Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Integrating Electric Vehicle Charging Infrastructure into Commercial Buildings and Mixed-Use Communities: Design, Modeling, and Control Optimization Opportunities: Preprint

This paper discusses modeling and field studies of controlled EV charging that have been performed with the goal of minimizing requirements for infrastructure upgrades, minimizing building peak demand charges, and maximizing the use of on-site generation. We present a large-scale workplace charging pilot of a demand-controlled scheduled EV charging system with over 250 active daily commuters, successfully demonstrating management of aggregate charging power to avoid new infrastructure investments, mitigate peak demand charges, and provide cost-effective workplace charging to users. In addition to understanding opportunities for demand management, integrating these controllable loads into the energy modeling process for new buildings will also be necessary. This paper then presents an example energy modeling process that evaluates the potential effects of EV charging on building load profiles and infrastructure requirements for a mixed-use community. Finally, we discuss an illustration of how EV charging can be controlled to be synergistic with other building loads and distributed generation.

buildings↗

Reducing Commercial Building Process Loads and Refrigeration Unit Energy Consumption

This resource provides guidance on larger PPLs, many of which are hardwired. Examples include elevators, enterprise servers, freezers, and water fountains with chillers, which are often collectively referred to as "process loads." This resource also outlines how to assess process loads in a building, describes the procedure for identifying which loads to target for reduction, and provides an overview of reduction strategies. In this resource, process loads are broken into five categories - food handling, refrigeration, internal mobility, data center and information technology, and water handling.

commercial buildings↗

A Study of Model-Based Protective Fast-Charging and Associated Degradation in Commercial Smartphone Cells: Insights on Cathode Degradation as a Result of Lithium Depositions on the Anode

The ever expanding mobile consumer electronic market has accelerated the need for safe and efficient fast-charging approaches that improve the overall speed of battery charging without hastened deterioration of the battery performance. Herein, the impact of a resource inexpensive, physics-based, electrochemically optimized fast-charging algorithm (charging time < 2 h) for mobile devices is investigated. A critical difference in the amount and morphology of lithium deposits on the anode for cells fast-charged without an optimized algorithm is observed and found to be the main cause of capacity decay. Furthermore, an in-depth study of the LiCoO 2 cathode regions opposite to pronounced lithium deposits on the anode reveals a “mirroring” phenomenon, i.e., a frozen monoclinic phase, and inactivity to relithiation. In operando hard X-ray absorption spectroscopy reveals that degraded spots on harvested cathodes seem to be activated again and participate in the intercalation process when lithiated at low rates from lithium foil counter electrodes. On the other hand, tests at higher C-rates, closer to the actual fast-charging rate, reveal only negligible oxidation state changes and therefore poor performance.

25 ENERGY STORAGE↗

Effect of Commercial Gas Diffusion Layers on Catalyst Durability of Polymer Electrolyte Fuel Cells in Varied Cathode Gas Environment

Gas diffusion layers (GDLs) play a crucial role in heat transfer and water management of cathode catalyst layers in polymer electrolyte fuel cells (PEFCs). Thermal and water gradients can accelerate electrocatalyst degradation and therefore the selection of GDLs can have a major influence on PEFC durability. Currently, the role of GDLs in electrocatalyst degradation is poorly studied. Here, we perform electrocatalyst accelerated stress test studies on membrane electrode assemblies (MEAs) prepared using three most commonly used GDLs. The effect of GDLs on electrocatalyst degradation is evaluated in both nitrogen (non-reactive) and air (reactive) gas environments at 100% relative humidity. In situ electrochemical characterization and extensive physical characterization is performed to understand the subtle differences in electrocatalyst degradation and correlated to the use of different GDLs. Overall, no difference is observed in the electrocatalyst degradation due to GDLs based on polarization curves at the end of life. But interestingly, MEA with a cracked microporous layer (MPL) in the GDL exhibited a higher electrocatalyst loading loss, which resulted in a lower and more heterogeneous increase in the average electrocatalyst nanoparticle size.

25 ENERGY STORAGE↗

Physicochemical and Performance Characterization of Six Commercial Organic Solvent Nanofiltration Membranes

This work introduces a novel, gradient-free metamaterial design method based on Gaussian process regression to represent the density field of a unit cell. The dimension of the design space is determined by the covariance matrix dimension in the Gaussian process regression. We propose compressing this matrix using an autoencoder, enabling the decoder to generate the density field and effectively reduce the originally large design space to a lower-dimensional subspace. In this compressed space, we employ an active learning method, Bayesian Adaptive Direct Search (BADS), for efficient exploration of the design space. We demonstrate that for simple 2D designs aimed at maximizing unit cell stiffness, our method yields results comparable to those of standard topology optimization. Furthermore, we extend our approach to various mechanical problems, from linear elasticity to hyperelastic large deformation and elasto-plasticity under finite deformation, to 3D metamaterial design. This illustrates the method’s versatility and effectiveness across a range of applications.

Wu, Haoran↗

Analysis of the Financial Impacts of Building Performance Standard Penalties on Commercial Buildings in Aurora, Colorado

Buildings are responsible for 30% of total energy consumption worldwide. To address building energy, jurisdictions in the USA have enacted Building Performance Standards (BPS) legislation. The objective of BPS is to reduce energy consumption in buildings, thereby reducing the energy burden on utility infrastructure and other externalities. This is accomplished by setting mandatory energy use limits coupled with penalties for exceeding those limits. One of the key questions in BPS policymaking is how these penalties might impact the finances of building owners and tenants. This paper presents an analysis of BPS penalties in Aurora, Colorado, specifically targeting buildings impacted by the adopted statewide BPS legislation. Several BPS penalty structures were applied to the affected building stock in Aurora, and the potential impacts on building owner returns and tenant rents were estimated. The results show that for some combinations of building types and penalty structures, potential rent increases due to penalties could match or exceed typical yearly rent increases. The results also show that in most cases, for Aurora, there was no statistically significant difference in impact between buildings located in under-resourced and well-resourced areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement and Modeling of the effects of exhaust composition and hydrothermal aging on the ammonia storage capacity of a commercial Cu-SSZ-13 catalyst

Copper exchanged chabazites are among the state-of-the-art catalyst materials being studied for selective catalytic reduction of NOx, however, there is still a need to understand how these materials store ammonia after aging. In this work, studies are performed to assess the ammonia storage capacity of Cu-SSZ-13 as a function of concentration, temperature, and extent of hydrothermal aging. Ammonia binds at three difference sites: (i) a Cu site bound at 1 framework Al (Z 1 Cu site), (ii) a Cu site bound at 2 framework Al (Z 2 Cu site), and (iii) a Brønsted acid site (ZH site). Results show that a 3-site model can accurately capture ammonia storage across all conditions. Impacts for hydrothermal aging are considered via 3 aging reactions that change the site densities of each identified adsorption site. Model assessment shows that during aging there is a significant loss in Brønsted acid sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗