Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Cartography of irregularly shaped satellites

Irregularly shaped satellites, such as Phobos and Amalthea, do not lend themselves to mapping by conventional methods because mathematical projections of their surfaces fail to convey an accurate visual impression of the landforms, and because large and irregular scale changes make their features difficult to measure on maps. A digital mapping technique has therefore been developed by which maps are compiled from digital topographic and spacecraft image files. The digital file is geometrically transformed as desired for human viewing, either on video screens or on hard copy. Digital files of this kind consist of digital images superimposed on another digital file representing the three-dimensional form of a body.

Batson, R. M.↗

Image gathering and digital restoration for fidelity and visual quality

The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

Huck, Friedrich O.↗

Optical Synchrotron Radiation Beam Imaging with a Digital Mask

We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

43 PARTICLE ACCELERATORS↗

Overview of the Digitization Workflow Post Image Acquisition of Apollo Lunar and Antarctic Meteorite Samples Using Agisoft Photoscan for the NASA 3D Astromaterials Virtual Samples Collection

The 3D Virtual Astromaterials Samples (3DVAS) collection is a multi-year funded project to create a digital database of sixty Apollo Lunar and Antarctic Meteorite samples following non-destructive documentation conservation protocols. After initial image processing, the photos are evaluated and processed using unique structure-from-motion photogrammetric techniques in a high performance modelling software designed to create a 3D model from 2D images: Agisoft Photoscan Pro. Agisoft Photoscan Pro uses image processing algorithms and techniques originating in computer vision to resolve 3D models for accurate and detailed visualization of a subject. The software provides a stepwise process that is tailored per model based on spatial and specular reflectance properties, for example. The process includes: photo alignment, creation of a dense point cloud, mesh, and finally texture. Photo alignment is dependent on model properties. The 3DVAS process requires a special rotation platform with calibrated photogrammetric targets, specific distance rotation protocols, and a contrasting background for alignment and scale accuracy. As a result of the photographic process, alignment will complete with two mirrored hemispheres that, in a sense, represent the 2D images overlapping to create a 3D model. Each dense point cloud is analyzed with provided statistical measures in a gradual selection process to eliminate outliers. The point cloud is reduced to include only data valuable to the final model. When a precise dense point cloud is achieved, a mesh and texture are applied. Each model is scaled with scale bar accuracies within 100 microns. Each sample has its own intimate process for modelling; there is no standard for the parameters required in the final creation of a high resolution model. By processing multiple samples, a skill is gained in practice to allow a close definition of the original sample and will result in the most detailed version of the sample shell. This process completes one-fifth of the 3DVAS protocol for providing accurate digital documentation. Each model shell is merged with X-ray Computed Tomography data to create a full volumetric sample. All 3DVAS data will be served on NASA's Astromaterials Acquisition and Curation website with an early subset of data available in 2019 and the 3D Virtual Astromaterials Samples Collection launch in 2020.

Thomas, Andi B.↗

Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications.

60 APPLIED LIFE SCIENCES↗

THE SLOAN DIGITAL SKY SURVEY STRIPE 82 IMAGING DATA: DEPTH-OPTIMIZED CO-ADDS OVER 300 deg{sup 2} IN FIVE FILTERS

We present and release co-added images of the Sloan Digital Sky Survey (SDSS) Stripe 82. Stripe 82 covers an area of ∼300 deg{sup 2} on the celestial equator, and has been repeatedly scanned 70-90 times in the ugriz bands by the SDSS imaging survey. By making use of all available data in the SDSS archive, our co-added images are optimized for depth. Input single-epoch frames were properly processed and weighted based on seeing, sky transparency, and background noise before co-addition. The resultant products are co-added science images and their associated weight images that record relative weights at individual pixels. The depths of the co-adds, measured as the 5σ detection limits of the aperture (3.''2 diameter) magnitudes for point sources, are roughly 23.9, 25.1, 24.6, 24.1, and 22.8 AB magnitudes in the five bands, respectively. They are 1.9-2.2 mag deeper than the best SDSS single-epoch data. The co-added images have good image quality, with an average point-spread function FWHM of ∼1'' in the r, i, and z bands. We also release object catalogs that were made with SExtractor. These co-added products have many potential uses for studies of galaxies, quasars, and Galactic structure. We further present and release near-IR J-band images that cover ∼90 deg{sup 2} of Stripe 82. These images were obtained using the NEWFIRM camera on the NOAO 4 m Mayall telescope, and have a depth of about 20.0-20.5 Vega magnitudes (also 5σ detection limits for point sources)

79 ASTRONOMY AND ASTROPHYSICS↗

Ice Sheet Change Detection by Satellite Image Differencing

Differencing of digital satellite image pairs highlights subtle changes in near-identical scenes of Earth surfaces. Using the mathematical relationships relevant to photoclinometry, we examine the effectiveness of this method for the study of localized ice sheet surface topography changes using numerical experiments. We then test these results by differencing images of several regions in West Antarctica, including some where changes have previously been identified in altimeter profiles. The technique works well with coregistered images having low noise, high radiometric sensitivity, and near-identical solar illumination geometry. Clouds and frosts detract from resolving surface features. The ETM(plus) sensor on Landsat-7, ALI sensor on EO-1, and MODIS sensor on the Aqua and Terra satellite platforms all have potential for detecting localized topographic changes such as shifting dunes, surface inflation and deflation features associated with sub-glacial lake fill-drain events, or grounding line changes. Availability and frequency of MODIS images favor this sensor for wide application, and using it, we demonstrate both qualitative identification of changes in topography and quantitative mapping of slope and elevation changes.

Bindschadler, Robert A.↗

Binocular high dynamic range imaging system based on digital micromirror device

In the applications of scientific imaging and space exploration, the dynamic range of imaging systems is usually required to reach more than 120 dB. In order to observe a highly dynamic scene in real time, we designed an imaging system based on a digital micromirror device (DMD) that is used as a spatial light modulator. First, we designed a binocular highly dynamic light-adjusting system based on a DMD according to the DMD’s optical structure. Second, in order to realize the registration between the micromirrors of a DMD and pixels of the two cameras, a pixel-matching algorithm was developed. Finally, we introduce a novel light-adjusting algorithm that can recover the highly dynamic data of the dynamic scene. Experiments showed that the deviation between the DMD and the two cameras is reduced to 0.48 pixels after correction, and that bright and dark targets in a high-dynamic-range scene can both be displayed simultaneously in one image with high quality after light adjustment. The dynamic range of the system is theoretically 209 dB, which meets the requirements of high-dynamic-range observation.

42 ENGINEERING↗

Evaluation of U-net-based Image Segmentation Model to Digital Mammography

Detecting suspicious lesions in medical imaging is the important first step in computer-aided detection (CAD) systems. However, detecting abnormalities in breast tissue is difficult due to the lesion's varying size, shape, margin, and contrast with the background tissue. We focused on mass segmentation, a method that provides notable morphological features by outlining contours of masses. Accurate segmentation is crucial for correct diagnosis. Recent advancements in deep learning have improved object detection and segmentation, and these techniques are also being applied to medical imaging studies. We focused on U-net, which is a recently developed mass segmentation algorithm based on a fully convolutional network. The U-net architecture consists of (1) a contracting path to increase the resolution of the output and (2) a symmetric expanding path to better locate the region of interest. The performance of a U-net model was tested with 63 digital mammograms from INbreast, a publicly available database. We trained the model with images resized to 40x40 pixels and conducted 10-fold cross-validation to prevent overfitting. The model's performance with respect to breast density and the lesion's BI-RADS rating was also investigated. Dice coefficients (DC) were used as a performance measure to compare the predicted segmentation of the model with the ground truth. Logistic regression and an analysis of variance were performed to determine the significance of the DCs with regards to breast density and lesion behavior and to calculate the 95% confidence interval. The average DC was 0.80. The difference between DCs for BI-RADS 2 and 4c and for BI-RADS 2 and 5 were significant, suggesting that the model has more difficulty in segmenting benign lesions.

Cho, Priscilla↗

Edge detection - Image-plane versus digital processing

To optimize edge detection with the familiar Laplacian-of-Gaussian operator, it has become common to implement this operator with a large digital convolution mask followed by some interpolation of the processed data to determine the zero crossings that locate edges. It is generally recognized that this large mask causes substantial blurring of fine detail. It is shown that the spatial detail can be improved by a factor of about four with either the Wiener-Laplacian-of-Gaussian filter or an image-plane processor. The Wiener-Laplacian-of-Gaussian filter minimizes the image-gathering degradations if the scene statistics are at least approximately known and also serves as an interpolator to determine the desired zero crossings directly. The image-plane processor forms the Laplacian-of-Gaussian response by properly combining the optical design of the image-gathering system with a minimal three-by-three lateral-inhibitory processing mask. This approach, which is suggested by Marr's model of early processing in human vision, also reduces data processing by about two orders of magnitude and data transmission by up to an order of magnitude.

Huck, Friedrich O.↗

Comparative Study Of Image Enhancement Algorithms For Digital And Film Mammography

Here we discuss the application of edge enhancement algorithms on images obtained with a Mammography System which has a Selenium Detector and on the other hand, on images obtained from digitized film mammography. Comparative analysis of such images includes the study of technical aspects of image acquisition, storage, compression and display. A protocol for a local database has been created as a result of this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Interpolation With Dedicated Digital Hardware

Algorithm for interpolating two-dimensional image data to change picture-element spacing implemented in dedicated digital hardware for high-speed execution. System interpolates 100 times as fast as generalpurpose computer. Image resampling occurs first along one image axis and then along other, using two interpolation devices implemented in series.

Hartenstein, R.↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Stereocorrelation of Landsat TM images

A digital elevation model (DEM) developed from Landsat TM images of a rugged terrain area in north Georgia by automated stereocorrelation techniques yielded an rms error (z), RMSE(z), value of + or - 42 m. Based on the B/H ratio of 0.18 for the Landsat data, this Z-error corresponds to a planimetric correlation accuracy of about + or - 0.3 pixels, confirming that precise correlation can be achieved with operational satellite data. Contours at a 100-m interval interpolated from the DEM show a deviation of + or - 33 m from reference contours obtained from existing 1:24,000-scale maps. The 28.5-m pixel resolution and the weak B/H ratio impose limitations on the accuracy that can be achieved with Landsat TM data. However, it is anticipated that RMSE(z) values of + or - 10 m or less can be achieved with SPOT-1 panchromatic stereo images of 10-m resolution recorded at B/H ratios of 0.5 to 1.0. DEMs generated by stereocorrelation techniques can be used to create orthoimages, perspective views, and topographic map products.

Ehlers, Manfred↗

Incorporating the APS Catalog of the POSS I and Image Archive in ADS

The primary purpose of this contract was to develop the software to both create and access an on-line database of images from digital scans of the Palomar Sky Survey. This required modifying our DBMS (called Star Base) to create an image database from the actual raw pixel data from the scans. The digitized images are processed into a set of coordinate-reference index and pixel files that are stored in run-length files, thus achieving an efficient lossless compression. For efficiency and ease of referencing, each digitized POSS I plate is then divided into 900 subplates. Our custom DBMS maps each query into the corresponding POSS plate(s) and subplate(s). All images from the appropriate subplates are retrieved from disk with byte-offsets taken from the index files. These are assembled on-the-fly into a GIF image file for browser display, and a FITS format image file for retrieval. The FITS images have a pixel size of 0.33 arcseconds. The FITS header contains astrometric and photometric information. This method keeps the disk requirements manageable while allowing for future improvements. When complete, the APS Image Database will contain over 130 Gb of data. A set of web pages query forms are available on-line, as well as an on-line tutorial and documentation. The database is distributed to the Internet by a high-speed SGI server and a high-bandwidth disk system. URL is http://aps.umn.edu/IDB/. The image database software is written in perl and C and has been compiled on SGI computers with MIX5.3. A copy of the written documentation is included and the software is on the accompanying exabyte tape.

Humphreys, Roberta M.↗

HIGH-RESOLUTION VERY LARGE ARRAY IMAGING OF SLOAN DIGITAL SKY SURVEY STRIPE 82 AT 1.4 GHz

We present a high-resolution radio survey of the Sloan Digital Sky Survey (SDSS) Southern Equatorial Stripe, a.k.a. Stripe 82. This 1.4 GHz survey was conducted with the Very Large Array primarily in the A-configuration, with supplemental B-configuration data to increase sensitivity to extended structure. The survey has an angular resolution of 1.''8 and achieves a median rms noise of 52 {mu}Jy beam{sup -1} over 92 deg{sup 2}. This is the deepest 1.4 GHz survey to achieve this large of an area, filling a gap in the phase space between small, deep and large, shallow surveys. It also serves as a pilot project for a larger high-resolution survey with the Expanded Very Large Array. We discuss the technical design of the survey and details of the observations, and we outline our method for data reduction. We present a catalog of 17,969 isolated radio components, for an overall source density of {approx}195 sources deg{sup -2}. The astrometric accuracy of the data is excellent, with an internal check utilizing multiply observed sources yielding an rms scatter of 0.''19 in both right ascension and declination. A comparison to the SDSS DR7 Quasar Catalog further confirms that the astrometry is well tied to the optical reference frame, with mean offsets of 0.''02 {+-} 0.''01 in right ascension, and 0.''01 {+-} 0.''02 in declination. A check of our photometry reveals a small, negative CLEAN-like bias on the level of 35 {mu}Jy. We report on the catalog completeness, finding that 97% of FIRST-detected quasars are recovered in the new Stripe 82 radio catalog, while faint, extended sources are more likely to be resolved out by the resolution bias. We conclude with a discussion of the optical counterparts to the catalog sources, including 76 newly detected radio quasars. The full catalog as well as a search page and cutout server are available online at http://third.ucllnl.org/cgi-bin/stripe82cutout.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-303-01: FEATURED PRESENTATION: A Dual-Detector Phase-Matched Digital Tomosynthesis (DTS) Imaging Scheme Using Aggregated KV and MV Projections for Intra-Treatment Lung Tumor Tracking

Purpose: To develop a dual-detector phase-matched DTS technique for continuous and fast intra-treatment lung tumor localization. Methods: Tumor localization accuracy of limited-angle DTS imaging is affected by low inter-slice resolution. The dual-detector DTS technique aims to overcome this limitation through combining orthogonally acquired beam’s eye view MV projections and kV projections for intra-treatment DTS reconstruction and localization. To aggregate the kV and MV projections for reconstruction, the MV projections were linearly converted to synthesize corresponding kV projections. To further address the lung motion induced localization errors, this technique uses respiratory phase-matching to match the motion information between on-board DTS and reference DTS to offset the adverse effects of motion blurriness in tumor localization.A study was performed using the CIRS008A lung phantom to simulate different on-board target variation scenarios for localization. The intra-treatment kV and MV acquisition was achieved through the Varian TrueBeam Developer Mode. Four methods were compared for their localization accuracy: 1. the proposed dual-detector phase-matched DTS technique; 2. the single-detector phase-matched DTS technique; 3. the dual-detector 3D-DTS technique without phase-matching; and 4. the single-detector 3D-DTS technique without phase-matching. Results: For scan angles of 2.5°, 5°, 10°, 20° and 30°, the dual-detector phase-matched DTS technique localized the tumor with average(±standard deviations) errors of 0.4±0.3 mm, 0.5±0.3 mm, 0.6±0.2 mm, 0.9±0.4 mm and 1.0±0.3 mm, respectively. The corresponding values of single-detector phase-matched DTS technique were 4.0±2.5 mm, 2.7±1.1 mm, 1.7±1.2 mm, 2.2±0.9 mm and 1.5±0.8 mm, respectively. The values of dual-detector 3D-DTS technique were 6.2±1.7 mm, 6.3±1.2 mm, 5.3±1.3 mm, 2.0±2.2 mm and 1.5±0.5 mm, respectively. And the values of single-detector 3D-DTS technique were 9.7±8.9 mm, 9.8±8.8 mm, 10.0±9.7 mm, 3.9±2.7 mm and 2.2±1.3 mm, respectively. Conclusion: The dual-detector phase-matched DTS technique substantially improves the tumor localization accuracy, which can be applied to real-time intra-treatment lung tumor localization. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗