Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Electron Densities Near Io from Galileo Plasma Wave Observations

This paper presents an overview of electron densities obtained near Io from the Galileo plasma wave instrument during the first four flybys of Io. These flybys were Io, which was a downstream wake pass that occurred on December 7, 1995; I24, which was an upstream pass that occurred on October 11, 1999; I25, which was a south polar pass that occurred on November 26, 1999; and I27, which was an upstream pass that occurred on February 22, 2000. Two methods were used to measure the electron density. The first was based on the frequency of upper hybrid resonance emissions, and the second was based on the low-frequency cutoff of electromagnetic radiation at the electron plasma frequency. For three of the flybys, Io, I25, and I27, large density enhancements were observed near the closest approach to Io. The peak electron densities ranged from 2.1 to 6.8 x 10(exp 4) per cubic centimeters. These densities are consistent with previous radio occultation measurements of Io's ionosphere. No density enhancement was observed during the I24 flyby, most likely because the spacecraft trajectory passed too far upstream to penetrate Io's ionosphere. During two of the flybys, I25 and I27, abrupt step-like changes were observed at the outer boundaries of the region of enhanced electron density. Comparisons with magnetic field models and energetic particle measurements show that the abrupt density steps occur as the spacecraft penetrated the boundary of the Io flux tube, with the region of high plasma density on the inside of the flux tube. Most likely the enhanced electron density within the Io flux tube is associated with magnetic field lines that are frozen to Io by the high conductivity of Io's atmosphere, thereby enhancing the escape of plasma along the magnetic field lines that pass through Io's ionosphere.

Gurnett, D. A.↗

Satellite Infrared Radiation Measurements Prior to the Major Earthquakes

This work describes our search for a relationship between tectonic stresses and increases in mid-infrared (IR) flux as part of a possible ensemble of electromagnetic (EM) phenomena that may be related to earthquake activity. We present and &scuss observed variations in thermal transients and radiation fields prior to the earthquakes of Jan 22, 2003 Colima (M6.7) Mexico, Sept. 28 .2004 near Parkfield (M6.0) in California and Northern Sumatra (M8.5) Dec. 26,2004. Previous analysis of earthquake events has indicated the presence of an IR anomaly, where temperatures increased or did not return to its usual nighttime value. Our procedures analyze nighttime satellite data that records the general condtion of the ground after sunset. We have found from the MODIS instrument data that five days before the Colima earthquake the IR land surface nighttime temperature rose up to +4 degrees C in a 100 km radius around the epicenter. The IR transient field recorded by MODIS in the vicinity of Parkfield, also with a cloud free environment, was around +1 degree C and is significantly smaller than the IR anomaly around the Colima epicenter. Ground surface temperatures near the Parkfield epicenter four days prior to the earthquake show steady increase. However, on the night preceding the quake, a significant drop in relative humidity was indicated, process similar to those register prior to the Colima event. Recent analyses of continuous ongoing long- wavelength Earth radiation (OLR) indicate significant and anomalous variability prior to some earthquakes. The cause of these anomalies is not well understood but could be the result of a triggering by an interaction between the lithosphere-hydrosphere and atmospheric related to changes in the near surface electrical field and/or gas composition prior to the earthquake. The OLR anomaly usually covers large areas surrounding the main epicenter. We have found strong anomalies signal (two sigma) along the epicentral area signals on Dec 21, five days prior to the Northern Sumatra quake compared to the reference field for December 2001-2004 periods. Our recent results support the hypothesis of a possible relationship between a thermodynamic processes produced by increasing tectonic stress in the Earth's crust and a subsequent electro-chemical interaction between this crust and the atmosphere/ionosphere.

Ouzounov, Dimitar↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Performance of a CsBr coated Nb photocathode at room temperature

Experiments performed on Nb substrates coated with thin films of CsBr indicate a substantial enhancement of 150 to 800 times of the photoyield at 257 nm relative to the uncoated substrates. Results are presented for several power density illuminations and sample thickness. Further enhancement of photoyield was observed when the laser illumination was interrupted for a short time in samples with 5-10 nm thick CsBr coatings.

36 MATERIALS SCIENCE↗

Physics of Hot Partonic Matter at LHC-ALICE

The field of high energy nuclear physics has recently reached epoch making discoveries at the Relativistic Heavy Ton Collider at Brookhaven National Laboratory, highlighted with that of new state of nuclear matter with partonic degrees of freedom. The ALICE experiment at the Large Hadron Collider at CERN aims at comprehensive investigation and understanding of properties of the hot and dense partonic matter, as the only experiment dedicated to nucleus-nucleus collisions at the facility. Physics prospects at ALICE are reviewed including jet quenching as a probe of energy loss of quarks in the created medium, direct and thermal photons as vital probes of the thermal properties, and quarkonia as a beloved probe of color deconfinement, along with latest status of the detector systems including the high resolution electromagnetic calorimeter, PHOS, and a quick report from the first operation of LHC and ALICE in December, 2009.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

eROSITA on SRG

eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the core instrument on the Russian Spektrum-Roentgen-Gamma (SRG) mission which is scheduled for launch in late 2012. eROSITA is fully approved and funded by the German Space Agency DLR and the Max-Planck-Society.The design driving science is the detection of 50-100 thousands Clusters of Galaxies up to redshift z{approx}1.3 in order to study the large scale structure in the Universe and test cosmological models, especially Dark Energy. This will be accomplished by an all-sky survey lasting for four years plus a phase of pointed observations. eROSITA consists of seven Wolter-I telescope modules, each equipped with 54 Wolter-I shells having an outer diameter of 360 mm. This would provide and effective area at 1.5 keV of {approx}1500 cm{sup 2} and an on axis PSF HEW of 15'' which would provide an effective angular resolution of 25''-30''. In the focus of each mirror module, a fast frame-store pn-CCD will provide a field of view of 1 deg. in diameter for an active FOV of {approx}0.83 deg{sup 2}. At the time of writing the instrument development is currently in phase C/D.

79 ASTRONOMY AND ASTROPHYSICS↗

A PbWO 4 -based Neutral Particle Spectrometer in Hall C at 12 GeV JLab

The Neutral Particle Spectrometer is a standalone electromagnetic calorimeter capable of detecting high energy photons from, for instance, DVCS or π 0 decay with good energy and spatial resolution in a high rate environment. It can be used together with the Hall C high-momentum spectrometers for a suite of experiments with the underlying scientific objective of studying quark dynamics through exclusive and semi-inclusive reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMPTE IRM observations of waves associated with flux transfer events in the magnetosphere

The AMPTE IRM wave instrument has been applied to the study of flux transfer events (FTE's). This initial investigation concentrates on FTE's observed in the magnetosphere during the fall of 1984. The wave morphology consists of four significant features: at frequencies below the ion gyrofrequency, magnetic fluctuations occur with amplitudes of the order of 1 nT; at frequencies from a few hertz to a few hundred hertz, electric field fluctuations are observed which have a broadband amplitude of a few millivolts per meter, which are perpendicularly polarized at the lowest frequencies, and which are partly electrostatic and partly electromagnetic; in the frequency range from 100 Hz to 10 kHz, broadband spikelike waves occur with a time-averaged amplitude of about 0.1 mV/m; and near the electron plasma frequency, bursts of waves occur at the boundaries of FTE's. In none of the 25 events surveyed does the total broadband amplitude of all the waves exceed a few millivolts per meter, an amplitude far too small to provide the dissipation required by 'traditional' reconnection models in which the dissipation region has a thickness the order of an ion gyroradius. Thus, either all of the FTE's are observed at some distance from the diffusion region, or the observable waves play no significant role in the diffusion process, or 'traditional' reconnection models do not apply to reconnection in FTE's.

Labelle, J.↗

The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation

NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.

Koppen, Sandra V.↗

Portable modular detection system

Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.

47 OTHER INSTRUMENTATION↗

Quantum Technology and its Applications

Quantum states of matter can be exploited as high performance sensors for measuring time, gravity, rotation, and electromagnetic fields, and quantum states of light provide powerful new tools for imaging and communication. Much attention is being paid to the ultimate limits of this quantum technology. For example, it has already been shown that exotic quantum states can be used to measure or image with higher precision or higher resolution or lower radiated power than any conventional technologies, and proof-of-principle experiments demonstrating measurement precision below the standard quantum limit (shot noise) are just starting to appear. However, quantum technologies have another powerful advantage beyond pure sensing performance that may turn out to be more important in practical applications: the potential for building devices with lower size/weight/power (SWaP) and cost requirements than existing instruments. The organizers of Quantum Technology Applications Workshop (QTAW) have several goals: (1) Bring together sponsors, researchers, engineers and end users to help build a stronger quantum technology community; (2) Identify how quantum systems might improve the performance of practical devices in the near- to mid-term; and (3) Identify applications for which more long term investment is necessary to realize improved performance for realistic applications. To realize these goals, the QTAW II workshop included fifty scientists, engineers, managers and sponsors from academia, national laboratories, government and the private-sector. The agenda included twelve presentations, a panel discussion, several breaks for informal exchanges, and a written survey of participants. Topics included photon sources, optics and detectors, squeezed light, matter waves, atomic clocks and atom magnetometry. Corresponding applications included communication, imaging, optical interferometry, navigation, gravimetry, geodesy, biomagnetism, and explosives detection. Participants considered the physics and engineering of quantum and conventional technologies, and how quantum techniques could (or could not) overcome limitations of conventional systems. They identified several auxiliary technologies that needed to be further developed in order to make quantum technology more accessible. Much of the discussion also focused on specific applications of quantum technology and how to push the technology into broader communities, which would in turn identify new uses of the technology. Since our main interest is practical improvement of devices and techniques, we take a liberal definition of 'quantum technology': a system that utilizes preparation and measurement of a well-defined coherent quantum state. This nomenclature encompasses features broader than entanglement, squeezing or quantum correlations, which are often more difficult to utilize outside of a laboratory environment. Still, some applications discussed in the workshop do take advantage of these 'quantum-enhanced' features. They build on the more established quantum technologies that are amenable to manipulation at the quantum level, such as atom magnetometers and atomic clocks. Understanding and developing those technologies through traditional engineering will clarify where quantum-enhanced features can be used most effectively, in addition to providing end users with improved devices in the near-term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theoretical investigation of the generation and injection of electromagnetic waves in space plasma by means of a long-orbiting tether

Analysis of the various mechanisms of electromagnetic wave generation by the shuttle-borne orbiting tether of the T.S.S. Facility shows that significant electrodynamic power levels are available even when overestimating the loss mechanisms expected to intervene. This electrodynamic power is in part dissipated by Joule losses in the tether, in part goes to accelerate electrons through the sheath surrounding the balloon (when in a downward deployment), and in part goes into e.m. wave generation. A preliminary estimate shows that a 100 km tether in orbit would produce ULF/ELF signals that are detectable on the ground with state-of-the-art magnetometric instrumentation.

Dobrowolny, M.↗

Development of an electrostatic positioner for space material processing

This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.

Rhim, W. K.↗

Microwave landing system modeling with application to air traffic control

Compared to the current instrument landing system, the microwave landing system (MLS), which is in the advanced stage of implementation, can potentially provide significant fuel and time savings as well as more flexibility in approach and landing functions. However, the expanded coverage and increased accuracy requirements of the MLS make it more susceptible to the features of the site in which it is located. An analytical approach is presented for evaluating the multipath effects of scatterers that are commonly found in airport environments. The approach combines a multiplane model with a ray-tracing technique and a formulation for estimating the electromagnetic fields caused by the antenna array in the presence of scatterers. The model is applied to several airport scenarios. The reduced computational burden enables the scattering effects on MLS position information to be evaluated in near real time. Evaluation in near real time would permit the incorporation of the modeling scheme into air traffic control automation; it would adaptively delineate zones of reduced accuracy within the MLS coverage volume, and help establish safe approach and takeoff trajectories in the presence of uneven terrain and other scatterers.

Poulose, M. M.↗

Microwave landing system modeling with application to air traffic control automation

Compared to the current instrument landing system, the microwave landing system (MLS), which is in the advanced stage of implementation, can potentially provide significant fuel and time savings as well as more flexibility in approach and landing functions. However, the expanded coverage and increased accuracy requirements of the MLS make it more susceptible to the features of the site in which it is located. An analytical approach is presented for evaluating the multipath effects of scatterers that are commonly found in airport environments. The approach combines a multiplane model with a ray-tracing technique and a formulation for estimating the electromagnetic fields caused by the antenna array in the presence of scatterers. The model is applied to several airport scenarios. The reduced computational burden enables the scattering effects on MLS position information to be evaluated in near real time. Evaluation in near real time would permit the incorporation of the modeling scheme into air traffic control automation; it would adaptively delineate zones of reduced accuracy within the MLS coverage volume, and help establish safe approach and takeoff trajectories in the presence of uneven terrain and other scatterers.

Poulose, M. M.↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Annihilation Lines from Dark Matter with the Fermi-LAT

Dark matter is today one of the most intriguing but so far unresolved issues in physics. Many extensions of the Standard Model of particle physics predict a stable Weakly Interacting Massive Particle (WIMP) that may annihilate directly into two gamma-rays. If the WIMPs are non-relativistic, the gamma-rays from this channel will have an energy equal to the mass of the WIMP. The signature caused by this annihilation is a spectral line, smeared out only by the energy resolution of the detector. The signal would be a ''smoking gun'' for dark matter, since no other astrophysical source should be able to produce it. We present here the preliminary results from the search for a dark matter line on a limited data set from the Fermi Large Area Telescope (LAT), the main instrument onboard the Fermi Gamma-ray Space Telescope, which was successfully launched on June 11, 2008. The Fermi-LAT is a pair-conversion detector for gamma-rays with an energy range from 20 MeV to 300 GeV and has an unprecedented resolution and sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The X-ray microscopy beamline UE46-PGM2 at BESSY

The Max Planck Institute for Metal Physics in Stuttgart and the Helmholtz Center Berlin operate a soft X-ray microscopy beamline at the storage ring BESSY II. A collimated PGM serves as monochromator for a scanning X-ray microscope and a full field X-ray microscope at the helical undulator UE46. The selection between both instruments is accomplished via two switchable focusing mirrors. The scanning microscope (SM) is based on the ALS STXM microscope and fabricated by the ACCEL company. The full field microscope (FFM) is currently in operation at the U41-SGM beamline and will be relocated to its final location this year.

43 PARTICLE ACCELERATORS↗