Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

New Views of Materials through Aberration-Corrected STEM

The successful correction of lens aberrations in scanning transmission electron microscopy has allowed an improvement in resolution by a factor of two in just a few years. The benefits for materials research are far greater than a factor of two might imply, because enhanced resolution also brings enhanced image contrast, and therefore a vast increase in sensitivity to single atoms, both for imaging and electron energy loss spectroscopy. In addition, aberration correction enables simultaneous, aberrationcorrected, Z-contrast and phase contrast imaging, and brings a depth resolution at the nanometer level. It becomes possible to focus directly on features at different depths in the specimen thickness, and three-dimensional information can be extracted with single atom sensitivity. In conjunction with density functional and elasticity theory, these advances provide a new level of insight into the atomistic origins of materials properties. Several examples are discussed that illustrate the potential for applications, including the segregation of rare earth elements to grain boundaries in Si3N4 ceramics, the quantitative analysis of strain-induced growth phenomena in semiconductor quantum wells, the explanation of the enhanced thermal stability of La-doped -alumina as a catalyst support, and the origin of the remarkable catalytic activity of Au nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The DRAGO gamma camera

In this work, we present the results of the experimental characterization of the DRAGO (DRift detector Array-based Gamma camera for Oncology), a detection system developed for high-spatial resolution gamma-ray imaging. This camera is based on a monolithic array of 77 silicon drift detectors (SDDs), with a total active area of 6.7 cm{sup 2}, coupled to a single 5-mm-thick CsI(Tl) scintillator crystal. The use of an array of SDDs provides a high quantum efficiency for the detection of the scintillation light together with a very low electronics noise. A very compact detection module based on the use of integrated readout circuits was developed. The performances achieved in gamma-ray imaging using this camera are reported here. When imaging a 0.2 mm collimated {sup 57}Co source (122 keV) over different points of the active area, a spatial resolution ranging from 0.25 to 0.5 mm was measured. The depth-of-interaction capability of the detector, thanks to the use of a Maximum Likelihood reconstruction algorithm, was also investigated by imaging a collimated beam tilted to an angle of 45 deg. with respect to the scintillator surface. Finally, the imager was characterized with in vivo measurements on mice, in a real preclinical environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of tunnel injection through the Schottky gate on the static and noise behavior of GaInAs/AlInAs high electron mobility transistor

By using a Monte Carlo simulator, the influence of the tunnel injection through the Schottky contact at the gate electrode of a GaInAs/AlInAs High Electron Mobility Transistor (HEMT) has been studied in terms of the static and noise performance. The method used to characterize the quantum tunnel current has been the Wentzel-Kramers-Brillouin (WKB) approach. The possibility of taking into account the influence of the image charge effect in the potential barrier height has been included as well. Regarding the static behavior, tunnel injection leads to a decrease in the drain current I{sub D} due to an enhancement of the potential barrier controlling the carrier transport through the channel. However, the pinch-off is degraded due to the tunneling current. Regarding the noise behavior, since the fluctuations in the potential barrier height caused by the tunnel-injected electrons are strongly coupled with the drain current fluctuations, a significant increase in the drain-current noise takes place, even when the tunnel effect is hardly noticeable in the static I-V characteristics, fact that must be taken into account when designing scaled HEMT for low-noise applications. In addition, tunnel injection leads to the appearance of full shot noise in the gate current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vector magnetic field microscopy using nitrogen vacancy centers in diamond

The localized spin triplet ground state of a nitrogen vacancy (NV) center in diamond can be used in atomic-scale detection of local magnetic fields. Here we present a technique using ensembles of these defects in diamond to image fields around magnetic structures. We extract the local magnetic field vector by probing resonant transitions of the four fixed tetrahedral NV orientations. In combination with confocal microscopy techniques, we construct a two-dimensional image of the local magnetic field vectors. Measurements are done in external fields less than 50 G and under ambient conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial-frequency Fourier polarimetry of the complex degree of mutual anisotropy of linear and circular birefringence in the diagnostics of oncological changes in morphological structure of biological tissues

Theory of polarisation-correlation analysis of laser images of histological sections of biopsy material from cervix tissue based on spatial frequency selection of linear and circular birefringence mechanisms is formulated. Comparative results of measuring the coordinate distributions of the complex degree of mutual anisotropy (CDMA), produced by fibrillar networks formed by myosin and collagen fibres of cervix tissue in different pathological conditions, namely, pre-cancer (dysplasia) and cancer (adenocarcinoma), are presented. The values and variation ranges of statistical (moments of the first - fourth order), correlation (excess-autocorrelation functions), and fractal (slopes of approximating curves and dispersion of extrema of logarithmic dependences of power spectra) parameters of the CDMA coordinate distributions are studied. Objective criteria for pathology diagnostics and differentiation of its severity degree are determined. (image processing)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Application of Convolutional Neural Networks (CNNs) to Recognize Defects in 3D-Printed Parts

Cracks and pores are two common defects in metallic additive manufacturing (AM) parts. In this paper, deep learning-based image analysis is performed for defect (cracks and pores) classification/detection based on SEM images of metallic AM parts. Three different levels of complexities, namely, defect classification, defect detection and defect image segmentation, are successfully achieved using a simple CNN model, the YOLOv4 model and the Detectron2 object detection library, respectively. The tuned CNN model can classify any single defect as either a crack or pore at almost 100% accuracy. The other two models can identify more than 90% of the cracks and pores in the testing images. In addition to the application of static image analysis, defect detection is also successfully applied on a video which mimics the AM process control images. The trained Detectron2 model can identify almost all the pores and cracks that exist in the original video. This study lays a foundation for future in situ process monitoring of the 3D printing process.

36 MATERIALS SCIENCE↗

The thin section rock physics: Modeling and measurement of seismic wave velocity on the slice of carbonates

This paper discusses a new approach for investigating the seismic wave velocity of rock, specifically carbonates, as affected by their pore structures. While the conventional routine of seismic velocity measurement highly depends on the extensive laboratory experiment, the proposed approach utilizes the digital rock physics view which lies on the numerical experiment. Thus, instead of using core sample, we use the thin section image of carbonate rock to measure the effective seismic wave velocity when travelling on it. In the numerical experiment, thin section images act as the medium on which wave propagation will be simulated. For the modeling, an advanced technique based on artificial neural network was employed for building the velocity and density profile, replacing image's RGB pixel value with the seismic velocity and density of each rock constituent. Then, ultrasonic wave was simulated to propagate in the thin section image by using finite difference time domain method, based on assumption of an acoustic-isotropic medium. Effective velocities were drawn from the recorded signal and being compared to the velocity modeling from Wyllie time average model and Kuster-Toksoz rock physics model. To perform the modeling, image analysis routines were undertaken for quantifying the pore aspect ratio that is assumed to represent the rocks pore structure. In addition, porosity and mineral fraction required for velocity modeling were also quantified by using integrated neural network and image analysis technique. It was found that the Kuster-Toksoz gives the closer prediction to the measured velocity as compared to the Wyllie time average model. We also conclude that Wyllie time average that does not incorporate the pore structure parameter deviates significantly for samples having more than 40% porosity. Utilizing this approach we found a good agreement between numerical experiment and theoretically derived rock physics model for estimating the effective seismic wave velocity of rock.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in machine-learning-based sampling motivated by lattice quantum chromodynamics

Sampling from known probability distributions is a ubiquitous task in computational science, underlying calculations in domains from linguistics to biology and physics. Generative machine-learning (ML) models have emerged as a promising tool in this space, building on the success of this approach in applications such as image, text, and audio generation. Often, however, generative tasks in scientific domains have unique structures and features—such as complex symmetries and the requirement of exactness guarantees—that present both challenges and opportunities for ML. This Perspective outlines the advances in ML-based sampling motivated by lattice quantum field theory, in particular for the theory of quantum chromodynamics. Enabling calculations of the structure and interactions of matter from our most fundamental understanding of particle physics, lattice quantum chromodynamics is one of the main consumers of open-science supercomputing worldwide. Here, the design of ML algorithms for this application faces profound challenges, including the necessity of scaling custom ML architectures to the largest supercomputers, but also promises immense benefits, and is spurring a wave of development in ML-based sampling more broadly. In lattice field theory, if this approach can realize its early promise it will be a transformative step towards first-principles physics calculations in particle, nuclear and condensed matter physics that are intractable with traditional approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Efficiency Gain in 2D Perovskite Photo and X‐Ray Detectors

Abstract The perovskite polycrystalline thin film detector fabricated by solution method is a promising low‐cost, scalable technology for radiation imaging, but its thin volume limits the sensing efficiency for high‐energy X‐ray photons. This work reports 2D perovskite thin film photo‐diodes with a detection gain when sensing visible and X‐ray photons. Detailed power and temperature‐dependent device characterizations reveal a charge multiplication effect to be responsible for the observed high gain. This is caused by a disparity in electron and hole transport, where electron transport is retarded by a trap/de‐trap process via shallow trap states, whereas the hole transport is fast enough to produce a photoconductive gain in satisfying the charge neutrality. The 2D perovskite made with butylamine spacers is also found to exhibit a larger efficiency gain than those made with phenylethylamines because of the higher likelihood of forming shallow traps in the former. The thin film diodes feature a high temporal response over 1 MHz due to the fast charge collection across a thin volume, and the discovery provides device physics mechanisms in connection to material structure‐function relationship for future optoelectronics design that can boost the efficiency of X‐ray sensing and dim light detection.

2D perovskites↗

Applications of ultrafast nano-spectroscopy and nano-imaging with tip-based microscopy

Innovation in microscopy has often been critical in advancing both fundamental science and technological progress. Notably, the evolution of ultrafast near-field optical nano-spectroscopy and nano-imaging has unlocked the ability to image at spatial scales from nanometers to ångströms and temporal scales from nanoseconds to femtoseconds. This approach revealed a plethora of fascinating light-matter states and quantum phenomena, including various species of polaritons, quantum phases, and complex many-body effects. This review focuses on the working principles and state-of-the-art development of ultrafast tip-enhanced and near-field microscopy, integrating diverse optical pump-probe methods across the terahertz (THz) to ultraviolet (UV) spectral ranges. It highlights their utility in examining a broad range of materials, including two-dimensional (2D), organic molecular, and hybrid materials. The review concludes with a spatio-spectral-temporal comparison of ultrafast nano-imaging techniques, both within already well-defined domains, and offering an outlook on future developments of ultrafast tip-based microscopy and their potential to address a wider range of materials.

Zhao, Zhichen [Tongji University, Shanghai (China)↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ghost imaging for a reflected object with a rough surface

Ghost imaging for the reflected object with rough surface is investigated. The surface height variance {sigma}{sub h}{sup 2} and the correlation length l{sub c} have been introduced to characterize the rough surface. Based on a simple scattering model, we derive the analytical expressions which are used to describe the effects of {sigma}{sub h}{sup 2} and l{sub c} on ghost imaging. The results show that both {sigma}{sub h}{sup 2} and l{sub c} have no influence on the image resolution, while the convergence of the correlation decreases as {sigma}{sub h}{sup 2} increases. Additionally, the bucket detector used in the test arm can dramatically improve the visibility of ghost images. The results are backed up by numerical simulations, in which a Monte Carlo approach to generate a rough surface has been used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Epitaxial lift-off of quantum dot enhanced GaAs single junction solar cells

InAs/GaAs strain-balanced quantum dot (QD) n-i-p solar cells were fabricated by epitaxial lift-off (ELO), creating thin and flexible devices that exhibit an enhanced sub-GaAs bandgap current collection extending into the near infrared. Materials and optical analysis indicates that QD quality after ELO processing is preserved, which is supported by transmission electron microscopy images of the QD superlattice post-ELO. Spectral responsivity measurements depict a broadband resonant cavity enhancement past the GaAs bandedge, which is due to the thinning of the device. Integrated external quantum efficiency shows a QD contribution to the short circuit current density of 0.23 mA/cm{sup 2}.

36 MATERIALS SCIENCE↗

Deep-subwavelength imaging of both electric and magnetic localized optical fields by plasmonic campanile nanoantenna

Tailoring the electromagnetic field at the nanoscale has led to artificial materials exhibiting fascinating optical properties unavailable in naturally occurring substances. Besides having fundamental implications for classical and quantum optics, nanoscale metamaterials provide a platform for developing disruptive novel technologies, in which a combination of both the electric and magnetic radiation field components at optical frequencies is relevant to engineer the light-matter interaction. Thus, an experimental investigation of the spatial distribution of the photonic states at the nanoscale for both field components is of crucial importance. Here we experimentally demonstrate a concomitant deep-subwavelength near-field imaging of the electric and magnetic intensities of the optical modes localized in a photonic crystal nanocavity. We take advantage of the “campanile tip”, a plasmonic near-field probe that efficiently combines broadband field enhancement with strong far-field to near-field coupling. In conclusion, by exploiting the electric and magnetic polarizability components of the campanile tip along with the perturbation imaging method, we are able to map in a single measurement both the electric and magnetic localized near-field distributions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electron Tomography: Seeing Atoms in Three Dimensions

Our eyes - a parallel lens system - have the phenomenal ability to observe and "reconstruct" the three-dimensional world, relaying a 3-D image to our brains. Imaging of the nanoworld is best done with electrons rather than photons because of their lower wavelengths and higher resolution. The advent of aberration-correction has led to transmission electron microscopes with sub-Angstrom resolution that can resolve single atoms. Yet, no matter what detector is used, the resulting images are only two-dimensional projections of three-dimensional objects. Electron tomography is a technique that allows reconstruction of the three-dimensional structure and morphology of nanomaterials from such projections. X-ray tomography has been used in many branches of science for nearly half a century, and in the biological sciences electron tomography has been a powerful tool for understanding ultrastructure. However, for many years crystalline materials posed a challenge to electron tomography because diffraction contrast (a change in intensity in the image at particular crystal orientations) creates artifacts in the 3-D reconstruction. In 2003, with advances in scanning transmission electron microscopy, Midgley and colleagues obtained the first electron tomograms of crystalline materials. Shortly thereafter, Arslan et al. showed that the spatial resolution could be improved to 1 nm in all three spatial dimensions and visualized the formation of faceted 3.5-nm quantum dots embedded in a Si matrix. However, with that work existing reconstruction algorithms appeared to have reached their limit. To attain a resolution of 1 nm, a total of 140 images over ±78 degrees of tilt were needed. Writing in Nature Materials, Goris et al. now report a novel algorithm for 3-D reconstruction of the atomic structure of free-standing Au nanorods, using only four projection images. I.A. acknowledges collaboration with J.D. Roehling, K.J. Batenburg, B.C. Gates and A. Katz for Figure 1, supported in part by the DOE BES DE-SC0005822, and in part by the LDRD program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle under contract DE-AC05-76RL01830.

Arslan, Ilke↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗