Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISEASE DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Efficacy of perfusion CT in differentiating of pancreatic ductal adenocarcinoma from mass-forming chronic pancreatitis and characterization of isoattenuating pancreatic lesions

Purpose: Multidetector computed tomography (MDCT) is routinely used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases, especially mass-forming chronic pancreatitis (MFCP) and isoattenuating pancreatic lesions. Perfusion CT (pCT) may help resolve this problem. The aim of this study was to evaluate whether pCT could help differentiating PDAC from MFCP and in characterization of isoattenuating pancreatic lesions. Materials and methods: This prospective study included 89 cases of pancreatic lesions detected by MDCT and further analyzed with pCT. Sixty-one cases with final pathological diagnosis PDAC and 12 cases with MFCP were included from the study. Blood volume (BV), blood flow (BF), mean transit time (MTT), and permeability surface area product (PS) maps were obtained. Perfusion values obtained from the lesions and normal parenchyma were compared. Results: Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in PDAC and MFCP (p < 0.05). Compared with MFCP, BV, BF, PS were lower and MTT was longer in PDAC (p < 0.001). Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in isoattenuating lesions, (p < 0.001). Cutoff values of 7.60 mL/100 mL, 64.43 mL/100 mL/min, 28.08 mL/100 mL/min for BV, BF, PS, respectively, provided 100% sensitivity and specificity and 7.47 s for MTT provided 98.3% sensitivity, 80% specificity for distinguishing PDAC from MFCP. Conclusion: pCT is a useful technology that can be helpful in overcoming the limitations of routine MDCT in diagnosing PDAC and characterization of isoattenuating lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair

PurposeTo assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR).Materials and MethodsWe performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks.ResultsData were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of <0.638 or ≥0.638, respectively (P = .002).ConclusionPatients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calcium channel blockers ameliorate iron overload-associated hepatic fibrosis by altering iron transport and stellate cell apoptosis

Liver fibrosis is the principal cause of morbidity and mortality in patients with iron overload. Calcium channel blockers (CCBs) can antagonize divalent cation entry into renal and myocardial cells and inhibit fibrogenic gene expression. We investigated the potential of CCBs to resolve iron overload-associated hepatic fibrosis. Kunming mice were assigned to nine groups (n = 8 per group): control, iron overload, deferoxamine, high and low dose verapamil, high and low dose nimodipine, and high and low dose diltiazem. Iron deposition and hepatic fibrosis were measured in mouse livers. Expression levels of molecules associated with transmembrane iron transport were determined by molecular biology approaches. In vitro HSC-T6 cells were randomized into nine groups (the same groups as the mice). Changes in proliferation, apoptosis, and metalloproteinase expression in cells were detected to assess the anti-fibrotic effects of CCBs during iron overload conditions. We found that CCBs reduced hepatic iron content, intracellular iron deposition, the number of hepatic fibrotic areas, collagen expression levels, and hydroxyproline content. CCBs rescued abnormal expression of α1C protein in L-type voltage-dependent calcium channel (LVDCC) and down-regulated divalent metal transporter-1 (DMT-1) expression in mouse livers. In iron-overloaded HSC-T6 cells, CCBs reduced iron deposition, inhibited proliferation, induced apoptosis, and elevated expression of matrix metalloproteinase-13 (MMP-13) and tissue inhibitor of metalloproteinase-1 (TIMP-1). CCBs are potential therapeutic agents that can be used to address hepatic fibrosis during iron overload. They resolve hepatic fibrosis probably correlated with regulating transmembrane iron transport and inhibiting HSC growth. - Highlights: • Calcium channel blockers (CCBs) reduced hepatic iron content. • CCBs decreased hepatic fibrotic areas and collagen expression levels. • CCBs resolve fibrosis by regulating iron transport and inhibiting HSC growth.

60 APPLIED LIFE SCIENCES↗

Role of Systemic Therapy in the Development of Lung Sequelae After Conformal Radiotherapy in Breast Cancer Patients

Purpose: To analyze the risk of radiogenic lung damage in breast cancer patients after conformal radiotherapy and different forms of systemic treatment. Methods and Materials: In 328 patients receiving sequential taxane-based chemotherapy, concomitant hormone therapy (tamoxifen or aromatase inhibitors), or no adjuvant systemic therapy, symptomatic and asymptomatic lung sequelae were prospectively evaluated via the detection of visible CT abnormalities, 3 months or 1 year after the completion of the radiotherapy. Results: Significant positive associations were detected between the development of both pneumonitis and fibrosis of Grade 1 and patient age, ipsilateral mean lung dose, volume of the ipsilateral lung receiving 20 Gy, and irradiation of the regional lymph nodes. In multivariate analysis, age and mean lung dose proved to be independent predictors of early (odds ratio [OR] = 1.035, 95% confidence interval [CI] 1.011-1.061 and OR = 1.113, 95% CI 1.049-1.181, respectively) and late (OR = 1.074, 95% CI 1.042-1.107 and OR = 1.207, 95% CI 1.124-1.295, respectively) radiogenic lung damage, whereas the role of systemic therapy was significant in the development of Grade 1 lung fibrosis (p = 0.01). Among the various forms of systemic therapy, tamoxifen increased the risk of late lung sequelae (OR = 2.442, 95% CI 1.120-5.326, p = 0.025). No interaction was demonstrated between the administration of systemic therapy and the other above-mentioned parameters as regards the risk of radiogenic lung damage. Conclusions: Our analyses demonstrate the independent role of concomitant tamoxifen therapy in the development of radiogenic lung fibrosis but do not suggest such an effect for the other modes of systemic treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Effect of Human Papillomavirus Genotypes in Patients With Cervical Cancer Undergoing Primary Radiotherapy

Purpose: To study the prognostic value of the human papillomavirus (HPV) genotypes in cervical cancer patients undergoing radiotherapy. Patients and Methods: A total of 1,010 patients with cervical cancer after radiotherapy between 1993 and 2000 were eligible for this study. The HPV genotypes were determined by a genechip, which detects 38 types of HPV. The patient characteristics and treatment outcomes were analyzed using the Cox regression hazard model and classification and regression tree decision tree method. Results: A total of 25 genotypes of HPV were detected in 992 specimens (98.2%). The leading 8 types were HPV16, 58, 18, 33, 52, 39, 31, and 45. These types belong to two high-risk HPV species: alpha-7 (HPV18, 39, 45) and alpha-9 (HPV16, 31, 33, 52, 58). Three HPV-based risk groups, which were independent of established prognostic factors, such as International Federation of Gynecology and Obstetrics stage, age, pathologic features, squamous cell carcinoma antigen, and lymph node metastasis, were associated with the survival outcomes. The high-risk group consisted of the patients without HPV infection or the ones infected with the alpha-7 species only. Patients co-infected with the alpha-7 and alpha-9 species belonged to the medium-risk group, and the others were included in the low-risk group. Conclusion: The results of the present study have confirmed the prognostic value of HPV genotypes in cervical cancer treated with radiotherapy. The different effect of the alpha-7 and alpha-9 species on the radiation response deserves additional exploration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation for Pure Ductal Carcinoma in Situ

Purpose: To report outcomes for ductal carcinoma in situ (DCIS) treated with breast-conserving therapy using accelerated partial breast irradiation (APBI). Methods and Materials: From March 2001 to February 2009, 53 patients with Stage 0 breast cancer were treated with breast conserving surgery and adjuvant APBI. Median age was 62 years. All patients underwent excision with margins negative by {>=}1 mm before adjuvant radiotherapy (RT). A total of 39 MammoSite brachytherapy (MS) patients and 14 three-dimensional conformal external beam RT (3DCRT) patients were treated to the lumpectomy bed alone with 34 Gy and 38.5 Gy, respectively. Of the DCIS cases, 94% were mammographically detected. All patients with calcifications had either specimen radiography or postsurgical mammography confirmation of clearance. Median tumor size was 6 mm, and median margin distance was 5 mm. There were no statistically significant differences according to APBI method for race/ethnicity, tumor detection method, tumor grade, estrogen receptor (ER) status, or use of tamoxifen (p = NS). Recurrence and survival were calculated using the Kaplan-Meier method. Cosmesis was scored by the Harvard criteria. Results: With a median follow-up of 3.6 years (range, 0.4-6.3 years), the overall and cause-specific survival rates were 98% and 100%, respectively. Three-year actuarial ipsilateral breast tumor recurrence was 2%. One failure was observed at the resection bed 11 months post-RT. No other elsewhere breast failures, regional recurrences, or distant metastases were noted. Cosmesis was excellent or good in 92.4% of cases, with no statistically significant differences according to the APBI method (92.3% with MammoSite and 92.8% with 3DCRT; p = 0.649). Conclusions: APBI as part of breast-conserving therapy for pure DCIS was associated with excellent local control and survival rates, with the vast majority of patients having good to excellent cosmesis. This finding supports the recent analysis by the American Society of Breast Surgeons on a subset of DCIS patients treated efficaciously with APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Requirement of a dopaminergic neuronal phenotype for toxicity of low concentrations of 1-methyl-4-phenylpyridinium to human cells

LUHMES cells are conditionally-immortalized non-transformed human fetal cells that can be differentiated to acquire a dopaminergic neuron-like phenotype under appropriate growth conditions. After differentiation by GDNF and cyclic adenosine monophosphate, LUHMES were sensitive to 1-methyl-4-phenylpyridinium (MPP{sup +}) toxicity at <= 5 muM, but resistant to the parental compound 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP). The high homogeneity and purity of the cultures allowed the detection of metabolic changes during the degeneration. Cellular ATP dropped in two phases after 24 and 48 h; cellular glutathione (GSH) decreased continuously, paralleled by an increase in lipid peroxidation. These events were accompanied by a time-dependent degeneration of neurites. Block of the dopamine transporter by GBR 12909 or mazindol completely abrogated MPP{sup +} toxicity. Inhibition of de novo dopamine synthesis by alpha-methyl-L-tyrosine or 3-iodo-L-tyrosine attenuated toxicity, but did not reduce the initial drop in ATP. Inhibition of mixed lineage kinases by CEP1347 completely prevented the MPP{sup +}-induced loss of viability and intracellular GSH, but failed to attenuate the initial drop of ATP. For the quantitative assessment of neurite degeneration, an automated imaging-based high content screening approach was applied and confirmed the findings made by pharmacological interventions in this study. Our data indicate that inhibition of mitochondrial ATP synthesis is not sufficient to trigger cell death in MPP{sup +}-treated LUHMES.

60 APPLIED LIFE SCIENCES↗

Differences in Supratentorial Damage of White Matter in Pediatric Survivors of Posterior Fossa Tumors With and Without Adjuvant Treatment as Detected by Magnetic Resonance Diffusion Tensor Imaging

Purpose: To elucidate morphologic correlates of brain dysfunction in pediatric survivors of posterior fossa tumors by using magnetic resonance diffusion tensor imaging (DTI) to examine neuroaxonal integrity in white matter. Patients and Methods: Seventeen medulloblastoma (MB) patients who had received surgery and adjuvant treatment, 13 pilocytic astrocytoma (PA) patients who had been treated only with surgery, and age-matched healthy control subjects underwent magnetic resonance imaging on a 3-Tesla system. High-resolution conventional T1- and T2-weighted magnetic resonance imaging and DTI data sets were obtained. Fractional anisotropy (FA) maps were analyzed using tract-based spatial statistics, a part of the Functional MRI of the Brain Software Library. Results: Compared with control subjects, FA values of MB patients were significantly decreased in the cerebellar midline structures, in the frontal lobes, and in the callosal body. Fractional anisotropy values of the PA patients were not only decreased in cerebellar hemispheric structures as expected, but also in supratentorial parts of the brain, with a distribution similar to that in MB patients. However, the amount of significantly decreased FA was greater in MB than in PA patients, underscoring the aggravating neurotoxic effect of the adjuvant treatment. Conclusions: Neurotoxic mechanisms that are present in PA patients (e.g., internal hydrocephalus and damaged cerebellar structures affecting neuronal circuits) contribute significantly to the alteration of supratentorial white matter in pediatric posterior fossa tumor patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dietary administration of sodium arsenite to rats: Relations between dose and urinary concentrations of methylated and thio-metabolites and effects on the rat urinary bladder epithelium

Based on epidemiological data, chronic exposure to high levels of inorganic arsenic in drinking water is carcinogenic to humans, inducing skin, urinary bladder and lung tumors. In vivo, inorganic arsenic is metabolized to organic methylated arsenicals including the highly toxic dimethylarsinous acid (DMA{sup III}) and monomethylarsonous acid (MMA{sup III}). Short-term treatment of rats with 100 mug/g trivalent arsenic (As{sup III}) as sodium arsenite in the diet or in drinking water induced cytotoxicity and necrosis of the urothelial superficial layer, with increased cell proliferation and hyperplasia. The objectives of this study were to determine if these arsenic-induced urothelial effects are dose responsive, the dose of arsenic at which urothelial effects are not detected, and the urinary concentrations of the arsenical metabolites. We treated female F344 rats for 5 weeks with sodium arsenite at dietary doses of 0, 1, 10, 25, 50, and 100 ppm. Cytotoxicity, cell proliferation and hyperplasia of urothelial superficial cells were increased in a dose-responsive manner, with maximum effects found at 50 ppm As{sup III}. There were no effects at 1 ppm As{sup III}. The main urinary arsenical in As{sup III}-treated rats was the organic arsenical dimethylarsinic acid (DMA{sup V}). The thio-metabolites dimethylmonothioarsinic acid (DMMTA{sup V}) and monomethylmonothioarsinic acid (MMMTA{sup V}) were also found in the urine of As{sup III}-treated rats. The LC{sub 50} concentrations of DMMTA{sup V} for rat and human urothelial cells in vitro were similar to trivalent oxygen-containing arsenicals. These data suggest that dietary As{sup III}-induced urothelial cytotoxicity and proliferation are dose responsive, and the urothelial effects have a threshold corresponding to the urinary excretion of measurable reactive metabolites.

60 APPLIED LIFE SCIENCES↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

MUS81 is associated with cell proliferation and cisplatin sensitivity in serous ovarian cancer

The dysfunction of DNA damage repair (DDR) pathway contributes to tumorigenesis and drug-resistance in cancer. MUS81 is a member of the conserved xeroderma pigmentosum group F (XPF) family protein of endonucleases, which is important to the DDR pathway. However, the role of MUS81 in the development of ovarian cancer remains uncertain. To explore the expression of MUS81 and its association to serous ovarian cancer (SOC), 43 biopsies of SOC patients were detected by qRT-PCR, and 29 specimens were further performed by immunohistochemistry analysis. Here, we observed that MUS81 was over-expressed in SOC tissues at both transcript and protein levels, and the expression level of MUS81 protein in ovarian cancer cell lines was also higher than that in human normal ovarian surface epithelial cell line (HOSEpiC). We also found that down-regulation of MUS81 expression in ovarian cancer cells inhibited cell proliferation and colony formation ability, and influenced cell cycle progression. Moreover, inhibition of MUS81 expression induced cellular senescence and enhanced the antitumor effect of cisplatin. Down-regulation of MUS81 expression could suppress the growth and development of SOC. These results indicate that MUS81 might play important roles in the progression of SOC and influence the antitumor effect of cisplatin. - Highlights: • MUS81 was overexpression in serous ovarian cancer (SOC). • Meanwhile down-regulation of inhibited cell proliferation and influenced cell cycle progression. • Inhibition of MUS81 induced cell cellular senescence and enhanced the antitumor effect of cisplatin. • Down-regulation of MUS81 expression could suppress the growth and development of SOC.

60 APPLIED LIFE SCIENCES↗

Photodynamic Cancer Therapy - Recent Advances

The basic principle of the photodynamic effect was discovered over a hundred years ago leading to the pioneering work on PDT in Europe. It was only during the 1980s, however, when 'photoradiation therapy' was investigated as a possible treatment modality for cancer. Photodynamic therapy (PDT) is a photochemotherapeutic process which requires the use of a photosensitizer (PS) that, upon entry into a cancer cell is targeted by laser irradiation to initiate a series of events that contribute to cell death. PSs are light-sensitive dyes activated by a light source at a specific wavelength and can be classified as first or second generation PSs based on its origin and synthetic pathway. The principle of PS activation lies in a photochemical reaction resulting from excitation of the PS producing singlet oxygen which in turn reacts and damages cell organelles and biomolecules required for cell function and ultimately leading to cell destruction. Several first and second generation PSs have been studied in several different cancer types in the quest to optimize treatment. PSs including haematoporphyrin derivative (HpD), aminolevulinic acid (ALA), chlorins, bacteriochlorins, phthalocyanines, naphthalocyanines, pheophorbiedes and purpurins all require selective uptake and retention by cancer cells prior to activation by a light source and subsequent cell death induction. Photodynamic diagnosis (PDD) is based on the fluorescence effect exhibited by PSs upon irradiation and is often used concurrently with PDT to detect and locate tumours. Both laser and light emitting diodes (LED) have been used for PDT depending on the location of the tumour. Internal cancers more often require the use of laser light delivery using fibre optics as delivery system while external PDT often make use of LEDs. Normal cells have a lower uptake of the PS in comparison to tumour cells, however the acute cytotoxic effect of the compound on the recovery rate of normal cells is not known. Subcellular localization of PS is of vital importance when cell death mechanism is identified. Programmed cell death (PCD) viz. apoptosis, necrosis and autophagy have all been identified as inducible cell death mechanisms during PDT. While apoptosis is probably the preferred cell death mechanism, understanding the molecular differences and identifying the cross-talk between these mechanisms are crucial to the development of new PSs aimed at improving the killing efficiency and overall effectiveness of PDT as a cancer treatment modality. This paper reviews the process of PDT cancer therapy, the available PSs, their effectiveness for different cancers as well as the cell death mechanisms identified during PDT of different cancers associated with specific PSs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Ki-67 Staining Levels as an Independent Biomarker of Biochemical Recurrence After Salvage Radiation Therapy for Prostate Cancer

Purpose: We recently published a scoring algorithm to predict biochemical recurrence (BCR) after salvage radiation therapy (SRT) for prostate cancer. Currently, this algorithm is based on clinicopathologic features and does not incorporate information from tumor-based biomarkers. Herein, we evaluate the ability of Ki-67 staining in primary prostate cancer to independently aid in the prediction of BCR among men undergoing SRT. Methods and Materials: We identified 147 patients who were treated with SRT between July 1987 and July 2003 at Mayo Clinic (Rochester, MN; Jacksonville, FL; Scottsdale, AZ). Staining levels of Ki-67 in primary tumor samples were detected by use of a monoclonal antibody and quantified by use of a computer-assisted method. We used Cox proportional hazards models to examine the association of Ki-67 staining and BCR in single-variable models and after multivariable adjustment. Results: The risk of BCR for men with tumors in the highest tertile of Ki-67 staining is approximately two times that for men with tumors in the lower two tertiles (relative risk, 2.02; 95% confidence interval, 1.23-3.32; p = 0.005) after adjustment for the features in our original scoring algorithm. Further adjustment for additional covariates did not attenuate this association. Evidence from concordance index values supports that Ki-67 staining adds to the predictive ability of our existing scoring algorithm. Conclusions: Our data suggest that higher levels of Ki-67 staining are associated with increased risk of BCR after SRT, independent of existing clinicopathologic covariates. Future studies involving larger numbers of patients are required to validate these results and also explore possible means of combining this biomarker with existing prognostic tools.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

c-Jun N-terminal kinase modulates oxidant stress and peroxynitrite formation independent of inducible nitric oxide synthase in acetaminophen hepatotoxicity

Acetaminophen (APAP) overdose, which causes liver injury in animals and humans, activates c-jun N-terminal kinase (JNK). Although it was shown that the JNK inhibitor SP600125 effectively reduced APAP hepatotoxicity, the mechanisms of protection remain unclear. C57Bl/6 mice were treated with 10 mg/kg SP600125 or vehicle (8% dimethylsulfoxide) 1 h before 600 mg/kg APAP administration. APAP time-dependently induced JNK activation (detected by JNK phosphorylation). SP600125, but not the vehicle, reduced JNK activation, attenuated mitochondrial Bax translocation and prevented the mitochondrial release of apoptosis-inducing factor at 4-12 h. Nuclear DNA fragmentation, nitrotyrosine staining, tissue GSSG levels and liver injury (plasma ALT release and necrosis) were partially attenuated by the vehicle (- 65%) and completely eliminated by SP600125 (- 98%) at 6 and 12 h. Furthermore, SP600125 attenuated the increase of inducible nitric oxide synthase (iNOS) mRNA and protein. However, APAP did not enhance plasma nitrite + nitrate levels (NO formation); SP600125 had no effect on this parameter. The iNOS inhibitor L-NIL did not reduce NO formation or injury after APAP but prevented NO formation caused by endotoxin. Since SP600125 completely eliminated the increase in hepatic GSSG levels, an indicator of mitochondrial oxidant stress, it is concluded that the inhibition of peroxynitrite was mainly caused by reduced superoxide formation. Our data suggest that the JNK inhibitor SP600125 protects against APAP-induced liver injury in part by attenuation of mitochondrial Bax translocation but mainly by preventing mitochondrial oxidant stress and peroxynitrite formation and thereby preventing the mitochondrial permeability transition pore opening, a key event in APAP-induced cell necrosis.

60 APPLIED LIFE SCIENCES↗