SEARCH · Engineering Papers
Results for “COMPACTING”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The strand exchange domain of tumor suppressor PALB2 is intrinsically disordered and promotes oligomerization-dependent DNA compaction
Not provided.
The compact gradient recovery discontinuous Galerkin method for diffusion problems
Not Available
On rapid compaction of granular materials: Combining experiments with in-situ imaging and mesoscale modeling
Not provided.
Quantifying 3D time-resolved kinematics and kinetics during rapid granular compaction, Part I: Quasistatic and dynamic deformation regimes
Not Available
Quantifying 3D time-resolved kinematics and kinetics during rapid granular compaction, Part II: Dynamics of heterogeneous pore collapse
Not Available
X-ray computed tomography of deconsolidated TRISO Particles from the AGR-5/6/7 irradiation experiment capsule 1 Compact
Not Available
Eshelby's solution for ellipsoidal inhomogeneous inclusions with applications to compaction bands
Not Available
A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom
In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.
Compact ammonia reforming at low temperature using catalytic membrane reactors
Ammonia is a leading carrier for the storage and transport of renewable hydrogen, but its deployment requires scalable technologies for efficient decomposition and purification. In this work, we report on the efficient delivery of high purity hydrogen from ammonia decomposition using a catalytic membrane reactor (CMR). Improvements to the electroless plating process reduced the Pd membrane thickness by >35%, resulting in commensurate increases in hydrogen permeance without sacrificing selectivity. To increase throughput a commercial Ru/Al 2 O 3 catalyst was added to the lumen, and the CMR could process ammonia flowrates 10–50 times higher than an equivalent packed bed reactor while maintaining the same level of conversion. It is shown that the earth-abundant zeolite clinoptilolite could reduce ammonia impurities in the permeated H 2 to the levels required by PEM fuel cells (<25 ppb). Performance increased significantly across a >500-h durability test due to improvements in membrane permeability. Finally, the results show that CMRs are a viable technology for distributed production of hydrogen from ammonia.
Cross section generation for a conceptual horizontal, compact high temperature gas reactor
Not Available
Development of a compact E ? B microchannel plate detector for beam imaging
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.
Model-based design evaluation of a compact, high-efficiency neutron scatter camera
Not Available