Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Monte Carlo sampling and correlation coefficients of critical experiments

We study the influence of calculation parameters on Monte-Carlo generated correlation coefficients of k{sub eff} values for a data set of critical experiments. The correlation coefficients can be used e.g. to reduce conservatism in bias estimations, but generally must be treated correctly if a data set includes correlations. We find that the actual value of the correlation coefficient for a given data set depends on the number of samples and the ratio of the sampling uncertainty to the Monte-Carlo uncertainty of the individual k{sub eff} calculation. We also discuss that the number of input parameters of the model to calculate the k{sub eff} values do not necessarily impact the convergence of the correlation coefficient with increasing sample number. However, we explain how varying the aforementioned parameters lead to different converged results for the correlation coefficients. The conclusion is that a correlation coefficient should not be discussed isolated but with the underlying uncertainties of both, the k{sub eff} estimation and the Monte Carlo sampling approach. The underlying modelling approach of the experimental data has to be described in detail. This should include a sensitivity analysis of the impact of input parameters on the k{sub eff} uncertainty with respect to the modelling approach.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mercury Speciation of Hanford 241-AP-107 Tank Waste Samples - 20384

The concentration of key mercury species in the Hanford tank waste has not been previously measured. Based on process knowledge, an estimated inventory of 2,100 kg of mercury is assumed and was distributed in varied amounts across 149 single-shell tanks (SSTs) and 28 double-shell tanks (DSTs). Limited analyses of individual SSTs and DSTs for total mercury were all below detection, yielding upper limits in concentration estimates based solely on instrument detection limits, resulting in an uncertain mercury inventory for Hanford tanks. Accurate and reliable chemical speciation and quantification is desired to anticipate, predict, and abate the mass movements of various mercury species through the Hanford waste processing flowsheet. Highly sensitive separation and quantification methods for total, elemental, and monomethyl mercury species, in tank waste, have been developed at the Pacific Northwest National Laboratory's (PNNL) Radiochemical Processing Laboratory (RPL). A non-radiological environmental method to quantify mercury species has been adapted for application to Hanford tank 241-AP-107 raw supernatant feed, filtered feed, and cesium-decontaminated samples. These samples represent feed inventory and pretreatment process effluents prior to immobilization by vitrification. This method separates and preconcentrates total, elemental, and monomethyl mercury onto selective solid substrates with little-to-no radioactive background. The solid samples can then be released from strict radiological control, allowing for analytical work to be conducted in low-level radiological facilities. Separation of mercury species was demonstrated at PNNL's RPL in Richland, Washington before transport and analytical quantification using cold vapor atomic fluorescence spectrometry (CVAFS) at PNNL's Marine Science Laboratory (MSL) in Sequim, Washington. Additional studies were conducted to assess the stability of monomethyl mercury in distilled matrices and preconcentrated onto the Carbotrap{sup R} solid substrate to assess sample degradation over time during transport. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XANES Identification of Plutonium Speciation in RFETS Samples

Using primarily X-ray absorption near edge spectroscopy (XANES) with standards run in tandem with samples, probable plutonium speciation was determined for 13 samples from contaminated soil, acid-splash or fire-deposition building interior surfaces, or asphalt pads from the Rocky Flats Environmental Technology Site (RFETS). Save for extreme oxidizing situations, all other samples were found to be of Pu(IV) speciation, supporting the supposition that such contamination is less likely to show mobility off site. EXAFS analysis conducted on two of the 13 samples supported the validity of the XANES features employed as determinants of the plutonium valence.

36 MATERIALS SCIENCE↗

X-Ray Absorption Near Edge Structure And Extended X-Ray Absorption Fine Structure Analysis of Standards And Biological Samples Containing Mixed Oxidation States of Chromium(III) And Chromium(VI)

For the first time a method has been developed for the extended X-ray absorption fine structure (EXAFS) data analyses of biological samples containing multiple oxidation states of chromium. In this study, the first shell coordination and interatomic distances based on the data analysis of known standards of potassium chromate (Cr(VI)) and chromium nitrate hexahydrate (Cr(III)) were investigated. The standards examined were mixtures of the following molar ratios of Cr(VI):Cr(III), 0:1, 0.25:0.75, 0.5:0.5, 0.75:0.25, and 1:0. It was determined from the calibration data that the fitting error associated with linear combination X-ray absorption near edge structure (LC-XANES) fittings was approximately {+-}10% of the total fitting. The peak height of the Cr(VI) pre-edge feature after normalization of the X-ray absorption (XAS) spectra was used to prepare a calibration curve. The EXAFS fittings of the standards were also investigated and fittings to lechuguilla biomass samples laden with different ratios of Cr(III) and Cr(VI) were performed as well. An excellent agreement between the XANES data and the data presented in the EXAFS spectra was observed. The EXFAS data also presented mean coordination numbers directly related to the ratios of the different chromium oxidation states in the sample. The chromium oxygen interactions had two different bond lengths at approximately 1.68 and 1.98 {angstrom} for the Cr(VI) and Cr(III) in the sample, respectively.

09 BIOMASS FUELS↗

Retrospective Reactor Dosimetry with Zirconium Alloy Samples

Retrospective measurements are routinely performed with stainless steel samples. Recent experiments have been successfully conducted using zirconium alloy samples, involving somewhat different neuron activation reactions than are normally encountered with stainless steel samples. The alloy composition consisted of nominally 1% (by weight) niobium, 1% tin, and 0.1% iron, with the balance zirconium. The activation products observed in the samples by gamma spectroscopy included Zr-95, Nb-95, Sn-113, Sb-125, Mn-54, Co-60, Nb-94, and Ta-182. The niobium was then chemically separated following ASTM procedure E1297 and the Nb-93m activities were measured by x-ray spectroscopy. The thermal neutron fluences, as determined independently by the neutron capture gamma reactions to Zr-95, Sn-113, Nb-94, and Sn/Sb-125, were in excellent agreement. The fast neutron fluences, as determined separately by the Fe-54(n,p)Mn-54 and Nb-93(n,n’)Nb-93m reactions, were also in good agreement, thus demonstrating the versatility of the retrospective dosimetry technique.

36 MATERIALS SCIENCE↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality x-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)} and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010)]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of replica-exchange umbrella sampling in GAMESS

In GAMESS-US quantum chemistry package, both replica-exchange molecular dynamics (REMD) and the umbrella sampling (US) methods are available. However, prior to this work, the replica-exchange umbrella sampling (REUS) method, combining REMD and US, was not implemented. Here, REUS affords a more efficient conformational sampling than the conventional US method and is often used in MD simulations. We implemented REUS in GAMESS-US and improved some routines of the existing REMD code. A density-functional tight-binding REMD (DFTB-REMD) simulation of alanine deca-peptide and a DFTB-MD REUS simulation of proton transfer in malonaldehyde were performed. The results of DFTB-MD REUS simulations performed with three different simulation packages were compared to validate our GAMESS-US implementation.

97 MATHEMATICS AND COMPUTING↗

Classifier-guided sampling for discrete variable, discontinuous design space exploration: Convergence and computational performance

A classifier-guided sampling (CGS) method is introduced for solving engineering design optimization problems with discrete and/or continuous variables and continuous and/or discontinuous responses. The method merges concepts from metamodel-guided sampling and population-based optimization algorithms. The CGS method uses a Bayesian network classifier for predicting the performance of new designs based on a set of known observations or training points. Unlike most metamodeling techniques, however, the classifier assigns a categorical class label to a new design, rather than predicting the resulting response in continuous space, and thereby accommodates nondifferentiable and discontinuous functions of discrete or categorical variables. The CGS method uses these classifiers to guide a population-based sampling process towards combinations of discrete and/or continuous variable values with a high probability of yielding preferred performance. Accordingly, the CGS method is appropriate for discrete/discontinuous design problems that are ill-suited for conventional metamodeling techniques and too computationally expensive to be solved by population-based algorithms alone. In addition, the rates of convergence and computational properties of the CGS method are investigated when applied to a set of discrete variable optimization problems. Results show that the CGS method significantly improves the rate of convergence towards known global optima, on average, when compared to genetic algorithms.

42 ENGINEERING↗

The Stanford Automated Mounter: Pushing the limits of sample exchange at the SSRL macromolecular crystallography beamlines

The Stanford Automated Mounter System, a system for mounting and dismounting cryo-cooled crystals, has been upgraded to increase the throughput of samples on the macromolecular crystallography beamlines at the Stanford Synchrotron Radiation Lightsource. This upgrade speeds up robot maneuvers, reduces the heating/drying cycles, pre-fetches samples and adds an air-knife to remove frost from the gripper arms. As a result, sample pin exchange during automated crystal quality screening now takes about 25 s, five times faster than before this upgrade.

43 PARTICLE ACCELERATORS↗

Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Discussion of Procedures and Equipment for the Comprehensive Test Ban Treaty On-Site Inspection Environmental Sampling and Analysis

This paper is intended to serve as a scientific basis to start discussions of the available environmental sampling techniques and equipment that have been used in the past that could be considered for use within the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) on-site inspections (OSI). This work contains information on the techniques, equipment, costs, and some operational procedures associated with environmental sampling that have actually been used in the past by the United States for the detection of nuclear explosions. This paper also includes a discussion of issues, recommendations, and questions needing further study within the context of the sampling and analysis of aquatic materials, atmospheric gases, atmospheric particulates, vegetation, sediments and soils, fauna, and drill-back materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Methods and Tools for Hanford Staged Feed Tank Sampling

This report summarizes work conducted by Pacific Northwest National Laboratory to technically evaluate the current approach to staged feed sampling of high-level waste (HLW) sludge to meet waste acceptance criteria (WAC) for transfer from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP). The current sampling and analysis approach is detailed in the document titled Initial Data Quality Objectives for WTP Feed Acceptance Criteria, 24590-WTP-RPT-MGT-11-014, Revision 0 (Arakali et al. 2011). The goal of this current work is to evaluate and provide recommendations to support a defensible, technical and statistical basis for the staged feed sampling approach that meets WAC data quality objectives (DQOs).

97 MATHEMATICS AND COMPUTING↗

Background Information for the Nevada National Security Site Integrated Sampling Plan, Revision 0

This document describes the process followed to develop the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan). It provides the Plan’s purpose and objectives, and briefly describes the Underground Test Area (UGTA) Activity, including the conceptual model and regulatory requirements as they pertain to groundwater sampling. Background information on other NNSS groundwater monitoring programs—the Routine Radiological Environmental Monitoring Plan (RREMP) and Community Environmental Monitoring Program (CEMP)—and their integration with the Plan are presented. Descriptions of the evaluations, comments, and responses of two Sampling Plan topical committees are also included.

54 ENVIRONMENTAL SCIENCES↗