Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mobility challenges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,659 records · Page 93

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

±Characterization of Group V Dubnium Homologs on DGA Extraction Chromatography Resin from Nitric and Hydrofluoric Acid Matrices and Initial Investigation of Element 114 Homolog Ge

Studies of the chemical properties of superheavy elements (SHE) pose interesting challenges due to their short half-lives and low production rates. Chemical systems must have extremely fast kinetics, fast enough kinetics to be able to examine the chemical properties of interest before the SHE decays to another nuclide. To achieve chemistry on such time scales, the chemical system must also be easily automated. Most importantly however, a chemical system must be developed which provides suitable separation and kinetics before an on-line study of a SHE can be performed. Relativistic effects make studying the chemical properties of SHEs interesting due to the impact these effects could have on the SHEs chemical properties. Relativistic effects arise when the velocity of the s orbital electrons approach the speed of light. As this velocity increases, the Bohr radius of the inner electron orbitals decreases and there is an increase in the particles mass. This contraction results in a destabilization of the energy of the outer d and f electron orbitals (5f and 6d in the case of SHE), which can cause these to expand due to their increased shielding from the nuclear charge. Another relativistic effect is the spin-orbit splitting for p, d, and f orbitals into j = 1 1/2 states. This can lead most interestingly to a possible increased stability of element 114, which due to large spin-orbit splitting of the 7p orbital and the relativistically stabilized 7p 1/2 and 7s orbital gives rise to a closed shell ground state of 7s 2 7p 1/2 2 . The homologs of element 105, dubnium (Db), Ta and Nb and the pseudo-homolog Pa, are well known to hydrolyze and form both neutral and non-neutral monoatomic and polyatomic species that may cause issues with extraction from a given chemical system. Early ion-exchange and solvent-extraction studies show mixed results for the behavior of Db. Some studies show Db behaving most similar to Ta, while others show it behaving somewhere between Nb and Pa. Much more recent studies have examined the properties of Db from HNO 3 /HF matrices, and suggest Db forms complexes similar to those of Pa. Very little experimental work into the behavior of element 114 has been performed. Thermochromatography experiments of three atoms of element 114 indicate that the element 114 is at least as volatile as Hg, At, and element 112. Lead was shown to deposit on gold at temperatures about 1000 C higher than the atoms of element 114. Results indicate a substantially increased stability of element 114. No liquid phase studies of element 114 or its homologs (Pb, Sn, Ge) or pseudo-homologs (Hg, Cd) have been performed. Theoretical predictions indicate that element 114 is should have a much more stable +2 oxidation state and neutral state than Pb, which would result in element 114 being less reactive and less metallic than Pb. The relativistic effects on the 7p 1/2 electrons are predicted to cause a diagonal relationship to be introduced into the periodic table. Therefore, 114 2+ is expected to behave as if it were somewhere between Hg 2+ , Cd 2+ , and Pb 2+ . In this work two commercially available extraction chromatography resins are evaluated, one for the separation of Db homologs and pseudo?homologs from each other as well as from potential interfering elements such as Group IV Rf homologs and actinides, and the other for separation of element 114 homologs. One resin, Eichrom's DGA resin, contains a N,N,N',N'-tetra-n-octyldiglycolamide extractant, which separates analytes based on both size and charge characteristics of the solvated metal species, coated on an inert support. The DGA resin was examined for Db chemical systems, and shows a high degree of selectivity for tri-, tetra-, and hexavalent metal ions in multiple acid matrices with fast kinetics. The other resin, Eichrom's Pb resin, contains a di-t-butylcyclohexano 18-crown-6 extractant with isodecanol solvent, which separates analytes based on steric interactions between the cavity of the crown ether and electrostatic interactions between the oxygen's of the ether and cations in the mobile phase. This particular resin has been shown to have an extremely high uptake affinity for Pb, a direct homolog of element 114, and is thus a good initial extractant to examine for a potential element 114 chemical system. Figure 1.1 shows the respective extractant molecules from the DGA and Pb resins. Batch uptake experiments were conducted to examine the uptake behavior of Ta on the DGA resin. Batch uptake experiments were also conducted to examine the uptake behavior of Ge on the Pb resin. Column experiments were designed based on batch uptake experiments of Ta, Am, Pa, Np, Zr, and Nb to establish a sequential extraction of Group IV/V homologs as well as Am for potential use as a Db chemical system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Solid-state Architecture Batteries for Enhanced Rechargeability and Safety (SABERS) for Extended Deep Space Applications

Extended duration deep space missions as well as permanent space habitats face numerous technical challenges, key among them is energy generation and energy storage. There are considerable monetary and technical barriers to the generation of power in space. Therefore, it is important to store and be able to access power in an efficient and safe manner over a large number of cycles. Energy storage and in particular, batteries, are vital to the operation of next-generation extraterrestrial shuttles, rovers, habitats and extravehicular activity (EVA) space suits. The performance metrics for extended duration space missions are at least 2 times greater than those set for terrestrial applications such as electric automobiles. Furthermore, safety is essential for operation of space missions particularly involving astronauts such as shuttles, habitats and EVA space suits. Preliminary systems level analysis has indicated that there are five key properties which must be optimized for successful implementation of battery systems. Those five key criteria are: safety, energy density, power, packaging design and scalability. Current state-of-the-art (SOA) lithium-ion batteries can meet or exceed the requirements for certain space applications in the areas of power and scalability, yet are insufficient in the key performance criteria of energy, safety and packaging design. The SABERS concept proposes a battery that meets all five key performance criteria through development of a solid-state architecture battery utilizing high capacity sulfur-selenium cathode and lithium metal anode. The combination of sulfur and selenium offers a balanced energy-to-power density ratio, which can be tailored to the specific application by altering the stoichiometric ratios of sulfur to selenium. This hybrid cathode will be developed by implementing NASA patented holey graphene technology as a highly conductive, ultra-lightweight electrode scaffold. A solid-state electrolyte will be used as a safe, non-flammable replacement to the highly flammable liquid organic electrolytes currently used in SOA lithium-ion batteries. This solid-state lithium-sulfur/selenium cell will be designed into a serial stacking configuration to enable dense packaging of the battery cells. The serial stacking configuration is termed a bipolar stack, which has the advantages of reducing overall cell weight, simplifying the interfaced connections for the cell, and minimizing the cooling requirements for the cell. Lastly, optimization of battery components will occur through a robust and rigorous combination of various computational modeling techniques covering multiple length scales. The expected result will be a fully solid-state battery with operational temperatures up to 150 °C which provides the required energy density, discharge rates, and inherent safety to meet the strict space mission performance criteria. In particular, the wide operational temperature window is required for the large temperature ranges which are experienced across a broad range of potential space missions. This presentation will show initial results that demonstrate the SABERS team has developed a composite carbon-sulfur cathode which exceeds 1100 Wh/kg at a discharge rate of 0.4C, and 804 Wh/kg at a discharge rate of 1C. Additionally, this presentation will show the SABERS team multiscale computational modeling approach and has produced a novel particle dynamics method called Solid Electrolyte Sphere Approximation Model (SESAM). SESAM is on the 1-10 µm scale and provides electromechanical and grain interactions for predictive design guidelines for the experimental team to follow.

Urban Air Mobility (UAM) Vehicles↗