance over a variety of skywave links.

42 ENGINEERING↗

Adaptation of the chevron-notch beam fracture toughness method to specimens harvested from diesel particulate filters

In this paper, the apparent fracture toughness of a porous cordierite ceramic was estimated using a large specimen whose geometry was inspired by the ASTM-C1421-standardized chevron-notch beam. In this paper, using the same combination of experiment and analysis used to develop the standardized chevron-notch test for small, monolithic ceramic bend bars, an apparent fracture toughness of 0.6 and 0.9 MPa√m were estimated for an unaged and aged cordierite diesel particulate filter structure, respectively. Finally, the effectiveness and simplicity of this adapted specimen geometry and test method lends itself to the evaluation of (macroscopic) apparent fracture toughness of an entire porous-ceramic, diesel particulate filter structure.

36 MATERIALS SCIENCE↗

Mechanical characterization of diesel particulate filter (DPF) substrates

Test procedures for the mechanical evaluation of diesel particulate filter (DPF) substrate materials have been developed and applied for the characterization of porous cordierite under ambient conditions. Specifically the double-torsion test method was employed to characterize fracture toughness and slow crack behavior while resonant ultrasound spectroscopy (RUS) was used to determine the elastic properties of the substrate walls. A dry grinding procedure was developed to fabricate test specimens for these tests. The fracture behavior of porous cordierite was related to the pore structure inside the filter wall. Implications of the test results on the mechanical reliability of DPFs are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

Photon beam quality variations of a flattening filter free linear accelerator

Purpose: Recently, there has been an increasing interest in operating conventional linear accelerators without a flattening filter. The aim of this study was to determine beam quality variations as a function of off-axis ray angle for unflattened beams. In addition, a comparison was made with the off-axis energy variation in flattened beams. Methods: Two Elekta Precise linear accelerators were modified in order to enable radiation delivery with and without the flattening filter in the beam line. At the Medical University Vienna (Vienna, Austria), half value layer (HVL) measurements were performed for 6 and 10 MV with an in-house developed device that can be easily mounted on the gantry. At St. Luke's Hospital (Dublin, Ireland), measurements were performed at 6 MV in narrow beam geometry with the gantry tilted around 270 deg. with pinhole collimators, an attenuator, and the chamber positioned on the table. All attenuation measurements were performed with ionization chambers and a buildup cap (2 mm brass) or a PMMA mini phantom (diameter 3 cm, measurement depth 2.5 cm). Results: For flattened 6 and 10 MV photon beams from the Elekta linac the relative HVL({theta}) varies by about 11% for an off-axis ray angle {theta}=10 deg. These results agree within {+-}2% with a previously proposed generic off-axis energy correction. For unflattened beams, the variation was less than 5% in the whole range of off-axis ray angles up to 10 deg. The difference in relative HVL data was less than 1% for unflattened beams at 6 and 10 MV. Conclusions: Off-axis energy variation is rather small in unflattened beams and less than half the one for flattened beams. Thus, ignoring the effect of off-axis energy variation for dose calculations in unflattened beams can be clinically justified.

43 PARTICLE ACCELERATORS↗

Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis

Purpose: To compare volumetric modulated arc therapy with flattening filter free (FFF) and flattening filter (FF) beams in patients with hepatic metastases subject to hypofractionated radiotherapy (RT). Methods: A planning study on 13 virtual lesions of increasing volume was performed. Two single arc plans were optimized with the RapidArc technique using either FFF or FF beams. A second planning study was performed on ten patients treated for liver metastases to validate conclusions. In all cases, a dose of 75 Gy in 3 fractions was prescribed to the planning target volume (PTV) and plans were evaluated in terms of coverage, homogeneity, conformity, mean dose to healthy liver and to healthy tissue. For each parameter, results were expressed in relative terms as the percentage ratio between FFF and FF data. Results: In terms of PTV coverage, conformity index favored FFF for targets of intermediate size while FF resulted more suitable for small (<100 cm{sup 3}) and large (>300 cm{sup 3}) targets. Plans optimized with FFF beams resulted in increased sparing of healthy tissue in {approx_equal}85% of cases. Despite the qualitative results, no statistically significant differences were found between FFF and FF results. Plans optimized with un-flattened beams resulted in higher average MU/Gy than plans with FF beams. A remarkable and significant difference was observed in the beam-on time (BOT) needed to deliver plans. The BOT for FF plans was 8.2 {+-} 1.0 min; for FFF plans BOT was 2.2 {+-} 0.2 min. Conclusions: RapidArc plans optimized using FFF were dosimetrically equivalent to those optimized using FF beams, showing the feasibility of SBRT treatments with FFF beams. Some improvement in healthy tissue sparing was observed when using the FFF modality due to the different beam's profile. The main advantage was a considerable reduction of beam-on time, relevant for SBRT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Filtered backprojection proton CT reconstruction along most likely paths

Purpose: Proton CT (pCT) has the potential to accurately measure the electron density map of tissues at low doses but the spatial resolution is prohibitive if the curved paths of protons in matter is not accounted for. The authors propose to account for an estimate of the most likely path of protons in a filtered backprojection (FBP) reconstruction algorithm. Methods: The energy loss of protons is first binned in several proton radiographs at different distances to the proton source to exploit the depth-dependency of the estimate of the most likely path. This process is named the distance-driven binning. A voxel-specific backprojection is then used to select the adequate radiograph in the distance-driven binning in order to propagate in the pCT image the best achievable spatial resolution in proton radiographs. The improvement in spatial resolution is demonstrated using Monte Carlo simulations of resolution phantoms. Results: The spatial resolution in the distance-driven binning depended on the distance of the objects from the source and was optimal in the binned radiograph corresponding to that distance. The spatial resolution in the reconstructed pCT images decreased with the depth in the scanned object but it was always better than previous FBP algorithms assuming straight line paths. In a water cylinder with 20 cm diameter, the observed range of spatial resolutions was 0.7 - 1.6 mm compared to 1.0 - 2.4 mm at best with a straight line path assumption. The improvement was strongly enhanced in shorter 200 Degree-Sign scans. Conclusions: Improved spatial resolution was obtained in pCT images with filtered backprojection reconstruction using most likely path estimates of protons. The improvement in spatial resolution combined with the practicality of FBP algorithms compared to iterative reconstruction algorithms makes this new algorithm a candidate of choice for clinical pCT.

60 APPLIED LIFE SCIENCES↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

The effect of flattening filter free delivery on endothelial dose enhancement with gold nanoparticles

Purpose: The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. Methods: Tumor endothelial cells are modeled as slabs measuring 10 Multiplication-Sign 10 Multiplication-Sign 2 {mu}m. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. 6 MV photon beams with and without the flattening filter are investigated for different field sizes, depths in material and beam modulation. The incident photon energy spectra for each configuration is generated using EGSnrc. The dose enhancement in the tumor endothelial cell is found using an analytical calculation. The endothelial dose enhancement factor is defined to be the ratio of the dose deposited with and without AuNPs. Results: It is found that clinical beam parameters may be chosen to maximize the effect of gold nanoparticles during radiotherapy. This effect is further amplified {approx}20% by the removal of the flattening filter. Modulation of the clinical beam with the multileaf collimator tends to decrease the proportion of low energy photons, therefore providing less enhancement than the corresponding open field. Conclusions: The results of this work predict a dose enhancement to tumor blood vessel endothelial cells using conventional therapeutic (MV) x-rays and quantify the relative change in enhancement with treatment depth and field size.

60 APPLIED LIFE SCIENCES↗