Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Supercritical Carbon Dioxide (SCO2) Indirect Power Cycles Incorporating Fossil-Fuel Heat Sources

2014 Pittsburgh Coal Conference Presentation on indirect supercritical CO2 Cycles with the following sections: - Introduction - sCO2 Recompression Brayton Cycle - Screening of Fossil-based Heat Sources - Potential Benefits for Coal-Based Indirect sCO2 Cycles Conclusions include that (1) potential for significant efficiency gains over conventional steam cycles depending on the configuration and temperature; (2) applicable to multiple coal-based platforms; (3) costs currently uncertain; and, (4) coal-based systems have a potential for a 5-15% reduction in COE under certain assumptions.

Generic heat source↗

Design and experimental study of a secondary hohlraum radiation source with laser focal spots blocked

A design of secondary hohlraum radiation source with laser focal spots blocked is introduced. The hard x-ray radiation such as the gold M-band emission and hot electrons from the coronal plasma were designed to be shielded using a cylindrical shield. Three-dimensional view factor analysis was carried out to optimize the shield structure to achieve higher radiation temperature. An experiment was performed at Shenguang III prototype laser facility to verify the design. Velocity Interferometer System for Any Reflector was used to measure the shock wave speed in a three-stepped Al sample driven by this radiation source and the peak radiation temperature of the radiation source was estimated to be about 90 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TunIO: An AI-powered Framework for Optimizing HPC I/O

I/O operations are a known performance bottleneck of HPC applications. To achieve good performance, users often employ an iterative multistage tuning process to find an optimal I/O stack configuration. However, an I/O stack contains multiple layers, such as high-level I/O libraries, I/O middleware, and parallel file systems, and each layer has many parameters. These parameters and layers are entangled and influenced by each other. The tuning process is time-consuming and complex. In this work, we present TunIO, an AI-powered I/O tuning framework that implements several techniques to balance the tuning cost and performance gain, including tuning the high-impact parameters first. Furthermore, TunIO analyzes the application source code to extract its I/O kernel while retaining all statements necessary to perform I/O. It utilizes a smart selection of high-impact configuration parameters of the given tuning objective. Finally, it uses a novel Reinforcement Learning (RL)-driven early stopping mechanism to balance the cost and performance gain. Experimental results show that TunIO leads to a reduction of up to ≈73% in tuning time while achieving the same performance gain when compared to H5Tuner. It achieves a significant performance gain/cost of 208.4 MBps/min (I/O bandwidth for each minute spent in tuning) over existing approaches under our testing.

Rajesh, Neeraj↗

Dispersed Fringe Sensing Analysis - DFSA

Dispersed Fringe Sensing (DFS) is a technique for measuring and phasing segmented telescope mirrors using a dispersed broadband light image. DFS is capable of breaking the monochromatic light ambiguity, measuring absolute piston errors between segments of large segmented primary mirrors to tens of nanometers accuracy over a range of 100 micrometers or more. The DFSA software tool analyzes DFS images to extract DFS encoded segment piston errors, which can be used to measure piston distances between primary mirror segments of ground and space telescopes. This information is necessary to control mirror segments to establish a smooth, continuous primary figure needed to achieve high optical quality. The DFSA tool is versatile, allowing precise piston measurements from a variety of different optical configurations. DFSA technology may be used for measuring wavefront pistons from sub-apertures defined by adjacent segments (such as Keck Telescope), or from separated sub-apertures used for testing large optical systems (such as sub-aperture wavefront testing for large primary mirrors using auto-collimating flats). An experimental demonstration of the coarse-phasing technology with verification of DFSA was performed at the Keck Telescope. DFSA includes image processing, wavelength and source spectral calibration, fringe extraction line determination, dispersed fringe analysis, and wavefront piston sign determination. The code is robust against internal optical system aberrations and against spectral variations of the source. In addition to the DFSA tool, the software package contains a simple but sophisticated MATLAB model to generate dispersed fringe images of optical system configurations in order to quickly estimate the coarse phasing performance given the optical and operational design requirements. Combining MATLAB (a high-level language and interactive environment developed by MathWorks), MACOS (JPL s software package for Modeling and Analysis for Controlled Optical Systems), and DFSA provides a unique optical development, modeling and analysis package to study current and future approaches to coarse phasing controlled segmented optical systems.

Sigrist, Norbert↗

A STUDY OF FUNDAMENTAL LIMITATIONS TO STATISTICAL DETECTION OF REDSHIFTED H I FROM THE EPOCH OF REIONIZATION

In this paper, we explore for the first time the relative magnitudes of three fundamental sources of uncertainty, namely, foreground contamination, thermal noise, and sample variance, in detecting the H I power spectrum from the epoch of reionization (EoR). We derive limits on the sensitivity of a Fourier synthesis telescope to detect EoR based on its array configuration and a statistical representation of images made by the instrument. We use the Murchison Widefield Array (MWA) configuration for our studies. Using a unified framework for estimating signal and noise components in the H I power spectrum, we derive an expression for and estimate the contamination from extragalactic point-like sources in three-dimensional k-space. Sensitivity for EoR H I power spectrum detection is estimated for different observing modes with MWA. With 1000 hr of observing on a single field using the 128 tile MWA, EoR detection is feasible (S/N >1 for k ∼< 0.8 Mpc{sup –1}). Bandpass shaping and refinements to the EoR window are found to be effective in containing foreground contamination, which makes the instrument tolerant to imaging errors. We find that for a given observing time, observing many independent fields of view does not offer an advantage over a single field observation when thermal noise dominates over other uncertainties in the derived power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

A dense plasma ultraviolet source

The intense ultraviolet emission from the NASA Hypocycloidal-Pinch (HCP) plasma is investigated. The HCP consists of three disk electrodes whose cross section has a configuration similar to the cross section of a Mather-type plasma focus. Plasma foci were produced in deuterium, helium, xenon, and krypton gases in order to compare their emission characteristics. Time-integrated spectra in the wavelength range from 200 nm to 350 nm and temporal variations of the uv emission were obtained with a uv spectrometer and a photomultiplier system. Modifications to enhance uv emission in the iodine-laser pump band (250 to 290 nm) and preliminary results produced by these modifications are presented. Finally, the advantages of the HCP as a uv over use of conventional xenon lamps with respect to power output limit, spectral range, and lifetime are discussed.

Lee, J. H.↗

Compact, variable, moving sources observed on the sun at 2 centimeters wavelength

The Very Large Array (VLA) was used to observe the active region AT 4508 in the C-configuration between 1530 and 2330 UT on June 4, 1984. The position of this region was N06 E57 at 1300 UT on this day. Followup observations were made between 1500 and 2300 UT on January 17, 1986 in the D-configuration. Observations were compared with Mt. Wilson magnetograms. Results are discussed.

Lang, Kenneth R.↗

High-energy X-ray source and detector for wellbore inspection

A system, method, and apparatus for wellbore inspection comprise an electron accelerator to generate X-rays, a rotating collimator assembly configured to produce a cone of X-rays, and at least one detector assembly configured to collect backscattered X-rays. A position assembly can be provided to move the electron accelerator, rotating collimator assembly, and detector through a wellbore. A computer system is configured to receive data from the detector and generate an image of the wellbore.

Kroc, Thomas K.↗

Recovery and calibration of legacy analog data from the Leo Brady Seismic Network for the Source Physics Experiment

The Leo Brady Seismic Network (LBSN) was established in 1960 by Sandia National Laboratories for monitoring underground nuclear tests (UGTs) at the Nevada Test Site— renamed in 2010 to the Nevada National Security Site (NNSS). The LBSN has been in various configurations throughout its existence, but it has been generally comprised of four to six stations at regional distances from the NNSS with evenly spaced azimuthal coverage. Between 1962 and the early 1980s, the LBSN—and a sister network operated by Lawrence Livermore National Laboratory—were the most comprehensive U.S. source of regional seismic data of UGTs. During the pre-digital era, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to the NTS and recorded in analog on hi-fi 8-track AMPEX tapes. These tapes have been stored in temperature-stable buildings or bunkers on the NNSS and Kirtland Air Force Base in Albuquerque, NM for decades and contain the sole record of this irreplaceable data from the analog era; full waveforms of UGTs during this time were never routinely converted to digital form. We have been developing a process over the past few years to recover and calibrate data from these tapes, converting them from FM audio to digital waveforms in ground motion units. The calibration of legacy data from the LBSN is still ongoing. To date, we have digitized tapes from 592 separate UGTs. As a proof-of-concept, we calibrated data from the BOXCAR event.

58 GEOSCIENCES↗

Aerodynamic Measurements of a Gulfstream Aircraft Model With and Without Noise Reduction Concepts

Steady and unsteady aerodynamic measurements of a high-fidelity, semi-span 18% scale Gulfstream aircraft model are presented. The aerodynamic data were collected concurrently with acoustic measurements as part of a larger aeroacoustic study targeting airframe noise associated with main landing gear/flap components, gear-flap interaction noise, and the viability of related noise mitigation technologies. The aeroacoustic tests were conducted in the NASA Langley Research Center 14- by 22-Foot Subsonic Wind Tunnel with the facility in the acoustically treated open-wall (jet) mode. Most of the measurements were obtained with the model in landing configuration with the flap deflected at 39º and the main landing gear on and off. Data were acquired at Mach numbers of 0.16, 0.20, and 0.24. Global forces (lift and drag) and extensive steady and unsteady surface pressure measurements were obtained. Comparison of the present results with those acquired during a previous test shows a significant reduction in the lift experienced by the model. The underlying cause was traced to the likely presence of a much thicker boundary layer on the tunnel floor, which was acoustically treated for the present test. The steady and unsteady pressure fields on the flap, particularly in the regions of predominant noise sources such as the inboard and outboard tips, remained unaffected. It is shown that the changes in lift and drag coefficients for model configurations fitted with gear/flap noise abatement technologies fall within the repeatability of the baseline configuration. Therefore, the noise abatement technologies evaluated in this experiment have no detrimental impact on the aerodynamic performance of the aircraft model.

Neuhart, Dan H.↗

Dependency of optical/UV parameters on X-ray spectral index in AGNs

The study of Active Galactic Nuclei (AGNs) is vital in order to understand their respective nuclei bounded activity primarily triggered by the accretion disk and the associated corona. The hard X-ray emission characterised by the spectral index Γ emitted by these sources in 2-10 keV band ionizes the nearby physical features like disk, BLR, NLR and provides a radiative configuration. However, based on previous studies, there is degeneracy in the evolution of Γ across the redshift, wherein few studies display a systematic trend in the evolution and others rule out the systematic variation. Here, in the present work, we study the evolution of Γ across the redshift for a very large sample and perform further studies on the variation of Γ with optical parameters using SDSS data viz. H β & Mg II and their luminosities. Based on analysis we find that there is no change in Γ across the redshift and it does not show any correlation with the optical parameters. This strongly suggests that the Γ is influenced by the soft excess and/or reflection component and is affecting the disk and BLR region at the same strength across the redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Channeling analysis in studying ion irradiation damage in materials containing various types of defects

We present that ion channeling is a powerful quantitative technique for studying ion-irradiation induced defect evolution in single crystalline materials. An iterative procedure to determine dechanneling yields has been developed for decades, serving as a major method for analyzing experimental channeling data. The applicability of such procedure is, however, generally limited to the crystalline damage with only point defects and local amorphous domains. For the other cases, such as irradiated metals, the assumption of direct-backscattering free has usually been made. In the present study, Ni, TiAl, MgO, and SrTiO 3 single crystals are selected as four model materials, representing metals, intermetallic alloys, and ceramic compounds with different defect evolution processes under irradiation, to investigate the fidelity of applying dechanneling analysis on various types of defects. The pure dechanneling assumption is shown oversimplified in Ni irradiated with low fluence self-ions and may result in error on the derived damage profile. Moreover, the iterative procedure of dechanneling analysis is shown valid for more general situations than the randomly distributed atoms, including those not exhibiting a peak in channeling spectra. The disappearance of damage peak in channeling spectra is attributed to the combined effects of small (but non-zero) scattering factor, long-range damage effects, and non-ignorable damage level in pristine crystals. Furthermore, the ratio of direct backscattering to dechanneling areas provides information on defect configurations in the materials containing a well-defined damage peak in channeling spectra. Finally, the contribution from dechanneling sources increases from SrTiO 3 , TiAl, to MgO, according to the derived scattering and dechanneling factors.

36 MATERIALS SCIENCE↗

Laser Ablation Positive-Ion AMS of Neutron Activated Actinides

At Argonne we have enhanced the AMS capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) to attempt to minimize crosstalk between samples and to quickly move from one (M/Q) setting to another in order to make measurements on a large number of samples provided by the MANTRA (Measurement of Actinide Neutron Transmutation Rates by Accelerator mass spectrometry) project. Those improvements include the use of a picosecond laser to ablate actinide material into the source, a new 20- sample holder that can switch samples within 1-2 minutes, and a number of accelerator configuration improvements that allow quick and precise switching between species. In principle, AMS can provide production yields of actinide isotopes produced during the irradiation period at a sensitivity exceeding other mass spectrometry techniques. A total of 27 irradiated samples of a variety of actinides have been provided for measurement. We discuss our experience with these facility improvements and how well we have met our performance goals. In addition, we present preliminary results on a number of the irradiated actinide samples with this approach and compare those results to Multi- Collector ICPMS measurements.

Pardo, R. C.↗

Greenhouse gas emissions from landfill leachate treatment plants: A comparison of young and aged landfill

Highlights: • Young and aged leachate works accounted for 89.1% and 10.9% of 33.35 Gg CO{sub 2} yr{sup −1}. • Fresh leachate owned extremely low ORP and high organic matter content. • Strong CH{sub 4} emissions occurred in the fresh leachate ponds, but small in the aged. • N{sub 2}O emissions became dominant in the treatment units of both systems. • 8.45–11.9% of nitrogen was removed as the form of N{sub 2}O under steady-state. - Abstract: With limited assessment, leachate treatment of a specified landfill is considered to be a significant source of greenhouse gas (GHG) emissions. In our study, the cumulative GHG emitted from the storage ponds and process configurations that manage fresh or aged landfill leachate were investigated. Our results showed that strong CH{sub 4} emissions were observed from the fresh leachate storage pond, with the fluxes values (2219–26,489 mg C m{sup −2} h{sup −1}) extremely higher than those of N{sub 2}O (0.028–0.41 mg N m{sup −2} h{sup −1}). In contrast, the emission values for both CH{sub 4} and N{sub 2}O were low for the aged leachate tank. N{sub 2}O emissions became dominant once the leachate entered the treatment plants of both systems, accounting for 8–12% of the removal of N-species gases. Per capita, the N{sub 2}O emission based on both leachate treatment systems was estimated to be 7.99 g N{sub 2}O–N capita{sup −1} yr{sup −1}. An increase of 80% in N{sub 2}O emissions was observed when the bioreactor pH decreased by approximately 1 pH unit. The vast majority of carbon was removed in the form of CO{sub 2}, with a small portion as CH{sub 4} (<0.3%) during both treatment processes. The cumulative GHG emissions for fresh leachate storage ponds, fresh leachate treatment system and aged leachate treatment system were 19.10, 10.62 and 3.63 Gg CO{sub 2} eq yr{sup −1}, respectively, for a total that could be transformed to 9.09 kg CO{sub 2} eq capita{sup −1} yr{sup −1}.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytic model for neutral penetration and plasma fueling

Neutral atoms recycled from wall interaction interact with confined plasma, thereby refuelling it, most strongly in the region closest to the wall. This occurs near the X-point in diverted configurations, or else near the wall itself in limited configurations. A progression of analytic models is developed for neutral density in the vicinity of a planar or linear source in an ionising domain. First-principles neutral transport simulations with DEGAS2 are used throughout to test the validity and limits of the model when using equivalent sources. The model is further generalised for strong plasma gradients or the inclusion of charge exchange. An important part of the problem of neutral fuelling from recycling is thereby isolated and solved with a closed-form analytic model. A key finding is that charge exchange with the confined plasma can be significantly simplified with a reasonable sacrifice of accuracy by treating it as a loss. The several assumptions inherent to the model (and the simulations with which it is compared) can be adapted according to the particular behaviour of neutrals in the divertor and the manner in which they cross the separatrix.

fusion plasma↗

Hybrid Grid-Renewable Strategies for Green Steel Production under Electricity Market Uncertainty

Volatility in grid spot prices is expected to rise with climate change-driven demand pressures and the intermittency of renewable generation. This volatility poses financial risks for green hydrogen-based steel production. The Direct Reduced Iron− Electric Arc Furnace (H 2 -DRI-EAF) is a promising pathway to decarbonize steel, which accounts for ∼8% of global GHG emissions. This study assesses how increased grid spot price volatility influences the optimal sizing and operation of H2-DRIEAF plants under three operational scenarios: grid-connected, fully behind-the-meter (islanded), and mixed-mode (semi-islanded). Our analysis identifies the semi-islanded configuration as the most cost-effective solution, achieving a Levelized Cost of Steel (LCOS) 10−35% lower than sourcing energy solely from the grid. Modeling also shows hydrogen storage or selective electricity purchases at high prices (>$1000/MWh) generally outperform battery storage, except under extreme volatility. Additionally, the study explores cost reduction strategies to strengthen the economic viability and sustainability of green steel production.

Batteries↗