Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOOSTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

Ionization profile monitors for the IOTA proton beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors — one vertical and one horizontal — are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. Furthermore, in this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

Beam diagnostics↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Testing of Cryogenic Photomultiplier Tubes for the MicroBooNE Experiment

The MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a light collection system. Thirty-two 8-inch diameter Hamamatsu R5912-02mod cryogenic photomultiplier tubes (PMTs) will detect the scintillation light generated in the liquid argon (LAr). This article first describes the MicroBooNE PMT performance test procedures, including how the light collectionsystem functions in the detector, and the design of the PMT base. The design of the cryogenic test stand is then discussed, and finally the results of the cryogenic tests are reported.

Briese, T.↗

Declines in Pneumonia and Meningitis Hospitalizations in Children Under 5 Years of Age After Introduction of 10-Valent Pneumococcal Conjugate Vaccine in Zambia, 2010–2016

Background: Pneumococcus is a leading cause of pneumonia and meningitis. Zambia introduced a 10-valent pneumococcal conjugate vaccine (PCV10) in July 2013 using a 3-dose primary series at ages 6, 10, and 14 weeks with no booster. We evaluated the impact of PCV10 on meningitis and pneumonia hospitalizations. Methods: Using hospitalization data from first-level care hospitals, available at the Ministry of Health, and from the largest pediatric referral hospital in Lusaka, we identified children aged <5 years who were hospitalized with pneumonia or meningitis from January 2010–December 2016. We used time-series analyses to measure the effect of PCV10 on monthly case counts by outcome and age group (<1 year, 1–4 years), accounting for seasonality. We defined the pre- and post-PCV10 periods as January 2010–June 2013 and July 2014–December 2016, respectively. Results: At first-level care hospitals, pneumonia and meningitis hospitalizations among children aged <5 years accounted for 108 884 and 1742 admissions in the 42 months pre-PCV10, respectively, and 44 715 and 646 admissions in the 30 months post-PCV10, respectively. Pneumonia hospitalizations declined by 37.8% (95% confidence interval [CI] 21.4–50.3%) and 28.8% (95% CI 17.7–38.7%) among children aged <1 year and 1–4 years, respectively, while meningitis hospitalizations declined by 72.1% (95% CI 63.2–79.0%) and 61.6% (95% CI 50.4–70.8%), respectively, in these age groups. In contrast, at the referral hospital, pneumonia hospitalizations remained stable and a smaller but significant decline in meningitis was observed among children aged 1–4 years (39.3%, 95% CI 16.2–57.5%). Conclusions: PCV10 introduction was associated with declines in meningitis and pneumonia hospitalizations in Zambia, especially in first-level care hospitals.

59 BASIC BIOLOGICAL SCIENCES↗

CABOTO, a high-gradient linac for hadrontherapy

The field of hadrontherapy has grown rapidly in recent years. At present the therapeutic beam is provided by a cyclotron or a synchrotron, but neither cyclotrons nor synchrotrons present the best performances for hadrontherapy. The new generation of accelerators for hadrontherapy should allow fast active energy modulation and have a high repetition rate, so that moving organs can be appropriately treated in a reasonable time. In addition, a reduction of the dimensions and cost of the accelerators for hadrontherapy would make the acquisition and operation of a hadrontherapy facility more affordable, which would translate into great benefits for the potential hadrontherapy patients. The ‘cyclinac’, an accelerator concept that combines a cyclotron with a high-frequency linear accelerator (linac), is a fast-cycling machine specifically conceived to allow for fast active energy modulation. The present paper focuses on CABOTO (CArbon BOoster for Therapy in Oncology), a compact, efficient high-frequency linac that can accelerate C 6+ ions and H 2 molecules from 150– 410 MeV/u in ~24 m. The paper presents the latest design of CABOTO and discusses its performances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Search for Dark Sector 𝑒 + ⁢𝑒 − Explanations of the MiniBooNE Anomaly at MicroBooNE

We present MicroBooNE’s first search for dark sector 𝑒 + ⁢𝑒 − explanations of the long-standing MiniBooNE anomaly. The MiniBooNE anomaly has garnered significant attention over the past 20 years including previous MicroBooNE investigations into both anomalous electron and photon excesses, but its origin still remains unclear. In this Letter, we provide the first direct test of dark sector models in which dark neutrinos, produced through neutrino-induced scattering, decay into missing energy and visible 𝑒 + ⁢𝑒 − pairs comprising the MiniBooNE anomaly. Many such models have recently gained traction as a viable solution to the anomaly while evading past bounds. Using an exposure of 6.87 × 10 20 protons-on-target in the Booster Neutrino Beam, we implement a selection targeting forward-going, coherently produced 𝑒 + ⁢𝑒 − events. After unblinding, we observe 95 events, which we compare with the constrained background-only prediction of 69.7 ±17.3. This analysis sets the world’s first direct limits on these dark sector models and, at the 95% confidence level, excludes the entirety of the single dark neutrino and majority of the dual dark neutrino, parameter space that is viable as a solution to the MiniBooNE anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive Search for Anomalous Single-Photon Production in MicroBooNE

We present an inclusive search for anomalous production of single-photon events from neutrino interactions in the MicroBooNE experiment. The search and its signal definition are motivated by the previous observation of a low-energy excess of electromagnetic shower events from the MiniBooNE experiment. We use the Wire-Cell reconstruction framework to select a sample of inclusive single-photon final-state interactions with a final efficiency and purity of 7.0% and 40.2%, respectively. We leverage simultaneous measurements of sidebands of charged current 𝜈 𝜇 interactions and neutral current interactions producing 𝜋 0 mesons to constrain signal and background predictions and reduce uncertainties. We perform a blind analysis using a dataset collected from February 2016 to July 2018, corresponding to an exposure of 6.34 × 10 20 protons on target from the Booster Neutrino Beam at Fermilab. In the full signal region, we observe agreement between the data and the prediction, with a goodness-of-fit 𝑝 value of 0.11. We then isolate a subsample of these events containing no visible protons, and observe 93 ± 22⁢(stat) ±35⁢(syst) data events above prediction, corresponding to just above 2⁢𝜎 local significance, concentrated at shower energies below 600 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of single- and double-differential cross sections for mesonless charged-current muon neutrino interactions on argon with final-state protons using the MicroBooNE detector

Charged-current neutrino interactions with final states containing zero mesons and at least one proton are of high interest for current and future accelerator-based neutrino oscillation experiments. Using the Booster Neutrino Beam and the MicroBooNE detector at Fermi National Accelerator Laboratory, we have obtained the first double-differential cross-section measurements of this channel for muon neutrino scattering on an argon target with a leading proton momentum threshold of 0.25 GeV/𝑐. We also report a flux-averaged total cross section of 𝜎 = (11.8±1.2) × 10 −38 cm 2 /Ar and several single-differential measurements which extend and improve upon previous results. Statistical and systematic uncertainties are quantified with a full treatment of correlations across 359 kinematic bins, including correlations between distributions describing different observables. The resulting dataset provides the most detailed information obtained to date for testing models of mesonless neutrino-argon scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Charged-Current Muon-Neutrino-Induced 𝐾 + Production on Argon Using the MicroBooNE Detector

The MicroBooNE experiment is an 85 tonne active mass liquid argon time projection chamber neutrino detector exposed to the on-axis Booster Neutrino Beam at Fermilab. One of MicroBooNE’s physics goals is the precise measurement of neutrino interactions on argon in the 1 GeV energy regime. Building on the capabilities of the MicroBooNE detector, this analysis identifies 𝐾 + mesons, a key signature for the study of strange particle production in neutrino interactions. This measurement is furthermore valuable for background estimation for future nucleon decay searches and for improved reconstruction and particle identification capabilities in experiments such as the Deep Underground Neutrino Experiment. In this Letter, we present the first-ever measurement of a flux-integrated cross section for charged-current muon neutrino induced 𝐾 + production on argon nuclei, determined to be 7.93 ± 3.22⁢(stat) ± 2.83⁢(syst)×10 −42 cm 2 /nucleon based on an analysis of 6.88 × 10 20 protons on target. This result was found to be consistent with model predictions from different neutrino event generators within the reported uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First study of neutrino angle reconstruction using quasielasticlike interactions in MicroBooNE

We investigate the expected precision of the reconstructed neutrino direction using a 𝜈 𝜇 -argon quasielasticlike event topology with one muon and one proton in the final state and the reconstruction capabilities of the MicroBooNE liquid argon time projection chamber. This direction is of importance in the context of DUNE sub-GeV atmospheric oscillation studies. MicroBooNE allows for a data-driven quantification of this resolution by investigating the deviation of the reconstructed muon-proton system orientation with respect to the well-known direction of neutrinos originating from the Booster Neutrino Beam with an exposure of 1.3 ×10 21 protons on target. Using simulation studies, we derive the expected sub-GeV DUNE atmospheric-neutrino reconstructed simulated spectrum by developing a reweighting scheme as a function of the true neutrino energy. We further report flux-integrated single- and double-differential cross section measurements of charged-current 𝜈 𝜇 quasielasticlike scattering on argon as a function of the muon-proton system angle using the full MicroBooNE data sets. We also demonstrate the sensitivity of these results to nuclear effects and final state hadronic reinteraction modeling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sampling off-axis neutrino fluxes with the short-baseline near detector

The short-baseline near detector (SBND), the near detector in the short-baseline neutrino program at Fermi National Accelerator Laboratory, is located just 110 m from the booster neutrino beam target. Thanks to this close proximity, relative to its 4 m × 4 m front face, neutrinos enter SBND over a range of angles from 0° to approximately 1.6°, enabling the detector to sample variations in the neutrino flux as a function of the angle—a technique known as precision reaction-independent spectrum measurement (PRISM), referred to here as SBND-PRISM. In this paper, we show how muon- and electron-neutrino fluxes vary as a function of the neutrino beam axis angle and how this can be exploited to expand the physics potential of SBND. We make use of a model that predicts an angle-dependent electron-neutrino excess signal to illustrate this effect, such as 𝜈 𝜇 → 𝜈 𝑒 oscillations. We present how SBND-PRISM provides a method to add robustness against uncertainties in cross-section modeling and, more generally, uncertainties that do not depend on the spatial position of neutrino interaction inside the detector. The fluxes, along with their associated covariance matrices, are made publicly available with this publication.

Abratenko, P. [Tufts University]↗

Analysis of flux-integrated cross sections for quasi-elastic neutrino charged-current scattering off {sup 12}C at energies available at the MiniBooNE experiment

Flux-averaged and flux-integrated cross sections for quasi-elastic neutrino charged-current scattering on nuclei are analyzed. It is shown that the flux-integrated differential cross sections are less dependent on nuclear models than the flux-averaged ones. We calculate these cross sections using the relativistic distorted-wave impulse approximation and relativistic Fermi gas model with the Booster Neutrino Beamline flux and compare the results with the recent MiniBooNE experimental data. Within these models an axial mass M{sub A} is extracted from a fit of the measured d{sigma}/dQ{sup 2} cross section. The extracted value of M{sub A}=1.37{+-}0.05 GeV/c{sup 2} is consistent with the MiniBooNE result. While the measured and calculated double differential cross sections d{sigma}/dTdcos{theta} generally agree, the Fermi gas model predictions are typically lower than data at low muon energies and scattering angles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy neutral leptons decaying into muon-pion pairs in the MicroBooNE detector

We present upper limits on the production of heavy neutral leptons (HNLs) decaying to $\mu \pi$ pairs using data collected with the MicroBooNE liquid-argon time projection chamber (TPC) operating at Fermilab. This search is the first of its kind performed in a liquid-argon TPC. We use data collected in 2017 and 2018 corresponding to an exposure of $2.0 \times 10^{20}$ protons on target from the Fermilab Booster Neutrino Beam, which produces mainly muon neutrinos with an average energy of $\approx 800$ MeV. HNLs with higher mass are expected to have a longer time-of-flight to the liquid-argon TPC than Standard Model neutrinos. The data are therefore recorded with a dedicated trigger configured to detect HNL decays that occur after the neutrino spill reaches the detector. We set upper limits at the $90\%$ confidence level on the element $\lvert U_{\mu4}\rvert^2$ of the extended PMNS mixing matrix in the range $\lvert U_{\mu4}\rvert^2<(6.6$-$0.9)\times 10^{-7}$ for Dirac HNLs and $\lvert U_{\mu4}\rvert^2<(4.7$-$0.7)\times 10^{-7}$ for Majorana HNLs, assuming HNL masses between $260$ and $385$ MeV and $\lvert U_{e 4}\rvert^2 = \lvert U_{\tau 4}\rvert^2 = 0$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗