Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Active Power Control of Wind Turbines for Ancillary Services: A Comparison of Pitch and Torque Control Methodologies

As wind energy generation becomes more prevalent in some regions, there is increased demand for wind power plants to provide ancillary services, which are essential for grid reliability. This paper compares two different wind turbine control methodologies to provide active power control (APC) ancillary services, which include derating or curtailing power generation, providing automatic generation control (AGC), and providing primary frequency control (PFC). The torque APC controller provides all power control through the power electronics whereas the pitch APC controller uses the blade pitch actuators as the primary means of power control. These controllers are simulated under various wind conditions with different derating set points and AGC participation levels. The metrics used to compare their performance are the damage equivalent loads (DELs) induced on the structural components and AGC performance metrics, which are used to determine the payments for AGC services by system operators in the United States. The simulation results show that derating the turbine reduces structural loads for both control methods, with the APC pitch control providing larger reductions in DELs, lower AGC performance scores, and higher root-mean-square pitch rates. Providing AGC increases the structural loads when compared to only derating the turbine, but even the AGC DELs are generally lower than those of the baseline control system. The torque APC control methodology also allows for more sustained PFC responses under certain derating conditions.

17 WIND ENERGY↗

Learning Sequential Distribution System Restoration via Graph-Reinforcement Learning

We report a distribution service restoration algorithm as a fundamental resilient paradigm for system operators provides an optimally coordinated, resilient solution to enhance the restoration performance. The restoration problem is formulated to coordinate distribution generators and controllable switches optimally. A model-based control scheme is usually designed to solve this problem, relying on a precise model and resulting in low scalability. To tackle these limitations, this work proposes a graph-reinforcement learning framework for the restoration problem. We link the power system topology with a graph convolutional network, which captures the complex mechanism of network restoration in power networks and understands the mutual interactions among controllable devices. Latent features over graphical power networks produced by graph convolutional layers are exploited to learn the control policy for network restoration using deep reinforcement learning. The solution scalability is guaranteed by modeling distributed generators as agents in a multi-agent environment and a proper pre-training paradigm. Comparative studies on IEEE 123-node and 8500-node test systems demonstrate the performance of the proposed solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biosecurity through Public Health System Design.

We applied modeling and simulation to examine the real-world tradeoffs between developingcountry public-health improvement and the need to improve the identification, tracking, and security of agents with bio-weapons potential. Traditionally, the international community has applied facility-focused strategies for improving biosecurity and biosafety. This work examines how system-level assessments and improvements can foster biosecurity and biosafety. We modeled medical laboratory resources and capabilities to identify scenarios where biosurveillance goals are transparently aligned with public health needs, and resource are distributed in a way that maximizes their ability to serve patients while minimizing security a nd safety risks. Our modeling platform simulates key processes involved in healthcare system operation, such as sample collection, transport, and analysis at medical laboratories. The research reported here extends the prior art by provided two key compone nts for comparative performance assessment: a model of patient interaction dynamics, and the capability to perform uncertainty quantification. In addition, we have outlined a process for incorporating quantitative biosecurity and biosafety risk measures. Two test problems were used to exercise these research products examine (a) Systemic effects of technological innovation and (b) Right -sizing of laboratory networks.

60 APPLIED LIFE SCIENCES↗

The Phenix ultimate natural convection test

The French sodium cooled fast reactor Phenix was shut down in 2009 after 35 years of operation. Before decommissioning, a final set of tests were performed by the CEA during 9 months. Several topics were involved such as thermal hydraulics, core physics and fuel behaviour. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip of one secondary pump and a natural convection test in the primary circuit. Recognizing the unique opportunity offered by these Phenix ultimate tests, IAEA decided in 2007 to launch a Coordinated Research Project (CRP) devoted to benchmarking analyses with system codes on the Phenix natural convection test. One objective of the natural convection test in Phenix reactor is the assessment of the CATHARE system code for safety studies on future and advanced sodium cooled fast reactors. The aim of this paper is to describe this test, which was performed on June 22-23, 2009, and the associated benchmark specifications for the CRP work. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. After that, the test scenario is described: - initial state at a power of 120 MWth, - test beginning resulting from a manual dry out of the two steam generators, - manual scram, - manual trip on the three primary pumps without back-up by pony motors, - setting and development of natural convection in the primary circuit, in a first phase without significant heat sink in the secondary circuits and in a second phase with significant heat sink in the secondary circuits, by opening the casing of steam generators to create an efficient heat sink, by air natural circulation in the steam generators casing. The benchmark case ends after this second phase, which corresponds to the experimental test duration of nearly 7 hours. The paper presents also the benchmark specifications data supplied by the CEA to all participants of this CRP in order to perform calculations (core, primary circuit, primary pumps, IHX, shutdown system, operating parameters, test scenario and real test conditions). Finally, main test results and analyses are presented including the evolution of the core and of the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The natural convection has been easily set up in the pool type reactor Phenix with different boundary conditions at the secondary side, with or without heat sink. The data obtained during this unique test represent some very useful and precious results for the development of SFR in a wide range of thematic such as numerical methods dedicated to thermal-hydraulics safety analyses (system codes, CFD codes and coupling system and CFD codes) and instrumentation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Variable Speed Air-Source Integrated Heat Pump (AS-IHP) Development (Final Report)

Between August 2011 and September 2015, Oak Ridge National Laboratory (ORNL) and Nordyne, LLC (now Nortek Global HVAC LLC, NGHVAC) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. Two generations of laboratory prototype systems were designed, fabricated, and lab-tested during 2011-2013. Performance maps for the system were developed using the latest research version of the DOE/ORNL Heat Pump Design Model, or HPDM, (Rice 1991; Rice and Jackson 2005; Shen et al 2012) as calibrated against the lab test data. These maps were the input to the TRNSYS (SOLAR Energy Laboratory, et al, 2010) system to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of 13 SEER air-source heat pump (ASHP) and resistance water heater with Energy Factor (EF) of 0.9). Predicted total annual energy savings, while providing space conditioning and water heating for a tight, well insulated 2600 ft2 (242 m2) house at 5 U.S. locations, ranged from 46 to 61%, averaging 52%, relative to the baseline system (lowest savings at the cold-climate Chicago location). Predicted energy use for water heating was reduced 62 to 76% relative to resistance WH. Based on these lab prototype test and analyses results a field test prototype was designed and fabricated by NGHVAC. The unit was installed in a 2400 ft2 (223 m2) research house in Knoxville, TN and field tested from May 2014 to April 2015. Based on the demonstrated field performance of the AS-IHP prototype and estimated performance of a baseline system operating under the same loads and weather conditions, it was estimated that the prototype would achieve ~40% energy savings relative to the minimum efficiency suite. The estimated WH savings were >60% and SC mode savings were >50%. But estimated SH savings were only about 20%. It is believed that had the test house been better insulated (more like the house used for the savings predictions noted above) and the IHP system nominal capacity been a bit lower that the energy savings estimate would have been closer to 45% or more (similar to the analytical prediction for the cold climate location of Chicago).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vadose Zone Model for B-3 Pond for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3. Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The scope of this ECF is to document the development and results of the B-3 Pond vadose zone model. The B-3 Pond model covers the main lobe of the 216-B-3 Pond System located in a topographic low east of the 200 East Area. The pond system operated from 1945 to 1997 and received effluents from the Plutonium Uranium Extraction Plant, B Plant, 284-E Powerhouse, and other 200 East Area facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Distributed Energy Resource Management Systems Using Software- and Hardware-in-the-Loop

Distributed energy resource management systems (DERMS) are an important emerging technology for coordinating distributed energy resources (DERs) integrated in power distribution networks. These solutions implement a software platform to monitor, control, and coordinate DERs in real time to provide aggregate grid services to the electric utility or distribution system operator. To move DERMS technology forward, research and performance validation in a laboratory environment are needed to ensure proper function of DERMS prior to field deployment. This presentation presents a generic hardware-in-the-loop (HIL) platform to evaluate performance of DERMS using software-in-the-loop (SIL) and power HIL. The platform provides realistic testing in a laboratory environment, including accurate modeling of full-scale distribution systems, DERMS software controllers, and at-power distributed energy resources (DERs), such as solar and battery inverters. Two case studies are presented to demonstrate how the platform can be used independently as an integrated development and validation approach for different projects. Laboratory testing results are included to showcase the voltage regulation performance of each study and the benefits of implementing such a platform for DERMS evaluation.

DERMS↗

Approximating Trajectory Constraints With Machine Learning – Microgrid Islanding With Frequency Constraints

Here, we introduce deep earning aided constraint encoding to tackle the frequency-constraint microgrid scheduling problem. The nonlinear function between system operating condition and frequency nadir is approximated by using a neural network, which admits an exact mixed-integer formulation (MIP). This formulation is then integrated with the scheduling problem to encode the frequency constraint. With the stronger representation power of the neural network, the resulting commands can ensure adequate frequency response in a realistic setting in addition to islanding success. The proposed method is validated on a modified 33-node system. Successful islanding with a secure response is simulated under the scheduled commands using a detailed three-phase model in Simulink. The advantages of our model are particularly remarkable when the inertia emulation functions from wind turbine generators are considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

Normetex Pump Alternatives Study

A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying resistances to ionizing radiation - aromatic polymers such as polyimide Vespel (TM) and the elastomer EPDM (ethylene propylene diene monomer) have been found to be more resistant to degradation in tritium than other polymers. This report presents information to help select replacement pumps for Normetex pumps in tritium systems. Several pumps being considered as Normetex replacement pumps are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Resilient design in nuclear energy: Critical lessons from a cross-disciplinary analysis of the Fukushima Dai-ichi nuclear accident

This paper presents a multidisciplinary analysis of the Fukushima Dai-ichi Nuclear Power Plant accident. Along with the latest observations and simulation studies, we synthesize the time-series and event progressions during the accident across multiple disciplines, including in-plant physics and engineering systems, operators’ actions, emergency responses, meteorology, radionuclide release and transport, land contamination, and health impacts. We identify three key factors that exacerbated the consequences of the accident: (1) the failure of Unit 2 containment venting, (2) the insufficient integration of radiation measurements and meteorology data in the evacuation strategy, and (3) the limited risk assessment and emergency preparedness. We conclude with new research and development directions to improve the resilience of nuclear energy systems and communities, including (1) meteorology-informed proactive venting, (2) machine learning-enabled adaptive evacuation zones, and (3) comprehensive risk-informed emergency planning while leveraging the experience from responses to other disasters.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Algal Supply System Design - Harmonized Version

The objective of this design report is to provide an assessment of current technologies used for production, dewatering, and converting microalgae cultivated in open-pond systems to biofuel. The original draft design was created in 2011 and has subsequently been brought into agreement with the DOE harmonized model. The design report extends beyond this harmonized model to discuss some of the challenges with assessing algal production systems, including the ability to (1) quickly assess alternative algal production system designs, (2) assess spatial and temporal variability, and (3) perform large-scale assessments considering multiple scenarios for thousands of potential sites. The Algae Logistics Model (ALM) was developed to address each of these limitations of current modeling efforts to enable assessment of the economic feasibility of algal production systems across the United States. The (ALM) enables (1) dynamic assessments using spatiotemporal conditions, (2) exploration of algal production system design configurations, (3) investigation of algal production system operating assumptions, and (4) trade-off assessments with technology decisions and operating assumptions. The report discusses results from the ALM, which is used to assess the baseline design determined by harmonization efforts between U.S. DOE national laboratories. Productivity and resource assessment data is provided by coupling the ALM with the Biomass Assessment Tool developed at PNNL. This high-fidelity data is dynamically passed to the ALM and used to help better understand the impacts of spatial and temporal constraints on algal production systems by providing a cost for producing extracted algal lipids annually for each potential site.

09 BIOMASS FUELS↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilization of Supercapacitors in Adaptive Protection Applications for Resiliency against Communication Failures: A Size and Cost Optimization Case Study

Microgrids’ adaptive protection techniques rely on communication signals from the point of common coupling to ad- just the corresponding relays’ settings for either grid-connected or islanded modes of operation. However, during communication out- ages or in the event of a cyberattack, relays settings are not changed. Thus adaptive protection schemes are rendered unsuc- cessful. Due to their fast response, supercapacitors, which are pre- sent in the microgrid to feed pulse loads, could also be utilized to enhance the resiliency of adaptive protection schemes to communi- cation outages. Proper sizing of the supercapacitors is therefore im- portant in order to maintain a stable system operation and also reg- ulate the protection scheme’s cost. This paper presents a two-level optimization scheme for minimizing the supercapacitor size along with optimizing its controllers’ parameters. The latter will lead to a reduction of the supercapacitor fault current contribution and an increase in that of other AC resources in the microgrid in the ex- treme case of having a fault occurring simultaneously with a pulse load. It was also shown that the size of the supercapacitor can be reduced if the pulse load is temporary disconnected during the transient fault period. Simulations showed that the resulting super- capacitor size and the optimized controller parameters from the proposed two-level optimization scheme were feeding enough fault currents for different types of faults and minimizing the cost of the protection scheme.

25 ENERGY STORAGE↗

Developing and Extending a Cyberinfrastructure Model

Increasingly, research and education institutions are realizing the strategic value and challenge of deploying and supporting institutional cyberinfrastructure (CI). Cyberinfrastructure is composed of high performance computing systems, massive storage systems, visualization systems, and advanced networks to interconnect the components within and across institutions and research communities. CI also includes the professionals with expertise in scientific application and algorithm development and parallel systems operation. Unlike ?regular? IT infrastructure, the manner in which the components are configured and skills to do so are highly specific and specialized. Planning and coordinating these assets is a fundamental step toward enhancing an institution?s research competitiveness and return on personnel, technology, and facilities investments. Coordinated deployment of CI assets has implications across the institution. Consider the VC for Research whose new faculty in the Life Sciences are now asking for simulation systems rather than wet labs, or the Provost who lost another faculty candidate to a peer institution that offered computational support for research, or the VC for Administration who has seen a spike in power and cooling demands from many of the labs and office spaces being converted to house systems. These are just some of the issues that research institutions are wrestling with as research becomes increasingly computational, data-intensive and interdisciplinary. This bulletin will discuss these issues and will present an approach for developing a cyberinfrastructure model that was successfully developed at one institution and then deployed across institutions.

99 GENERAL AND MISCELLANEOUS↗

A Deep Reinforcement Learning-based Reserve Optimization in Active Distribution Systems for Tertiary Frequency Regulation

Federal Energy Regulatory Commission (FERC)Orders 841 and 2222 have recommended that distributed energy resources (DERs) should participate in energy and reserve markets; therefore, a mechanism needs to be developed to facilitate DERs’ participation at the distribution level. Although the available reserve from a single distribution system may not be sufficient for tertiary frequency regulation, stacked and coordinated contributions from several distribution systems can enable them participate in tertiary frequency regulation at scale. This paper proposes a deep reinforcement learning (DRL)-based approach for optimization of requested aggregated reserves by system operators among the clusters of DERs. The co-optimization of cost of reserve, distribution network loss, and voltage regulation of the feeders are considered while optimizing the reserves among participating DERs. The proposed framework adopts deep deterministic policy gradient (DDPG), which is an algorithm based on an actor-critic method. The effectiveness of the proposed method for allocating reserves among DERs is demonstrated through case studies on a modified IEEE 34-node distribution system.

deep reinforcement learning, distributed energy re↗

Impedance Emulation Control of Wave Energy Converters

Modeling and control of wave energy conversion (WEC) systems for maximum power extraction is challenging due to complex multiphysics that include fluids, mechanics, and machine drives. To uncover an intuitive model that clearly depicts WEC system operation, we utilize a force-current equivalent circuit framework which then enables us to design an impedance emulation control strategy. To provide context for our framework, we focus on a standard reference model-3 (RM3) point absorber device coupled to a permanent magnet synchronous generator. After the proposed extremum seeking controller is computed, we experimentally validate its performance on a platform that consists of two back-to-back connected inverters that emulate the WEC system.

wave energy conversion, impedance emulation, machi↗