Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

PAMELA’S MEASUREMENTS OF MAGNETOSPHERIC EFFECTS ON HIGH-ENERGY SOLAR PARTICLES

The nature of particle acceleration at the Sun, whether through flare reconnection processes or through shocks driven by coronal mass ejections, is still under scrutiny despite decades of research. The measured properties of solar energetic particles (SEPs) have long been modeled in different particle-acceleration scenarios. The challenge has been to disentangle the effects of transport from those of acceleration. The Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) instrument enables unique observations of SEPs including the composition and angular distribution of the particles about the magnetic field, i.e., pitch angle distribution, over a broad energy range (>80 MeV)—bridging a critical gap between space-based and ground-based measurements. We present high-energy SEP data from PAMELA acquired during the 2012 May 17 SEP event. These data exhibit differential anisotropies and thus transport features over the instrument rigidity range. SEP protons exhibit two distinct pitch angle distributions: a low-energy population that extends to 90° and a population that is beamed at high energies (>1 GeV), consistent with neutron monitor measurements. To explain a low-energy SEP population that exhibits significant scattering or redistribution accompanied by a high-energy population that reaches the Earth relatively unaffected by dispersive transport effects, we postulate that the scattering or redistribution takes place locally. We believe that these are the first comprehensive measurements of the effects of solar energetic particle transport in the Earth’s magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical techniques for the analysis of stall/spin flight test data

Analytical techniques for the analysis of stall/spin flight test data are reviewed by discussing (1) certain special flight instrumentation issues, (2) the mathematical modeling techniques, and (3) the analysis of post stall and spinning flight of general aviation airplanes. The angles of attack, sideslip, roll, pitch, and yaw are derived from measurements of angular velocity and linear acceleration. The key to the success of this approach is to simultaneously estimate both the biases in the instrumentation and the initial conditions. Techniques for determining stability derivatives from flight data are applied to angles of attack too high for stabilized flight. This practice greatly expands the range over which aerodynamic characteristics can be determined from flight test. Nonlinear terms in certain aerodynamic functions are shown to be valid by comparing them with the trends of results at different angles of attack. A very old technique of studying spins is extended and applied to some modern light airplanes. Airplanes for which the wing provides the dominant moments during spins, offer the possibility of linking spin characteristics to longitudinal data.

Taylor, L. W., Jr.↗

Spin Physics Capability with Silicon Vertex Tracker for PHENIX

The PHENIX detector is being upgraded with a silicon vertex tracker (VTX) to enhance physics capability both in spin physics and heavy ion physics. In order to check the performance of the VTX, PYTHIA simulation was performed with gamma-jet production events under the condition of center-of-mass energy of 500 GeV and the integrated luminosity of 300 pb{sup -1}. We will report the simulation results of a longitudinal double-spin asymmetry A{sub LL} with the VTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{pi} p and {pi}{pi} scattering at LHC

Can we get the information on {pi} p and {pi}{pi} scattering from the LHC data? We present briefly recent results of the IHEP Diffractive Group, which include all the steps: formulation of the problem, an idea how to solve it, experimental tools, Monte-Carlo simulation and preliminary expectations concerning the first data from the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

J-PARC, facility for hadron physics, the present status and future

J-PARC was almost completed in early 2009 and started its operational era. Hadron Experimental Facility is one of the world-wide research centers for nuclear and hadron physics. The present status of the beamline and spectrometers as well as the physics program for nuclear and hadron physics is described. New beamline and experiments there are also introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of protons passing through the CR-39/PM-355 type of solid state nuclear track detectors

Solid State Nuclear Track Detectors of the CR-39/PM-355 type were irradiated with protons with energies in the range from 0.2 to 8.5 MeV. Their intensities and energies were controlled by a Si surface barrier detector located in an accelerator scattering chamber. The ranges of protons with energies of 6–7 MeV were comparable to the thickness of the PM-355 track detectors. Latent tracks in the polymeric detectors were chemically etched under standard conditions to develop the tracks. Standard optical microscope and scanning electron microscopy techniques were used for surface morphology characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental optimization of beam quality extracted from a duoplasmatron proton ion source

The LANSCE accelerator facility operates with two independent ion injectors for H⁺ and H⁻ particle beams. The H⁺ ion beam is formed using a duoplasmatron source followed by a 750 keV Cockroft-Walton accelerating column. Formation of an optimal plasma meniscus is an important feature for minimizing beam emittance, and maximizing beam brightness. A series of experiments were performed to find the optimal combination of extraction voltage and extracted current for the H⁺ beam. Measurements yielded the best ratio of beam perveance to Child–Langmuir perveance of 0.52 for maximizing beam brightness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel schemes for the optimization of the SPARC narrow band THz source

A pulsed, tunable, narrow band radiation source with frequency in the THz region can be obtained collecting the coherent transition radiation produced by a train of ultra-short electron bunches having picosecond scale inter-distance. In this paper, we review the techniques feasible at the SPARC-LAB test facility to produce and manipulate the requested train of electron bunches and we examine the dynamics of their acceleration and compression. In addition, we show how the performances of the train compression and the radiation intensity and bandwidth can be significantly improved through the insertion of a fourth order harmonic cavity, working in the X-band and acting as a longitudinal phase space linearizer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z

A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies

The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C{sub 60} using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of changes in linear accelerator photon energy through flatness variation using an ion chamber array

Purpose: To compare the use of flatness versus percent depth dose (PDD) for determining changes in photon beam energy for a megavoltage linear accelerator. Methods: Energy changes were accomplished by adjusting the bending magnet current by up to {+-}15% in 5% increments away from the value used clinically. Two metrics for flatness, relative flatness in the central 80% of the field (Flat) and average maximum dose along the diagonals normalized by central axis dose (F{sub DN}), were measured using a commercially available planner ionization chamber array. PDD was measured in water at depths of 5 and 10 cm in 3 Multiplication-Sign 3 cm{sup 2} and 10 Multiplication-Sign 10 cm{sup 2} fields using a cylindrical chamber. Results: PDD was more sensitive to changes in energy when the beam energy was increased than when it was decreased. For the 18-MV beam in particular, PDD was not sensitive to energy reductions below the nominal energy. The value of Flat was found to be more sensitive to decreases in energy than to increases, with little sensitivity to energy increases above the nominal energy for 18-MV beams. F{sub DN} was the only metric that was found to be sensitive to both increases and reductions of energy for both the 6- and 18-MV beams. Conclusions: Flatness based metrics were found to be more sensitive to energy changes than PDD, In particular, F{sub DN} was found to be the most sensitive metric to energy changes for photon beams of 6 and 18 MV. The ionization chamber array allows this metric to be conveniently measured as part of routine accelerator quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

Waste Management Analyses for Spent Structures at SNS - Paper 106

The Spallation Neutron Source (SNS) in Oak Ridge, Tennessee, is an accelerator driven neutron scattering facility for materials research. Presently, the SNS operates at 1.2 megawatt (MW) proton beam power incident on a mercury target with a proton beam energy of 1 GeV and 60 Hz repetition rate. The SNS consists of an accelerator facility, target facility, and a world-class suite of neutron scattering instruments supporting material, life-science and fundamental physics research. According to the SNS operations plan, some components are replaced when they reach their end-of-life due to radiation induced material damage or burn-up, or because of mechanical failure. During operation, these components, especially those in proximity to the target, are exposed to a radiation environment and build up significant activity during their service lifetime. All these components must be safely removed, placed in a container/package for storage, and ultimately transported offsite for disposal. An accurate estimate of the radionuclide inventory is performed assuming realistic irradiation history and decay time in order to classify a spent component. On the basis of a calculated radionuclide inventory, the spent component is classified, and an appropriate cask/package for transport and storage is suggested. After the choice for the container is made, radiation transport calculations are performed for the facility component placed inside the container, to ensure that the container is compliant with waste management regulations. When necessary, additional shielding is added. For each spent component before it goes out of the SNS site, supporting documentation is produced with a radionuclide inventory prediction, dose rate analyses and, if required, additional shielding. A dose rate analyses for the exposure prediction of personnel during components change out are performed as well. Most of the effort is concentrated on the target facility components such as target, proton beam window (PBW) and core vessel insert (CVI) plugs because of severe radiation conditions. Additionally, analyses are performed for the accelerator facility components, which are removed from the facility. Activation analyses and residual dose rates analyses are performed to support safe handling of SNS spent components at the SNS site and during transport to the waste disposal site. On the basis of the calculated radionuclide inventories, spent components characterized and classified with respect to waste management guidelines, and activity-based determinations are made regarding appropriate packaging for transport. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerated Adaptive MGS Phase Retrieval

The Modified Gerchberg-Saxton (MGS) algorithm is an image-based wavefront-sensing method that can turn any science instrument focal plane into a wavefront sensor. MGS characterizes optical systems by estimating the wavefront errors in the exit pupil using only intensity images of a star or other point source of light. This innovative implementation of MGS significantly accelerates the MGS phase retrieval algorithm by using stream-processing hardware on conventional graphics cards. Stream processing is a relatively new, yet powerful, paradigm to allow parallel processing of certain applications that apply single instructions to multiple data (SIMD). These stream processors are designed specifically to support large-scale parallel computing on a single graphics chip. Computationally intensive algorithms, such as the Fast Fourier Transform (FFT), are particularly well suited for this computing environment. This high-speed version of MGS exploits commercially available hardware to accomplish the same objective in a fraction of the original time. The exploit involves performing matrix calculations in nVidia graphic cards. The graphical processor unit (GPU) is hardware that is specialized for computationally intensive, highly parallel computation. From the software perspective, a parallel programming model is used, called CUDA, to transparently scale multicore parallelism in hardware. This technology gives computationally intensive applications access to the processing power of the nVidia GPUs through a C/C++ programming interface. The AAMGS (Accelerated Adaptive MGS) software takes advantage of these advanced technologies, to accelerate the optical phase error characterization. With a single PC that contains four nVidia GTX-280 graphic cards, the new implementation can process four images simultaneously to produce a JWST (James Webb Space Telescope) wavefront measurement 60 times faster than the previous code.

Lam, Raymond K.↗

Design of high power radio frequency radial combiner for proton accelerator

A simplified design method has been proposed for systematic design of novel radio frequency (rf) power combiner and divider, incorporating radial slab-line structure, without using isolation resistor and external tuning mechanism. Due to low insertion loss, high power capability, and rigid mechanical configuration, this structure is advantageous for modern solid state rf power source used for feeding rf energy to superconducting accelerating structures. Analysis, based on equivalent circuit and radial transmission line approximation, provides simple design formula for calculating combiner parameters. Based on this method, novel 8-way and 16-way power combiners, with power handling capability of 4 kW, have been designed, as part of high power solid state rf amplifier development. Detailed experiments showed good performance in accordance with theory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact 300 kV solid-state high-voltage nanosecond generator for dielectric wall accelerator

Compact solid-state system is the main development trend in pulsed power technologies. A compact solid-state high-voltage nanosecond pulse generator with output voltage of 300 kV amplitude, 10 ns duration (FWHM), and 3 ns rise-time was designed for a dielectric wall accelerator. The generator is stacked by 15 planar-plate Blumlein pulse forming lines (PFL). Each Blumlein PFL consists of two solid-state planar transmission lines, a GaAs photoconductive semiconductor switch, and a laser diode trigger. The key components of the generator and the experimental results are reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of imaging plate for GeV electrons

An imaging plate has been used as a useful detector of energetic electrons in laser electron acceleration and laser fusion studies. The absolute sensitivity of an imaging plate was calibrated at 1 GeV electron energy using the injector Linac of SPring-8. The sensitivity curve obtained up to 100 MeV in a previous study was extended successfully to GeV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗