Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

CFD simulations of electric motor end ring cooling for improved thermal management

Proper thermal management of an electric motor for vehicle applications extends its operating range. One cooling approach is to impinge Automatic Transmission Fluid (ATF) onto the rotor end ring. Increased ATF coverage correlates to enhanced heat transfer. Computational Fluid Dynamics (CFD) analytical tools provide a mechanism to assess motor thermal management prior to hardware fabrication. The complexity of the fluid flow (e.g., jet atomization, interface tracking, wall impingement) and heat transfer makes these simulations challenging. Computational costs are high when solving these flows on high-speed rotating meshes. Typically, a Volume-of Fluid (VOF) technique (i.e., two-fluid system) is used to resolve ATF dynamics within this rotating framework. Suitable numerical resolution of the relevant physics for thin films under strong inertial forces at high rotor speeds is computationally expensive, further increasing the run times. In this work, a numerical study of rotor-ring cooling by ATF is presented using a patent automated Cartesian cut-cell based method coupled with Automatic Mesh Refinement (AMR). This approach automatically creates the Cartesian mesh on-the-fly and can effectively handle complex rotating geometries by adaptively refining the mesh based on local gradients in the flow field which results in better resolution of the air-ATF interface. A Single non-inertial Reference Frame (SRF) approach is used to account for the rotating geometry and to further improve the overall computational efficiency. Quasi-steady state conditions are targeted in the analysis of the results. Important physics such as ATF jet structure, velocity detail near the air-jet interface, ATF coverage/accumulation on the ring surface, and cooling capacity are presented for a low-resolution Reynolds averaged Navier-Stokes (RANS), high-resolution RANS, and high-resolution Large-Eddy Simulation (LES) models. Computations are scaled over hundreds of cores on a supercomputer to maximize turnaround time. Each numerical approach is shown to capture the general trajectory of the oil jet prior to surface impingement. The high-resolution LES simulation, however, is superior in capturing small scale details and heat transfer between the free jet and surrounding air.

42 ENGINEERING↗

Impact of Boron-Containing Lubricant Additive on Three-Way Catalyst Reactivity and Physicochemical Properties

Boron-containing compounds are one of the lubricant additive options due to their suitable properties for additives and have been used as commercial lubricant additives. In the present study, the impact of a boron-containing lubricant oil additive, AR9100 (BR), on Pd/Rh-based three-way catalyst (TWC) performance is investigated, and the results are compared with the baseline no-additive (NA) case and the industry standard zinc dialkyl-dithiophosphate (ZDDP) results. Accelerated engine aging is performed using a genset to expose the catalysts to lubricant additives at high temperatures. All aged TWC samples are investigated for reactivity in a bench-flow reactor and characterized using a variety of analytical techniques. Compared with the no-additive case, the temperatures of 90% conversion (T 90 ) of NO, CO, C 3 H 6 , and C 3 H 8 for the ZDDP-aged TWC sample increased by 34, 30, 37, and 48 °C. However, the T 90 of all gas species for the BR-aged TWC sample are similar to the NA-aged TWC sample. Additionally, a significant decrease in water–gas shift reactivity and oxygen storage capacity is observed in the ZDDP-aged sample, but not in the BR-aged sample. Inductively coupled plasma-optical emission spectrometry (ICP-OES) analysis and electron probe microanalysis (EPMA) maps of accelerated engine aging samples show the presence of phosphorus and boron in ZDDP- and BR-aged TWC samples, respectively. However, no boron-related peaks are observed in the X-ray diffraction (XRD) pattern of the BR-aged TWC sample, which may exist in the form of an amorphous phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Framework for an Open-Source Life Cycle Baseline for Electricity Consumption in the United States - LCAXVII

This work was presented at the American Center for Life Cycle Assessment (ACLCA) LCAXVII Conference in Portsmouth, NH on October 4, 2017. NETL has developed an open source multifunctional life cycle model to quantify baseline life cycle impacts of U.S. electricity consumption. The life cycle framework is under development in OpenLCA, an open source professional LCA software. The multifunctional framework supports analysis at multiple spatiotemporal timescales as well as modularity to incorporate new datasets. Moreover, the analytic framework provides a complete environmental inventory for U.S. electricity, with the capacity to inform multiple impact assessment methods and to quantify several environmental metrics including air emissions, water use, and energy-consumption indicators.

Ingwerson, Wesley W↗

Supply Chain for Energy Technologies

Understanding manufacturing cost implications of technologies is critical to aid adoption of next-generation energy solutions. It is important to understand not only of the manufacturing costs and value-add along the supply chain, but also gain understanding of manufacturing location decisions. By identifying a technology's competitive strengths and weaknesses, analyses give researchers and program decision makers the data and insights needed to create strategies and plans that better promote U.S. economic growth and pursue R&D activities that have the greatest long-term potential to yield significant energy savings for U.S. consumers. In this talk, we present examples of analysis from a variety of energy technologies to demonstrate how manufacturing cost analysis can be used to answer specific policy or research questions. In addition, we present case studies showing the importance of understanding trade flow, manufacturing locations, and capacity and utilization to inform economic growth and potential for technology adoption.

benchmarking↗

Effect of hydrogen sulfide on chemical looping combustion of coal-derived synthesis gas over bentonite-supported metal-oxide oxygen carriers

The effect of hydrogen sulfide (H{sub 2}S) on the chemical looping combustion of coal-derived synthesis gas with bentonite-supported metal oxides - such as iron oxide, nickel oxide, manganese oxide, and copper oxide - was investigated by thermogravimetric analysis, mass spectrometry, and X-ray photoelectron spectroscopy (XPS). During the reaction with synthesis gas containing H{sub 2}S, metal-oxide oxygen carriers were first reduced by carbon monoxide and hydrogen, and then interacted with H{sub 2}S to form metal sulfide, which resulted in a weight gain during the reduction/sulfidation step. The reduced/sulfurized compounds could be regenerated to form sulfur dioxide and oxides during the oxidation reaction with air. The reduction/oxidation capacities of iron oxide and nickel oxide were not affected by the presence of H{sub 2}S, but both manganese oxide and copper oxide showed decreased reduction/oxidation capacities. However, the rates of reduction and oxidation decreased in the presence of H{sub 2}S for all four metal oxides.

01 COAL, LIGNITE, AND PEAT↗

2016 Standard Scenarios Report: A U.S. Electricity Sector Outlook

The Standard Scenarios and this associated report, which are now in their second year, present an examination of some of the key aspects of the change occurring, or anticipated to occur, in the power sector over the next several decades. The Standard Scenarios consist of 18 power sector scenarios which have been projected using the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) long-term capacity expansion model and the dGen rooftop PV diffusion model. The purpose of the Standard Scenarios and this associated report is to provide context, discussion, and data to inform stakeholder decision-making regarding the future direction of U.S. power sector. As an extension to this report, the Standard Scenario outputs are presented in a downloadable format online using the Standard Scenarios' Results Viewer at http://en.openei.org/apps/reeds/. This report reflects high-level conclusions and analysis, whereas the Standard Scenarios' Results Viewer includes the scenario results that can be used for more in-depth analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Land-Use Requirements for Solar Power Plants in the United States

This report provides data and analysis of the land use associated with utility-scale ground-mounted solar facilities, defined as installations greater than 1 MW. We begin by discussing standard land-use metrics as established in the life-cycle assessment literature and then discuss their applicability to solar power plants. We present total and direct land-use results for various solar technologies and system configurations, on both a capacity and an electricity-generation basis. The total area corresponds to all land enclosed by the site boundary. The direct area comprises land directly occupied by solar arrays, access roads, substations, service buildings, and other infrastructure. As of the third quarter of 2012, the solar projects we analyze represent 72% of installed and under-construction utility-scale PV and CSP capacity in the United States.

14 SOLAR ENERGY↗

Data for "Adsorptive Separation and Recovery of Triacetic Acid Lactone from Fermentation Broth"

Triacetic acid lactone (TAL) can be microbially produced and further chemically upgraded to several high-value chemicals. In this work, several acidic and basic ion-exchange resins and activated charcoal were evaluated for their ability to adsorb microbially produced TAL. Activated charcoal and a weak base resin, Dowex 66, showed similar TAL adsorption capacity of 0.18 ± 0.002 g/g. At 15% w/v activated charcoal, about 98% of TAL present in fermentation broth could be adsorbed. Further, ethanol washing allowed recovery of 72% of adsorbed TAL. A biorefinery producing TAL from sucrose was designed, simulated, and evaluated (through technoeconomic analysis) under uncertainty, for an estimated TAL minimum product selling price (MPSP) of $4.27/kg [$3.71−4.94/kg; 5th-95th percentiles] for the current state of technology and $2.83/kg [$2.46–3.29/kg] following potential near-term improvements to fermentation. Thus, this work provides an adsorptive process to recover microbially produced TAL that can be chemically upgraded to several industrial products.

Bioproducts↗

A compositional gradient Ce1−xZrxO2 buffer architecture for producing high-performance YBCO film

Highlights: • The compositional gradient CZO buffer architecture can help improve the biaxial texture of YBCO film. • The high density stacking faults are directly observed via a spherical aberration corrected transmission electron microscope. • The enhanced flux pinning force and current-carrying capacity of YBCO films are achieved as a result of lattice strains. - Abstract: In this work, YBCO films were epitaxially grown on Ce{sub 1−x}Zr{sub x}O{sub 2} (CZO) buffered yttria stabilized zirconia (YSZ) single crystal substrates through a fluorine-free sol-gel process. The influence of two different CZO buffer architectures on the microstructure and superconducting properties of YBCO films was investigated. According to XRD results in combination with (S)TEM analysis, it was confirmed that YBCO film grown on the gradient CZO buffer layer (CZO-G) exhibits better in-plane and out-of-plane texture than YBCO film deposited on the uniform CZO buffer layer (CZO-20). And besides, the superconducting performances especially the current-carrying capacity under magnetic field of the former was much higher than that of the latter, which means that the enhanced flux pinning force will be presented in YBCO film on CZO-G buffer layer. The maximum pinning force of the YBCO film grown on CZO-G buffer architecture is up to 17.67 GN/m{sup 3} @ 65 K. HR-STEM analysis shows that the stacking faults within YBCO matrix gave rise to the considerable nanoscale lattice-strains which may suppress the formation of Copper pairs and produce nanoscale non-superconducting regions served as pinning centers to significantly improve the flux pinning performance of YBCO film. Given the above, it has been implied that high-performance YBCO coated conductor can be developed by using a compositional gradient Ce{sub 1−x}Zr{sub x}O{sub 2} films as buffer architecture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Innovative Pathways to Net Zero Emissions: Subnational Strategies for Distributed Solar Deployment to Improve Grid Quality and Reduce Energy Costs in Argentina

Through Net Zero World, the National Renewable Energy Laboratory (NREL), the National Energy Secretariat of Argentina, La Pampa's Energy and Mining Secretariat, Pampetrol, and the Administracion Provincial de Energia de La Pampa (APELP) conducted an integrated analysis of the power system of the La Pampa province in Argentina. The study assessed the impact that solar and battery energy storage systems could have on the region grid's reliability and electricity costs, providing insights into long-term decarbonization strategies across Argentina. The analysis demonstrated that these systems are expected not only to help with decarbonization efforts but also to bolster grid resiliency, reduce line losses, and improve voltage regulation while lowering electricity costs. The paper offers a replicable framework for similar studies across other Argentine provinces, which could inform a national grid reliability plan and promote regional coordination. Such coordination will play a key role in supporting a nationwide clean energy transition as Argentina increases its share of renewable energy. By coordinating subnational energy plans with national strategies, Argentina can secure a resilient clean energy future, leveraging the substantial renewable resources available across its provinces.

14 SOLAR ENERGY↗

Structure evolution and thermal stability of high-energy density Li-ion battery cathode Li 2 VO 2 F

Lithium-ion batteries (LIBs) provide high-energy-density electrochemical energy storage, which plays a central role in advancing technologies ranging from portable electronics to electric vehicles (EVs). However, a demand for lighter, more compact devices and for extended range EVs continues to fuel the need for higher energy density storage systems. Li 2 VO 2 F, which is synthesized in its lithiated state, allows two-electron transfer per formula during the electrochemical reaction providing a high theoretical capacity of 462 mAh/g. Herein, the synthesis and electrochemical performance of Li 2 VO 2 F are optimized. The thermal stability of Li 2 VO 2 F, which is related to the safety of a battery is studied by thermal gravimetric analysis. The structure and vanadium oxidation state evolution along Li cycling are studied by ex-situ X-ray diffraction and absorption techniques. It is shown that the rock-salt structure of pristine Li 2 VO 2 F is stable up to at least 250°C, and is preserved upon Li cycling, which proceeds by the solid-solution mechanism. However, not all Li can be removed from the structure upon charge to 4.5 V, limiting the experimentally obtained capacity.

25 ENERGY STORAGE↗

Analysis on the Influence of an Energy Storage System and Its Impact to the Grid for a Wave Energy Converter: Preprint

This paper presents an analysis on the cost of and how a battery storage system can be used to further reduce the variation of power generated from the wave energy converter (WEC) due to the fluctuating nature of waves and its impact to the grid. The electrical power output from WEC-Sim simulations for the six sea states used in the Wave Energy Prize was analyzed to compute the peak power and power time history. The results were used to evaluate the battery storage capacity that is needed for a WEC system to provide reasonable power flow to the grid and estimate its cost based on the latest cost information for battery technologies published by the U.S. Energy Information Administration. Finally, a preliminary grid integration analysis was performed to demonstrate how WEC-generated power would contribute to a small island electricity system. As shown in the study, the instantaneous peak power is the primary cost driver for the battery storage and the power take-off system, and reducing the power fluctuations is essential for reducing the overall levelized cost of energy (LCOE). The power flow variation from WECs can be significantly reduced using battery storage without adding significant overall system costs, and the implementation of battery storage is essential for grid integration applications. There may also be additional opportunities to further investigate energy storage technologies that are specific to WEC applications to reduce these costs even further.

16 TIDAL AND WAVE POWER↗

Iron oxide hydroxide nanoflower assisted removal of arsenic from water

Graphical abstract: Non-magnetic polycrystalline iron oxide hydroxide nanoparticle with flower like morphology is found to play as an effective adsorbent media to remove As(III) from 300 μg L{sup −1} to less than 10 μg L{sup −1} from drinking water over wide range of pH. TEM image clearly reveals that the nanoparticle looks flower like morphology with average particle size less than 20 nm. The maximum sorption capacity of the sorbent is found to be 475 μg g{sup −1} for arsenic at room temperature and the data fitted to different isotherm models indicate the heterogeneity of the adsorbent surface. The material can be regenerated up to 70% using dilute hydrochloric acid and it would be utilized for de-arsenification purposes. - Highlights: • The work includes synthesis of iron oxide hydroxide nanoflower and its applicability for the removal of arsenic from water. • The nanoparticle was characterized using modern instrumental methods like FESEM, TEM, BET, XRD, etc. • The maximum sorption capacity of the sorbent is found to be 475 μg g{sup −1} for arsenic at room temperature. • The sorption is multilayered on the heterogeneous surface of the nano adsorbent. • The mechanism of arsenic removal of IOH nanoflower follows both adsorption and ion-exchange. - Abstract: Non-magnetic polycrystalline iron oxide hydroxide nanoparticle with flower like morphology is found to play as an effective adsorbent media to remove As(III) from 300 μg L{sup −1} to less than 10 μg L{sup −1} from drinking water over wide range of pH. The nanoparticle was characterized by X-ray powder diffraction analysis (XRD), BET surface area, FTIR, FESEM and TEM images. TEM image clearly reveals flower like morphology with average particle size less than 20 nm. The nanoflower morphology is also supported by FESEM images. The maximum sorption capacity of the sorbent is found to be 475 μg g{sup −1} for arsenic and the data fitted to different isotherm models indicate the heterogeneity of the adsorbent surface. Study on adsorption kinetics shows that adsorption of arsenic onto iron oxide hydroxide nanoflower follows pseudo-second order kinetic. The material can be regenerated up to 70% using dilute hydrochloric acid and it would be utilized for de-arsenification purposes.

36 MATERIALS SCIENCE↗

A Finite Difference Analysis of the Effect of Graphene Additions on the Electrical Conductivity of Polycrystalline Copper

A finite-difference method was used to explore the effect of graphene on the bulk electrical conductivity of copper-graphene composites. In this capacity, grain orientation information from pure copper and copper-graphene composites were used to generate synthetic 3D microstructures. The electrical conductivity of these microstructures were calculated using the finite difference method assuming different average grain sizes. From these calculations, we demonstrate that when high-conductivity grain boundaries are present within the microstructure arising from the presence of graphene, an increase in the bulk electrical conductivity is observed. On the other hand, the difference in textures between copper and copper-graphene composites may not account for a significant difference in bulk electrical conductivity. In comparison, the copper grain size has a considerably larger effect on electrical conductivity as previously anticipated. This is one of the first demonstrations of a physical basis for enhanced conductivity composites and presents pathways for further investigations on the effects of composite microstructural features, material interfaces and graphene content on electrical performance.

Frazier, William E.↗

Transient and thermo-economic analysis of MED-MVC desalination system

An exergo-economic model is used to assess the performance of a multi-effect desalination plant integrated to a mechanical vapor compressor unit (MED-MVC) with a water production capacity of 1500 $m^3$/day. The results show that the second law efficiency ($\eta_{II}$) 2.8%. The MVC and evaporator units are responsible for about 39 and 52% of the total exergy destruction, respectively. The total water price (TWP) is 1.70 $\$/m^3$ when calculated using a simple conventional economic model and 1.63 $\$/m^3$ when calculated using an exergy-based cost model. Increasing the number of effects from 1 to 6 results in a 39% reduction in the specific power consumption (SPC), a 70% increase in $\eta_{II}$ and a 24% decrease in TWP. A dynamic model is developed to investigate the effect of fluctuations of compressor work ($\dot{W}_c$) and inlet seawater temperature ($T_{sw}$) on the plant behavior and performance. The dynamic model results show that the disturbance in $\dot{W}$ has a significant effect on the plant transient behavior and may cause the plant to cease operation while a disturbance in $T_{sw}$ has only a moderate impact. Increasing $T_{sw}$ above a certain value of the steady-state condition without proper control on the plant response could lead to evaporator dry out. In term of performance, a reduction in $\dot{W}_c$ causes a decrease in the plant production capacity and SPC, while it increases the plant performance ratio (PR). On the other hand, a reduction in the inlet $T_{sw}$ causes a reduction in the plant production capacity and PR and an increase in SPC for the same compressor work. Furthermore, a comparison between a MED-MVC system and a MED integrated to a thermal vapor compressor system (MED-TVC) reveals that the latter system is rather sensitive to the reduction in $T_{sw}$ due to the presence of the condenser unit in the MED-TVC. The response of the MED-MVC system is slower than the MED-TVC which is due to the high thermal capacity of the preheaters for the feed in the MED-MVC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗

Agulhas Current Properties Shape Microbial Community Diversity and Potential Functionality

Understanding the impact of oceanographic features on marine microbial ecosystems remains a major ecological endeavour. Here we assess microbial diversity, community structure and functional capacity along the Agulhas current system and the Subtropical convergence in the South Indian Ocean (SIO). Samples collected from the epipelagic, oxygen minimum and bathypelagic zones were analysed by 16S rRNA gene amplicon and metagenomic sequencing. In contrast to previous studies, we found high taxonomic richness in surface and deep water samples, but generally low richness for oxygen minimum zone communities. Beta-diversity analysis revealed significant dissimilarity between the three water depths. Most microbial communities were dominated by marine Gammaproteobacteria, with strikingly low levels of picocyanobacteria. Community composition was strongly influenced by specific environmental factors including depth, salinity, and the availability of both oxygen and light. Carbon, nitrogen and sulphur cycling capacity is the SIO was linked to several autotrophic and copiotrophic Alphaproteobacteria and Gammaproteobacteria. Taken together, our data suggest that the environmental conditions in the Agulhas current system, particularly depth-related parameters, substantially influence microbial community structure. While the capacity for biogeochemical cycling of nitrogen and sulphur is linked primarily by the dominant Gammaproteobacterial taxa, ecologically rare taxa drive carbon cycling.

59 BASIC BIOLOGICAL SCIENCES↗

Regional Assessment for the CO 2 Storage Potential in the Northern Niagaran Pinnacle Reef Trend

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the regional analysis of the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Northern Michigan as part of the MRCSP programs Regional Assessment goals. The goal of this task was to perform an initial assessment of the geologic storage capacity and injectivity of the Northern Fairway of Michigan’s Niagaran Reef Trend. This was achieved through three main objectives: 1) development of a reef atlas, 2) understanding the regional trends in geology, and 3) estimating CO 2 and CO 2 -EOR resources. Data collected across multiple subtasks were integrated into a mappable database that could be accessed from many of the leading software. The reef atlas was used to map the reefs and associated characteristics across the entire NNPRT. Several methodologies were explored to estimate the CO 2 and CO 2 -EOR resources across the trend which included three scenarios: 1) storage only using fluid substitution and volumetric estimations, 2) CO 2 -EOR which applied proximity analysis concepts and measured performance metrics from the Core Energy reefs to predict performance at all oil reefs, and 3) enhanced storage scenario which combined CO 2 -EOR with fluid substitution to represent maximized storage after completion of CO 2 -EOR.

01 COAL, LIGNITE, AND PEAT↗