Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Incorporation of 40 CFR 192 as an ARAR when Implementing MARSSIM (USACE Input to the MARSSIM Committee for MARSSIM Revision 2) - 18526

One example special case for Final Status Surveys (FSSs) occurs at Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA) sites at which the radioactive materials are from the processing of uranium or thorium ores for their source material content. At these sites, EPA's Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings, in 40 CFR 192, are applicable. Also, 40 CFR 192 may be invoked at non-UMTRCA sites through the CERCLA as an Applicable or Relevant and Appropriate Requirement (ARAR) due to the presence of radium (Ra)-226 or Ra-228, even though the source of residual radioactive material was not a uranium or thorium mill tailings facility. However, the regulatory requirements in these standards infringe on some of the recommendations in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). Specifically, the soil cleanup standards for Ra-226 or Ra-228 are specified as averages over an area of 100 square meters (m{sup 2}). Note that in the 40 CFR 192 rulemaking, an averaging area of 100 m{sup 2} was used as a reasonable footprint for a home. One goal of the 40 CFR 192 standards was to protect future homes from indoor radon, and the specified averaging area was a component implemented for the protection of health. In addition, 40 CFR 192 is silent regarding elevated measurement criteria (EMC)-type requirements for smaller areas of elevated radioactive material within the 100-m{sup 2} footprint. At UMTRCA sites and CERCLA sites where UMTRCA is an ARAR, the following approach for FSSs is acceptable: - Survey units (SUs) may be classified, as appropriate, and survey activities may be adjusted accordingly for Class 1, Class 2, or Class 3 SUs. - Class 1 soil SUs should provide for evaluation of portions that are no greater than 100 m{sup 2} in size, consistent with the 40 CFR 192 standards. - Class 2 and 3 soil SUs are not expected to exceed the 40 CFR 192 soil cleanup standard, so they do not require evaluation of portions that are no greater than 100 m{sup 2} in size. - Compliance with 40 CFR 192 can be demonstrated through analysis of soil samples or composite soil samples from each SU, in conjunction with gamma radiation scanning or in situ gamma radiation measurements of each SU. When appropriate, these gamma radiation scans or in situ measurements correlated to soil sampling may be used in place of soil sampling. - By demonstrating that the average over 100 m{sup 2} meets the 40 CFR 192 soil cleanup standard, the EMC criteria for small elevated areas of activity are not required for the purposes of MARSSIM, but may be developed. These minor modifications to the standard MARSSIM radiological survey approach are acceptable for UMTRCA sites or CERCLA sites where UMTRCA is an ARAR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 31: US DOE Featured Site: 30 Years of Environmental Management at the Idaho National Laboratory (1/5)

This panel highlighted the cleanup challenges and successes at the Idaho site, including the landmark Idaho Settlement Agreement, effective collaborative regulatory strategies, worker involvement, stakeholder involvement, and looking ahead. 2019 marks 30 years since the start of the DOE-EM mission at the Idaho National Laboratory Site. This panel focused on the cleanup successes and challenges at the Idaho National Laboratory (INL) Site (Idaho, USA) over the last 30 years. The INL was added to the National Priorities List of Superfund Sites in 1989. Since that listing, the INL has been focused on meeting the cleanup milestones outlined in the Site Treatment Plan, 1991 Federal Facility Agreement and Consent Order, 1995 Idaho Settlement Agreement, and other agreements between the Department of Energy (DOE) and State of Idaho. Presentation proposed: 30 Years of Cleanup at Idaho National Laboratory Site (Nolan Jensen, US DOE - Idaho Operations Office - Idaho Cleanup Project (USA), Kliss McNeel, Fluor Idaho (USA), Mark Clough, Idaho Department of Environmental Quality (USA), Darrell Early, Office of the Idaho Attorney General (USA), Rebecca Casper, City of Idaho Falls (USA))

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generating Emissions Inventory for Carbon Capture and Storage Analysis for Carbon-Intensive Industrial Sectors

Decarbonizing the industrial sector is critical to achieve carbon dioxide (CO2) emissions reductions goals of the Biden Administration. Currently available decarbonization options include electrification, fuel switching to zero carbon fuels like green hydrogen (H2) and carbon capture and storage (CCS). Application of post-combustion carbon capture (PCCC) technology in the power sector, as well as research at the U.S. Department of Energy's Fossil Energy and Carbon Management (FECM) Office has shown that its application in the industrial sector could have co-benefits in the form of emissions reductions of non-CO2 regulated pollutants. For example, solvent based PCCC systems require pre-conditioning of flue gas to remove sulfur and particulate matter (PM) upstream of the CO2 absorber. However, there is a lack of understanding about the type of non-CO2 pollutants which can be captured and the amount of reduction possible. PCCC application differs across industrial sectors as it depends on the availability of decarbonization options, characteristics of industrial processes and the amount and composition of pollutant flows. Certain facilities can also have multiple effluent flows with or without a CO2 stream. As such, understanding industrial processes and their effluent flows in detail is required to quantify the co-benefits opportunities presented by PCCC. Considering this requirement, the goal of this analysis is to develop a high-resolution inventory of effluent flows from facilities of 8 industrial sectors in the U.S. These industrial sectors - ethanol, ammonia, cement, steel, natural gas processing, hydrogen, petroleum refining and wood and pulp products - have carbon-intensive effluent flows, and thus are prime candidates for PCCC applications. In this study, we map the composition of pollutant flow from flue stacks across the identified facilities. Using data available in three Environmental Protection Agency (EPA) databases - the Green House Gas Reporting Program (GHGRP), the National Emissions Inventory (NEI) and the Toxic Release Inventory (TRI), we create a combined inventory which lists the type, amount, and concentration of pollutant flows. Using total weight of the pollutant flow back calculated from observed data for CO2 concentrations in flue gas for individual sectors, we calculate the concentration of each pollutant in the flue gas stream. Thus, the resultant emissions inventory includes the following details for each facility in the sector: facility-level and if possible, process-level pollutant flows, concentrations of pollutants in the flue gas, and geographical coordinates of the facilities. A detailed statistical analysis and summary allows us to search for erroneous data and remove them from the final inventory. The generation of the inventory is achieved using a python-based framework which can recreate this inventory for other industrial sectors as well as using newer releases of emission inventories from EPA. The statistical analysis performed on the inventory is also calibrated and automated to identify outliers efficiently.

air pollutants↗

Multi-functional Sorbent Technology (MUST) for the Recovery/Removal of Critical/Heavy Metals from Fossil-Related Wastewater

A collection of remediation and recovery technologies like those predicated on photocatalytic-, electric-, chemical-, membrane-, and adsorptive-based processes currently exists in different stages of development or deployment between these methods of water management. Among these technologies, solid sorbent processes embody an optimal balance between cost-effectiveness, environmental friendliness, and technological maturity. The U.S. Department of Energy’s National Energy Technology Laboratory developed a suit of cross-linked, functionalized silica sorbents tailored to eliminate the most toxic metals regulated by the U.S. Environmental Protection Agency (EPA); critical metals identified by the U.S. Geological Survey (USGS); and harmful organics like the infamous perfluoroalkyl and polyfluoroalkyl substances (PFAS). An array of laboratory and field tests proved that the MUST sorbents removed ppb-level lead from drinking water, selenium from FGD wastewater below EPA limits, aqueous dyes and PFAS; and fractionated low ppm-level critical metals (CM) from AMD and simulated produced water. Proof-of-concept for commercial CM recovery was verified through obtaining milligram-quantities of purified Al solids from a sorbent multi-bed AMD field-site test. Commercial efficacy was further supported by achieving purified fractions of adsorbed Mn upon treating both the AMD and synthetic produced water with the laboratory multi-bed test unit.

Wilfong, Walter C.↗

Risk Considerations of Transitioning CO2-EOR Field to CO2 storage Field: Case Study

In the United States (U.S.), carbon dioxide (CO2) injection wells at EOR sites are currently regulated as Class II wells under the U.S. Environmental Protection Agency’s (EPA) Underground Injection Control (UIC) program while dedicated geological CO2 storage (GCS) wells are considered Class VI wells. A CO2-EOR facility considering a transitioning from tertiary oil recovery to injecting CO2 for the primary purpose of long-term storage is required to obtain a Class VI permit where this transition poses an increased risk to underground sources of drinking water. This study considers how transitioning operations from CO2-EOR to storage can impact reservoir plume and pressure transient in the storage envelope, and how these changes could impact area of review and potential unwanted fluid migration. We developed a case study to assess subsurface response and leakage risks associated with a representative, hypothetical operation in a carbonate reservoir. This reservoir transitions from tertiary hydrocarbon recovery to dedicated GCS. Reservoir simulations were run for a set of credible CO2-EOR scenarios to estimate distributions of fluids phases and pressures throughout the model domain after CO2 flooding as well as forecasting the behavior of the reservoir after the transition to a dedicated storage phase. The evolutions from all simulated scenarios were used as the basis for leakage risk quantification using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM) with a novel reduced-order model to estimate time-dependent leakage of CO2, brine, and hydrocarbon fluids through potentially leaky wells. Results include a description of reservoir response, an estimate of the areal extent that could potentially be impacted by leakage to underground sources of drinking water, and estimates of the magnitude of potential leakage. Considerations for dedicated storage injection well selection, injectivity, and injection scheme performance and potential leakage risk are presented, with implications for risk assessment of well transition discussed. This study presents a risk-based workflow for the Class II to Class VI well transition. Integrating credible numerical simulation of viable CO2-EOR to dedicated CO2 storage with quantitative risk assessment tools, such as the NRAP-Open-IAM, will provide a valuable means to devise operational scenarios and inform decision-making related to storage benefit, leakage risk, and liability. Presented at the SPE/AAPG/SEG Carbon Capture Utilization and Storage Conference in Houston, TX, March 11-13, 2024.

Liu, Guoxiang↗

Human Health Risk Assessment for Improper Landfill Disposal of End-of-Life CdTe Modules

The present work is a continuation of the 2020 IEA PVPS Task 12 Human Health Risk Assessment Methods for PV Part 3: Module Disposal Risks. The 2020 report performed a human health risk assessment (HHRA) for disposal of a cadmium telluride (CdTe) PV module in an unlined landfill, focusing solely on risks from cadmium. This study extends the 2020 HHRA on CdTe PV, analyzing eleven constituent elements: Cd, Se, Te, Cu, Si, Cr(III), Mo, Sn, Zn, Ni, and Al. The present HHRA was performed through two methods: utilization of the U.S. Environmental Protection Agency's (USEPA) Delisting Risk Assessment Software (DRAS V.4.0) on eight exposure pathways for cancer risk and non-cancer hazards; and comparison of exposure point concentrations to federal standards for groundwater, surface water, air, and soil exposure pathways. Cancer risks and non-cancer hazards posed by elemental leaching through all evaluated exposure pathways, using both methods, were found to be several orders of magnitude below USEPA health-protective thresholds. Cadmium exhibited both the highest risks and lowest uncertainty considering data availability on chemical content, leachate, and federal screening levels.

CdTe↗

Transportation Electrification Impact Study (TEIS)

Recent U.S. Environmental Protection Agency (EPA) notices of proposed rulemakings for GHG emissions standards for light-, medium-, and heavy-duty on-road vehicles would accelerate ongoing advancements already happening in the industry because of private investment, consumer demand, state-level policies, and federal incentives. As the EPA finalizes these regulations, questions persist regarding the cost of the requisite charging infrastructure and associated upgrades to the nation's electric grid. With support from the U.S. Department of Energy, U.S. Joint Office of Energy and Transportation, and the EPA, a multidisciplinary team conducted a Multi-State Transportation Electrification Impact Study that quantitatively assesses the incremental investment necessary to enable the levels of vehicle electrification expected to be induced by pending EPA regulations and to estimate the potential value of deferred investments in electric distribution infrastructure stemming from proactive vehicle-grid integration planning and deployment. This study finds the simulated incremental capital cost of charging infrastructure (including grid upgrades) to be at least 2.5 times smaller than the lifetime net benefits of vehicle electrification (including fuel savings but excluding the value of avoided emissions). Additionally, the incremental distribution grid upgrade cost of the EPA Action-Unmanaged scenario was found to be approximately 3% of existing utility distribution system investments (on an annual basis). Finally, the potential for managed charging to defer distribution grid upgrades was found to be significant with costs found to decrease from $2.3 billion to an incremental cost of $1 billion across five states in the Action-Managed scenario (relative to the No Action-Unmanaged scenario).

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

SAF Grand Challenge: October 2021 – September 2024 Progress Report Fact Sheet

An interagency team led by the U.S. Department of Energy (DOE), U.S. Department of Agriculture (USDA), U.S. Department of Transportation (DOT), and other federal agencies including the U.S. Department of Defense, U.S. Environmental Protection Agency, National Aeronautics and Space Administration, and Commercial Aviation Alternative Fuels Initiative have made important progress on accelerating acceptance and growth of sustainable aviation fuel (SAF) as a primary strategy in aviation decarbonization. The progress made by these federal agencies supports the interagency SAF Grand Challenge, including new funding opportunities and initiatives aligned with the SAF Grand Challenge Roadmap; providing expertise and technical assistance to industry; increasing interagency collaboration; and providing data, modeling, and analysis to decision makers.

Sustainable Aviation Fuel Aviation SAF↗

Metal oxide impregnated conformal coatings for ionizing radiation shielding

Conformal coatings provide environmental protection for sensitive military electronics. Preliminary MCNP™ modeling of metal oxide impregnated acrylic conformal coatings indicates an effective shield for gammas below 10 keV and a reduction in neutron displacement damage to Si-based electronics across the Watt spectrum. This work provides data which can allow an optimal overall shielding worth per total weight to eventually be evaluated.

Hayes, Robert Bruce↗

Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites

In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.

03 NATURAL GAS↗

Affinity and Treatment of LDR Organics in Low Activity Waste by Cementitious Materials – 26109

The physiochemical interactions between organic contaminants, minerals, and polymer additives in grout/cementitious materials are being identified. This research supports a proposed Resource Conservation and Recovery Act (RCRA) treatment variance relevant to the Land Disposal Restriction (LDR) organics present in Hanford tank waste. It provides the technical basis to address the aspects documented by the Environmental Protection Agency in a draft memo necessary to establish that organics can be immobilized/stabilized in a cementitious matrix. The organic species may interact with cementitious minerals, including slag, fly ash, cement, and other components/dopants like activated carbon. A list of 132 reasonably expected LDR organics associated with Hanford tank waste (RPP-RPT-63493, Rev 1a) was screened by functional groups, octanol-water partitioning coefficients, and detection frequency in Hanford tank waste samples. A subset of 15 compounds spanning the identified properties was tested using sorption and leachate tests. These compounds were subjected to traditional batch sorption tests and leaching tests on/from Cast Stone cementitious material with and without activated carbon (a potential organic adsorption additive). The interactions between organic compounds were observed in traditional batch sorption and modified TCLP leachate tests for surrogate Cast Stone material with and without activated carbon addition. Specifically, phthalic acid (negatively charged) and 4-chloroaniline (polar) sorbed strongly to unmodified Cast Stone, while a group of three phenolic compounds (2,4,6-Trichlorophenol, Pentachlorophenol, o-Cresol) sorbed to and were retained by Cast Stone with a 1% activated carbon amendment. Mixtures of these compounds demonstrated visible retention of the organics within the matrix with a quantifiable affinity of the organics to the cement. This novel testing supports the notion that organics within Hanford tank waste would be retained onto the cement phase with the addition of simple materials easily added to the formulation as part of the treatment process. To further provide additional support to this claim, models employing Flory-Huggins theory in conjunction with macromolecular and organic molecule solubility parameters and species activity coefficients are being utilized to better understand these interactions. Within this context, Van Krevelen (VK) and Hansen organic and polymer solubility parameters were used to inform the Flory-Huggins interaction parameter, allowing for a quantifiable method of evaluating polymer-solvent compatibility and, by extension, interactions with proposed binding additives (e.g., activated carbon). These models and measurement should test the hypothesis for our systems understanding and applicability of Flory-Huggins theory, and whether the prediction of organics in the polymer phase versus the aqueous phase can be confidently made using this strategy. The estimation of the organic molecular activity coefficient in these high salt-saturated aqueous systems is another factor that will be assessed. This project aims to predict and understand complicated organic interactions in these heterogenous systems, guiding optimal treatment and stabilization methodologies.

Jolin, Will [Savannah River National Laboratory (S↗

RH-TRU Waste Streams: HFDA Crucibles Create New Complex Waste Stream

This project focuses on the removal of the Hot Fuel Dissolution Apparatus (HFDA) crucibles from the Hot Fuel Examination Facility’s (HFEF) hot cells to create space for upcoming projects. The project team has created a crucible and pyro-salt non-debris waste stream that can be disposed of at Waste Isolation Pilot Plant (WIPP). Chemical Compatibility Examinations (CCEs) must be performed on candidate waste by reviewing the types of chemicals used in the experiments, information found in INL Process Knowledge Summary Reports (PKSRs), and Environmental Protection Agency guides on chemical compatibility. The CCEs identify which chemicals can be safely combined to ensure adverse reactions do not occur in the waste packages. The CCEs are then used to update the PKSR, Basis of Knowledge, and Acceptable Knowledge documents and demonstrate compliance with the WIPP Waste Acceptance Criteria. Once documents are finalized, they are reviewed and approved by the WIPP Central Characterization Project (CCP) to ensure proper waste stream characterization. After the documents are approved, the crucibles can be packaged and shipped to the Idaho Nuclear Technical and Engineering Center for storage awaiting certification. CCP will certify the waste using the approved documents and a series of confirmatory testing before being shipped and disposed in WIPP’s deep geological repository. Currently, the CCE is in progress and the PKSRs are being updated.

Basis of Knowledge↗

IMPROVEMENTS IN CONTAINER MANAGEMENT OF TRANSURANIC (TRU) AND LOW LEVEL RADIOACTIVE WASTE STORED AT THE CENTRAL WASTE COMPLEX (CWC) AT HANFORD

The Central Waste Complex (CWC) is the interim storage facility for Resource Conservation & Recovery Act (RCRA) mixed waste, transuranic waste, transuranic mixed waste, low-level and low-level mixed radioactive waste at the Department of Energy's (DOE'S) Hanford Site. The majority of the waste stored at the facility is retrieved from the low-level burial grounds in the 200 West Area at the Site, with minor quantities of newly generated waste from on-site and off-site waste generators. The CWC comprises 18 storage buildings that house 13,000 containers. Each waste container within the facility is scanned into its location by building, module, tier and position and the information is stored in a site-wide database. As waste is retrieved from the burial grounds, a preliminary non-destructive assay is performed to determine if the waste is transuranic (TRU) or low-level waste (LLW) and subsequently shipped to the CWC. In general, the TRU and LLW waste containers are stored in separate locations within the CWC, but the final disposition of each waste container is not known upon receipt. The final disposition of each waste container is determined by the appropriate program as process knowledge is applied and characterization data becomes available. Waste containers are stored within the CWC based on their physical chemical and radiological hazards. Further segregation within each building is done by container size (55-gallon, 85-gallon, Standard Waste Box) and waste stream. Due to this waste storage scheme, assembling waste containers for shipment out of the CWC has been time consuming and labor intensive. Qualitatively, the ratio of containers moved to containers in the outgoing shipment has been excessively high, which correlates to additional worker exposure, shipment delays, and operational inefficiencies. These inefficiencies impacted the LLW Program's ability to meet commitments established by the Tri-Party Agreement, an agreement between the State of Washington, the Department of Energy, and the Environmental Protection Agency. These commitments require waste containers to be shipped off site for disposal and/or treatment within a certain time frame. Because the program was struggling to meet production demands, the Production and Planning group was tasked with developing a method to assist the LLW Program in fulfilling its requirements. Using existing databases for container management, a single electronic spreadsheet was created to visually map every waste container within the CWC. The file displays the exact location (e.g., building, module, tier, position) of each container in a format that replicates the actual layout in the facility. In addition, each container was placed into a queue defined by the LLW and TRU waste management programs. The queues were developed based on characterization requirements, treatment type and location, and potential final disposition. This visual aid allows the user to select containers from similar queues and view their location within the facility. The user selects containers in a centralized location, rather than random locations, to expedite shipments out of the facility. This increases efficiency for generating the shipments, as well as decreasing worker exposure and container handling time when gathering containers for shipment by reducing movements of waste container. As the containers are collected for shipment, the remaining containers are segregated by queue, which further reduces future container movements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OPTIMIZING RADIOLOGICAL MONITOR SITING OVER THE CONTINENTAL U.S.

The US Environmental Protection Agency (EPA) is installing a network of sensors in the US to monitor background radiation and elevated radiation levels expected from a possible nuclear incident. The network (RadNet) of 180 fixed sensors is intended to provide a basic estimate of the radiation level throughout the US and enhanced accuracy near population centers. This report discusses one of the objective methods for locating these monitors based on criteria outlined by the EPA. The analysis employs a representative climatology of incident scenarios that includes 50 release locations, four seasons and four times of the day. This climatology was calculated from 5,600 simulations generated with NOAA-ARL's HYSPLIT Lagrangian trajectory model. The method treats the release plumes as targets and monitors are located to maximize the number of plumes detected with the network. Weighting schemes based on detection only, dose-weighted detection and population-dose weighted detection were evaluated. The result shows that most of the monitors are located around the population centers, as expected. However, there are monitors quite uniformly distributed around the less populated areas. The monitors at the populated areas will provide early warning to protect the general public, and the monitors spread across the country will provide valuable data for modelers to estimate the extent and the transport of the radioactive contamination.

61 RADIATION PROTECTION AND DOSIMETRY↗

TANK FARM RETRIEVAL LESSONS LEARNED AT THE HANFORD SITE

One of the environmental remediation challenges facing the nation is the retrieval and permanent disposal of approximately 90 million gallons of radioactive waste stored in underground tanks at the U. S. Department of Energy (DOE) facilities. The Hanford Site is located in southeastern Washington State and stores roughly 60 percent of this waste. An estimated 53 million gallons of high-level, transuranic, and low-level radioactive waste is stored underground in 149 single-shell tanks (SSTs) and 28 newer double-shell tanks (DSTs) at the Hanford Site. These SSTs range in size from 55,000 gallons to 1,000,000 gallon capacity. Approximately 30 million gallons of this waste is stored in SSTs. The SSTs were constructed between 1943 and 1964 and all have exceeded the nominal 20-year design life. Sixty-seven SSTs are known or suspected to have leaked an estimated 1,000,000 gallons of waste to the surrounding soil. The risk of additional SST leakage has been greatly reduced by removing more than 3 million gallons of interstitial liquids and supernatant and transferring this waste to the DST system. Retrieval of SST saltcake and sludge waste is underway to further reduce risks and stage feed materials for the Hanford Site Waste Treatment Plant. Regulatory requirements for SST waste retrieval and tank farm closure are established in the Hanford Federal Facility Agreement and Consent Order (HFFACO), better known as the TriParty Agreement, or TPA. The HFFACO was signed by the DOE, the State of Washington Department of Ecology (Ecology), and U. S. Environmental Protection Agency (EPA) and requires retrieval of as much waste as technically possible, with waste residues not to exceed 360 fe in 530,000 gallon or larger tanks; 30 fe in 55,000 gallon or smaller tanks; or the limit of waste retrieval technology, whichever is less. If residual waste volume requirements cannot be achieved, then HFFACO Appendix H provisions can be invoked to request Ecology and EPA approval of an exception to the waste retrieval criteria for a specific tank. Tank waste retrieval has been conducted at the Hanford Site over the last few decades using a method referred to as Past Practice Hydraulic Sluicing. Past Practice Hydraulic Sluicing employs large volumes of DST supernatant and water to dislodge, dissolve, mobilize, and retrieve tank waste. Concern over the leak integrity of SSTs resulted in the need for tank waste retrieval methods capable of using smaller volumes of liquid in a more controlled manner.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRITIUM MOVEMENT AND ACCUMULATION IN THE NGNP SYSTEM INTERFACE AND HYDROGEN PLANT

Tritium movement and accumulation in the Next Generation Nuclear Plant (NGNP) employing either a high-temperature electrolysis (HTE) process or a thermochemical water-splitting Sulfur-Iodine (SI) process to produce hydrogen is estimated by a numerical code, THYTAN, as a function of design, operational and material parameters. Estimated tritium concentrations in the hydrogen product and in the process chemicals of the hydrogen plant using the HTE process are slightly higher than the limit in drinking water defined by the U.S. Environmental Protection Agency (EPA) and in effluent at the boundary of an unrestricted area defined by the U.S. Nuclear Regulatory Commission (NRC), respectively. Estimated tritium concentrations in the NGNP using the SI hydrogen production process are significantly higher, and are largely affected by undetermined parameters (i.e., tritium permeability of heat exchanger materials, hydrogen concentration in the helium energy transport fluids, equilibrium constant of the tritium isotope exchange reaction between HT and H{sub 2}SO{sub 4}). These parameters should be measured or estimated in the near future, as should the tritium generation and release rate from the NGNP nuclear reactor core. Decreasing the tritium permeation rate between the primary and secondary heat transport circuits is an effective measure to decrease the tritium concentrations in the hydrogen product, hydrogen plant process chemicals, and the tertiary heat transport fluid.

08 HYDROGEN↗

WaterSense Program: Methodology for National Water Savings Analysis Model Indoor Residential Water Use

The U.S. Environmental Protection Agency (EPA) influences the market for plumbing fixtures and fittings by encouraging consumers to purchase products that carry the WaterSense label, which certifies those products as performing at low flow rates compared to unlabeled fixtures and fittings. As consumers decide to purchase water-efficient products, water consumption will decline nationwide. Decreased water consumption should prolong the operating life of water and wastewater treatment facilities.This report describes the method used to calculate national water savings attributable to EPA?s WaterSense program. A Microsoft Excel spreadsheet model, the National Water Savings (NWS) analysis model, accompanies this methodology report. Version 1.0 of the NWS model evaluates indoor residential water consumption. Two additional documents, a Users? Guide to the spreadsheet model and an Impacts Report, accompany the NWS model and this methodology document. Altogether, these four documents represent Phase One of this project. The Users? Guide leads policy makers through the spreadsheet options available for projecting the water savings that result from various policy scenarios. The Impacts Report shows national water savings that will result from differing degrees of market saturation of high-efficiency water-using products.This detailed methodology report describes the NWS analysis model, which examines the effects of WaterSense by tracking the shipments of products that WaterSense has designated as water-efficient. The model estimates market penetration of products that carry the WaterSense label. Market penetration is calculated for both existing and new construction. The NWS model estimates savings based on an accounting analysis of water-using products and of building stock. Estimates of future national water savings will help policy makers further direct the focus of WaterSense and calculate stakeholder impacts from the program.Calculating the total gallons of water the WaterSense program saves nationwide involves integrating two components, or modules, of the NWS model. Module 1 calculates the baseline national water consumption of typical fixtures, fittings, and appliances prior to the program (as described in Section 2.0 of this report). Module 2 develops trends in efficiency for water-using products both in the business-as-usual case and as a result of the program (Section 3.0). The NWS model combines the two modules to calculate total gallons saved by the WaterSense program (Section 4.0). Figure 1 illustrates the modules and the process involved in modeling for the NWS model analysis.The output of the NWS model provides the base case for each end use, as well as a prediction of total residential indoor water consumption during the next two decades. Based on the calculations described in Section 4.0, we can project a timeline of water savings attributable to the WaterSense program. The savings increase each year as the program results in the installation of greater numbers of efficient products, which come to compose more and more of the product stock in households throughout the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges for Deep Vadose Zone Remediation at the Hanford Site

The “deep vadose zone” is defined as the region below the practical depth of surface remedy influence (e.g., excavation or barrier). At the Hanford Site, this region of the Central Plateau poses unique challenges for characterization and remediation. The contaminants in this region also pose a potentially significant continuing or future threat to groundwater. Currently, deep vadose zone characterization efforts and remedy selection are spread over multiple waste site Operable Units and tank farm Waste Management Areas. A particular challenge for this effort is the situation in which past leaks from single-shell tanks have become commingled with discharges from nearby liquid disposal sites. The Hanford Site is working with all affected parties, including the Washington State Department of Ecology, the Environmental Protection Agency, DOE-RL, DOE-ORP, and multiple contractor organizations to develop a unified approach to conducting work and reaching remediation decisions. This effort addresses the complex and challenging technical and regulatory issues within this environment. A true inter-Agency effort is evaluating the best strategy or combination of strategies for focusing technical investigations, including treatability studies, and for attaining remedy decisions on the Hanford Site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗