Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Hybrid Propulsion Emulation Rig (HyPER)

HyPER is a hardware-in-the-loop laboratory that was designed specifically to investigate the dynamic interactions between turbomachinery, the electric power system, and the constantly varying loads of electrified aircraft. It is a small-scale lab capable of rapid reconfiguration through software. This allows the emulation of new engines using simulation models that are easily replaced and then appropriately scaled for power and inertia to the test hardware.

Control↗

1016516285-AA - Handling Frame Assembly Table Structural and Seismic Analysis

Within the NIF (National Ignition Facility) sustainment project, LLNL is replacing all 1,728 blast shields with new ones. Before the new blast shield glass can be installed on NIF, it must pass through the AMOL (Amplifier Main Optics Loop). The AMOL process involves cleaning and coating the glass, assembling it into a Line Replaceable Unit (LRU), and performing testing and inspection. This work will be conducted in the OPFX cleanroom facility (Building 391, Room 1250) and requires several pieces of custom equipment. One key piece of equipment within the loop is the Handling Frame Assembly Table (see Figure 1.1). Its purpose is to assist operators in installing the blast shield glass into handling frames (1014442709) (see Figure 1.2). The table is also used to store handling frame assembly components. The primary components stored are the L-frames (1015208271), which are kept in a drawer underneath the table (see Figure 1.3). The purpose of this safety note is to ensure that the system does not pose a risk of injury to personnel during a seismic event. The system owner is OMST Engineering & Maintenance.

42 ENGINEERING↗

System Identification of Flexible Aircraft: Lessons Learned from the X-56A Phase 1 Flight Tests

The X-56A Multi-Utility Technology Testbed (MUTT) is a subscale airplane that was de-signed as an experimental flight research platform for improving aeroelastic modeling and control technologies. The Phase 1 flight tests, conducted from 2017 to 2019 at the NASA Arm-strong Flight Research Center (AFRC), included 39 flights and approximately 1000 research maneuvers, some of which demonstrated stable closed-loop flight beyond the open-loop flutter speed. This paper summarizes the system identification effort to extract nondimensional stability and control derivatives from the flight test data for constructing aeroelastic models of the flight dynamics. Topics discussed include instrumentation, experiment design, model postulation and reduction, parameter estimation, and others. Throughout the paper, unique challenges for the identification of flexible aircraft, practical aspects of the analysis, and lessons learned are presented.

Jared A Grauer↗

Heat Pipe Powered Stirling Conversion for the Demonstration Using Flattop Fission (DUFF) Test

Design concepts for small Fission Power Systems (FPS) have shown that heat pipe cooled reactors provide a passive, redundant, and lower mass option to transfer heat from the fuel to the power conversion system, as opposed to pumped loop designs typically associated with larger FPS. Although many systems have been conceptually designed and a few making it to electrically heated testing, none have been coupled to a real nuclear reactor. A demonstration test named DUFF Demonstration Using Flattop Fission, was planned by the Los Alamos National Lab (LANL) to use an existing criticality experiment named Flattop to provide the nuclear heat source. A team from the NASA Glenn Research Center designed, built, and tested a heat pipe and power conversion system to couple to Flattop with the end goal of making electrical power. This paper will focus on the design and testing performed in preparation for the DUFF test.

Fission↗

Integration Tests of the 4 kW-class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

NASAs Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This presentation presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation, open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thrusters discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

Hall Thrusters↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full Scale Alternative Catalyst Testing for Bosch Reactor Optimization

Current air revitalization technology onboard the International Space Station (ISS) cannot provide complete closure of the oxygen and hydrogen loops. This makes re-supply necessary, which is possible for missions in low Earth orbit (LEO) like the ISS, but unviable for long term space missions outside LEO. In comparison, Bosch technology reduces carbon dioxide with hydrogen, traditionally over a steel wool catalyst, to create water and solid carbon. The Bosch product water can then be fed to the oxygen generation assembly to produce oxygen for crew members and hydrogen necessary to reduce more carbon dioxide. Bosch technology can achieve complete oxygen loop closure, but has many undesirable factors that result in a high energy, mass, and volume system. Finding a different catalyst with an equal reaction rate at lower temperatures with less catalyst mass and longer lifespan would make a Bosch flight system more feasible. Developmental testing of alternative catalysts for the Bosch has been performed using the Horizontal Bosch Test Stand. Nickel foam, nickel shavings, and cobalt shavings were tested at 500 C and compared to the original catalyst, steel wool. This paper presents data and analysis on the performance of each catalyst tested at comparable temperatures and recycle flow rates.

Barton, Katherine↗

Time-Dependent Stress Rupture Strength Degradation of Hi-Nicalon Fiber-Reinforced Silicon Carbide Composites at Intermediate Temperatures

The stress rupture strength of silicon carbide fiber-reinforced silicon carbide composites with a boron nitride fiber coating decreases with time within the intermediate temperature range of 700 to 950 degree Celsius. Various theories have been proposed to explain the cause of the time-dependent stress rupture strength. The objective of this paper is to investigate the relative significance of the various theories for the time-dependent strength of silicon carbide fiber-reinforced silicon carbide composites. This is achieved through the development of a numerically based progressive failure analysis routine and through the application of the routine to simulate the composite stress rupture tests. The progressive failure routine is a time-marching routine with an iterative loop between a probability of fiber survival equation and a force equilibrium equation within each time step. Failure of the composite is assumed to initiate near a matrix crack and the progression of fiber failures occurs by global load sharing. The probability of survival equation is derived from consideration of the strength of ceramic fibers with randomly occurring and slow growing flaws as well as the mechanical interaction between the fibers and matrix near a matrix crack. The force equilibrium equation follows from the global load sharing presumption. The results of progressive failure analyses of the composite tests suggest that the relationship between time and stress-rupture strength is attributed almost entirely to the slow flaw growth within the fibers. Although other mechanisms may be present, they appear to have only a minor influence on the observed time-dependent behavior.

Progressive Failure Analysis↗

On the feasibility of closed-loop control of intra-aortic balloon pumping

A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.

Clark, J. W., Jr.↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Long Duration Testing of a Spacesuit Water Membrane Evaporator Prototype

The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi?s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 1200 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 1200 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.

Bue, Grant C.↗

Long Duration Testing of a Spacesuit Water Membrane Evaporator Prototype

The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 600 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 600 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.

Bue, Grant C.↗

Do chaotic field lines cause fast reconnection in coronal loops?

Over the past decade, Boozer has argued that three-dimensional (3D) magnetic reconnection fundamentally differs from two-dimensional reconnection due to the fact that the separation between any pair of neighboring field lines almost always increases exponentially over distance in a 3D magnetic field. According to Boozer, this feature makes 3D field-line mapping chaotic and exponentially sensitive to small non-ideal effects; consequently, 3D reconnection can occur without intense current sheets. We test Boozer's theory via ideal and resistive reduced magnetohydrodynamic simulations of the Boozer–Elder coronal loop model driven by sub-Alfvénic footpoint motions [A. H. Boozer and T. Elder, Phys. Plasmas 28, 062303 (2021)]. In this work, our simulation results significantly differ from their predictions. The ideal simulation shows that Boozer and Elder under-predict the intensity of current density due to missing terms in their reduced model equations. Furthermore, resistive simulations of varying Lundquist numbers show that the maximal current density scales linearly rather than logarithmically with the Lundquist number.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computerized design of controllers using data models

The major contributions of the grant effort have been the enhancement of the Compensator Improvement Program (CIP), which resulted in the Ohio University CIP (OUCIP) package, and the development of the Model and Data-Oriented Computer Aided Design System (MADCADS). Incorporation of direct z-domain designs into CIP was tested and determined to be numerically ill-conditioned for the type of lightly damped problems for which the development was intended. Therefore, it was decided to pursue the development of z-plane designs in the w-plane, and to make this conversion transparent to the user. The analytical development needed for this feature, as well as that needed for including compensator damping ratios and DC gain specifications, closed loop stability requirements, and closed loop disturbance rejection specifications into OUCIP are all contained in Section 3. OUCIP was successfully tested with several example systems to verify proper operation of existing and new features. The extension of the CIP philosophy and algorithmic approach to handle modern multivariable controller design criteria was implemented and tested. Several new algorithms for implementing the search approach to modern multivariable control system design were developed and tested. This analytical development, most of which was incorporated into the MADCADS software package, is described in Section 4, which also includes results of the application of MADCADS to the MSFC ACES facility and the Hubble Space Telescope.

Irwin, Dennis↗

Accident tolerant fuel test 2c (ATF-2C) irradiation test report

A fully prototypic testing platform for testing new accident tolerant fuel (ATF) designs for light water reactors has been established in the center flux trap of Idaho National Laboratory’s advanced test reactor (ATR). The irradiation experiment named ATF-2C has completed its four cycles of prototypic steady state irradiation. Irradiation conditions have been maintained via the loop 2a pressurized water coolant loop and have been monitored through in-situ instrumentation during each cycle. Power and burnup histories of each of the 18 fueled test pins has been calculated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Europa Clipper Passive Thermal Control Valve Test and Analysis

Europa Clipper spacecraft utilizes passive thermal control valves (TCV) in an active thermal control system to maintain spacecraft component temperatures within their allowable limits. The single-phase mechanically pumped fluid loop recovers heat from the electronics and uses it to maintain propulsion system warm. When excess heat is dissipated the mixing valves direct the fluid to the radiator to reject this additional heat. The loop uses two mixing TCVs placed in series to modulate fluid flow and heat rejection rate from the radiator. This paper describes the thermal and hydraulic test results for Europa Clipper engineering model (EM) mixing valves. For the first time two heritage mixing valves previously developed for the Mars Science Laboratory (MSL) were placed in series to modulate flow to the radiator from 0.1% to 95% of full flow between temperature range of 4 oC to 24 oC. Individually, each mixing valve was able to modulate the flow from 2% to 96% of full flow between the temperatures of 4 oC and 24 oC. Pressure drop was measured between 1.5 to 3 psid depending on the temperature of the mixed fluid and the opening fraction of the valves. A methodology was developed, tested, and validated to adjust the setpoints with an accuracy of 0.1 oC. The measured flow splits were corrected for the effects of impedance due to the flow meters used to measure the flow rates. Finally, flow rate to the radiator increased linearly as a function of mixed temperature for individual valves, while it increased parabolically with temperature when two mixing valves were placed in series.

Mastropietro, AJ↗

Integration Tests of the 4 kW-Class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

NASA's Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This paper presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation along with open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thruster's discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

Power Processing Unit↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

Thermal Control Systems↗