Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Simulation Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Simulation of heavy ion reactions on gas target with GEANT 4

A research program based on the direct measurement of (alpha,p) and (alpha,n) reactions induced by radioactive ion beams in inverse kinematics of astrophysical interest is to be initiated at the Pelletron laboratory in Sao Paulo. These alpha-induced reactions are present in many astrophysical environments such as those leading to X-ray bursts, the rapid proton-capture (rp-) process, hot pp-cycle in massive stars. Radioactive ion beams and a {sup 4}He gas target are required to investigate such kind of reactions. The gaseous helium target will be cooled down to the nitrogen liquid temperature (70 K) to increase its density. Simulations of such reactions by Monte Carlo technique, using GEANT4, a toolkit written in object oriented language (C++), is being used to obtain informations on the geometrical as well as dynamic parameters for this gas target before we construct it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A study of astrometric distortions due to “tree rings” in CCD sensors using LSST Photon Simulator

Imperfections in the production process of thick CCDs lead to circularly symmetric dopant concentration variations, which in turn produce electric fields transverse to the surface of the fully depleted CCD that displace the photogenerated charges. We use PhoSim, a Monte Carlo photon simulator, to explore and examine the likely impacts these dopant concentration variations will have on astrometric measurements in LSST. The scale and behavior of both the astrometric shifts imparted to point sources and the intensity variations in flat field images that result from these doping imperfections are similar to those previously observed in Dark Energy Camera CCDs, giving initial confirmation of PhoSim's model for these effects. In addition, the organized shape distortions were observed as a result of the symmetric nature of these dopant variations, causing nominally round sources to be imparted with a measurable ellipticity either aligned with or transverse to the radial direction of this dopant variation pattern.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic properties of a staggered S = 1 chain with an alternating single-ion anisotropy direction

Materials composed of spin-1 antiferromagnetic (AFM) chains are known to adopt complex ground states that are sensitive to the single-ion-anisotropy (SIA) energy ( D ), and intrachain ( J 0 ) and interchain ( J 1 , 2 ′ ) exchange energy scales. While theoretical and experimental studies have extended this model to include various other energy scales, the effect of the lack of a common SIA axis is not well explored. Here we investigate the magnetic properties of Ni ( pyrimidine ) ( H 2 O ) 2 ( NO 3 ) 2 , a chain compound where the tilting of Ni octahedra leads to a twofold alternation of the easy-axis directions along the chain. Muon-spin relaxation measurements indicate a transition to long-range order at T N = 2.3 K and the magnetic structure is initially determined to be antiferromagnetic and collinear using elastic neutron diffraction experiments. Inelastic neutron scattering measurements were used to find J 0 = 5.107 ( 7 ) K , D = 2.79 ( 1 ) K , J 1 ′ = 0.00 ( 5 ) K , J 2 ′ = 0.18 ( 3 ) K , and a rhombic anisotropy energy E = 0.19 ( 9 ) K . Mean-field modeling reveals that the ground state structure hosts spin canting of ϕ ≈ 6 . 5 ∘ , which is not detectable above the noise floor of the elastic neutron diffraction data. Monte Carlo simulation of the powder-averaged magnetization, M ( H ) , is then used to confirm these Hamiltonian parameters, while single-crystal M ( H ) simulations provide insight into features observed in the data. Published by the American Physical Society 2025

Vaidya, S. (ORCID:000000033975497X)↗

Impact of direct exchange coupling via the insulator on the magnetic tunnel junction based molecular spintronics devices with competing molecule induced inter-electrode coupling

The magnetic tunnel junction (MTJ) based molecular spintronics device (MTJMSD) approach is suitable for mass production. This approach provides solutions to fabrication difficulties related to reliably connecting molecular device elements to the ferromagnets (FMs). To producing MTJMSD, the molecular channels are bridged across the insulator of an MTJ testbed with exposed side edges. In an MTJMSD, two FMs are simultaneously connected by an insulator film and the molecular channels along the exposed sides. In our prior experimental studies, we observed that molecules could produce strong coupling between ferromagnets in the presence of the competing coupling via an insulator. In this paper, our Monte Carlo Simulation (MCS) was used to study the impact of coupling variation via insulator (a.k.a. Ji) on the magnetic properties of an MTJMSD. We studied the effect of Ji while varying the molecule induced antiferromagnetic exchange coupling. The ferromagnetic or antiferromagnetic nature and magnitude of Ji determined the resultant effect. Antiferromagnetic Ji enhanced the pre-existing antiferromagnetic molecular coupling effect. Ferromagnetic Ji competed with the opposite nature of antiferromagnetic molecular coupling. Our MCS may help to understand the impact of insulator thickness and defects on the molecular spintronics device performance and design process.

36 MATERIALS SCIENCE↗

Formation and coarsening of epitaxially-supported metal nanoclusters

This mini-review describes developments over the last ~30 years in characterizing the nucleation & growth of epitaxially-supported metal nanoclusters (NCs) or islands during vapor deposition, as well as their post-deposition coarsening. A beyond-mean-field treatment for homogeneous nucleation & growth corrects the deficiencies of traditional treatments in describing, e.g., the island size distribution, but also necessitates consideration of the spatial distribution of islands and their capture zones. We discuss advances in modeling capabilities, including those based upon on an ab-initio level treatment of periphery diffusion kinetics, for description of the non-equilibrium growth shapes of these NCs, focusing on 2D NCs. For post-deposition coarsening of arrays of NCs, there is generally a competition between Ostwald Ripening (OR) and Smoluchowski Ripening (SR). SR is also known as Particle Migration & Coalescence. For 2D NCs in homoepitaxial systems, conventional OR is observed on pristine fcc(111) surfaces, dramatically enhanced OR in the presence of even trace amounts of chalcogens for Cu(111) and Ag(111), and anomalous OR on anisotropic fcc(110) surfaces. The unexpected discovery of SR for fcc(100) homoepitaxial systems prompted extensive analysis of the underlying diffusivities of 2D NCs as a function of size, as well as of NC coalescence dynamics. A comprehensive understanding of these processes is now available. Self-assembly of 3D NCs during deposition, issues related to heterogeneous nucleation, directed assembly, NC growth structure selection, and coarsening are addressed. Finally, for SR of 3D epitaxial NCs, recent insights into the size-dependence of diffusivity are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dust and gas absorption in the high mass X-ray binary IGR J16318-4848

With an absorption column density on the order of 10 24 cm -2 , IGR J16318-4848 is one of the most extreme cases of a highly obscured high mass X-ray binary. In addition to the overall continuum absorption, the source spectrum exhibits a strong iron and nickel fluorescence line complex at 6.4 keV. Previous empirical modeling of these features and comparison with radiative transfer simulations raised questions about the structure and covering fraction of the absorber and the profile of the fluorescence lines. We aim at a self-consistent description of the continuum absorption, the absorption edges, and the fluorescence lines to constrain the properties of the absorbing material, such as ionization structure and geometry. We further investigate the effects of dust absorption on the observed spectra and the possibility of fluorescence emission from dust grains. We used XMM-Newton and NuSTAR spectra to first empirically constrain the incident continuum and fluorescence lines. Next we used XSTAR to construct a customized photoionization model where we vary the ionization parameter, column density, and covering fraction. In the third step we modeled the absorption and fluorescence in a dusty olivine absorber and employed both a simple analytical model for the fluorescence line emission and a Monte Carlo simulation of radiative transfer that generates line fluxes, which are very close to the observational data. Our empirical spectral modeling is in agreement with previous works. Our second model, the single gas absorber does not describe the observational data. In particular, irrespective of the ionization state or column density of the absorber, a much higher covering fraction than previously estimated is needed to produce the strong fluorescence lines and the large continuum absorption. A dusty, spherical absorber (modeled as consisting of olivine dust, although the nature of dust cannot be constrained) is able to produce the observed continuum absorption and edges. A dense, dusty absorber in the direct vicinity of the source consisting of dust offers a consistent description of both the strong continuum absorption and the strong emission features in the X-ray spectrum of IGR J16318-4848. In particular, for low optical depth of individual grains, which is the case for typical volume densities and grain size distribution models, the dust will contribute significantly to the fluorescence emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Pairing Correlations across the Superfluid Phase Transition in the Unitary Fermi Gas

In the two-component Fermi gas with a contact interaction, a pseudogap regime can exist at temperatures between the superfluid critical temperature $T_c$ and a temperature $T^\ast > T_c$. This regime is characterized by pairing correlations without superfluidity. However, in the unitary limit of infinite scattering length, the existence of this regime is still debated. To help address this, we have applied finite-temperature auxiliary-field quantum Monte Carlo (AFMC) methods to study the thermodynamics of the superfluid phase transition and signatures of the pseudogap in the spin-balanced homogeneous unitary Fermi gas. We present results at finite filling factor $\textit{ν}$ ≃ 0.06 for the condensate fraction, an energy-staggering pairing gap, the spin susceptibility, and the heat capacity, and compare them to experimental data when available. In contrast to previous AFMC simulations, our model space consists of the complete first Brillouin zone of the lattice, and our calculations are performed in the canonical ensemble of fixed particle number. The canonical ensemble AFMC framework enables the calculation of a model-independent gap, providing direct information on pairing correlations without the need for numerical analytic continuation. We use finite-size scaling to estimate $T_c$ at the corresponding filling factor. In this work, we find that the energy-staggering pairing gap vanishes above $T_c$, showing no pseudogap effects, and that the spin susceptibility shows a substantially reduced signature of a spin gap compared to previously reported AFMC simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-SPS-11: The Dosimetric Comparison of Truebeam 2.0 and Cyberknife M6 Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of Truebeam 2.0 and Cyberknife M6 treatment plans were made. Methods: For Truebeam 2.0 machine, treatment planning were done using 2 full arc VMAT technique with 6 FFF beam on the CT scan of Randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using Eclipse treatment planning system with Acuros XB algorithm. The treatment planning of the same target were also done for Cyberknife M6 machine with Multiplan treatment planning system using Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For Truebeam plans, the gamma analysis passing rates were 99.1% and 95.5% for target and peripheral region of target respectively. Conclusion: Although, target dose distribution calculated accurately by Acuros XB and Monte Carlo algorithms, Monte carlo calculation algorithm predicts dose distribution around the peripheral region of target more accurately than Acuros algorithm.

60 APPLIED LIFE SCIENCES↗

Waveform-dependent air fluorescence from neutral and ionic nitrogen molecules

Laser-induced air fluorescence in the ultraviolet regime is primarily attributed to transitions between the C and B states in excited neutral N 2 molecules and between the B and X states in N$^+_2$ ions. However, the mechanism underlying the former remains contentious, as direct population to the C state by light fields is forbidden by electron spin constraints. In this work, we investigate the mechanism of air fluorescence from excited neutral N 2 molecules by carrier-envelope phase–stabilized sub–4 femtosecond pulses. Our results show that fluorescence from N$^+_2$ ions reaches a maximum with cosine-like pulses, while fluorescence from excited neutral N 2 molecules peaks with sine-like pulses. In addition, by scanning the chirp of the driving pulse, we find that ionic fluorescence is maximized with chirp-free pulses, whereas neutral fluorescence favors negatively chirped pulses. These observations, supported by classical trajectory Monte Carlo simulations, support the mechanism of intersystem crossing from excited spin-singlet states, which are populated via recollision-induced strong-field excitation.

Science & Technology - Other Topics↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Evaluated Iridium, Yttrium, and Thulium Cross Sections and Integral Validation Against Critical Assembly and Bethe Sphere Measurements

We describe new dosimetry (radiochemical) ENDF evaluations for yttrium, iridium, and thulium. These LANL2006 evaluations were based upon measured data and on nuclear model cross section calculations. In the case of iridium and yttrium, new measurements using the GEANIE gamma-ray detector at LANSCE were used to infer (n,xn) cross sections, the measurements being augmented by nuclear model calculations using the GNASH code. The thulium isotope evaluations were based on GNASH calculations and older measurements. The evaluated cross section data are tested through comparisons of simulations with measurements of reaction rates in critical assemblies and in Bethe sphere (sometimes called Wyman sphere) integral experiments. Two types of Bethe sphere experiments were studied - a LiD experiment that had a significant component of 14 MeV neutrons, and a LiD-U experiment that additionally had varying amounts of fission neutrons depending upon the location. These simulations were performed with the MCNP code using continuous energy Monte Carlo, and because the neutron fluences can be modeled fairly accurately by MCNP at different locations in these assemblies, the comparisons provide a valuable validation test of the accuracy of the evaluated cross sections and their energy dependencies. The MCNP integral reaction rate validation testing for the three detectors yttrium, iridium, and thulium, in the LANL2006 database is summarized as follows: (1) (n,2n)near 14 MeV: In 14 MeV-dominated locations (the LiD Bethe spheres and the outer regions of the LiD-U Bethe spheres), the (n,2n) products are modeled very well for all three detectors, suggesting that the evaluated {sup 89}Y(n,2n), {sup 191}Ir(n,2n), and {sup 169}Tm(n,2n) cross sections are accurate to better than about 5% near 14 MeV; (2) (n,2n)near threshold: In locations that have a significant number of fission spectrum neutrons or downscattered neutrons from 14 MeV inelastic scattering (the central regions of the LiD-U spheres and the fast critical assemblies), the (n,2n) products are overpredicted by 5-30 % for the three detectors, suggesting either the threshold region (n,2n) cross sections are too high, or that the MCNP-simulated neutron flux is too large for neutron energies above about 8 MeV; (3) Capture: The capture products for yttrium are modeled accurately for the LiD Bethe spheres, but are underpredicted by about 20% for the LiD-U Bethe spheres and the critical assemblies; for iridium-191 they are predicted accurately in the critical assemblies; and for thulium they are generally overpredicted by 10-30 %; (4) Inelastic scattering in iridium: The evaluated {sup 193}Ir(n,n{sup '}){sup 193m}Ir cross section performs well over a very wide range of neutron spectra (where the 193m/190 spectrum hardness index varies by over three orders of magnitude), the differences between simulation and experiment typically being better than 10-15%; (5) Iridium 193m/190 spectrum hardness index: Our simulations reproduce the measured 193m/190 data typically to better than 10-20% over three orders of magnitude in the 193m/190 ratio. The aforementioned indications from data testing involving assemblies containing actinides - that the (n,2n) products are overpredicted by 5-30% - could be used to motivate a decrease in the evaluated (n,2n) cross sections in the approximately 8-12 MeV range. However, at this stage we have not modified these cross sections since: (a) They are consistent with the cross section laboratory measurements; and (b) It is possible that the cross sections are correct and instead the simulated integral assembly neutron spectrum is too high for neutron energies above 8 MeV. The latter possibility is particularly intriguing given all three detector materials showed a bias in the same direction, and that the evaluated actinide prompt fission spectra and inelastic scattering data are probably uncertain to at least 20% above 8 MeV. We also discuss refinements needed in the transport methods to faithfully represent the evaluated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Segregation and Phase Stability in Candidate Alloys for the Advanced Burner Reactor

Major accomplishments of this project were the following: 1) Radiation induced depletion of Cr occurs in alloy D9, in agreement with that observed in austenitic alloys. 2) In F-M alloys, Cr enriches at PAG grain boundaries at low dose (<7 dpa) and at intermediate temperature (400°C) and the magnitude of the enrichment decreases with temperature. 3) Cr enrichment decreases with dose, remaining enriched in alloy T91 up to 10 dpa, but changing to depletion above 3 dpa in HT9 and HCM12A. 4) Cr has a higher diffusivity than Fe by a vacancy mechanism and the corresponding atomic flux of Cr is larger than Fe in the opposite direction to the vacancy flux. 5) Cr concentration at grain boundaries decreases as a result of vacancy transport during electron or proton irradiation, consistent with Inverse Kirkendall models. 6) Inclusion of other point defect sinks into the KLMC simulation of vacancy-mediated diffusion only influences the results in the low temperature, recombination dominated regime, but does not change the conclusion that Cr depletes as a result of vacancy transport to the sink. 7) Cr segregation behavior is independent of Frenkel pair versus cascade production, as simulated for electron versus proton irradiation conditions, for the temperatures investigated. 8) The amount of Cr depletion at a simulated planar boundary with vacancy-mediated diffusion reaches an apparent saturation value by about 1 dpa, with the precise saturation concentration dependent on the ratio of Cr to Fe diffusivity. 9) Cr diffuses faster than Fe by an interstitial transport mechanism, and the corresponding atomic flux of Cr is much larger than Fe in the same direction as the interstitial flux. 10) Observed experimental and computational results show that the radiation induced segregation behavior of Cr is consistent with an Inverse Kirkendall mechanism.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation, Analysis, and Simulation of Active Alignment Strategies for the James Webb Space Telescope

This paper presents three characteristics in the simulated active alignment strategy of the James Webb Space Telescope. The first includes the analysis and comparison of a baseline active alignment strategy with a damped least squares strategy. This baseline utilizes prior knowledge by means of direct human operator interaction to engage sets of telescope compensators to target specific aberration signatures. The baseline is compared to a damped least-squares strategy that utilizes simultaneous engagement of all telescope compensators without explicit human operator inter<actiori to achieve a least-squares telescope compensation. Second, we discuss how the active alignment of the JWST is encapsulated in a linear optical model developed at the Space Telescope Science Institute. This linear optical model provides a framework for an efficient and robust description of the optical control properties of the JWST and clearly articulates the necessity for having a multi-instrument multi-field wavefront sensing strategy to overcome control system non independence and the effects of non-common path errors in the main wavefront sensing camera. Finally. we present analytical results that explicitly map the telescope wavefront responses to the telescope control modes, and we present Monte-Carlo optical performance simulation results that demonstrate the efficacy of the damped least-squares active alignment and the prior-knowledge active alignment schemes.

Upton, Robert S.↗

Alloy Design Workbench-Surface Modeling Package Developed

NASA Glenn Research Center's Computational Materials Group has integrated a graphical user interface with in-house-developed surface modeling capabilities, with the goal of using computationally efficient atomistic simulations to aid the development of advanced aerospace materials, through the modeling of alloy surfaces, surface alloys, and segregation. The software is also ideal for modeling nanomaterials, since surface and interfacial effects can dominate material behavior and properties at this level. Through the combination of an accurate atomistic surface modeling methodology and an efficient computational engine, it is now possible to directly model these types of surface phenomenon and metallic nanostructures without a supercomputer. Fulfilling a High Operating Temperature Propulsion Components (HOTPC) project level-I milestone, a graphical user interface was created for a suite of quantum approximate atomistic materials modeling Fortran programs developed at Glenn. The resulting "Alloy Design Workbench-Surface Modeling Package" (ADW-SMP) is the combination of proven quantum approximate Bozzolo-Ferrante-Smith (BFS) algorithms (refs. 1 and 2) with a productivity-enhancing graphical front end. Written in the portable, platform independent Java programming language, the graphical user interface calls on extensively tested Fortran programs running in the background for the detailed computational tasks. Designed to run on desktop computers, the package has been deployed on PC, Mac, and SGI computer systems. The graphical user interface integrates two modes of computational materials exploration. One mode uses Monte Carlo simulations to determine lowest energy equilibrium configurations. The second approach is an interactive "what if" comparison of atomic configuration energies, designed to provide real-time insight into the underlying drivers of alloying processes.

Abel, Phillip B.↗