Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons

The focus of this document is to record the learning and process development achieved by the completion of the Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons LDRD. The goal of this effort was to study different silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2-layer superlattice. Enabling the preparation of the surface of silicon detectors (front side illuminated or bonded backside illuminated) increases the responsivity of the diode to shallowly absorbed photons. This increased sensitivity in turn allows for greater fidelity in imaging events that emit low soft X-rays or low energy electrons. Prior work has focused on passivating the surface of a silicon detectors with thin layers (tens of nm thick) of materials to reduce surface recombination sites. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2- layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

42 ENGINEERING↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

Neutron light output function and resolution investigation of the deuterated organic liquid scintillator EJ-315

Here, we investigate the light response to fast neutrons and estimate the pulse height resolution of a deuterated liquid organic scintillator, EJ-315, considering the detector's non-linear light response to gamma-rays. Initially, collision data and a neutron beam trigger are recorded in coincidence mode, and incident neutron energy is calculated with a time-of-flight technique. Fast neutrons are further discriminated from gamma-ray background based on the scintillation material decay patterns using a pulse shape discrimination algorithm. We also derived a light response matrix composed of multiple neutron energy and their corresponding light outputs. The pulse height resolution property of the EJ-315 is characterized utilizing the derivatives of the pulse height distributions with corrections of the mea-surements setup uncertainties. In addition, the EJ-315's pulse height resolution is also characterized by comparing the smoothed derivatives of quasi-monoenergetic neutron pulse height distributions, given by the Peierls-formula-based analytic model, to match the measurement data. Results show rather consistent 10e13% pulse resolution for mono-energetic neutrons with kinetic energy above 2 MeV. The resolution decreases slightly with an increase in neutron energy indicating the improved resolution performance of EJ-315 in the higher energy events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, I, Q and U, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of ~0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization (I→P) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the {\scshape Polarbear} experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the I→P leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz (ℓ ~ 39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Si IR detectors using molecular beam epitaxy

SiGe/Si heterojunction internal photoemission (HIP) long wavelength infrared (LWIR) detectors have been fabricated by MBE. The SiGe/Si HIP detector offers a tailorable spectral response in the long wavelength infrared regime by varying the SiGe/Si heterojunction barrier. Degenerately doped p(+) SiGe layers were grown using elemental boron, as the dopant source allows a low growth temperature. Good crystalline quality was achieved for boron-doped SiGe due to the reduced growth temperature. The dark current density of the boron-doped HIP detectors was found to be thermionic emission limited. HIP detectors with a 0.066 eV were fabricated and characterized using activation energy analysis, corresponding to a 18 micron cutoff wavelength. Photoresponse of the detectors at wavelengths ranging from 2 to 12 microns has been characterized with corresponding quantum efficiencies of 5 - 0.1 percent.

Lin, T. L.↗

Response of Solid He-4 to External Stress: Interdigital Capacitor Solid Level Detector and Optical Interferometer

Two experiments are being conducted to observe the liquid/solid interface of He-4 near 1 K. Interesting instabilities are expected to occur when the solid is non-hydrostatically stressed. (1)A compact interdigital capacitor is used as a level detector to observe solid He-4 to which stresses are applied externally. The capacitor consists of 38 interlaced 50 m wide and 3.8 mm long gold films separated by 50 m and deposited onto a 5 mm by 5 mm sapphire substrate. The capacitor is placed on one flat end wall of a cylindrical chamber (xx mm diameter and xx mm long). The solid is grown to a known height and a stress is applied by a tubular PZT along the cylindrical axis. The observed small change in height of the solid at the wall is linearly proportional to the applied stress. The solid height decreases under compressive stress but does not change under tensile stress. The response of the solid on compressive stress is consistent with the expected quadratic dependence on strain. (2)Interferometric techniques are being developed for observing the solid He-4 surface profile. A laser light source is brought into the low temperature region via single mode optical fiber. The interference pattern is transmitted back out of the low temperature apparatus via optical fiber bundle. The solid He-4 growth chamber will be equipped with two PZT's such that stress can be applied from orthogonal directions. Orthogonally applied stress is expected to induce surface instability with island-like deformation on a grid pattern. Apparatus design and progress of its construction are described.

Fay, J.↗

Neutrino Interactions

The neutrino group of the University of Tennessee, Knoxville was involved from 05/01/2013 to 04/30/2015 in the neutrino physics research funded by DOE-HEP grant DE-SC0009861. Contributions were made to the Double Chooz nuclear reactor experiment in France where second detector was commissioned during this period and final series of measurements has been started. Although Double Chooz was smaller experimental effort than competitive Daya Bay and RENO experiments, its several advantages make it valuable for understanding of systematic errors in measurements of neutrino oscillations. Double Chooz was the first experiment among competing three that produced initial result for neutrino angle θ 13 measurement, giving other experiments the chance to improve measured value statistically. Graduate student Ben Rybolt defended his PhD thesis on the results of Double Chooz experiment in 2015. UT group has fulfilled all the construction and analysis commitments to Double Chooz experiment, and has withdrawn from the collaboration by the end of the mentioned period to start another experiment. Larger effort of UT neutrino group during this period was devoted to the participation in another DOE-HEP project - NOvA experiment. The 14,000-ton "FAR" neutrino detector was commissioned in northern Minnesota in 2014 together with 300-ton "NEAR" detector located at Fermilab. Following that, the physics measurement program has started when Fermilab accelerator complex produced the high-intensity neutrino beam propagating through Earth to detector in MInnessota. UT group contributed to NOvA detector construction and developments in several aspects. Our Research Associate Athanasios Hatzikoutelis was managing (Level 3 manager) the construction of the Detector Control System. This work was successfully accomplished in time with the commissioning of the detectors. Group was involved in the development of the on-line software and study of the signatures of the cosmic ray backgrounds. Flumerfelt and another graduate student Philip Mason were also studying the non-linearity properties of the NOvA liquid scintillator - information that will be essential at the final stages of NOvA data analysis. Philip Mason also studied the response of the FAR NOvA detector in correlation with solar flares. Flumerfelt and Mason successfully defended their PhD in 2015. Also, undergraduate student Cameron Blake Erickson has defended his undergraduate thesis on the NOvA liquid scintillator studies with Compton gamma spectrometer at UT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials

SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antiproton Trapping for Advanced Space Propulsion Applications

The Summary of Research parallels the Statement of Work (Appendix I) submitted with the proposal, and funded effective Feb. 1, 1997 for one year. A proposal was submitted to CERN in October, 1996 to carry out an experiment on the synthesis and study of fundamental properties of atomic antihydrogen. Since confined atomic antihydrogen is potentially the most powerful and elegant source of propulsion energy known, its confinement and properties are of great interest to the space propulsion community. Appendix II includes an article published in the technical magazine Compressed Air, June 1997, which describes CERN antiproton facilities, and ATHENA. During the period of this grant, Prof. Michael Holzscheiter served as spokesman for ATHENA and, in collaboration with Prof. Gerald Smith, worked on the development of the antiproton confinement trap, which is an important part of the ATHENA experiment. Appendix III includes a progress report submitted to CERN on March 12, 1997 concerning development of the ATHENA detector. Section 4.1 reviews technical responsibilities within the ATHENA collaboration, including the Antiproton System, headed by Prof. Holzscheiter. The collaboration was advised (see Appendix IV) on June 13, 1997 that the CERN Research Board had approved ATHENA for operation at the new Antiproton Decelerator (AD), presently under construction. First antiproton beams are expected to be delivered to experiments in about one year. Progress toward assembly of the ATHENA detector and initial testing expected in 1999 has been excellent. Appendix V includes a copy of the minutes of the most recently documented collaboration meeting held at CERN of October 24, 1997, which provides more information on development of systems, including the antiproton trapping apparatus. On February 10, 1998 Prof. Smith gave a 3 hour lecture on the Physics of Antimatter, as part of the Physics for the Third Millennium Lecture Series held at MSFC. Included in Appendix VI are notes and graphs presented on the ATHENA experiment. Portable antiproton trap has been under development. The goal is to store and transport antiprotons from a production site, such as Fermilab near Chicago, to a distant site, such as Huntsville, AL, thus demonstrating the portability of antiprotons.

Smith, Gerald A.↗

Radar Level Measurement in the Presence of Foam Using an LAW High Bound Pretreated Waste Simulant

During previous testing with LAW simulants, the radar level detector, installed in a scale WTP LAW CRV tank at the VSL, worked well when the tank was being mixed. However, if the agitator was stopped and foam was present on the surface, then the radar detector measured the distance to the top of the foam, not the liquid level beneath the foam. This finding has a significant impact on the WTP because if the foam is thick enough, this will cause a high-biased level reading which could affect the composition of the melter feed because too much GFCs would be added to the tank. To address the response of the radar level detector to foam, a Test Exception was issued to perform additional testing that would determine whether the radar level detector signal can be adjusted such that it can identify the foam and liquid levels and reliably operate in the presence of foam on the surface of the slurry. This final report provides results of the testing that was performed with the radar level detector in the presence of foam on the liquid surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced detector signal acquisition and electron beam scanning for high resolution SEM imaging

We report the advancement of materials science at the mesoscale requires improvements in both sampling volumes/areas and spatial resolution in order to make statistically significant measurements of microstructures that influence higher-order material properties, such as fatigue and fracture. Therefore, SEM-based techniques have become desirable due to improvements in imaging resolution, large sample handling capability, and flexibility for in-situ instrumentation. By using fast sampling of SEM electron detector signals, intrinsic beam scanning defects have been identified that are related to the response time of the SEM electron beam deflectors and electron detectors. Mitigation of these beam scanning defects using detector sampling approaches and an adaptive model for settling time is shown to produce higher resolution SEM images, at faster image acquisition times, with a means to quantify the different response functions for various beam deflectors and detectors including those for electrons and ions.

47 OTHER INSTRUMENTATION↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Gamma-Ray Response of Semi-Insulating CdMnTe Crystals

Semi-insulating Cd{sub 0.9}Mn{sub 0.1}Te:In crystals are grown by vertical Bridgman method. The segregation coefficient of Mn in CdTe is nearly 1 so that all the CdMnTe samples obtained from one ingot have nearly a same Mn composition. Also sulfur-based passivation effectively prevent the formation of Te-oxide but large amount of Mn exist as a MnO on the CdMnTe surface. The resistivity of CdMnTe samples are low 10{sup 10} Omegacm and well resolved {sup 241}Am gamma peaks are seen for all detectors. The difference in spectral response can be attributed to the effect of excess Te and conductivity change due to over-compensation induced by indium segregation in CdMnTe. The mobility-lifetime products evaluated from the dependence of peak location on the bias voltage are 1 times 10{sup -3} cm{sup 2}/V. The higher mobility-lifetime products in our CdMnTe crystals than other previous reports are assumed due to minimization of impurity contents in MnTe by several zone refining process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncooled Micro-Cantilever Infrared Imager Optimization

We report on the development, fabrication and characterization of microcantilever based uncooled focal plane array (FPA) for infrared imaging. By combining a streamlined design of microcantilever thermal transducers with a highly efficient optical readout, we minimized the fabrication complexity while achieving a competitive level of imaging performance. The microcantilever FPAs were fabricated using a straightforward fabrication process that involved only three photolithographic steps (i.e. three masks). A designed and constructed prototype of an IR imager employed a simple optical readout based on a noncoherent low-power light source. The main figures of merit of the IR imager were found to be comparable to those of uncooled MEMS infrared detectors with substantially higher degree of fabrication complexity. In particular, the NETD and the response time of the implemented MEMS IR detector were measured to be as low as 0.5K and 6 ms, respectively. The potential of the implemented designs can also be concluded from the fact that the constructed prototype enabled IR imaging of close to room temperature objects without the use of any advanced data processing. The most unique and practically valuable feature of the implemented FPAs, however, is their scalability to high resolution formats, such as 2000 x 2000, without progressively growing device complexity and cost. The overall technical objective of the proposed work was to develop uncooled infrared arrays based on micromechanical sensors. Currently used miniature sensors use a number of different readout techniques to accomplish the sensing. The use of optical readout techniques sensing require the deposition of thin coatings on the surface of micromechanical thermal detectors. Oak Ridge National Laboratory (ORNL) is uniquely qualified to perform the required research and development (R&D) services that will assist our ongoing activities. Over the past decade ORNL has developed a number of unique methods and techniques that led to improved sensors using a number of different approaches.

47 OTHER INSTRUMENTATION↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

Optical detector calibrator system

An optical detector calibrator system simulates a source of optical radiation to which a detector to be calibrated is responsive. A light source selected to emit radiation in a range of wavelengths corresponding to the spectral signature of the source is disposed within a housing containing a microprocessor for controlling the light source and other system elements. An adjustable iris and a multiple aperture filter wheel are provided for controlling the intensity of radiation emitted from the housing by the light source to adjust the simulated distance between the light source and the detector to be calibrated. The geared iris has an aperture whose size is adjustable by means of a first stepper motor controlled by the microprocessor. The multiple aperture filter wheel contains neutral density filters of different attenuation levels which are selectively positioned in the path of the emitted radiation by a second stepper motor that is also controlled by the microprocessor. An operator can select a number of detector tests including range, maximum and minimum sensitivity, and basic functionality. During the range test, the geared iris and filter wheel are repeatedly adjusted by the microprocessor as necessary to simulate an incrementally increasing simulated source distance. A light source calibration subsystem is incorporated in the system which insures that the intensity of the light source is maintained at a constant level over time.

Strobel, James P.↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗