Position-Sensitive Spectrometric Module for Detecting Ionizing Radiation by Semiconductor Strip Detectors

A position-sensitive module for detecting ionizing radiation based on semiconductor strip detectors and a multichannel spectrometric route has been developed and implemented. The dynamic range of the detected charge generated by an ionizing particle in the detector is 5–250 fC. The position-sensitive module is a structurally complete device with the functions of amplifying the spectrometric signal, digitizing, buffering, preprocessing, and transmitting data to a computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dotted-line FLEET for two-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) is a powerful unseeded velocimetry technique typically used to measure one component of velocity along a line, or two or three components from a dot. In this Letter, we demonstrate a dotted-line FLEET technique which combines the dense profile capability of a line with the ability to perform two-component velocimetry with a single camera on a dot. Our set-up uses a single beam path to create multiple simultaneous spots, more than previously achieved in other FLEET spot configurations. We perform dotted-line FLEET measurements downstream of a highly turbulent, supersonic nitrogen free jet. Dotted-line FLEET is created by focusing light transmitted by a periodic mask with rectangular slits of 1.6 × 40 mm 2 and an edge-to-edge spacing of 0.5 mm, then focusing the imaged light at the measurement region. Up to seven symmetric dots spaced approximately 0.9 mm apart, with mean full-width at half maximum diameters between 150 and 350 µm, are simultaneously imaged. Both streamwise and radial velocities are computed and presented in this Letter.

47 OTHER INSTRUMENTATION↗

A Molecular-MNIST Dataset for Machine Learning Study on Diffraction Imaging and Microscopy

An image dataset of 10 different size molecules, where each molecule has 2,000 structural variants, is generated from the 2D cross-sectional projection of Molecular Dynamics trajectories. The purpose of this dataset is to provide a benchmark dataset for the increasing need of machine learning, deep learning and image processing on the study of scattering, imaging and microscopy.

BASIC BIOLOGICAL SCIENCES,OTHER INSTRUMENTATION↗

A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

42 ENGINEERING↗

Safeguards Technology Factsheet - Unattended Dual Current Monitor (UDCM)

The UDCM is a low-current measurement device designed to record sub-nano-amp to micro-amp currents from radiation detectors. The UDCM is a two-channel device that incorporates a Commercial-Off-The-Shelf (COTS) processor enabling both serial over USB as well as Ethernet communications. The instrument includes microSD and USB flash memory for data storage as well as a programmable High Voltage (HV) power supply for detector bias. The UDCM is packaged in the same enclosure, employs the same processor and has a similar user interface as the UMSR. A serial over USB communication line to the UDCM allows the use of existing versions of MIC software, while the Ethernet port is compatible with the new IAEA RAINSTORM communication protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source Physics Experiment Data Quality Using Background Noise

We computed time-domain root-mean-square (TRMS) amplitudes and power spectral densities (PSD) from the Source Physics Experiment (SPE) seismic data using the 2018 version 1.4 of the instrument response metadata. The geophone instrument gains were set lower about a few weeks prior to the SPE shots to record on-scale and then reset soon afterward to record background noise and seismicity. When the gains were set lower, we determined that the 1-2 Hz bandpass filtered geophone amplitudes increased 20 decibels (dB) or factor of 10 relative to the geophone baseline or background noise levels from nearby broadband sensors. This indicates an inconsistency between the released metadata reporting a decrease in gain factor of 32 and the likely true geophone gain setting of 3.2. After the shots, the geophone gains were reset and recorded background noise levels similar to nearby broadbands consistent with the metadata for those time intervals. There was also a similar issue with line-3, line-4 and AF Trillium broadband horizontals gains during SPE-5 where there is a factor of 32 difference relative to baseline levels. The other Guralp and Trillium broadbands performed very well recording a 1-2 Hz noise level of -150 to -160 dB similar to the nearby station at Tonopah Springs, Nevada (US.TPNV) and compared with -170 dB from the new low noise model (NLNM) for the continental US (e.g., McNamara and Buland, 2004). The geophones were only 5-10 dB higher but performed as well as broadbands above 6 Hz. The accelerometers have poor low frequency response and were 40-50 dB higher in the 1-2 Hz band relative to broadbands.

58 GEOSCIENCES↗

5G Enabled Energy Innovation: Advanced Wireless Networks for Science

Digital wireless communication has become a foundational technology for the nation. The U.S. Department of Energy’s Office of Science (DOE-SC) is the Nation’s largest supporter of basic research in the physical sciences discovering new materials, designing advanced microelectronics, and understanding the physics of radio frequency signaling. The expanding national rollout of a new fifth-generation (5G) mobile network, coupled with the torrent of scientific data generated by next-generation devices such as battery-powered Internet of Things (IoT) sensors, has created an urgent need to enhance cutting-edge wireless technology. Breakthroughs in the deployment, integration, security, and operational range of wireless networking can provide new scientific capabilities for the next decade - from autonomous mobile instruments for scientific user facilities to intelligent sensors networks distributed over thousands of kilometers to study environmental processes. To realize this promise, however, we must continue to drive innovations in computing, artificial intelligence (AI), advanced materials, high-speed networking, and microelectronics. In March 2020, the DOE-SC convened a workshop to identify the potential opportunities and explore the scientific challenges of advanced wireless technologies.

42 ENGINEERING↗

The Steel Equivalency Workbook: An X-Ray Transmission Calculator

The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.

36 MATERIALS SCIENCE↗

X-ray CT Scans - Rodents - Set 4

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Camera Calibration Methods for Naturalistic Driving Studies

Naturalistic driving studies typically utilize a variety of sensors, including radar, kinematic sensors, and video cameras. While the main objective of such sensors is typically safety focused, with a goal of recording accidents and near accidents for later review, the instrumentation provides a valuable resource for a variety of transportation research. Some applications, however, require additional processing to improve the utility of the data. In this work, we describe a computer vision procedure for calibrating front view cameras for the Second Strategic Highway Research Project. A longitudinal stability study of the estimated parameters across a small sample set of cameras is presented along with a proposed procedure for calibrating a larger number of cameras from the study. A simple use case is presented as one example of the utility of this work. Finally, we discuss plans for calibrating the complete set of approximately 3000 cameras from this study.

Paone, Jeffrey R.↗

Model-Independent Characterization of Charge Diffusion in Thick Fully Depleted CCDs

We present a new method to measure charge diffusion in charge-coupled devices (CCDs). The method is based on a statistical characterization of the shapes of charge clouds produced by low-energy X-rays using known properties of the two-dimensional Gaussian point-spread function (PSF). The algorithm produces reliable upper and lower bounds on the size of the PSF for photons converting near the entrance window of a device. It is optimally suited to the case of thick back-illuminated CCDs where the X-ray absorption length is smaller than the silicon thickness and the diffusion scale is of the same order as the pixel size. The only assumptions are that the charge cloud width is a monotonically increasing function of distance from the conversion point to the buried channel, and that the conversion probability is peaked at the surface. Otherwise, no physical models of carrier transport or knowledge of the electric field profile in the CCD are needed. In suboptimal conditions, the upper bound increases and the lower bound is unaffected, so confidence in the correctness of results is retained. The new method has been benchmarked against Monte Carlo simulations and tested on X-ray images measured on thick high-resistivity prototype CCDs for the Large Synoptic Survey Telescope. In Monte Carlo simulations of noiseless images having the optimal diffusion scale, the upper bound approximated the true PSF within 5%, increasing to 10% in simulations with added noise. Even with severely undersampled or truncated PSFs, the method brackets the true value to within 25%. Our method is accurate and computationally efficient and offers a fast and simple experimental setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated imaging system for single molecules

There is provided a high throughput automated single molecule image collection and processing system that requires minimal initial user input. The unique features embodied in the present disclosure allow automated collection and initial processing of optical images of single molecules and their assemblies. Correct focus may be automatically maintained while images are collected. Uneven illumination in fluorescence microscopy is accounted for, and an overall robust imaging operation is provided yielding individual images prepared for further processing in external systems. Embodiments described herein are useful in studies of any macromolecules such as DNA, RNA, peptides and proteins. The automated image collection and processing system and method of same may be implemented and deployed over a computer network, and may be ergonomically optimized to facilitate user interaction.

47 OTHER INSTRUMENTATION↗

Measurement of the U-235 Content of Concreted Waste Drums

A challenging assay situation recently arose, whereby the fissile (i.e. total plutonium plus U-235) content of a population of 164 historical waste drums containing concrete needed to be measured, to comply with nuclear safety limits for transport to, and interim storage within, an Engineered Drum Store. BIL Solutions Ltd has developed a new methodology for measurement of the U-235 content of these 'concrete' drums, because the approach normally used by the in-situ Drum Monitors was found to be overly pessimistic. Initial investigations indicated significant quantities of uranium were present in these drums (but negligible plutonium), mixed with Np-237 and / or Ra-226. These initial measurements also indicated that the uranium was likely to be depleted in enrichment. The U-235 content was therefore determined by measuring the U-238 mass via the passive coincident neutron emission, and combining this with the U-235 and U-238 isotopic abundances, obtained by analysis of a gamma spectrum. Of the uranium isotopic analysis codes available, the FRAM (Fixed energy, Response function Analysis with Multiple efficiencies) software was selected as being most suitable for this application. A wide gamma-ray energy range is used (i.e. 120 keV to 1200 keV) which was considered more likely to yield results when there is significant attenuation. The software is also user configurable, enabling interferences from the other radionuclides present (i.e. Np-237 and Ra-226) to be accounted for. A series of test measurements were performed with well-characterised uranium sources attenuated by concrete shielding, to gain confidence in the performance of FRAM under such conditions. These test measurements indicated that FRAM was able to correctly determine the enrichment of heavily shielded uranium. The new U-235 measurement methodology was then applied to the population of concrete drums; successfully yielding U-235 results despite the dense waste matrix and significant interference from Np-237 and / or Ra-226. The U-235 mass results obtained were significantly more accurate than those that would have been obtained had the traditional approach (i.e. transmission corrected 186 keV count rate) been used, facilitating safe transport and storage of the drums. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of TRIGA-based experimental device for fiber optics in-core instrumentation testing for VHTRs

Given the harsh environments of high temperature reactors, new in-core instrumentation has to be developed, since existing approaches may fail prematurely in VHTRs. The paper discusses ongoing efforts to support progress of suitable advanced in-core instrumentation technologies and develop an experimental approach for evaluation of their performance within VHTRs via emulation of VHTR in-core conditions in TRIGA reactors. Successful completion of the presented computational analysis concludes the first phase of the project. As demonstrated, it is proposed to use a high temperature furnace with fluence equivalency in operating TRIGA reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is discussed, along with the measured performance results, calibration methodology and verification, and minimum detectable activity levels. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels. A test box containing plywood (specific gravity 0.5) with holes for reproducible positioning of known point sources has been constructed and used in several configurations. Gamma spectra have been processed multiple times with user-adjustable parameters set to a variety of values to gain agreement on the most appropriate settings. A similar optimization process was followed with the custom software provided by the instrument manufacturer to reach agreement on the most stable settings for reliable results. Measurements made with the Canberra In-Situ Object Counting System (ISOCS) instrument were compared with the WAS results as part of an estimate of instrument precision and accuracy. The validation report will conclude with recommendations for the configuration, appropriate use and limitations of the Waste Assay System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Application of MCNP6.2 Unstructured Mesh Geometry Capabilities to the Study of Heavy Ion Single Event Effect on Microelectronic Devices and the Reactor Physics Analysis - 25691

Unstructured meshes allow irregular or complex geometries to be modeled precisely in Monte Carlo radiation transport codes. Through this capability, it is possible to share an unstructured mesh model between multiple codes that use unstructured mesh geometry and thus improving coupled multi-physics simulations. In this work, unstructured meshes are used to model energy deposition from heavy ion strikes for single event effects on microelectronic devices as well as neutron flux mapping of nuclear reactor configurations. In each case, MCNP6.2's unstructured mesh functionality and applicability to the problem is demonstrated and analyzed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗