Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Aluminum Surface Texturing by Means of Laser Interference Metallurgy

The increasing use of lightweight materials, such as aluminum alloys, in auto body structures requires more effective surface cleaning and texturing techniques to improve the quality of the structural components. The present work introduces a novel surface treatment method using laser interferometry produced by two beams of a pulsed Nd:YAG laser operating at 10Hz of frequency to clean aluminum surfaces, and meanwhile creating periodic and rough surface structures. The influences of beam size, laser fluence, wavelength, and pulse number per spot are investigated. High resolution optical profiler images reveal the change of the peak-to-valley height on the laser-treated surface.

Chen, Jian↗

Nonlinear Alfvén instability simulation and EP transport for ITER reversed shear (steady-state) and monotonic q-profile regimes *

The nonlinear evolution and dynamics of energetic particle (EP) driven instabilities in both steady-state (reversed shear q-profile) and monotonic q-profile regimes of ITER are examined using the global gyro-Landau closure model FAR3d. Both neutral beam and alpha components are included, leading to synergistic effects between the two populations. In order to maintain computational feasibility, the present nonlinear simulation includes all toroidal mode numbers ranging from n = 0 to 15. It cannot be excluded that n’s above this range could introduce larger linear growth rates; however, as indicated from the results, the n = 0 to 15 range is sufficient to provide a strong linear drive and significant nonlinear transport effects. While the toroidal mode numbers n = 6,13 dominate the linear instability growth phase, nonlinear energy transfers in the saturated phase reverse this trend, leading to the dominance of lower n’s in the saturated phase of the simulation. Zonal flow structure generation and EP density flattening are further consequences of the nonlinear phase. The density profile flattening is caused by collectively driven EP radial transport fluxes, which have non-local characteristics. Instantaneous alpha particle transport fluxes are significant (Γ α ~ 2 x 10 20 m –2 s –1 ) for the reversed shear regime and lower (Γ α ~ 1.1 x 10 20 m –2 s –1 ) for the monotonic q-profile case.

AE↗

Hybrid simulation of toroidal Alfvén eigenmode on the National Spherical Torus Experiment

Energetic particle modes and Alfvén eigenmodes driven by super-Alfvénic fast ions are routinely observed in neutral beam heated plasmas on the National Spherical Torus eXperiment (NSTX). These modes can significantly impact fast ion transport and thus cause fast ion redistribution or loss. Self-consistent linear simulations of Toroidal Alfvén Eigenmodes (TAEs) in NSTX plasmas have been carried out with the kinetic/magnetohydrodynamic hybrid code M3D-K using experimental plasma parameters and profiles including plasma toroidal rotation. The simulations show that unstable TAEs with n=3,4, or 5 can be excited by the fast ions from neutral beam injection. The simulated mode frequency, mode radial structure, and phase shift are consistent with measurements from a multi-channel microwave reflectometer diagnostic. A sensitivity study on plasma toroidal rotation, safety factor q profile, and initial fast ion distribution is performed. The simulations show that rotation can have a significant destabilizing effect when the rotation is comparable or larger than the experimental level. The mode growth rate is sensitive to q profile and fast ion distribution. Although mode structure and peak position depend somewhat on q profile and plasma rotation, the variation of synthetic reflectometer response is within experimental uncertainty and it is not sensitive enough to see the difference clearly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Validation of halo modeling for proton pencil beam spot scanning using a quality assurance test pattern

Purpose: The purpose of this paper is to demonstrate the utility of a comprehensive test pattern in validating calculation models that include the halo component (low-dose tails) of proton pencil beam scanning (PBS) spots. Such a pattern has been used previously for quality assurance purposes to assess spot shape, position, and dose. Methods: In this study, a scintillation detector was used to measure the test pattern in air at isocenter for two proton beam energies (115 and 225 MeV) of two IBA universal nozzles (UN #1 and UN #2). Planar measurements were compared with calculated dose distributions based on the weighted superposition of location-independent (UN #1) or location-dependent (UN #2) spot profiles, previously measured using a pair-magnification method and between two nozzles. Results: Including the halo component below 1% of the central dose is shown to improve the gamma-map comparison between calculation and measurement from 94.9% to 98.4% using 2 mm/2% criteria for the 115 MeV proton beam of UN #1. In contrast, including the halo component below 1% of the central dose does not improve the gamma agreement for the 115 MeV proton beam of UN #2, due to the cutoff of the halo component at off-axis locations. When location-dependent spot profiles are used for calculation instead of spot profiles at central axis, the gamma agreement is improved from 98.0% to 99.5% using 2 mm/2% criteria. The two nozzles clearly have different characteristics, as a direct comparison of measured data shows a passing rate of 89.7% for the 115 MeV proton beam. At 225 MeV, the corresponding gamma comparisons agree better between measurement and calculation, and between measurements in the two nozzles. Conclusions: In addition to confirming the primary component of individual PBS spot profiles, a comprehensive test pattern is useful for the validation of the halo component at off-axis locations, especially for low energy protons.

60 APPLIED LIFE SCIENCES↗

Chemical insights into the larger sooting tendency of 2-methyl-2-butene compared to n -pentane

A comprehensive, chemically detailed mechanism for the combustion of 2-methyl-2-butene and n-pentane is presented to provide insights into the different sooting tendencies of these two structurally different C5 hydrocarbons. A hierarchically assembled mechanism has been developed to specifically target speciation data from low-pressure premixed flames of 2-methyl-2-butene and newly measured mole fraction data for a fuel-rich (Φ = 1.8) n -pentane flame, in which species profiles up to phenol were quantified. The partially isomer-resolved chemical composition of this flame was determined using flame-sampling molecular-beam mass spectrometry with single-photon ionization by tunable, synchrotron-generated vacuum-ultraviolet radiation. The presented model, which includes a newly determined, consistent set of the thermochemistry data for the C5 species, presents overall satisfactory capabilities to predict the mole fraction profiles of common combustion intermediates. The analysis of the model predictions revealed the fuel-structure dependencies (i.e. saturated vs. unsaturated and linear vs. branched) of the formation of small aromatic species that are considered as soot precursors. Here, the propensity of the 2-methyl-2-butene flame to form larger concentrations of aromatic species was traced back to the readily available formation routes of several small precursor molecules and the efficient formation of “first aromatic rings” beyond benzene.

2-Methyl-2-butene↗

High Resolution Dopant Profiles Revealed by Atom Probe Tomography and STEM-EBIC for CdTe Based Solar Cells

Segregated elements and their diffusion profiles within grain boundaries and interfaces resulting from post deposition heat treatments are revealed using atom probe tomography (APT), scanning transmission electron microscopy (STEM), and electron beam induced current (EBIC) techniques. The results demonstrate how these techniques complement each other to provide conclusive evidence for locations of space charge regions and mechanisms that create them at the nanoscale. Most importantly, a Cl dopant profile that extends ~5 nm into CdTe grains interfacing the CdS is shown using APT and STEM synergy, which has been shown to push the pn-junction into the CdTe layer indicative of a homojunction (revealed by STEM EBIC). In addition, Cu and Cl concentrations within grain boundaries within several nms and µms from the CdS/CdTe interface are compared, Na segregation of <0.1% is detected, and S variations of ~1–3% are witnessed between CdTe grains close to the CdS/CdTe interface. The segregation and diffusion of these elements directly impacts on the material properties, such as band gap energy and n/p type properties. Optimization of the interfacial and grain boundary doping will lead to higher efficiency solar cells.

36 MATERIALS SCIENCE↗

The flow of plasma in the solar terrestrial environment

The development of electric fields in an expanding plasma was studied. With regard to the polar wind, it was found that hot magnetospheric electrons have a pronounced effect on the polar wind. In addition, there is no O(+) charge exchange barrier and substantial fluxes of O(+) ions can escape with the polar wind. In the auroral plasma physics area, the excitation of electrostatic waves by field aligned auroral electron beams was examined. It was demonstrated that the auroral field aligned current density can be large enough to excite Buneman double layers. For situations that lead to strong double layers, it was shown that the temporal evolution of the potential profile is controlled by current fluctuations. Two dimensional particle in cell simulations were conducted, and the high frequency wave turbulence excited by an auroral electron beam of finite width perpendicular to an ambient magnetic field was investigated. The formation of V shaped auroral potential structures was studied, and numerical simulations of double layers and auroral electric fields were reviewed.

Schunk, R. W.↗

Optimizing X-ray mirror thermal performance using matched profile cooling

To cover a large photon energy range, the length of an X-ray mirror is often longer than the beam footprint length for much of the applicable energy range. To limit thermal deformation of such a water-cooled X-ray mirror, a technique using side cooling with a cooled length shorter than the beam footprint length is proposed. This cooling length can be optimized by using finite-element analysis. For the Kirkpatrick–Baez (KB) mirrors at LCLS-II, the thermal deformation can be reduced by a factor of up to 30, compared with full-length cooling. Furthermore, a second, alternative technique, based on a similar principle is presented: using a long, single-length cooling block on each side of the mirror and adding electric heaters between the cooling blocks and the mirror substrate. The electric heaters consist of a number of cells, located along the mirror length. The total effective length of the electric heater can then be adjusted by choosing which cells to energize, using electric power supplies. The residual height error can be minimized to 0.02 nm RMS by using optimal heater parameters (length and power density). Compared with a case without heaters, this residual height error is reduced by a factor of up to 45. The residual height error in the LCLS-II KB mirrors, due to free-electron laser beam heat load, can be reduced by a factor of ~11 below the requirement. The proposed techniques are also effective in reducing thermal slope errors and are, therefore, applicable to white beam mirrors in synchrotron radiation beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unabsorbed light beamlets for diagnosing coronal density profiles and absorption nonuniformity in direct-drive implosions on OMEGA

Laser light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. The 3ωGOI (gated optical imager) beamlets diagnostic images unabsorbed light from all 60 OMEGA beams as distinct “beamlet” spots for each beam. The implosion can be diagnosed using the position and intensity of these beamlets. The position of each beamlet in the image is determined by refraction and can be used to fit the coronal plasma density profile of the implosion. The inferred plasma density profiles are comparable to profiles predicted by the 1-D hydrodynamics code LILAC but suggest the predictions underestimate the density farther out in the corona. The intensity of light in each spot depends on the cumulative effects of absorption and cross-beam energy transfer along the beamlet’s path through the corona. Furthermore, the measured variation in intensity and polarization between similar spots indicates that absorption during OMEGA implosions is less uniform than previously known.

47 OTHER INSTRUMENTATION↗

Estimating local noise power spectrum from a few FBP-reconstructed CT scans

Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has the same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available. Conclusions: The radial NPS method was shown to be accurate and efficient in estimating the local NPS of FBP-reconstructed 2D CT images. It presents strong advantages over traditional NPS methods when the number of scans is limited and can be extended to estimate the in-plane NPS of cone-beam CT and multislice helical CT scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

Performance of a hard X-ray split-and-delay optical system with a wavefront division

The performance of a hard X-ray split-and-delay optical (SDO) system with a wavefront division scheme was investigated at the hard X-ray free-electron laser facility SACLA. For the wavefront division, beam splitters made of edge-polished perfect Si(220) crystals were employed. We characterized the beam properties of the SDO system, and investigated its capabilities for beam manipulation and diagnostics. First, it was confirmed that shot-to-shot non-invasive diagnostics of pulse energies for both branches in the SDO system was feasible. Second, nearly ideal and identical focal profiles for both branches were obtained with a spot size of ~1.5 µm in full width at half-maximum. Third, a spatial overlap of the two focused beams with a sub-µm accuracy was achieved by fine tuning of the SDO system. Finally, a reliable tunability of the delay time between two pulses was confirmed. The time interval was measured with an X-ray streak camera by changing the path length of the variable-delay branch. As a result, errors from the fitted line were evaluated to be as small as ±0.4 ps over a time range of 60 ps.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

A pencil beam dose calculation model for CyberKnife system

Purpose: CyberKnife system is initially equipped with fixed circular cones for stereotactic radiosurgery. Two dose calculation algorithms, Ray-Tracing and Monte Carlo, are available in the supplied treatment planning system. A multileaf collimator system was recently introduced in the latest generation of system, capable of arbitrarily shaped treatment field. The purpose of this study is to develop a model based dose calculation algorithm to better handle the lateral scatter in an irregularly shaped small field for the CyberKnife system. Methods: A pencil beam dose calculation algorithm widely used in linac based treatment planning system was modified. The kernel parameters and intensity profile were systematically determined by fitting to the commissioning data. The model was tuned using only a subset of measured data (4 out of 12 cones) and applied to all fixed circular cones for evaluation. The root mean square (RMS) of the difference between the measured and calculated tissue-phantom-ratios (TPRs) and off-center-ratio (OCR) was compared. Three cone size correction techniques were developed to better fit the OCRs at the penumbra region, which are further evaluated by the output factors (OFs). The pencil beam model was further validated against measurement data on the variable dodecagon-shaped Iris collimators and a half-beam blocked field. Comparison with Ray-Tracing and Monte Carlo methods was also performed on a lung SBRT case. Results: The RMS between the measured and calculated TPRs is 0.7% averaged for all cones, with the descending region at 0.5%. The RMSs of OCR at infield and outfield regions are both at 0.5%. The distance to agreement (DTA) at the OCR penumbra region is 0.2 mm. All three cone size correction models achieve the same improvement in OCR agreement, with the effective source shift model (SSM) preferred, due to their ability to predict more accurately the OF variations with the source to axis distance (SAD). In noncircular field validation, the pencil beam calculated results agreed well with the film measurement of both Iris collimators and the half-beam blocked field, fared much better than the Ray-Tracing calculation. Conclusions: The authors have developed a pencil beam dose calculation model for the CyberKnife system. The dose calculation accuracy is better than the standard linac based system because the model parameters were specifically tuned to the CyberKnife system and geometry correction factors. The model handles better the lateral scatter and has the potential to be used for the irregularly shaped fields. Comprehensive validations on MLC equipped system are necessary for its clinical implementation. It is reasonably fast enough to be used during plan optimization.

60 APPLIED LIFE SCIENCES↗

Characteristics of silicon etching by silicon chloride ions

Plasmas generated from halogen-containing gases, such as Cl{sub 2} or HBr, have been widely used in gate etching processes for semiconductor chip manufacturing. Such plasmas may contain silicon halide ions formed by the ionization of etching products that enter the plasma. In this study, to illustrate Si etching by such silicon halide ions, the sputtering yield of Si by SiCl{sub x}{sup +} (with x = 1 or 3) ions has been obtained as a function of the incident ion energy by using a mass-selected ion beam injection system. It has been found that, at sufficiently low energy, the incidence of SiCl{sup +} ions leads to the deposition of Si which may affect profile control in microelectronic device fabrication processes.

36 MATERIALS SCIENCE↗

Adaptive model tuning studies for non-invasive diagnostics and feedback control of plasma wakefield acceleration at FACET-II

Beam-driven plasma wakefield acceleration (PWFA) achieves the same energy gain in a single meter, for which conventional accelerators require several kilometers, however much work is still required to match the beam quality of conventional accelerators. The PWFA processes to be studied at the FACET-II facility will utilize extremely short (down to a few fs) high energy (10 GeV), high charge (few nC) electron and eventually positron bunches. The PWFA process is extremely sensitive to the detailed longitudinal current profiles of these bunches and it would be of great benefit to have precise measurement and control of these profiles. We present an adaptive model tuning technique for FACET-II to adaptively tune online models based on real time accelerator and beam data to continuously provide a non-invasive diagnostic which predicts the longitudinal phase space (LPS) of extremely short and highly compressed electron beams, which otherwise require destructive X-band transverse deflecting cavity (XTCAV)-based measurements. Based on simulation studies, our method has the potential for: (1). The development of a non-invasive longitudinal phase space diagnostic by adaptively tuning models based on non-invasive measurements such as energy spread spectra which could be recorded at all of the bunch compressors in the facility. (2). Utilize these diagnostic to perform model-independent feedback-based to achieve desired longitudinal phase space distributions. (3). Utilize the model-independent feedback approach to maximize energy gain while minimizing emittance growth and energy gain variance of the PWFA process by tuning accelerator parameters, while monitoring what longitudinal phase space the algorithm has found, information that will be useful for further analytical and simulation studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-BRC-01: An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy

Purpose: Monte Carlo (MC) simulation is typically regarded as the most accurate dose calculation method for proton therapy. Yet for real clinical cases, the overall accuracy also depends on that of the MC beam model. Commissioning a beam model to faithfully represent a real beam requires finely tuning a set of model parameters, which could be tedious given the large number of pencil beams to commmission. This abstract reports an automatic beam-model commissioning method for pencil-beam scanning proton therapy via an optimization approach. Methods: We modeled a real pencil beam with energy and spatial spread following Gaussian distributions. Mean energy, and energy and spatial spread are model parameters. To commission against a real beam, we first performed MC simulations to calculate dose distributions of a set of ideal (monoenergetic, zero-size) pencil beams. Dose distribution for a real pencil beam is hence linear superposition of doses for those ideal pencil beams with weights in the Gaussian form. We formulated the commissioning task as an optimization problem, such that the calculated central axis depth dose and lateral profiles at several depths match corresponding measurements. An iterative algorithm combining conjugate gradient method and parameter fitting was employed to solve the optimization problem. We validated our method in simulation studies. Results: We calculated dose distributions for three real pencil beams with nominal energies 83, 147 and 199 MeV using realistic beam parameters. These data were regarded as measurements and used for commission. After commissioning, average difference in energy and beam spread between determined values and ground truth were 4.6% and 0.2%. With the commissioned model, we recomputed dose. Mean dose differences from measurements were 0.64%, 0.20% and 0.25%. Conclusion: The developed automatic MC beam-model commissioning method for pencil-beam scanning proton therapy can determine beam model parameters with satisfactory accuracy.

60 APPLIED LIFE SCIENCES↗