Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Lakeland Habitat for Humanity

This is a case study of the Lakeland, FLorida, Habitat for Humanity affiliate, which has partnered with DOE's Building America program to homes that achieve energy savings of 30% or more over the Building America baseline home (a home built to the 1993 Model Energy Code). The article includes a description of the energy-efficiency features used. The Lakeland affiliate built several of its homes with ducts in conditioned space, which minimizes heat losses and gains. They also used high-efficiency SEER 14 air conditioners; radiant barriers in the roof to keep attics cooler; above-code high-performance dual-pane vinyl-framed low-emissivity windows; a passive fresh air duct to the air handler; and duct blaster and blower door testing of every home to ensure the home's air tightness. This case study was also prepared as a flier titled "High Performance Builder Spotlight: Lakeland Habitat for Humanity, Lakeland, Florida,: which was cleared as PNNL-SA-59068 and distributed at the International Builders’ Show Feb 13-16, 2008, in Orlando, Florida.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Differentiating IgG4-related sclerosing cholangiopathy from cholangiocarcinoma using CT and MRI: experience from a tertiary referring center

Purpose: To compare the cross-sectional imaging findings of immunoglobulin G4-related sclerosing cholangiopathy (IgG4-SC) and cholangiocarcinoma (CCA). Methods: Retrospective search of radiology and pathology databases identified 24 patients with IgG4-SC and over 500 patients with CCA from January 2009 to December 2016. Patients with no pre-treatment imaging studies available on PACS, non-contrasted imaging only, presence of mass lesions, metastatic disease or biliary stents were excluded. 17 patients with IgG4-SC and a selected group of 20 (age and gender matched) patients with CCA were obtained. Images were blinded and independently reviewed by two radiologists. Differences in proportions and means between groups were analyzed using Fishers and Mann–Whitney tests, respectively. Results: Both readers identified a statistically significant difference in the presence of abrupt common bile duct narrowing between IgG4-SC and CCA (6.7% vs. 68.4%, p < 0.001; 33.3% vs. 75%, p = 0.019). No difference was seen in biliary wall thickening, wall enhancement, extrahepatic exclusive location of disease, or pancreatic duct dilation. Inter-observer variability was κ = 0.52. Total bilirubin and CA 19-9 were unable to differentiate between IgG4-SC and CCA. Serum IgG4 was positive in two of six IgG4-SC patients who were tested. Conclusion: IgG4-SC and CCA share many clinical and imaging findings on CT and MRI. Abrupt bile duct cut sign strongly favors CCA. In the absence of this finding, IgG4-SC should be considered in the differential diagnosis in all cases of suspected extrahepatic CCA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Newly Designed Y-configured Single-Catheter Stenting for the Treatment of Hilar-Type Nonanastomotic Biliary Strictures After Orthotopic Liver Transplantation

Purpose: This study was designed to introduce our novel technique of percutaneous single catheter placement into the hilar bile ducts strictures while fulfilling the purpose of bilateral biliary drainage and stenting. We investigated the efficacy and safety of the technique for the treatment of hilar nonanastomotic biliary strictures. Methods: Ten patients who were post-orthotopic liver transplantation between July 2000 and July 2010 were enrolled in this study. Percutaneous Y-configured single-catheter stenting for bilateral bile ducts combined with balloon dilation was designed as the main treatment approach. Technical success rate, clinical indicators, complications, and recurrent rate were analyzed. Results: Technical success rate was 100%. Nine of the ten patients had biochemical normalization, cholangiographic improvement, and clinical symptoms relief. None of them experienced recurrence in a median follow-up of 26 months after completion of therapy and removal of all catheters. Complications were minor and limited to two patients. The one treatment failure underwent a second liver transplantation but died of multiple system organ failure. Conclusions: Percutaneous transhepatic Y-configured single-catheter stenting into the hilar bile ducts is technically feasible. The preliminary trial of this technique combined with traditional PTCD or choledochoscopy for the treatment of hilar biliary strictures after orthotopic liver transplantation appeared to be effective and safe. Yet, further investigation is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intermedilysin induces EGR-1 expression through calcineurin/NFAT pathway in human cholangiocellular carcinoma cells

Research highlights: {yields} ILY leads to the accumulation of [Ca{sup 2+}]i in the nucleus in HuCCT1 cells. {yields} ILY induced activation of NFAT1 through a calcineurin-dependent pathway. {yields} Calcineuri/NFAT pathway is involved in EGR-1 expression in response to ILY treatment. -- Abstract: Intermedilysin (ILY) is a cholesterol-dependent cytolysin produced by Streptococcus intermedius, which is associated with human brain and liver abscesses. Although intrahepatic bile duct cells play a valuable role in the pathogenesis of liver abscess, the molecular mechanism of ILY-treated intrahepatic bile duct cells remains unknown. In this study, we report that ILY induced a nuclear accumulation of intracellular calcium ([Ca{sup 2+}]i) in human cholangiocellular cells HuCCT1. We also demonstrate that 10 ng/ml ILY induced NFAT1 dephosphorylation and its nuclear translocation in HuCCT1 cells. In contrast to the result that ILY induced NF-{kappa}B translocation in human hepatic HepG2 cells, ILY did not affect NF-{kappa}B localization in HuCCT1 cells. Dephosphorylation and nuclear translocation of NFAT1 caused by ILY were prevented by [Ca{sup 2+}]i calcium chelator, BAPTA/AM, and calcineurin inhibitors, cyclosporine A and tacrolimus. ILY induced early growth response-1 (EGR-1) expression and it was inhibited by the pre-treatment with cyclosporine A, indicating that the calcineurin/NFAT pathway was involved in EGR-1 expression in response to ILY. ILY-induced calcineurin/NFAT1 activation and sequential EGR-1 expression might be related to the pathogenesis of S. intermedius in human bile duct cells.

60 APPLIED LIFE SCIENCES↗

CREB is a regulatory target for the protein kinase Akt/PKB in the differentiation of pancreatic ductal cells into islet {beta}-cells mediated by hepatocyte growth factor

Research highlights: {yields} CREB is a regulatory target for the protein kinase Akt/PKB in pancreatic duct cells. {yields} Activation of the PI3K/AKT/CREB pathway plays a critical role in the HGF-mediated differentiation of pancreatic duct cells in vivo. {yields} CREB was causally linked to the expression of transcription factors during PDEC differentiation induced by HGF. -- Abstract: We have previously reported that the PI3K/Akt signaling pathway is involved in hepatocyte growth factor (HGF)-induced differentiation of adult rat pancreatic ductal epithelial cells (PDECs) into islet {beta}-cells in vitro. The transcription factor CREB is one of the downstream key effectors of the PI3K/Akt signaling pathway. Recent studies showing that CREB is required for the survival of certain cell types prompted us to examine whether CREB is a nuclear target for activation via the HGF-dependent Ser/Thr kinase Akt/PKB in the differentiation of pancreatic duct cell into islet {beta}-cells. In this study, we first attempted to examine whether HGF modulates the Akt-dependent activation of target gene CREB and then investigated whether CREB activity affects the differentiation of HGF-induced PDECs. Finally, we studied the role of CREB in modulating the expression of transcription factors in PDECs during the differentiation of HGF-induced PDECs. Our results demonstrated that CREB is a regulatory target for the protein kinase Akt/PKB in the differentiation of pancreatic ductal cells into islet {beta}-cells mediated by HGF.

60 APPLIED LIFE SCIENCES↗

Impaired autophagy promotes bile acid-induced hepatic injury and accumulation of ubiquitinated proteins

Highlights: • CDCA, CA and bile duct ligation caused defective autophagic clearance. • CDCA suppressed Beclin-1 expression, which exhibits a higher cytotoxicity than CA. • Pharmacological or genetic inhibition of autophagy enhanced bile acid-induced cell death. • Reduced Beclin-1 expression may lead to higher cytotoxicity of CDCA. Chronic exposure to hydrophobic bile acids such as chenodeoxycholic acid (CDCA) and cholic acid (CA) in the liver during cholestasis causes hepatotoxicity and inflammatory response. However, the detailed mechanisms regarding the role of autophagy in cholestatic hepatotoxicity remain largely unknown. Here we determined autophagic clearance in livers of bile duct-ligated mice, in which bile acids accumulate, and in human hepatoma HepG2 cells treated with CDCA and CA. The accumulation of bile acids caused defective autophagic clearance, shown by the accumulation of insoluble p62 and ubiquitinated proteins and cell death accompanied by caspase-3 processing. Hepatocytes exposed to bile acids also showed the accumulation of autophagosomes via suppressed autophagy flux. Treatment of CDCA markedly suppressed Beclin-1 expression, which exhibits a higher cytotoxicity than CA. Moreover, pharmacological or genetic inhibition of autophagy enhanced bile acid-induced cell death. Finally, in vivo, bile duct ligation led to aberrant accumulation of p62 and ubiquitinated proteins in the liver. Our data demonstrate that inhibited autophagy is an essential component of liver injury during cholestasis.

60 APPLIED LIFE SCIENCES↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

Acceptable Toxicity After Stereotactic Body Radiation Therapy for Liver Tumors Adjacent to the Central Biliary System

Purpose: To evaluate biliary toxicity after stereotactic body radiation therapy (SBRT) for liver tumors. Methods and Materials: Among 297 consecutive patients with liver tumors treated with SBRT of 35 to 50 Gy in 5 fractions, patients who were irradiated with >20 Gy to the central biliary system (CBS), including the gallbladder, and had follow-up times >6 months were retrospectively analyzed. Toxicity profiles, such as clinical symptoms and laboratory and radiologic data especially for obstructive jaundice and biliary infection, were investigated in relation to the dose volume and length relationship for each biliary organ. Results: Fifty patients with 55 tumors were irradiated with >20 Gy to the CBS. The median follow-up period was 18.2 months (range, 6.0-80.5 months). In the dose length analysis, 39, 34, 14, and 2 patients were irradiated with >20 Gy, >30 Gy, >40 Gy, and >50 Gy, respectively, to >1 cm of the biliary tract. Seven patients were irradiated with >20 Gy to >20% of the gallbladder. Only 2 patients experienced asymptomatic bile duct stenosis. One patient, metachronously treated twice with SBRT for tumors adjacent to each other, had a transient increase in hepatic and biliary enzymes 12 months after the second treatment. The high-dose area >80 Gy corresponded to the biliary stenosis region. The other patient experienced biliary stenosis 5 months after SBRT and had no laboratory changes. The biliary tract irradiated with >20 Gy was 7 mm and did not correspond to the bile duct stenosis region. No obstructive jaundice or biliary infection was found in any patient. Conclusions: SBRT for liver tumors adjacent to the CBS was feasible with minimal biliary toxicity. Only 1 patient had exceptional radiation-induced bile duct stenosis. For liver tumors adjacent to the CBS without other effective treatment options, SBRT at a dose of 40 Gy in 5 fractions is a safe treatment with regard to biliary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A computationally efficient method for full-core conjugate heat transfer modeling of sodium fast reactors

For efficient and accurate temperature predictions of sodium fast reactor structures, a 3-D full-core conjugate heat transfer modeling capability is developed for an advanced system analysis tool, SAM. The hexagon lattice core is modeled with 1-D parallel channels representing the subassembly flow, and 2-D duct walls and inter-assembly gaps. The six sides of the hexagon duct wall and near-wall coolant region are modeled separately to account for different temperatures and heat transfer between coolant flow and each side of the duct wall. The Jacobian Free Newton Krylov (JFNK) solution method is applied to solve the fluid and solid field simultaneously in a fully coupled fashion. The 3-D full-core conjugate heat transfer modeling capability in SAM has been demonstrated by a verification test problem with 7 fuel assemblies in a hexagon lattice layout. In addition, the SAM simulation results are compared with RANS-based CFD simulations. Very good agreements have been achieved between the results of the two approaches.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

VLF Technique and Science in India

Since IGY period (1957-58), natural and artificially produced Very Low Frequency (VLF) electromagnetic radiations are being recorded at large number of ground stations and on board satellites to study various wave-plasma interactive phenomena. The terrestrial propagation of these VLF radio waves are primarily enabled through the earth ionosphere wave guide (EIWG) system to long horizontal distances around the globe and ducted along the geomagnetic field lines into the conjugate hemisphere through the ionosphere-plasmasphere-magnetosphere routes. The time frequency spectra indicate presence of dispersion and various cut-off frequencies providing several types of received signals like whistlers, chorus, tweeks, hiss, hisslers etc., which can be heard on an earphone with distinguishing audio structures. While the VLF technique has been a very effective tool for studying middle and high latitude phenomena, the importance of various anomalous characteristics over the Indian low latitude stations provide potentially new challenges for their scientific interpretation and modelling. The ducted and non-ducted propagation, low latitude TRIMPI/TLE effects, D-region ionisation perturbations due to solar and stellar x- and {gamma} ray emissions and detecting precursors of seismic activities are a few problems which will gain from low latitude studies. Since the conjugate points of Indian stations lie over the Indian oceanic region, the VLF propagation effects would be relatively noise free to observe rare and new phenomena requiring better SNR to detect such changes. The VLF signals emanating from the active seismic zones would require high sensitivity of the system and suitable network of transmitting and receiving stations. Results obtained on whistlers and related studies from a number of Indian stations covering geomagnetic latitude range between 13-24 deg. N are mentioned and reviewed in the background of theoretical understanding of the lightning return stroke signal elements, VLF propagation through cold plasma, ionospheric wave guide mode, electron precipitation due to cyclotron resonance and production of ionisation in the D-region due to solar/stellar UV/X/{gamma}-rays. Further use of the VLF technique in terms of improving both observational data for real time monitoring/modelling of geophysical phenomena and exploring space weather conditions are considered as part of a future Indian programme.

58 GEOSCIENCES↗

Modeling the propagation of whistler-mode waves in the presence of field-aligned density irregularities

We present a numerical study of propagation of VLF whistler-mode waves in a laboratory plasma. Our goal is to understand whistler propagation in magnetic field-aligned irregularities (also called channels or ducts). Two cases are examined, that of a high-frequency ({omega}>{Omega}{sub ce}/2) whistler in a density depletion duct and that of a low-frequency ({omega}<{Omega}{sub ce}/2) whistler in a density enhancement. Results from a numerical simulation of whistler wave propagation are compared to data from the UCLA Los Angeles Physics Teachers Alliance Group plasma device and whistler propagation in pre-existing density depletion and density enhancement ducts is demonstrated.

58 GEOSCIENCES↗

Magnetohydrodynamic pressure drop and flow balancing of liquid metal flow in a prototypic fusion blanket manifold

Understanding magnetohydrodynamic (MHD) phenomena associated with the flow of electrically conducting fluids in complex geometry ducts subject to a strong magnetic field is required to effectively design liquid metal (LM) blankets for fusion reactors. Specifically, accurately predicting the 3D MHD pressure drop and flow distribution is important. To explore these topics, we simulate a LM MHD flow through an electrically non-conducting prototypic manifold for a wide range of flow and geometry parameters using a 3D MHD solver, HyPerComp incompressible MHD solver for arbitrary geometry. The reference manifold geometry consists of a rectangular feeding duct which suddenly expands such that the duct thickness in the magnetic field direction abruptly increases by a factor r exp . Downstream of the sudden expansion, the LM is distributed into several parallel channels. As a first step in qualifying the flow, a magnitude of the curl of the induced Lorentz force was used to distinguish between inviscid, irrotational core flows and boundary and internal shear layers where inertia and/or viscous forces are important. Scaling laws have been obtained which characterize the 3D MHD pressure drop and flow balancing as a function of the flow parameters and the manifold geometry. Associated Hartmann and Reynolds numbers in the computations were ~10 3 and ~10 1 -10 3 , respectively, while r exp was varied from 4 to 12. An accurate model for the pressure drop was developed for the first time for inertial-electromagnetic and viscous-electromagnetic regimes based on 96 computed cases. Analysis reflects that flow balance can be improved by lengthening the distance between the manifold inlet and the entrances of the parallel channels by utilizing the effect of flow transitioning to a quasi-two-dimensional state in the expansion region of the manifold.

42 ENGINEERING↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

High contribution of canopy to oleoresin accumulation in loblolly pine trees

The shoot system of all loblolly pine (Pinus taeda L.) contains abundant resin ducts, and the oleoresins contained within them have demonstrated roles in constitutive defenses. This study is providing a quantitative assessment of oleoresin biosynthesis and accumulation in resin ducts. Morphometric analyses of representative tissue sections indicate that the fractional volume of resin ducts is particularly high in the cortex of young stems and their needles, representing a major portion of total pine resins from primary growth of the canopy. We demonstrate that it is possible to extrapolate oleoresin formation from the microscopic scale (tissues sections) to the macroscale (entire trees), which has implications for assessing resins as renewable feedstocks for bioproducts.

Srividya, Narayanan↗