Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Water Security Toolkit

The Water Security Toolkit (WST) provides software for modeling and analyzing water distribution systems to minimize the potential impact of contamination incidents. WST wraps capabilities for contaminant transport, impact assessment, and sensor network design with response action plans, including source identification, rerouting, and decontamination, to provide a range of water security planning and real-time applications.

Source record↗

Hydrogen Wide Area Monitoring of LH2 Releases at HSE for the PRESHLY Project

The characterization of liquid hydrogen (LH2) releases has been identified as an international research priority to expand the safe use of hydrogen as an energy carrier. Empirical field measurements such as those afforded by Hydrogen Wide Area Monitoring (HyWAM) can elucidate the behavior of LH2 releases, which can then be used to support and validate dispersion models. HyWAM can be defined as the quantitative three-dimensional spatial and temporal profiling of planned or unintentional hydrogen releases. The NREL Sensor Laboratory developed a HyWAM based upon a distributed array of hydrogen Sensors. The NREL Sensor Laboratory and Health and Safety Executive (HSE) formally committed to collaborate on profiling GH2 and LH2 releases, which allowed for the integration of the NREL HyWAM into the HSE LH2 release behavior investigation supported by the FCH JU Prenormative Research for the Safe Use of Liquid Hydrogen (PRESLHY) program. A HyWAM system consisting of 32 hydrogen measurement points and co-located temperature sensors were distributed downstream of the LH2 release apparatus developed by HSE. In addition, there were proximal wind and weather monitors. In a separate presentation at this conference "HSE SD Experimental Summary for the Characterisation, Dispersion and Electrostatic Hazards of LH2 for the PRESLHY Project" HSE researchers summarize the experimental apparatus and experimental protocols utilized in the HSE LH2 releases that were performed under the auspices of PRESLHY. To supplement the HSE presentation, this presentation will focus on the spatial and temporal behavior LH2 releases as measured by the NREL HyWAM. Correlations to ambient conditions, such as wind speed and direction, plume temperature and hydrogen concentrations will be discussed in addition to the design and performance of the NREL HyWAM, and its potential for improving hydrogen facility safety.

HYDROGEN↗

TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

60 APPLIED LIFE SCIENCES↗

Modeling of Magnetic Properties of Magnetorheological Elastomers Using JA Hysteresis Model

Magnetorheological elastomers (MREs) are composite materials that consist of magnetically permeable particles in a nonmagnetic polymeric matrix. Under the influence of an external magnetic field, a reversible deformation change occurs in the mechanical properties of these materials. Due to their coupled magnetomechanical response, these materials have been found suitable for a range of applications including tunable vibration absorbers, sensors, and actuators. Notably, improvement of such devices are prerequisites to efficient energy conversion systems, hence the need to understand further the MRE technology. The Jiles-Atherton (JA) theory takes into consideration the magneto-coupling experienced by effective domains in a magnetic material. Algorithm based on the theory yields five model parameters; saturation magnetization (M s ), domain density (a), domain coupling (α), loss coefficient (k), and reversibility (c). Using JA theory, model parameters were calculated and linked to the physical attributes of Fe powder and isotropic MRE. The results show that the calculated Ms for the MRE is reasonably related to that of the Fe powder by a factor of the particle's volume fraction used in the MRE. Further, the calculated k, a, and α provided support for the reduced pinning factor, domain density, and increased domain coupling in the MRE due to the changes in the domain structure between the two materials. From the calculated JA parameters, finite-element modeling (FEM) of the MRE hysteresis loop was performed. The analysis showed that the modeled magnetic properties including coercivity, remanence, and coordinates of the hysteresis loop tip vary with geometric position.

42 ENGINEERING↗

(U) Physics Validation of the RMI-Based Ejecta Source Model Implementation in FLAG: L2 Milestone #6035 Report

The Los Alamos Physics and Engineering Models (PEM) program has developed a model for Richtmyer-Meshkov instability (RMI) based ejecta production from shock-melted surfaces, along with a prescription for a self-similar velocity distribution (SSVD) of the resulting ejecta particles. We have undertaken an effort to validate this source model using data from explosively driven tin coupon experiments. The model’s current formulation lacks a crucial piece of physics: a method for determining the duration of the ejecta production interval. Without a mechanism for terminating ejecta production, the model is not predictive. Furthermore, when the production interval is hand-tuned to match time-integrated mass data, the predicted time-dependent mass accumulation on a downstream sensor rises too sharply at early times and too slowly at late times because the SSVD overestimates the amount of mass stored in the fastest particles and underestimates the mass stored in the slowest particles. The functional form of the resulting m(t) is inconsistent with the available time-dependent data; numerical simulations and analytic studies agree on this point. Simulated mass tallies are highly sensitive to radial expansion of the ejecta cloud. It is not clear if the same effect is present in the experimental data but if so, depending on the degree, this may challenge the model’s compatibility with tin coupon data. The current implementation of the model in FLAG is sensitive to the detailed interaction between kinematics (hydrodynamic methods) and thermodynamics (material models); this sensitivity prohibits certain physics modeling choices. The appendices contain an extensive analytic study of piezoelectric ejecta mass measurements, along with test problems, excerpted from a longer work (LA-UR-17-21218).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a dissolved oxygen sensor made of plastic optical fiber coated with ruthenium-incorporated solgel

A dissolved oxygen sensor made of plastic optical fiber as the substrate and dichlorotris (1, 10-phenanthroline) ruthenium as a fluorescence indicator is studied. Oxygen quenching characteristics of both intensity and phase were measured; the obtained characteristics showed deviation from the linear relation described by the Stern-Volmer equation. A two-layer model is proposed to explain the deviation, and main parameters can be deduced with the model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Empirical profiling of cold hydrogen plumes formed from venting of LH 2 storage vessels

Liquid hydrogen (LH 2 ) storage is viewed as a viable approach to assure sufficient hydrogen capacity at commercial fuelling stations. Presently, LH 2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH 2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH 2 delivery and site transfer process. The behavior of cold hydrogen plumes has not been well characterized because of the sparsity of empirical field data, which can lead to overly conservative safety requirements. Committee members of the National Fire Protection Association (NFPA) Standard 2 [1] formed the Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and computational fluid dynamics modellers, has identified the lack of understanding of hydrogen dispersion during LH 2 venting of storage vessels as a critical gap for establishing safety distances at LH 2 facilities, especially commercial hydrogen fuelling stations. To address this need, the National Renewable Energy Laboratory Sensor Laboratory, in collaboration with the NFPA Hydrogen Storage Task Group, developed a prototype Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH 2 storage tank venting. The prototype analyzer was field deployed during an actual LH 2 venting process. Critical findings included: hydrogen above the lower flammable limit (LFL) was detected as much as 2 m lower than the release point, which is not predicted by existing models; personal monitors detected hydrogen at ground level, although at levels below the LFL; a small but inconsistent correlation was found between oxygen depletion and the hydrogen concentration; a negligible to non-existent correlation was found between in-situ temperature measurements and the hydrogen concentration. The prototype analyzer is being upgraded for enhanced metrological capabilities, including improved real-time spatial and temporal profiling of hydrogen plumes and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behavior under different wind, humidity, and temperature conditions. The data will be shared with the Hydrogen Storage Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

08 HYDROGEN↗

A Spectral Element Approach for Modeling of Wave-Based Structural Health Monitoring Systems

During the last decades, guided waves have shown great potential for Structural Health Monitoring (SHM) applications. These waves can be excited and sensed by piezoelectric elements that can be permanently attached onto a structure offering online monitoring capability. As the setup of wave based SHM systems may be very difficult and time consuming there is a growing demand for efficient simulation tools providing the opportunity to design wave based SHM systems in a virtual environment. As usually high frequency waves are used, the associated short wavelength leads to the necessity of a very dense mesh, which makes conventional finite elements not well suited for this purpose. Therefore a flat shell spectral element approach is presented in this contribution. By including electromechanical coupling an SHM system can be simulated entirely from actuator voltage to sensor voltage. The focus of this contribution is the analysis of the effect of delaminations on propagating waves. A forward increment Lagrange multiplier method is used to simulate contact within the delaminated area. A model validation is performed using measured data of an anisotropic CFRP-plate.

36 MATERIALS SCIENCE↗

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insights from modeling and observational evaluation of a precipitating continental cumulus event observed during the MC3E field campaign

A case of shallow cumulus and precipitating cumulus congestus sampled at the Atmospheric Radiation Measurement (ARM) Program Southern Great Plains (SGP) supersite is analyzed using a multi-sensor observational approach and numerical simulation. Observations from a new radar suite surrounding the facility are used to characterize the evolving statistical behavior of the precipitating cloud system. This is accomplished using distributions of different measures of cloud geometry and precipitation properties. Large-eddy simulation (LES) with size-resolved (bin) microphysics is employed to determine the forcings most important in producing the salient aspects of the cloud system captured in the radar observations. Our emphasis is on assessing the importance of time-varying vs. steady-state large-scale forcing on the model's ability to reproduce the evolutionary behavior of the cloud system. Additional consideration is given to how the characteristic spatial scale and homogeneity of the forcing imposed on the simulation influences the evolution of cloud system properties. Results indicate that several new scanning radar estimates such as distributions of cloud top are useful to differentiate the value of time-varying (or at least temporally well-matched) forcing on LES solution fidelity.

54 ENVIRONMENTAL SCIENCES↗

Response Relationship Between Juvenile Salmon and an Autonomous Sensor in Turbulent Flows

Juvenile fall chinook salmon (Oncorhynchus tshawythscha) and an autonomous sensor device (Sensor Fish) were exposed to turbulent shear flows in order to determine how hydraulic conditions effected fish injury response. Studies were designed to establish correlation metrics between Sensor Fish device measurements and live fish injuries by conducting concurrent releases in a range of turbulent shear flows. Comparisons were made for two exposure scenarios. In the fast-fish-to-slow-water scenario, test fish were carried by the fast-moving water of a submerged turbulent jet and exposed into the standing water of a flume. In the slow-fish-to-fast-water scenario, test fish were introduced into a turbulent jet from standing water through an introduction tube placed just outside the edge of the jet. Motion-tracking analysis was performed on high-speed, high-resolution digital videos of all the releases at water jet velocities ranging from 3 to 22.9 m · s -1 . Velocities of the Sensor Fish were very similar to those of live fish, but maximum accelerations of live fish were larger than those by Sensor Fish for all the nozzle velocities of both cenarios. A 10% probability of major injury threshold was found to occur at sensor fish accelerations of 513 and 260 (m · s -2 ) for the fast-fish-to-slow-water and slow-fish-to-fast-water scenarios, respectively. The findings provide a linkage between laboratory experiments of fish injury, field survival studies, and numerical modeling.

13 HYDRO ENERGY↗

Printable organic thin film transistors for glucose detection incorporating inkjet-printing of the enzyme recognition element

The effect of device architecture upon the response of printable enzymatic glucose sensors based on poly(3-hexythiophene) (P3HT) organic thin film transistors is presented. The change in drain current is used as the basis for glucose detection and we show that significant improvements in drain current response time can be achieved by modifying the design of the sensor structure. In particular, we show that eliminating the dielectric layer and reducing the thickness of the active layer reduce the device response time considerably. The results are in good agreement with a diffusion based model of device operation, where an initial rapid dedoping process is followed by a slower doping of the P3HT layer from protons that are enzymatically generated by glucose oxidase (GOX) at the Nafion gate electrode. The fitted diffusion data are consistent with a P3HT doping region that is close to the source-drain electrodes rather than located at the P3HT:[Nafion:GOX] interface. Finally, we demonstrate that further improvements in sensor structure and morphology can be achieved by inkjet-printing the GOX layer, offering a pathway to low-cost printed biosensors for the detection of glucose in saliva.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonequilibrium spin transport through a diluted magnetic semiconductor quantum dot system with noncollinear magnetization

The spin-dependent transport through a diluted magnetic semiconductor quantum dot (QD) which is coupled via magnetic tunnel junctions to two ferromagnetic leads is studied theoretically. A noncollinear system is considered, where the QD is magnetized at an arbitrary angle with respect to the leads' magnetization. The tunneling current is calculated in the coherent regime via the Keldysh nonequilibrium Green's function (NEGF) formalism, incorporating the electron-electron interaction in the QD. We provide the first analytical solution for the Green's function of the noncollinear DMS quantum dot system, solved via the equation of motion method under Hartree-Fock approximation. The transport characteristics (charge and spin currents, and tunnel magnetoresistance (TMR)) are evaluated for different voltage regimes. The interplay between spin-dependent tunneling and single-charge effects results in three distinct voltage regimes in the spin and charge current characteristics. The voltage range in which the QD is singly occupied corresponds to the maximum spin current and greatest sensitivity of the spin current to the QD magnetization orientation. The QD device also shows transport features suitable for sensor applications, i.e., a large charge current coupled with a high TMR ratio. - Highlights: Black-Right-Pointing-Pointer The spin polarized transport through a diluted magnetic quantum dot is studied. Black-Right-Pointing-Pointer The model is based on the Green's function and the equation of motion method. Black-Right-Pointing-Pointer The charge and spin currents and tunnel magnetoresistance (TMR) are investigated. Black-Right-Pointing-Pointer The system is suitable for current-induced spin-transfer torque application. Black-Right-Pointing-Pointer A large tunneling current and a high TMR are possible for sensor application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Insights from application of a hierarchical spatio-temporal model to an intensive urban black carbon monitoring dataset

Existing regulatory pollutant monitoring networks rely on a small number of centrally located measurement sites that are purposefully sited away from major emission sources. While informative of general air quality trends regionally, these networks often do not fully capture the local variability of air pollution exposure within a community. Recent technological advancements have reduced the cost of sensors, allowing air quality monitoring campaigns with high spatial resolution. The 100×100 black carbon (BC) monitoring network deployed 100 low-cost BC sensors across the 15 km 2 West Oakland, CA community for 100 days in the summer of 2017, producing a nearly continuous site-specific time series of BC concentrations which we aggregated to one-hour averages. Leveraging this dataset, we employed a hierarchical spatio-temporal model to accurately predict local spatio-temporal concentration patterns throughout West Oakland, at locations without monitors (average cross-validated hourly temporal R 2 =0.60). Using our model, we identified spatially varying temporal pollution patterns associated with small-scale geographic features and proximity to local sources. In a sub-sampling analysis, here we demonstrated that fine scale predictions of nearly comparable accuracy can be obtained with our modeling approach by using ~30% of the 100×100 BC network supplemented by a shorter-term high-density campaign.

54 ENVIRONMENTAL SCIENCES↗

Toward a more realistic representation of surface albedo in NASA CERES-derived surface radiative fluxes

Accurate multidecadal radiative flux records are vital to understand Arctic amplification and constrain climate model uncertainties. Uncertainty in the NASA Clouds and the Earth’s Radiant Energy System (CERES)-derived irradiances is larger over sea ice than any other surface type and comes from several sources. The year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic provides a rare opportunity to explore uncertainty in CERES-derived radiative fluxes. First, a systematic and statistically robust assessment of surface shortwave and longwave fluxes was conducted using in situ measurements from MOSAiC flux stations. The CERES Synoptic 1degree (SYN1deg) product overestimates the downwelling shortwave flux by +11.40 Wm –2 and underestimates the upwelling shortwave flux by –15.70 Wm –2 and downwelling longwave fluxes by –12.58 Wm –2 at the surface during summer. In addition, large differences are found in the upwelling longwave flux when the surface approaches the melting point (approximately 0°C). The biases in downwelling shortwave and longwave fluxes suggest that the atmosphere represented in CERES is too optically thin. The large negative bias in upwelling shortwave flux can be attributed in large part to lower surface albedo (–0.15) in satellite footprint relative to surface sensors. Additionally, the results show that the spectral surface albedo used in SYN1deg overestimates albedo in visible and mid-infrared bands. A series of radiative transfer model perturbation experiments are performed to quantify the factors contributing to the differences. The CERES-MOSAiC broadband albedo differences (approximately 20 Wm –2 ) explain a larger portion of the upwelling shortwave flux difference than the spectral albedo shape differences (approximately 3 Wm –2 ). In addition, the differences between perturbation experiments using hourly and monthly MOSAiC surface albedo suggest that approximately 25% of the sea ice surface albedo variability is explained by factors not correlated with daily sea ice concentration variability. Biases in net shortwave and longwave flux can be reduced to less than half by adjusting both albedo and cloud inputs toward observed values. The results indicate that improvements in the surface albedo and cloud data would substantially reduce the uncertainty in the Arctic surface radiation budget derived from CERES data products.

54 ENVIRONMENTAL SCIENCES↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗