Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

The Mark III VLBI System

Geodetic measurements have errors in centimeter range. Collection of three reports describes both equipment and results of some measurements taken with Mark III very-long-baseline interferometry (VLBI) system. Has demonstrated high accuracy over short baselines, where phase-delay measurements used. Advanced hardware, called Mark III A, developed to improve system performance and efficiency. Original Mark III hardware and III A subsystem upgrades developed as part of NASA Crustal Dynamics Project at Haystack Observatory.

Rogers, A. E. E.↗

Orbit determination of the Comet Rendezvous/Asteroid Flyby mission - Post-rendezvous phases

Orbit determination during the post-rendezvous phases of the Comet Rendezvous/Asteroid Flyby mission is described. The orbit determination process is discussed, with emphasis placed on optical imaging of landmarks and Doppler tracking. Rotational dynamics are introduced for the cometary nucleus. State estimation errors are given for spacecraft trajectory prediction and cometary nucleus attitude prediction. Estimation errors are also given for parameters that describe the cometary nucleus such as moments of inertia and gravity harmonics. The orbit determination performance in support of science observations while in orbit about the nucleus is described.

Miller, James K.↗

Photometric lightcurve observations and reduction techniques

Photoelectric light curves were used to determine the period of rotation, obtain the estimates of shape and pole orientation, and define the phase relation, or brightness as a function of solar phase angle, of asteroids. Methods for taking and reducing observations are described, with particular consideration given to the correction for atmospheric extinction, the use of Fourier analysis in constructing composite light curves, and the analysis of errors. Also discussed are computer programs that solve two principal problems: the determination of the time-variable extinction function for a night and the constuction of composite light curves.

Harris, A. W.↗

Studies of the horizontal vestibulo-ocular reflex in spaceflight

Changes in the vestibulo-ocular reflex (VOR) during space flight have been suspected of contributing to space motion sickness. The horizontal VOR was studied in nine subjects on two space shuttle missions. Active unpaced head oscillation at 0.3 Hz was used as the stimulus to examine the gain and phase of the VOR with and without visual input, as well as the visual suppression of the reflex. No statistically significant changes were noted inflight in the gains or phase shifts of the VOR during any test condition, or between space motion sickness susceptible and nonsusceptible populations. Although VOR suppression was unaffected by spaceflight, the space motion sickness-susceptible group tended to exhibit greater error in the suppression than the nonsusceptible group. It is concluded that at this stimulus frequency, VOR gain is unaffected by space-flight, and any minor individual changes do not seem to contribute to space motion sickness.

Thornton, William E.↗

Indirect planet detection with ground-based long-baseline interferometry

Narrow-angle astrometry with long-baseline infrared interferometers can provide extremely high accuracies as required for indirect planet detection. Narrow-angle astrometric interferometry exploits the properties of atmospheric turbulence over fields smaller than the interferometer baseline divided by the atmospheric scale height. For such fields, accuracy is linear with star separation, and nearly inversely proportional to baseline length. To exploit these properties, the interferometer observes a relatively bright (less than 13 mag(sub K)) target in the near infrared at 2.2 micrometers, and uses phase referencing to find a reference star within the 2.2-micrometers isoplanatic patch. With this technique faint references can be found for most targets. With baselines greater than 100 m, which also minimize photon-noise errors, and with careful control of systematic errors by using laser metrology, accuracies of tens of microarcseconds/square root of (hour) should be possible.

Colavita, M. M.↗

Pseudocoherent Demodulation Of DPSK Radio Signals

Three schemes for pseudocoherent demodulation of differential-phase-shift keyed (DPSK) radio signals proposed for use in land-mobile/satellite communications. Enables fast reacquisition. Also amounts to compromise between two extremes of coherent demodulation and differentially coherent demodulation, for which bit-error rates greater than those of coherent demodulation by amounts corresponding to difference of about 1 dB in bit-energy/noise-energy ratio. Based on maximum-likelihood estimation and detection during N-symbol observation periods, where N integer typically chosen between 5 and 15.

Divsalar, Dariush↗

Cell Kinetic and Histomorphometric Analysis of Microgravitational Osteopenia: PARE.03B

Previous methods of identifying cells undergoing DNA synthesis (S-phase) utilized 3H-thymidine (3HT) autoradiography. 5-Bromo-2'-deoxyuridine (BrdU) immunohistochemistry is a nonradioactive alternative method. This experiment compared the two methods using the nuclear volume model for osteoblast histogenesis in two different embedding media. Twenty Sprague-Dawley rats were used, with half receiving 3HT (1 micro-Ci/g) and the other half BrdU (50 micro-g/g). Condyles were embedded (one side in paraffin, the other in plastic) and S-phase nuclei were identified using either autoradiography or immunohistochemistry. The fractional distribution of preosteoblast cell types and the percentage of labeled cells (within each cell fraction and label index) were calculated and expressed as mean +/- standard error. Chi-Square analysis showed only a minor difference in the fractional distribution of cell types. However, there were,significant differences (p less than 0.05) by ANOVA, in the nuclear labeling of specific cell types. With the exception of the less-differentiated A+A' cells, more BrdU label was consistently detected in paraffin than in plastic-embedded sections. In general, more nuclei were labeled with 3H-thymidine than with BrdU in both types of embedding media (Fig 2.). Labeling index data (labeled cells/total cells sampled x 100) indicated that BrdU in paraffin, but not plastic gave the same results as 3HT in either embedding method. Thus, we conclude that the two labeling methods do not yield the same results.

Roberts, W. Eugene↗

Fault Detection and Correction for the Solar Dynamics Observatory Attitude Control System

The Solar Dynamics Observatory is an Explorer-class mission that will launch in early 2009. The spacecraft will operate in a geosynchronous orbit, sending data 24 hours a day to a devoted ground station in White Sands, New Mexico. It will carry a suite of instruments designed to observe the Sun in multiple wavelengths at unprecedented resolution. The Atmospheric Imaging Assembly includes four telescopes with focal plane CCDs that can image the full solar disk in four different visible wavelengths. The Extreme-ultraviolet Variability Experiment will collect time-correlated data on the activity of the Sun's corona. The Helioseismic and Magnetic Imager will enable study of pressure waves moving through the body of the Sun. The attitude control system on Solar Dynamics Observatory is responsible for four main phases of activity. The physical safety of the spacecraft after separation must be guaranteed. Fine attitude determination and control must be sufficient for instrument calibration maneuvers. The mission science mode requires 2-arcsecond control according to error signals provided by guide telescopes on the Atmospheric Imaging Assembly, one of the three instruments to be carried. Lastly, accurate execution of linear and angular momentum changes to the spacecraft must be provided for momentum management and orbit maintenance. In th~sp aper, single-fault tolerant fault detection and correction of the Solar Dynamics Observatory attitude control system is described. The attitude control hardware suite for the mission is catalogued, with special attention to redundancy at the hardware level. Four reaction wheels are used where any three are satisfactory. Four pairs of redundant thrusters are employed for orbit change maneuvers and momentum management. Three two-axis gyroscopes provide full redundancy for rate sensing. A digital Sun sensor and two autonomous star trackers provide two-out-of-three redundancy for fine attitude determination. The use of software to maximize chances of recovery from any hardware or software fault is detailed. A generic fault detection and correction software structure is used, allowing additions, deletions, and adjustments to fault detection and correction rules. This software structure is fed by in-line fault tests that are also able to take appropriate actions to avoid corruption of the data stream.

Starin, Scott R.↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a three-phase electric power, 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

grid-forming inverter↗

Estimating the Concentration of Large Raindrops from Polarimetric Radar and Disdrometer Observations

Estimation of rainfall integral parameters, including radar observables, and empirical relations between them are sensitive to the truncation of the drop size distribution (DSD), particularly at the large drop end. The sensitivity of rainfall integral parameters to the maximum drop diameter (D(sub max)) is exacerbated at C‐band since resonance effects are pronounced for large drops in excess of 5 mm diameter (D). Due to sampling limitations, it is often difficult to reliably estimate D(sub max) with disdrometers. The resulting uncertainties in D(sub max0 potentially increase errors in radar retrieval methods, particularly at C‐band, that rely on disdrometer observations for DSD input to radar models. In fact, D(sub max) is typically an assumed DSD parameter in the development of radar retrieval methods. Because of these very uncertainties, it is difficult to independently confirm disdrometer estimates of D(sub max) with polarimetric radar observations. A couple of approaches can be taken to reduce uncertainty in large drop measurement. Longer integration times can be used for the collection of larger disdrometer samples. However, integration periods must be consistent with a radar resolution volume (RRV) and the temporal and spatial scales of the physical processes affecting the DSD therein. Multiple co‐located disdrometers can be combined into a network to increase the sample size within a RRV. However, over a reasonable integration period, a single disdrometer sample volume is many orders of magnitudes less than a RRV so it is not practical to devise a network of disdrometers that has an equivalent volume to a typical RRV. Since knowledge of DSD heterogeneity and large drop occurrence in time and space is lacking, the specific accuracy or even general representativeness of disdrometer based D(sub max) and large drop concentration estimates within a RRV are currently unknown. To address this complex issue, we begin with a simpler question. Is the frequency of occurrence of large rain drops (D > 5 mm) in disdrometer observations, either stand alone or networked, generally representative and consistent with polarimetric radar observations? We first show from simulations that the concentration of large (D > 5 mm) rain drops (N(sub T5)) can be estimated from polarimetric observations of specific differential phase (K(sub dp)) and differential reflectivity (Z(sub dr)), N(sub T5)=F(K(sub dp),Z(sub dr)), or horizontal reflectivity (Z(sub h)) and Z(sub dr), N(sub T5)=(Z(sub h),Z(sub dr)). We assess the error associated with polarimetric retrieval of N(sub T5), including sensitivity to D(sub max) parameterization assumptions and measurement error in the radar simulations. Polarimetric measurements at S‐band and C‐band will then be used to retrieve estimates of N(sub T5) and compared to disdrometer estimates of N(sub T5). After careful consideration of retrieval error, we will check consistency between disdrometer and polarimetric radar estimates of N(sub T5) and the frequency of occurrence of large rain drops in a variety of precipitating regimes using data from NASA's Global Precipitation Measurement (GPM) Ground Validation (GV) program, including field campaigns such as MC3E (Oklahoma) and IFloodS (Iowa) and extended measurements over Huntsville, Alabama and NASA Wallops Flight Facility in coastal Virginia.

Carey, Lawrence D.↗

MODIS Aerosol and Low‐Cloud Retrievals: Orographic Effects in the Wake of Macquarie Island

Abstract Visible/infrared imagery from passive satellites is commonly relied upon to study low cloud microphysics over oceanic regions, including for the Southern Ocean (SO), but relatively little validation has been undertaken for the SO. In this article, we compare low‐cloud effective radius ( r e ), cloud droplet number concentration ( N d ) and cloud liquid water path (LWP) retrievals from the NASA Moderate Imaging Spectroradiometer (MODIS) with surface measurements collected during the Macquarie Island Cloud and Radiation Experiment (MICRE). MODIS 3.7‐μm band retrievals show little bias and moderately good correlation relative to MICRE retrievals for liquid‐phase low clouds when restricted to Solar Zenith Angles <65° on spatial scales of 50–100 km. However, the low overall bias in 3.7‐μm band effective radius ( r e 3.7 ) retrievals partly results from cancellation of errors: r e 3.7 is overestimated for non‐to‐lightly precipitating clouds, and underestimated for heavier drizzling clouds by ∼1–1.5 μm. 1.6‐μm and 2.1‐μm band r e retrievals are biased high. N d may likewise be slightly under‐ or overestimated depending on the concentration, but there is insufficient data to provide confidence in this result. Interestingly, a composite of MODIS retrievals from 2002 to 2020 show a distinct region of enhanced cloud cover and N d (and lower r e ) in the wake of Macquarie Island associated with orographic cloud formation. MODIS retrievals of aerosol optical depth (AOD) and Angstrom Exponent (AE) upwind and downwind of the island do not differ significantly. Comparison with MICRE measurements suggests that MODIS Collection 6 AOD retrievals are reasonable, while AE is problematically large.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous x-ray diffraction measurements of nine pressure calibrants to 140 GPa

Accurate pressure calibration is fundamental to quantitative high-pressure science, yet inconsistencies among widely used secondary pressure scales persist. In this work, we report simultaneous synchrotron x-ray diffraction meatogether in diamond anvil cells to 140 GPa. This simultaneous-measurement strategy minimizes transitive errors and run-to-run inconsistencies inherent to paired-measurement approaches, yielding direct experimental volume-volume (V-V) relations among the calibrants. These V-V relations link the compression state of each phase to that of every other phase measured in the same experiment. By anchoring these V-V relations to the reduced 300 K equation of state (EOS) of copper derived from ramp-compression measurements, we derive an internally consistent set of Cu-referenced pressure scales via Vinet EOS fits. Because the primary experimental result is the V-V dataset, it provides an EOS-independent constraint that can be rereferenced if primary standards are revised. The dataset further enables a direct experimental cross-check of consistency between the adopted reduced 300 K Cu EOS and the corresponding reduced 300 K ramp-derived EOSs for Pt, Au, Ta, and hcp-Fe under a fixed V-V constraint. The residuals quantify small, material-dependent mismatches between each phase EOS and the Cu reference EOS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging machine learning to enhance aerosol classification using Single-Particle Mass Spectrometry

Advancing automated classification of atmospheric aerosols from Single-Particle Mass Spectrometry (SPMS) data remains challenging due to overlapping ion signatures, compositional diversity, and limited labeled data. This study evaluates supervised and semi-supervised learning frameworks to enhance aerosol identification by jointly leveraging labeled and unlabeled spectra. Four models were compared: a supervised Support Vector Machine (SVM), a self-training SVM, a stacked autoencoder classifier, and a stacked autoencoder trained using a temporal-ensembling Mean Teacher approach. All models achieved high and stable accuracies (90.0 %–91.1 %), surpassing previous results on the same dataset (87 %) and matching the performance of state-of-the-art deep learning methods. Despite small global metric differences (≤ 1 %), semi-supervised variants yielded up to 5 %–10 % improvements for compositionally rare particle types – such as soot (0.77 % of spectra, F1-score: 0.93–0.97) and hazelnut pollen (0.98 % of spectra, F1-score: 0.97–1.00) – equating to roughly ∼ 187 additional correctly classified spectra. These gains are scientifically significant, as such rare particles exert disproportionate influence on radiative absorption and ice nucleation processes; their improved detection reduces modeled uncertainties in aerosol absorption optical depth and mixed-phase cloud ice nucleation rates. The models' residual misclassifications (≈ 9 %) largely arise from true spectral overlap among chemically adjacent species (e.g., Na- vs. K-feldspar, coated vs. uncoated feldspars), reflecting physical compositional continuity rather than algorithmic error. Collectively, these findings demonstrate that leveraging unlabeled data to learn robust spectral representations and refine classification enhances both fidelity and interpretability, bridging data-driven analysis with aerosol–climate process understanding.

54 ENVIRONMENTAL SCIENCES↗

Ozone measurement systems improvements studies

Results are summarized of an initial study of techniques for measuring atmospheric ozone, carried out as the first phase of a program to improve ozone measurement techniques. The study concentrated on two measurement systems, the electro chemical cell (ECC) ozonesonde and the Dobson ozone spectrophotometer, and consisted of two tasks. The first task consisted of error modeling and system error analysis of the two measurement systems. Under the second task a Monte-Carlo model of the Dobson ozone measurement technique was developed and programmed for computer operation.

Thomas, R. W.↗

Evaluation of Bayesian Sequential Proportion Estimation Using Analyst Labels

The author has identified the following significant results. A total of ten Large Area Crop Inventory Experiment Phase 3 blind sites and analyst-interpreter labels were used in a study to compare proportional estimates obtained by the Bayes sequential procedure with estimates obtained from simple random sampling and from Procedure 1. The analyst error rate using the Bayes technique was shown to be no greater than that for the simple random sampling. Also, the segment proportion estimates produced using this technique had smaller bias and mean squared errors than the estimates produced using either simple random sampling or Procedure 1.

Lennington, R. K.↗

Effects of spacecraft reflections on RF interferometer position location accuracy

This report describes one of three study tasks related to the application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters. Computer modeling was used to estimate the error in the measured signal angle-of-arrival caused by reflection and diffraction off the spacecraft. Existing computer codes (NEC-BSC) were modified and used to determine the perturbation, due to the spacecraft, in the phase difference between two interferometer antennas, suspended on either side of the spacecraft. This phase perturbation was found as a function of the angle-of-arrival of the signal from a far-field source. The spacecraft antennas were assumed to be circularly polarized with a cardioid pattern. It was found that the perturbation was as much 12.4 deg within the + or - 60 deg field-of-view. This suggests that phase calibration and correction of phase measurements are essential for precision position location using this technique.

Wallace, R. G.↗