Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Controlling Mirror Tilt With A Bimorph Actuator

Proposed mirror-tilting actuator based on bimorph cells. Includes microprocessor determining desired direction, speed, and maximum tilt angle and converts data to control signals. Multiplexer applies control signals to circuits that apply actuation voltages to individual bimorphs. Advantages include light weight, small size, and low power. Provides controllable tilt of mirror in copy machine or optical scanner, for example.

Bar-Cohen, Yoseph↗

NASA’s Quiet Electric ENgines (QUEEN): Thermal Analysis and Testing of the Electronic Speed Controller (ESC)

An electric ducted fan system was tested at the NASA Glenn Research Center. Main components of the system include a commercial-off-the-Shelf (COTS) fan and motor, electronic speed controller, and cooling system. Motor speed, voltage, current, and temperatures were measured in this static ground test of the propulsor. The thermal performance of the Electronic Speed Controller (ESC) was also measured using two different methods to cool the ESC: air cooling and cold plate cooling. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Single Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large regional single-aisle aircraft. Lessons learned will be used to guide development of future QUEEN prototypes and thermal management systems.

Firas G Asfoor↗

Voltage regulator for battery power source

A bipolar transistor in series with the battery as the control element also in series with a zener diode and a resistor is used to maintain a predetermined voltage until the battery voltage decays to very nearly the predetermined voltage. A field effect transistor between the base of the bipolar transistor and a junction between the zener diode and resistor regulates base current of the bipolar transistor, thereby regulating the conductivity of the bipolar transistor for control of the output voltage.

Black, J. M.↗

A Comparative Study of the Application of FACTS Devices in Wind Power Plants of the Southeast Area of the Mexican Electric System

This paper presents a comparative study of the application of Flexible AC Transmission System (FACTS) devices, as Thyristor Controlled Series Capacitor (TCSC), Static Synchronous Compensator (STATCOM) and Unified Power Controller (UPFC) on congestion management and voltage support in the area of the Istmo of Tehuantepec, Oaxaca, Mexico. The present work provides an analysis about the performance of the control of active and reactive power of the FACTS controllers applied to mentioned problems in the power system.

17 WIND ENERGY↗

Resonant plasmonic terahertz detection in vertical graphene-base hot-electron transistors

We analyze dynamic properties of vertical graphene-base hot-electron transistors (GB-HETs) and consider their operation as detectors of terahertz (THz) radiation using the developed device model. The GB-HET model accounts for the tunneling electron injection from the emitter, electron propagation across the barrier layers with the partial capture into the GB, and the self-consistent oscillations of the electric potential and the hole density in the GB (plasma oscillations), as well as the quantum capacitance and the electron transit-time effects. Using the proposed device model, we calculate the responsivity of GB-HETs operating as THz detectors as a function of the signal frequency, applied bias voltages, and the structural parameters. The inclusion of the plasmonic effect leads to the possibility of the GB-HET operation at the frequencies significantly exceeding those limited by the characteristic RC-time. It is found that the responsivity of GB-HETs with a sufficiently perfect GB exhibits sharp resonant maxima in the THz range of frequencies associated with the excitation of plasma oscillations. The positions of these maxima are controlled by the applied bias voltages. The GB-HETs can compete with and even surpass other plasmonic THz detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

Power↗

Experimental investigation of the excess charge and time constant of minority carriers in the thin diffused layer of 0.1 Ohm-cm silicon solar cells

The observed low open-circuit voltage in 0.1 Ohm-cm solar cells is probably related to an excessively high diode saturation current. Theoretical studies conducted by Lindholm et al. (1975) and by Godlewski et al. (1975) have shown that a high saturation current could be produced by either high recombination rates or bandgap narrowing effects. A description is given of an investigation which shows that bandgap narrowing effects have a first order significance in determining the charge carrier transport controlling the open-circuit voltage of 0.1 Ohm-cm silicon solar cells.

Godlewski, M. P.↗

On Control Schemes for Grid-Forming Inverters

Grid-forming inverters can collaboratively regulate the voltage and frequency of a microgrid. These inverters are expected to be seen more in the future microgrid, undertaking the roles of the conventional power generators. Like conventional power generators, they must balance supply and demand, contribute to power-sharing between inverters and other power generators, and restore the voltage and frequency after any power changes. These technical challenges are typically achieved through different primary and secondary controllers. This article reviews some state-of-the-art primary and secondary control schemes for the emerging technology of grid-forming inverters. First, the typical control schemes for grid-following inverters are briefly presented for the continuity of the discussion on the roles of the grid-forming inverters in future power-grid, followed by two basic control schemes for the grid-forming inverters. Then, two decentralized power-sharing techniques, i.e., droop, and virtual inertia, are analyzed. The technical challenges for inverter synchronization and some control methods are discussed afterward. Finally, several secondary control methods for the voltage and frequency restoration in grid-forming inverters are reviewed.

Sadeque, Fahmid↗

Load power device, system and method of load control and management employing load identification

A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spectral shape deformation in inverse spin Hall voltage in Y{sub 3}Fe{sub 5}O{sub 12}|Pt bilayers at high microwave power levels

We report on the deformation of microwave absorption spectra and of the inverse spin Hall voltage signals in thin film bilayers of yttrium iron garnet (YIG) and platinum at high microwave power levels in a 9.45-GHz TE{sub 011} cavity. As the microwave power increases from 0.15 to 200 mW, the resonance field shifts to higher values, and the initially Lorentzian spectra of the microwave absorption intensity as well as the inverse spin Hall voltage signals become asymmetric. The contributions from opening of the magnetization precession cone and heating of YIG cannot well reproduce the data. Control measurements of inverse spin Hall voltages on thin-film YIG|Pt systems with a range of line widths underscore the role of spin-wave excitations in spectral deformation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control of an average output power of a CuBr laser

We have studied the pump parameters of a CuBr laser (pulse repetition rate of 14 kHz) with an independent heating of the active medium and an additional excitation source, providing an operational control of the radiation parameters in a given time interval. We have fabricated an experimental setup that makes it possible to change the average output power by applying a control pulse which is ahead of the main pulse by 0.12 - 20 {mu}s. It is shown that to ensure the effective control of the laser power, the voltage amplitude of the additional excitation pulse should be within 12 % - 28 % of the main pulse amplitude. In this case, the proposed control regime allows a 2.5-fold decrease in the time delay between the control and main excitation pulses due to a higher energy of the additional pulse compared to self-heating regime of the laser operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft Actor Critic Based Volt-VAR Co-optimization in Active Distribution Grids

Modern distribution networks are undergoing several technical challenges, such as voltage fluctuations, because of high penetration of distributed energy resources (DERs). This paper proposes a deep reinforcement learning (DRL)-based Volt VAR co-optimization technique for reducing voltage fluctuations as well as power loss under high penetration of DERs. In addition, the proposed approach minimizes the operational cost of the grid. A stochastic policy optimization based soft actor critic (SAC) agent is proposed to configure the optimal set-points of the reactive power outputs of the inverters. The performance of the proposed model is verified on the modified IEEE 34- and 123-bus systems and compared with a base case scenario with no reactive supply by inverters, and a local droop control approach. The results demonstrate that the proposed framework outperforms the conventional droop control method in improving the voltage profile, minimizing the network power loss, and reducing grid operational cost.

—Distribution grids, deep reinforcement learning, ↗

System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m{sup 2}. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). (author)

14 SOLAR ENERGY↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Economic evaluation of distribution system smart grid investments

This paper investigates economic benefits of smart grid automation investments. A system consisting of 7 substations and 14 feeders is used in the evaluation. Here benefits that can be quantified in terms of dollar savings are considered, termed “hard dollar” benefits. Smart Grid investment evaluations to be considered include investments in improved efficiency, more cost effective use of existing system capacity with automated switches, and coordinated control of capacitor banks and voltage regulators. These Smart Grid evaluations are sequentially ordered, resulting in a series of incremental hard dollar benefits. Hard dollar benefits come from improved efficiency, delaying large capital equipment investments, shortened storm restoration times, and reduced customer energy use. Analyses used in the evaluation involve hourly power flow analysis over multiple years and Monte Carlo simulations of switching operations during storms using a reconfiguration for restoration algorithm. The economic analysis uses the time varying value of the Locational Marginal Price. Algorithms used include reconfiguration for restoration involving either manual or automated switches and coordinated control involving two modes of control. Field validations of phase balancing and capacitor design results are presented. The evaluation shows that investments in automation can improve performance while at the same time lowering costs.

25 ENERGY STORAGE↗

Real-time Implementation of a Dual-Active-Bridge Based Multi-Level Photovoltaic Converter

Silicon-carbide based, multi-level converters with dual-active-bridge (DAB) are getting attention for medium voltage, direct grid-connected, utility-scale photovoltaic (PV) applications due to their higher efficiency and power density. To de-risk complex control development for these high-voltage and high-power inverters, hardware-in-the-loop techniques are often required. Due to the high switching frequency and the large number of power electronic switches, off-the-shelf, real-time simulation tools are not yet fully developed for this application, even with FPGA-based simulators. To address this, a new co-simulation approach in FPGA is presented that utilizes Time-Stamped Bridge (TSB) for the higher frequency converters along with detailed fixed conductance based discrete device simulation of the rest of the circuit. A complex DAB-based PV converter with maximum switching frequency of 50 kHz is successfully simulated in real-time in the FPGA and the results are compared with offline simulation results. A controller hardware-in-the-loop (CHIL) platform is developed to demonstrate real-time, closed-loop test results for this DAB-based PV converter.

Dong, Zerui↗

Grid FriendlyTM Device Model Development and Simulation

In late 2007, the Bonneville Power Administration (BPA) contracted Pacific Northwest National Laboratory (PNNL) to complete a research project titled Grid-Responsive Demand-Side Control Using Grid Friendly Appliance Technologies [Hammerstrom 2009, DeSteese and Hammerstrom 2009]. Cosponsors included Portland General Electric (PGE) and Puget Sound Energy (PSE). The project focused on applications of the Grid Friendly Appliance (GFA) controller, which is an autonomous controller that was designed to advise devices like appliances concerning valuable demand-side grid services that should be conducted. The controller bases its advice on observations it makes from the ac voltage signal. Electric tank water heaters were selected to be controlled by the GFA controller in this project. Two autonomous responses are addressed herein. First, an under-voltage-responsive water heater is able to recognize sudden reductions in feeder circuit voltage at each water heater and may curtail any electric load that is being consumed by the water heater. These under-voltage events are usually induced by nearby electrical faults. An under-voltage response is necessarily specified by the set of voltage thresholds at which the responsive water heaters would respond. The set of voltages at which the curtailment would be released must also be specified. Additionally, any delays prior to the water heater load becoming curtailed or again released must be specified. For example, a delay may be intentionally imposed prior to curtailing water heater loads to avoid responses during the fault itself. Much longer and randomized delays should be imposed prior to the release of curtailments in order to re-establish diversity of the water heater loads and soften what could otherwise be an abrupt reintroduction of a large aggregated electrical load into the already stressed grid region.

24 POWER TRANSMISSION AND DISTRIBUTION↗