Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Science - Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Polychromatic X-ray Micro- and Nanodiffraction for Spatially-Resolved Structural Studies

The availability of intense, focused synchrotron X-ray microbeams has enabled new techniques for materials investigations with sub-micron spatial resolution. The scanning microbeam setup we have developed at the XOR-UNI beamline at the Advanced Photon Source (APS) is versatile in that it provides 1D, 2D or 3D scans (including depth resolution), and can alternate between polychromatic- and monochromatic-beam modes. Focusing in both modes uses elliptical Kirkpatrick-Baez (K-B) reflecting mirrors. Beam diameters of {approx} 500 nm FWHM are now routine, and 90 nm focus has been demonstrated. In white-beam mode, a CCD detector records a complete Laue diffraction pattern, which is analyzed with an automated indexing program. These X-ray diffraction patterns provide real-space maps of the local lattice structure, crystal orientation, grain morphology, and strain tensor. Spatially-resolved X-ray microdiffraction studies are now providing previously unavailable measurements of local microstructures. These measurements, in turn, yield new insights in several classic fields of materials science. This paper will illustrate the application of polychromatic scanning X-ray microscopy with examples from 1D, 2D and 3D materials systems. In 1D systems, we have mapped the structure and orientation of an individual ZnO nanorod along with the associated Ge catalyst particle used to control the nanocrystal growth. In 2D systems, X-ray microdiffraction studies have revealed the mechanisms for local crystallographic tilting in epitaxial oxide films grown on textured Ni substrates for superconducting applications. In 3D systems, X-ray microscopy investigations have included in-situ studies of microstructural evolution during thermal grain growth in polycrystalline aluminum. In general, these spatially-resolved measurements provide important new insights and are valuable as input for theoretical and computer modeling studies of a wide range of material processes.

43 PARTICLE ACCELERATORS↗

A Co-design Framework for Online Data Analysis and Reduction

Science applications preparing for the exascale era are increasingly exploring in situ computations comprising of simulation-analysis-reduction pipelines coupled in-memory. Efficient composition and execution of such complex pipelines for a target platform is a codesign process that evaluates the impact and tradeoffs of various application- and system-specific parameters. In this article, we describe a toolset for automating performance studies of composed HPC applications that perform online data reduction and analysis. We describe Cheetah, a new framework for composing parametric studies on coupled applications, and Savanna, a runtime engine for orchestrating and executing campaigns of codesign experiments. Furthermore, this toolset facilitates understanding the impact of various factors such as process placement, synchronicity of algorithms, and storage versus compute requirements for online analysis of large data. Ultimately, we aim to create a catalog of performance results that can help scientists understand tradeoffs when designing next-generation simulations that make use of online processing techniques. We illustrate the design of Cheetah and Savanna, and present application examples that use this framework to conduct codesign studies on small clusters as well as leadership class supercomputers.

97 MATHEMATICS AND COMPUTING↗

Buried Hydrogen Bond Interactions Contribute to the High Potency of Complement Factor D Inhibitors

Aberrant activation of the complement system is associated with diseases, including paroxysmal nocturnal hemoglobinuria and age-related macular degeneration. Complement factor D is the rate-limiting enzyme for activating the alternative pathway in the complement system. Recent development led to a class of potent amide containing pyrrolidine derived factor D inhibitors. Here, we used biochemical enzymatic and biolayer interferometry assays to demonstrate that the amide group improves the inhibitor potency by more than 80-fold. Our crystal structures revealed buried hydrogen bond interactions are important. Molecular orbital analysis from quantum chemistry calculations dissects the chemical groups participating in these interactions. Free energy calculation supports the differential contributions of the amide group to the binding affinities of these inhibitors. Cell-based hemolysis assay confirmed these compounds inhibit factor D mediated complement activation via the alternative pathway. Our study highlights the important interactions contributing to the high potency of factor D inhibitors reported recently.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diamagnetic flux measurement in Aditya tokamak

Measurements of diamagnetic flux in Aditya tokamak for different discharge conditions are reported for the first time. The measured diamagnetic flux in a typical discharge is less than 0.6 mWb and therefore it has required careful compensation for various kinds of pick-ups. The hardware and software compensations employed in this measurement are described. We introduce compensation of a pick-up due to plasma current of less than 20 kA in short duration discharges, in which plasma pressure gradient is supposed to be negligible. The flux measurement during radio frequency heating is also presented in order to validate compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CyberGIS software: a synthetic review and integration roadmap

CyberGIS defined as cyberinfrastructure-based geographic information systems (GIS) has emerged as a new generation of GIS representing an important research direction for both cyberinfrastructure and geographic information science. This study introduces a 5-year effort funded by the US National Science Foundation to advance the science and applications of CyberGIS, particularly for enabling the analysis of big spatial data, computationally intensive spatial analysis and modeling (SAM), and collaborative geospatial problem-solving and decision-making, simultaneously conducted by a large number of users. Several fundamental research questions are raised and addressed while a set of CyberGIS challenges and opportunities are identified from scientific perspectives. The study reviews several key CyberGIS software tools that are used to elucidate a vision and roadmap for CyberGIS software research. The roadmap focuses on software integration and synthesis of cyberinfrastructure, GIS, and SAM by defining several key integration dimensions and strategies. CyberGIS, based on this holistic integration roadmap, exhibits the following key characteristics: high-performance and scalable, open and distributed, collaborative, service-oriented, user-centric, and community-driven. As a major result of the roadmap, two key CyberGIS modalities gateway and toolkit combined with a community-driven and participatory approach have laid a solid foundation to achieve scientific breakthroughs across many geospatial communities that would be otherwise impossible.

CyberGIS↗

Intensity modulated neutron radiotherapy optimization by photon proxy

Purpose: Introducing intensity modulation into neutron radiotherapy (IMNRT) planning has the potential to mitigate some normal tissue complications seen in past neutron trials. While the hardware to deliver IMNRT plans has been in use for several years, until recently the IMNRT planning process has been cumbersome and of lower fidelity than conventional photon plans. Our in-house planning system used to calculate neutron therapy plans allows beam weight optimization of forward planned segments, but does not provide inverse optimization capabilities. Commercial treatment planning systems provide inverse optimization capabilities, but currently cannot model our neutron beam. Methods: We have developed a methodology and software suite to make use of the robust optimization in our commercial planning system while still using our in-house planning system to calculate final neutron dose distributions. Optimized multileaf collimator (MLC) leaf positions for segments designed in the commercial system using a 4 MV photon proxy beam are translated into static neutron ports that can be represented within our in-house treatment planning system. The true neutron dose distribution is calculated in the in-house system and then exported back through the MATLAB software into the commercial treatment planning system for evaluation. Results: The planning process produces optimized IMNRT plans that reduce dose to normal tissue structures as compared to 3D conformal plans using static MLC apertures. The process involves standard planning techniques using a commercially available treatment planning system, and is not significantly more complex than conventional IMRT planning. Using a photon proxy in a commercial optimization algorithm produces IMNRT plans that are more conformal than those previously designed at our center and take much less time to create. Conclusions: The planning process presented here allows for the optimization of IMNRT plans by a commercial treatment planning optimization algorithm, potentially allowing IMNRT to achieve similar conformality in treatment as photon IMRT. The only remaining requirements for the delivery of very highly modulated neutron treatments are incremental improvements upon already implemented hardware systems that should be readily achievable.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of the lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.

60 APPLIED LIFE SCIENCES↗

TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

A phantom design for assessment of detectability in PET imaging

Purpose: The primary clinical role of positron emission tomography (PET) imaging is the detection of anomalous regions of {sup 18}F-FDG uptake, which are often indicative of malignant lesions. The goal of this work was to create a task-configurable fillable phantom for realistic measurements of detectability in PET imaging. Design goals included simplicity, adjustable feature size, realistic size and contrast levels, and inclusion of a lumpy (i.e., heterogeneous) background. Methods: The detection targets were hollow 3D-printed dodecahedral nylon features. The exostructure sphere-like features created voids in a background of small, solid non-porous plastic (acrylic) spheres inside a fillable tank. The features filled at full concentration while the background concentration was reduced due to filling only between the solid spheres. Results: Multiple iterations of feature size and phantom construction were used to determine a configuration at the limit of detectability for a PET/CT system. A full-scale design used a 20 cm uniform cylinder (head-size) filled with a fixed pattern of features at a contrast of approximately 3:1. Known signal-present and signal-absent PET sub-images were extracted from multiple scans of the same phantom and with detectability in a challenging (i.e., useful) range. These images enabled calculation and comparison of the quantitative observer detectability metrics between scanner designs and image reconstruction methods. The phantom design has several advantages including filling simplicity, wall-less contrast features, the control of the detectability range via feature size, and a clinically realistic lumpy background. Conclusions: This phantom provides a practical method for testing and comparison of lesion detectability as a function of imaging system, acquisition parameters, and image reconstruction methods and parameters.

60 APPLIED LIFE SCIENCES↗

Deep Recurrent Neural Networks for seizure detection and early seizure detection systems

Epilepsy is common neurological diseases, affecting about 0.6-0.8 % of world population. Epileptic patients suffer from chronic unprovoked seizures, which can result in broad spectrum of debilitating medical and social consequences. Since seizures, in general, occur infrequently and are unpredictable, automated seizure detection systems are recommended to screen for seizures during long-term electroencephalogram (EEG) recordings. In addition, systems for early seizure detection can lead to the development of new types of intervention systems that are designed to control or shorten the duration of seizure events. In this article, we investigate the utility of recurrent neural networks (RNNs) in designing seizure detection and early seizure detection systems. We propose a deep learning framework via the use of Gated Recurrent Unit (GRU) RNNs for seizure detection. We use publicly available data in order to evaluate our method and demonstrate very promising evaluation results with overall accuracy close to 100 %. We also systematically investigate the application of our method for early seizure warning systems. Our method can detect about 98% of seizure events within the first 5 seconds of the overall epileptic seizure duration.

59 BASIC BIOLOGICAL SCIENCES↗

Arms Control Opportunities for Inherently Safe and Secure Nuclear Command, Control, and Communications

The Department of Defense Science Board has stated that the United States is "not prepared to defend againsr cyber-attacks and that the military could lose "trust in the information and ability to control U.S. systems and forces [including nuclear forces]." One potential weak spot in cyber-security is storing encryption keys in computer memory. This paper explores the use of hardware devices (so-called Physical Unclonable Functions, or PUFs) to generate, in the nuclear weapon itself, unique encryption keys each time they are needed. Not only do we find that this has the potential to mitigate a number of cyberthreats, but such hardware has the potential to greatly diminish the total uncertainty associated with radiation-based warhead authentication procedures; a procedure many analysts feel will be key to future arms control regimes. After outline the use of PUFs in nuclear command, control, and communications--and indicating some of the areas that still require further research--we discuss their application to arms control and warhead authentication

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling andfuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and abattery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC loadestimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Histone Deacetylase Inhibitor MS-275 Exhibits Poor Brain Penetration: Pharmacokinetic Studies of [11C]MS-275 using Positron Emission Tomography

MS-275 (entinostat) is a histone deacetylase (HDAC) inhibitor currently in clinical trials for the treatment of several types of cancer. Recent reports have noted that MS-275 can cross the blood-brain barrier (BBB) and cause region-specific changes in rodent brain histone acetylation. To characterize the pharmacokinetics and distribution of MS-275 in the brain using positron emission tomography (PET), we labeled the carbamate carbon of MS-275 with carbon-11. Using PET, we determined that [{sup 11}C]MS-275 has low uptake in brain tissue when administered intravenously to nonhuman primates. In rodent studies, we observed that pharmacokinetics and brain accumulation of [{sup 11}C]MS-275 were not changed by the coadministration of large doses of unlabeled MS-275. These results, which both highlight the poor brain penetration of MS-275, clearly suggest its limitation as a therapeutic agent for the central nervous system (CNS). Moreover, our study demonstrates the effectiveness of PET at providing brain pharmacokinetic data for HDAC inhibitors. These data are important not only for the development of new compounds for peripheral cancer treatment (where CNS exclusion is often advantageous) but also for the treatment of neurological disorders (where CNS penetration is critical).

59 BASIC BIOLOGICAL SCIENCES↗

Accelerating x-ray tracing for exascale systems using Kokkos

The upcoming exascale computing systems Frontier and Aurora will draw much of their computing power from GPU accelerators. The hardware for these systems will be provided by AMD and Intel, respectively, each supporting their own GPU programming model. The challenge for applications that harness one of these exascale systems will be to avoid lock-in and to preserve performance portability. We report here on our results of using Kokkos to accelerate a real-world application on NERSC's Perlmutter Phase 1 (using NVIDIA A100 accelerators) and Crusher, the testbed system for OLCF's Frontier (using AMD MI250X). By porting to Kokkos, we successfully ran the same X-ray tracing code on both systems and achieved speed-ups between 13 % and 66 % compared to the original CUDA code. Finally, these results are a highly encouraging demonstration of using Kokkos to accelerate production science code.

97 MATHEMATICS AND COMPUTING↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗