Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Security Analysis of a Class of Secured Spread Spectrum Systems

Abstract—A method of adding physical layer security to a class of spread spectrum systems has been recently proposed. In this paper, we look into the rate at which an eavesdropper may gain information about the system to decipher the data symbols. The Shannon mutual information is used to measure the rate of information that may be gained by an eavesdropper. The k-nearest neighbors (k-NN) method is used to obtain the estimates of relevant entropy values which will be then used to quantify the rate of information recovery as more data are being transmitted. It turns out that such information recovery requires adoption of special methods that avoid any destructive bias in the estimates. Details of these methods are also presented.

97 - MATHEMATICS AND COMPUTING↗

pvplr-python: Python package implementation of PVplr for Performance Loss Rate (PLR) analysis

Due to software fragmentation, PV system modeling teams can be limited to language specific packages, preventing cross-sectional analysis of different modeling techniques and workflows. To this end, PVplr, a popular PV performance modeling R software package, has been ported to the Python programming language. To verify and test the robustness of the port, NSRDB data has been used to simulated PV installations at native resolution (~2 million Sites), with a variety of degradation rates, degradation patterns, and modules. Performance Ratios were calculated using the ported functions from pvplr-python and compared against Rdtools YoY values. Due to the complicated nature of degradation, a new metric has been proposed to quantify the performance loss of a system. The cumulative production loss, is the total amount of energy lost due to the degrading performance of the system. Cumulative production loss alleviates the problems with fitting linear functions to non-linear degradation. Cumulative Production loss was shown to better estimate the total lost revenue for non-linear degradation patterns. $XbX + UTC$ was found to most accurately predict the total lost revenue in simulated systems.

Kumar, Suraj↗

Comprehensive Efficiency Analysis of Current Source Inverter Based SPM Machine Drive System for Traction Applications

A current-source inverter (CSI) has the natural capability of boosting the output voltage which is a notable advantage over voltage source inverter (VSI) in traction drive applications. This paper investigates the voltage boosting feature of the CSI to improve the overall efficiency of the CSI-based surface permanent magnet (SPM) machine drive system in the constant power region. The effects of the boost function on the total system losses, including the machine copper loss, core loss, and magnet loss, as well as the device conduction and switching loss in the CSI and dc/dc converter, are described using analytical models. The operating characteristics of the machine and CSI are validated by 2-D finite-element analysis (FEA) and simulations. Based on the loss model, the effects of the modulation index on the overall drive system losses and power factor have been analyzed. A genetic algorithm has been used to optimize the CSI's boost ratio, demonstrating that the drive system efficiency can be increased by 1% to 2.5% along the constant-power regime envelope by using the boost function.

current source inverter, genetic algorithm, SPM ma↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

Translytics: A Novel Approach for Runtime Selection of Database Layout Based on User’s Context

Currently, organizations have to maintain separate systems for transactions and analytics inside the company. Notably, different vendors provide the capabilities for either of these tasks that require specialized hardware or software. Data engineers are required to retrieve data from one source and transform it into another format to obtain the maximum benefit in a minimum time. Organizations strive for a competitive advantage that is achieved by fetching data from their customers and getting insights earliest for timely decision making. Present practices do not permit the view of the latest data for analytics since the first data have to be fetched from the source, transformed, and loaded to other systems to be utilized for analysis by relevant teams. This paper introduces a single system for both transactions and analytics. Our proposed solution would permit companies to seamlessly adapt our solution without the need to shift all of their data to newer systems and allow all the teams. It would grant all the teams to have a view of the latest available data without extra expertise and budget.

Tanvir, Muhammad Makhshif↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Design of Auxiliary Circuit Elements for Achieving Zero Voltage Switching in a Wireless Power Transfer System

The auxiliary resonant commutated pole (ARCP) is being used to achieve zero voltage switching (ZVS) of power switches for improved efficiency and/or to reduce dv/dt at the switch node for better electromagnetic interference (EMI) performance and overall system reliability. This paper shows how an ARCP circuit can be used in a wireless power transfer system to achieve ZVS. Detailed analysis of ARCP circuit operation is presented to determine the requirements for achieving ZVS in the main switches of a wireless electric vehicle charging system. Based on this analysis, a design algorithm is developed to optimize the design of the ZVS assisting circuit components. The designed ARCP achieves soft switching of the MOSFETs in the primary inverter of an 85 kHz, 10 kW series-series compensated, stationary wireless power transfer system.

Saha, Tarak↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

Valuing Demand Flexibility During a Grid Disturbance: A Granular Approach to Resilience Valuation

As research continues to investigate how demand flexibility can aid in power system resilience so does the need for an approach to determine the value of resilience. This work utilizes visual modeling principles to model the value exchanges that take place within the system. These models can be used in analysis design as the foundation of a valuation analysis for each participant in the system. Utilizing a consistent approach for valuation will allow for different approaches in improving system resilience to be compared against each other in terms of economic outcomes of participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Elastic Solutions to 2D Plane Strain Problems: Nonlinear Contact and Settlement Analysis for Shallow Foundations

The classical Neumann boundary value problem of an isotropic, homogeneous elastic half-plane under plane strain conditions is readdressed as the limiting case of the fully three-dimensional problem. Analytical solutions of the stress and strain tensors are obtained by taking the limit from known three-dimensional solutions. It is shown that the displacement fields for the plane strain problem are not well defined. A small number of simple expressions are developed, which provide a general solution for linearly-varying traction over arbitrary regions on the boundary. A simple, efficient, and rapidly convergent algorithm is developed which uses these solutions as analytic elements and provides a solution approach to the general boundary value problem. The method is verified against known solutions for Hertzian contact between parallel cylinders. Two numerical examples are presented for the analysis of shallow foundation systems. In the first, the boundary conditions are informed by analytical elastoplastic calculations and a strain influence analysis is performed and compared with the Schmertmann method. Subsequently, empirical laboratory contact traction distributions measured by Bauer et al., in both the normal and tangential directions are employed as boundary conditions for an analysis of the underlying stress field.

42 ENGINEERING↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Specimen Size Artifacts Associated with a Glovebox Deployable Laser Flash Diffusivity Measurement System

To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Memory forensic analysis of a programmable logic controller in industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLCs) are used to automate physical processes such as nuclear plants and power grid stations, and are often subject to cyber attacks. As in conventional IT domain, the memory analysis of the PLCs can help answer important forensic questions about the attack, such as the presence of malicious firmware, injection of modified control logic (the program running on the PLC), and manipulation of I/O devices (e.g., sensors and actuators). Unlike conventional IT domain, PLCs have heterogeneous hardware architecture, proprietary firmware and control software, making it challenging to employ a unified framework for their memory forensics. For merely extracting artifacts of forensic importance, reverse-engineering the firmware is a tedious task, and the effort needs to be repeated for every PLC model. As a community, a step-wise approach to tackle this challenge is to analyze the memory of specific PLCs, and subsequently find a generic framework applicable to all PLCs. Our work is a step forward in this direction. By following a methodology that focuses on the functional layer of PLCs instead of reverse engineering the firmware, we analyze the digital forensic artifacts available in a common PLC, Allen-Bradley ControlLogix 1756-L61. Before diving into the memory dump, we analyze the PLC control software to create a list of important artifacts that are sure to exist in the PLC memory dump. The approach employs a setup where PLC control software RSLogix-5000 is connected to the PLC, and the memory dump can be obtained as and when needed. We create test cases that sequentially highlight each category of artifacts, followed by an examination of the resultant impact on memory. After attaining the listed artifacts, we employ conventional string and known data searches to extract interesting information present in this PLC's memory. The memory analysis profile, presented as a Python library and shared with the community, can help a forensic investigator to readily extract forensic artifacts from the same model's controller. The adopted approach may help researchers in creating memory profile of other PLCs, and ultimately formulating a generic PLC memory analysis framework.

Rais, Muhammad Haris↗

A warm super-Neptune around the G-dwarf star TOI-1710 revealed with TESS, SOPHIE, and HARPS-N

We report the discovery and characterization of the transiting extrasolar planet TOI-1710 b. It was first identified as a promising candidate by the Transiting Exoplanet Survey Satellite. Its planetary nature was then established with SOPHIE and HARPS-N spectroscopic observations via the radial-velocity method. The stellar parameters for the host star are derived from the spectra and a joint Markov chain Monte-Carlo adjustment of the spectral energy distribution and evolutionary tracks of TOI-1710. A joint MCMC analysis of the TESS light curve and the radial-velocity evolution allows us to determine the planetary system properties. From our analysis, TOI 1710 b is found to be a massive warm super-Neptune (M p = 28.3 ± 4.7 M ⊕ and R p = 5.34 ± 0.11 R ⊕ ) orbiting a G5V dwarf star (T eff = 5665 ± 55 K) on a nearly circular 24.3-day orbit (e = 0.16 ± 0.08). The orbital period of this planet is close to the estimated rotation period of its host star P rot = 22.5 ± 2.0 days and it has a low Keplerian semi-amplitude K = 6.4 ± 1.0 m s -1 ; we thus performed additional analyses to show the robustness of the retrieved planetary parameters. With a low bulk density of 1.03 ± 0.23 g cm -3 and orbiting a bright host star (J = 8.3, V = 9.6), TOI-1710 b is one of the best targets in this mass-radius range (near the Neptunian desert) for atmospheric characterization via transmission spectroscopy, a key measurement in constraining planet formation and evolutionary models of sub-Jovian planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic probabilistic risk assessment for electric grid cybersecurity

Electric grid cybersecurity risk has become a significant concern of industries and governments. This paper proposes a dynamic probabilistic risk assessment method for electric grid cybersecurity risk analysis. The proposed method helps reduce the reliance on expert judgment, capture a broad range of components and system dynamics, and model the interactions between various contributing entities (e.g., attacker, operator). In addition, the scenarios with multiple events, such as the occurrence of both cyberattacks and failures of physical components, the occurrence of both cyberattacks and operators’ (in)correct reactions, are considered and analyzed. Further, for each cyberattack scenario, Monte Carlo simulations are used to obtain possible sequences of the system's evolution under study and then derive risk estimates. As an application of the proposed method, the risk assessment method serves as the basis of risk-informed defense resource allocation to improve electric grid cybersecurity. The proposed method is verified using the IEEE 14-bus system by evaluating different security resource allocations for selected cyberattack scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗