Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Renewal: Coherent control of spin states in organic electronics – discovery and investigation of complex room-temperature magnetic quantum excitations

In the course of four funding cycles of this project, its research focused on the exploration and understanding of spin-dependent electronic processes in organic semiconductors. It aimed to investigate the potential of harnessing the spin degree of freedom in organic materials for various applications such as spin electronics, quantum information, sensors, and as well as quantum coherent spin phenomena of charge carrier states in organic semiconductors, with the aim to develop room-temperature-based quantum applications. Specifically, the project aimed to: Apply new diagnostic tools, i.e. spin spectroscopy techniques, for paramagnetic charge carrier states in organic semiconductors, based on coherent control with pulsed electron spin resonance to understand spin relaxation and spin mixing mechanisms in organic semiconductor materials and devices such as OLEDs. Explore the nature of charge carrier spin-coupling and pathways for its manipulation to control the physical behaviors of these materials. This involves investigating spin interactions through materials structure, composition, morphological dependencies, isotopic effects, and externally applied electric and magnetic fields, with the goal to manipulate electrical and optical material properties by adjusting spin-orbit, spin-dipolar, spin-exchange, as well as spin-hyperfine interactions to open up this materials class for new applications. Study spin-dependent charge carrier transport and recombination and how these observables are governed by spin-propagation, especially coherent spin propagation as well as collective spin-effects such as the spin-Dicke effect and resonant multi-photon magnetic dipole transitions. The project utilized pulsed electrically detected magnetic resonance (pEDMR) and pulsed optically detected magnetic resonance (pODMR) techniques over a wide frequency range. These techniques enabled the observation and quantification of various spin-spin coupling types, including spin-exchange, spin-dipolar, hyperfine, and spin-orbit interactions. The project will leverage low- to mid-frequency pEDMR/pODMR facilities and collaboration with the National High Magnetic Field Laboratory.

36 MATERIALS SCIENCE↗

Global to Microscale Evolution of the Pinatubo Volcanic Aerosol Derived from Diverse Measurements and Analyses

We assemble data on the Pinatubo aerosol from space, air, and ground measurements, develop a composite picture, and assess the consistency and uncertainties of measurement and retrieval techniques. Satellite infrared spectroscopy, particle morphology, and evaporation temperature measurements agree with theoretical calculations in showing a dominant composition of H2SO4-H20 mixture, with H2SO4 weight fraction of 65-80% for most stratospheric temperatures and humidities. Important exceptions are (1) volcanic ash, present at all heights initially and just above the tropopause until at least March 1992, and (2) much smaller H2SO4 fractions at the low temperatures of high-latitude winters and the tropical tropopause. Laboratory spectroscopy and calculations yield wavelength- and temperature-dependent refractive indices for the H2SO4-H20 droplets. These permit derivation of particle size information from measured optical depth spectra, for comparison to impactor and optical-counter measurements. All three techniques paint a generally consistent picture of the evolution of R(sub eff), the effective radius. In the first month after the eruption, although particle numbers increased greatly, R(sub eff) outside the tropical core was similar to preeruption values of approx. 0.1 to 0.2 microns, because numbers of both small (r < 0.2 microns) and large (r > 0.6 microns) particles increased. In the next 3-6 months, extracore R(sub eff) increased to approx. 0.5 microns, reflecting particle growth through condensation and coagulation. Most data show that R(sub eff) continued to increase for about 1 year after the eruption. R(sub eff) values up to 0.6 - 0.8 microns or more are consistent with 0.38 - 1 micron optical depth spectra in middle to late 1992 and even later. However, in this period, values from in situ measurements are somewhat less. The difference might reflect in situ undersampling of the very few largest particles, insensitivity of optical depth spectra to the smallest particles, or the inability of flat spectra to place an upper limit on particle size. Optical depth spectra extending to wavelengths lambda > 1 micron are required to better constrain R(sub eff), especially for R(sub eff) > 0.4 microns. Extinction spectra computed from in situ size distributions are consistent with optical depth measurements; both show initial spectra with lambda(sub max) <= 0.42 microns, thereafter increasing to 0.78 <= lambda(sub max) <= 1 micron. Not until 1993 do spectra begin to show a clear return to the preeruption signature of lambda(sub max) <= 0.42 microns. The twin signatures of large R(sub eff) (> 0.3 microns) and relatively flat extinction spectra (0.4 - 1 microns) are among the longest-lived indicators of Pinatubo volcanic influence. They persist for years after the peaks in number, mass, surface area, and optical depth at all wavelengths <= 1 microns. This coupled evolution in particle size distribution and optical depth spectra helps explain the relationship between global maps of 0.5- and 1.0-micron optical depth derived from the Advanced Very High Resolution Radiometer (AVHRR) and Stratospheric Aerosol and Gas Experiment (SAGE) satellite sensors. However, there are important differences between the AVHRR and SAGE midvisible optical thickness products. We discuss possible reasons for these differences and how they might be resolved.

Russell, P. B.↗

Meter-scale plasma waveguides for multi-GeV laser wakefield acceleration

Here, we present results from two new techniques for the generation of meter-scale, low density (~10 17 cm -3 on axis) plasma waveguides, the “two-Bessel” technique, and the “self-waveguiding” technique. Plasma waveguides of this density and length range are needed for demonstration of a ~10 GeV laser wakefield accelerator module, key for future staging for a ~TeV lepton collider. Both techniques require the use of high quality ultrashort pulse Bessel beams to efficiently and uniformly ionize hydrogen gas in meter-scale supersonic gas jets via optical field ionization. We review these two techniques, describe our meter-scale gas jets, and present a new method for correction of optical aberrations in Bessel beams. Finally, we briefly present results from recent experiments employing one of our techniques, demonstrating quasi-monoenergetic acceleration of ~5 GeV electron bunches in 20 cm long, low density plasma waveguides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An improved large-field focusing schlieren system

The analysis and performance of a high-brightness large-field focusing schlieren system is described. The system can be used to examine complex two- and three-dimensional flows. Techniques are described to obtain focusing schlieren through distorting optical elements, to use multiple colors in a time multiplexing technique, and to use diffuse screen holography for three-dimensional photographs.

Weinstein, Leonard M.↗

Operando Optical Microscopy for Visualization of Dendrite Growth in an Argyrodite LPSCl–Polymer Composite Electrolyte

Herein, we demonstrate the utility of optical microscopy as an accessible technique for the in situ visualization of dendrite growth within polymer–sulfide composite solid-state electrolytes. The composite electrolyte features in situ polymerization and cross-linking of the polymer between ceramic particles, which opens up extensive opportunities for accelerated materials discovery, given the vast array of acrylate/methacrylate monomers available. Specifically, the cross-linked polymer poly(triethylene glycol dimethacrylate) (poly(TEGDMA)) was observed to effectively fill pores and inhibit dendrite growth at the lithium metal interface, attributed to its glassy state at room temperature. This work represents the first application of optical microscopy to illustrate that the incorporation of glassy, undoped polymers such as poly(TEGDMA) can serve as a viable strategy for dendrite suppression in solid-state composite electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron impact spectroscopy

The concepts of electron impact spectroscopy are discussed, comparing the electron spectroscopy techniques with those of the optical spectroscopy. The main advantage of the electron spectroscopy is to be found in the elimination of optical selection rules in excitation processes and the ability to scan the spectrum from the infrared to the X-ray region. The range of the method is indicated through a review of several examples, including electron impact excitation of Ba and rotational excitation of H2. The sensitivity of the method is demonstrated by vibrational excitation spectrum of N2. It is shown that the application of the method to the inner-shell excitation allows to obtain information about molecular species which are not commonly available, while spectroscopy of negative ions yields information about their energy and symmetry properties. However, the techniques are still under development and more data are expected to become available in the coming years.

Trajmar, S.↗

Word timing recovery in direct detection optical PPM communication systems with avalanche photodiodes using a phase lock loop

A technique for word timing recovery in a direct-detection optical PPM communication system is described. It tracks on back-to-back pulse pairs in the received random PPM data sequences with the use of a phase locked loop. The experimental system consisted of an 833-nm AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector, and it used Q = 4 PPM signaling at source data rate 25 Mb/s. The mathematical model developed to describe system performance is shown to be in good agreement with the experimental measurements. Use of this recovered PPM word clock with a slot clock recovery system caused no measurable penalty in receiver sensitivity. The completely self-synchronized receiver was capable of acquiring and maintaining both slot and word synchronizations for input optical signal levels as low as 20 average detected photons per information bit. The receiver achieved a bit error probability of 10 to the -6th at less than 60 average detected photons per information bit.

Sun, Xiaoli↗

LOXT mirror design study

The final report for the large orbiting X-ray telescope (LOXT) high resolution mirror design study is presented. The following tasks were performed: (1) Generation of a reference and alternate preliminary design for the LOXT high resolution mirror assembly, which will meet the LOXT scientific requirements, and are within the present state of the art of materials and fabrication techniques. (2) Measurement, in X-rays, of the scattering properties of a variety of optical flats, embodying materials, coatings, and polishing techniques which might be applicable to the flight configuration LOXT high resolution mirror. (3) Preparation of a procurement specification for a paraboloid test mirror of the size of the innermost paraboloid of the high resolution mirror assembly, including the design requirements for the reference design evolved from this preliminary design study. The results of the engineering and scientific analysis and the conclusions drawn are presented. The procurement specification for the test mirror is included.

Vanspeybroeck, L.↗

Current developments in optical engineering and commercial optics; Proceedings of the Meeting, San Diego, CA, Aug. 7-11, 1989

Various papers on current developments in optical engineering and commercial optics are presented. Individual topics addressed include: large optics fabrication technology drivers and new manufacturing techniques, new technology for beryllium mirror production, design examples of hybrid refractive-diffractive lenses, optical sensor designs for detecting cracks in optical materials, retroreflector field-of-view properties for open and solid cube corners, correction of misalignment-dependent aberrations of the HST via phase retrieval, basic radiometry review for seeker test set, radiation effects on visible optical elements, and nonlinear simulation of efficiency for large-orbit nonwiggler FELs.

Fischer, Robert E.↗

Comparison of machine learning techniques to optimize the analysis of plutonium surrogate material via a portable LIBS device

The utilization of machine learning techniques has become commonplace in the analysis of optical emission spectra. These methods are often limited to variants of principal components analysis (PCA), partial-least squares (PLS), and artificial neural networks (ANNs). A plethora of other techniques exist and are well established in the world of data science, yet are seldom investigated for their use in spectroscopic problems. In this study, machine learning techniques were used to analyze optical emission spectra of laser-induced plasma from ceria pellets doped with silicon in order to predict silicon content. Additionally, a boosted regression ensemble model was created, and its predictive accuracy was compared to that of traditional PCA, PLS, and ANN regression models. Boosted regression tree ensembles yielded fits with R-squared (R2) values as high as 0.964 and mean-squared errors of prediction (MSEPs) as low as 0.074, providing the most accurate predictive model. Neural networks performed with slightly lower R2 values and higher MSEPs compared to the ensemble methods, thus indicating susceptibility to overfitting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

ABSTRACT Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. Our results demonstrate a distinct correlation between fungal species and their elemental profile, regardless of the substrate media, as the same strains shared a similar uptake of carbon, zinc, phosphorus, manganese, and magnesium, which could play a vital role in their survival and propagation. Independently, each fungal species exhibited a unique elemental profile. This work demonstrates a unique and valuable approach to rapidly phenotype fungi through optical spectroscopy, and this approach can be critical in understanding these fungi's behavior and interactions with the environment. IMPORTANCE Historically, ionomics, the elemental profiling of an organism or materials, has been used to understand the elemental composition in waste materials to identify and recycle heavy metals or rare earth elements, identify the soil composition in space exploration on the moon or Mars, or understand human disorders or disease. To our knowledge, ionomic profiling of microbes, particularly fungi, has not been investigated to answer applied and fundamental biological questions. The reason is that current ionomic analytical techniques can be laborious in sample preparation, fail to measure all potential elements accurately, are cost-prohibitive, or provide inconsistent results across replications. In our previous efforts, we explored whether laser-induced breakdown spectroscopy (LIBS) could be used in determining the elemental profiles of poplar tissue, which was successful. In this proof-of-concept endeavor, we undertook a transdisciplinary effort between applied and fundamental mycology and elemental analytical techniques to address the biological question of how LIBS can used for fungi grown axenically in a nutrient-rich and nutrient-poor environment.

59 BASIC BIOLOGICAL SCIENCES↗

Projector Selection for SOFAST Testing

In Concentrating Solar Power (CSP) there is a need for mirrors that are optically accurate, as they are used to focus light onto a receiver at high concentration. To test the accuracy of the mirrors’ optical slopes, we employ a technique called deflectometry. Deflectometry measures mirror slope directly. A projector displays an image onto a screen or wall, and a mirror is positioned to reflect the image to a camera. The camera sees the mirror’s reflection of the screen and sends imaging information to software which analyzes the reflected images from the mirror to determine the local slopes and curvature of the mirror. For this, projectors that can provide a crisp and clear image are imperative. Choosing the right projector(s) can be a long and tedious process; this paper will cover the process we used to select projectors for the SOFAST systems in the Sandia Concentrating Solar Optics Laboratory (CSOL).

14 SOLAR ENERGY↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Physiological factors and optical parameters as bases of vegetation discrimination and stress analysis.

The successful application of photographic, optical-mechanical scanning, and other sensing techniques to vegetation must be based on an understanding of the biological and physical principles involved. The objective is to review the biological and optical characteristics of vegetation and to discuss how knowledge of them can support operational programs by aiding in wavelength selection, timing of missions, and discriminations between vegetation types as well as between healthy and stressed plants of the same type. Both laboratory situations, in which relatively pure spectral data are obtained, and field situations are considered. In the latter, sensor performance and background variables affect data quality.

Wiegand, C. L.↗

Preliminary parameter studies to form pellets of hard materials for optical constants derived via single-angle reflectance spectroscopy

Infrared reflectance spectra can be influenced by many factors: the substrate and the thickness of the layer for liquids and the surface micromorphology, the form (powder, crystal) and the particle size for solids. All these parameters can play a role in the appearance of the measured spectrum. To avoid collecting multitudes of spectra to cover all such scenarios, the optical constants n and k, which are intrinsic properties of a material, can instead be used to model the reflectance spectrum. For solids, two techniques are often used to derive optical constants: ellipsometry and single-angle reflectance spectroscopy. For both methods, best results are usually obtained from single crystals. We have recently demonstrated for ammonium sulfate (a relatively soft material) that by optimizing certain conditions, high quality pellets with specularly reflective surfaces can be used in lieu of crystals. This was confirmed by the excellent agreement between the optical constants derived by these two methods. This work focuses on the possible extension of these methods to harder materials, starting with sodium sulfate. The first goal is to see if high quality pellet surfaces can be obtained as for ammonium sulfate. The reflectance values and the associated optical constants can also be obtained.

Diaz, Emmanuela↗

Molecular Optoelectronics (Final Technical Report)

The project developed new theoretical tools for analysis of nanodevices subjected to external optical and bias driving. Traditional theoretical techniques for molecular optoelectronics are either based on kinetic schemes or utilize quasiparticle description. The former fails to account for quantum mechanics of the system-bath interface and may fail qualitatively when used in open interacting systems. The latter is inconvenient in (usual for molecular optical spectroscopy) many body states description of the system. We developed a new technique - the Hubbard nonequilibrium Green's functions method - which allows to avoid shortcomings of standard theoretical approaches. The Hubbard NEGF was applied to analysis of experimental measurements of photoinduced current and bias-induced electroluminescence in STM molecular junctions. We also demonstrated practical usefulness of the Hubbard NEGF within newly proposed universal theory of current-induced forces for nonadiabatic molecular dynamics which generalizes celebrated Head-Gordon and Tully expression for electronic friction. Finally, following latest trends in laser techniques we studied local responses (local fluxes and local noise spectroscopy) of biased junctions as a source of information not accessible by total responses (total fluxes and noises) of the system.

30 DIRECT ENERGY CONVERSION↗