Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Fuel-Lubricant Interactions on the Propensity for Stochastic Pre-Ignition

This work explores the impact of the interaction of lubricant and fuel properties on the propensity for stochastic pre-ignition (SPI). Findings are based on statistically significant changes in SPI tendency and magnitude, as determined by measurements of cylinder pressure. Specifically, lubricant detergents, lubricant volatility, fuel volatility, fuel chemical composition, fuel-wall impingement, and engine load were varied to study the physical and chemical effects of fuel-lubricant interactions on SPI tendency. The work illustrates that at low loads, with fuels susceptible to SPI events, lubricant detergent package effects on SPI were non-significant. However, with changes to fuel distillation, fuel-wall impingement, and most importantly engine load, lubricant detergent effects could be observed even at reduced loads This suggests that there is a thermal effect associated with the higher load operation. It was hypothesized that the thermal effect was associated with lube oil nitrogenation. To test this theory, nitromethane (CH3NO2) was blended at 6.5% by volume CH3NO2 resulted in significant sensitivity to lubricant additive package effect on SPI, even at reduced loads where no lubricant sensitivity was observed without the addition of CH3NO2. The combined results highlight the interplay of fuel-lubricant interaction on SPI events, but more importantly suggest that there is the potential of a chemical interaction unique to high-load engine operation that results in reactive chemical processes, such as nitration, where lubricant chemistry becomes an active pathway for SPI activity.

33 ADVANCED PROPULSION SYSTEMS↗

Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)

The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distribution feeder simulation.

25 ENERGY STORAGE↗

An EBSD Evaluation of the Microstructure of Crept Nimonic 101 for the Validation of a Polycrystal–Plasticity Model

Nimonic 101 is one of the early nickel-based superalloys developed for the use in gas turbines. In such environments, the material is exposed to a combination of both high temperatures and mechanical loads for a long duration. Hence, thermal creep is of the utmost concern as it often limits service life. This study focuses on creep tests, carried out on Nimonic 101 at different temperatures under a constant tensile load of 735 MPa. To characterize the microstructural evolution, electron backscatter diffraction (EBSD) measurements were employed before and after loading. At higher temperatures, a significant change of the microstructure was observed. The grains elongated and aligned their orientation along the load axis. In parallel, a crystal plasticity material model has been set up in the classical large deformation framework. Modeling results are compared to the acquired EBSD data.

36 MATERIALS SCIENCE↗

Effects of the air–steam mixture on the permeability of damaged concrete

Massive concrete structures such as the containments of nuclear power plant must maintain their tightness at any circumstances to prevent the escape of radioactive fission products into the environment. In the event of an accident like a Loss of Coolant Accident (LOCA), the concrete wall is submitted to both hydric and mechanical loadings. A new experimental device reproducing these extreme conditions (water vapor transfer, 140 °C and 5 bars) is developed in the GeM Laboratory to determine the effect of the saturation degree, the mechanical loading and the flowing fluid type on the concrete transfer properties. The experimental tests show that the previous parameters significantly affect the concrete permeability and the gas leakage rate. Their evolution as a function of the mechanical loading is characterized by two phases that are directly related to concrete microstructure and crack development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Durability Testing of Biomass Based Oxygenated Fuel Components in a Compression Ignition Engine

Blending cellulosic biofuels with traditional petroleum-derived fuels results in transportation fuels with reduced carbon footprints. Many cellulosic fuels rely on processing methods that produce mixtures of oxygenates which must be upgraded before blending with traditional fuels. Complete oxygenate removal is energy-intensive and it is likely that such biofuel blends will necessarily contain some oxygen content to be economically viable. Previous work by our group indicated that diesel fuel blends with low levels (<4%-vol) of oxygenates resulted in minimal negative effects on short-term engine performance and emissions. However, little is known about the long-term effects of these compounds on engine durability issues such as the impact on fuel injection, in-cylinder carbon buildup, and engine oil degradation. In this study, four of the oxygenated components previously tested were blended at 4%-vol in diesel fuel and tested with a durability protocol devised for this work consisting of 200 hrs of testing in a stationary, single-cylinder, Yanmar diesel engine operating at constant load. Oil samples, injector spray patterns, and carbon buildup from the injector and cylinder surfaces were analyzed. It was found that, at the levels tested, these fuels had minimal impact on the overall engine operation, which is consistent with our previous findings.

09 BIOMASS FUELS↗

Durability Testing of Biomass Based Oxygenated Fuel Components in a Compression Ignition Engine

Blending cellulosic biofuels with traditional petroleum-derived fuels results in transportation fuels with reduced carbon footprints. Many cellulosic fuels rely on processing methods that produce mixtures of oxygenates which must be upgraded before blending with traditional fuels. Complete oxygenate removal is energy-intensive and it is likely that such biofuel blends will necessarily contain some oxygen content to be economically viable. Previous work by our group indicated that diesel fuel blends with low levels (<4%-vol) of oxygenates resulted in minimal negative effects on short-term engine performance and emissions. However, little is known about the long-term effects of these compounds on engine durability issues such as the impact on fuel injection, in-cylinder carbon buildup, and engine oil degradation. In this study, four of the oxygenated components previously tested were blended at 4%-vol in diesel fuel and tested with a durability protocol devised for this work consisting of 200 hrs of testing in a stationary, single-cylinder, Yanmar diesel engine operating at constant load. Oil samples, injector spray patterns, and carbon buildup from the injector and cylinder surfaces were analyzed. It was found that, at the levels tested, these fuels had minimal impact on the overall engine operation, which is consistent with our previous findings.

09 BIOMASS FUELS↗

An investigation of wear behaviors of different Monel alloys produced by powder metallurgy

In the present study, wear behaviors of Monel 400, Monel 404, Monel R-405 and Monel K-500 alloys produced by Powder Metallurgy (P/M) method were investigated. These compounds prepared from elemental powders were cold-pressed (600 MPa) and then, sintered at 1150°C for 2 hours and cooled down to the room temperature in furnace environment. Monel alloys produced by the P/M method were characterized through scanning electron microscope (SEM+EDS), X-ray diffraction (XRD), hardness and density measurements. In wear tests, standard pin-on-disk type device was used. Specimens produced within four different Monel Alloys were tested under 1ms{sup −1} sliding speed, under three different loads (20N, 30N and 40N) and five different sliding distances (400-2000 m). The results show that Monel Alloys have γ matrix and that Al{sub 0,9}Ni{sub 4,22} intermetallic phase was formed in the structure. Also, the highest hardness value was measured with the Monel K-500 alloy. In wear tests, the maximum weight loss according to the sliding distance, was observed in Monel 400 and Monel 404 alloys while the minimum weight loss was achieved by the Monel K-500 alloy.

36 MATERIALS SCIENCE↗

Damage mechanisms in PBT-GF30 under thermo-mechanical cyclic loading

The scope of this paper is the investigation of damage mechanisms at microscopic scale on a short glass fiber reinforced polybutylene terephthalate (PBT-GF30) under thermo-mechanical cyclic loading. In addition the principal mechanisms are verified through micro mechanical FE models. In order to investigate the fatigue behavior of the material both isothermal strain controlled fatigue (ISCF) tests at three different temperatures and thermo-mechanical fatigue (TMF) tests were conducted on plain and notched specimens, manufactured by injection molding. The goal of the work is to determine the damage mechanisms occurring under TMF conditions and to compare them with the mechanisms occurring under ISCF. For this reason fracture surfaces of TMF and ISCF samples loaded at different temperature levels were analyzed using scanning electron microscopy. Furthermore, specimens that failed under TMF were examined on microsections revealing insight into both crack initiation and crack propagation. The findings of this investigation give valuable information about the main damage mechanisms of PBT-GF30 under TMF loading and serve as basis for the development of a TMF life estimation methodology.

36 MATERIALS SCIENCE↗

Study on Electrostatic Separation of Quinoline Insolubles from Coal Tar Pitch

The feasibility of electrical separation in the removal of quinoline insoluble (QI) particles from coal tar pitch (CTP) was experimentally investigated. QI particle involvement prohibits the effective fabrication of high-quality value-added products, such as carbon fibers, from CTP. A substantial and sustainable CTP market exists around the world; therefore, a strong incentive exists to develop a viable technical approach to effectively and economically remove QI particles from CTP. The electrical separation method shows promise to achieve this technical goal (Cao et al., 2012). Even with the given setup (wire- cylinder adapted), critical issues remain to be addressed for this method to be applicable to the CTP: (1) identifying the wash oil used in the original QI separation, (2) understanding the mechanism of QI separation, (3) characterizing the deposit, and (4) identifying the QI. This study integrated a set of experimental and analysis techniques into the electrical separation tests to address the aforementioned issues. Key findings are as follows: 1. Electric current responses: • The electric current level of the CTP–wash oil solution reported by Cao et al. (2012) can be attained by using a mixture of 25% quinoline and 75% toluene for the CTPs examined in this study under the same electrical load condition. • The electric current tends to decrease during the test period because of the decreasing number of charged particles. • The reversed field corresponded to the configuration of electrostatic precipitation for positive corona discharge. The high electric field can result in dielectric breakdown and lead to an abrupt current surge. 2 Deposit response and solvent candidates: • Deposit of particles in CTP mixture can be effectively implemented in a wire-cylinder configuration as proposed and examined in this study. • Deposit depends on the solvents. Among the solvents tested, two- and three-part solvents that included quinoline and ethanol (i.e., 25% quinoline and 75% toluene; 50% quinoline and 50% toluene; and 33% wash oil, 33% BTX, and 34% ethanol) produced the highest deposit weight. • The deposit process examined in this study is derived from the charged particles. An appreciable relation exists between deposit weight and electric charge. 3. QI removal efficiency (RE): • The RE of the electrostatic separation can reach as high as 76.2% for Carbores, and 61.6% for Koppers. • The RE can be further enhanced if the field level increases from 0.16 kV/mm that was used in the current study to 0.23 kV/mm, according to the relation established between the RE and the electric field. 4. Testing of the modeling system: • The motion of particles is originally driven by the charge-based electric force in the cases tested. The solid particle separation mechanism is similar to that of QI deposition in CTP. • The mechanical movement of solid particles can be strongly affected by the gravitational and viscous forces in the electric field. 5. EDS analysis and chemical compositions: • The main chemical composition of deposit QI matches that of as-prepared CTP QI. The deposit QI is derived from the same group of the CTP QI. • In addition to carbon, the QI contains oxygen, sodium, aluminum, silicon, iron, and sulfur. The work for the near future is also discussed.

01 COAL, LIGNITE, AND PEAT↗

Use of Adaptive Injection Strategies to Increase the Full Load Limit of RCCI Operation

Dual-fuel combustion using port-injection of low reactivity fuel combined with direct injection (DI) of a higher reactivity fuel, otherwise known as reactivity controlled compression ignition (RCCI), has been shown as a method to achieve low-temperature combustion with moderate peak pressure rise rates, low engine-out soot and NO x emissions, and high indicated thermal efficiency. A key requirement for extending to high-load operation is moderating the reactivity of the premixed charge prior to the diesel injection. One way to accomplish this is to use a very low reactivity fuel such as natural gas. In this work, experimental testing was conducted on a 13 l multicylinder heavy-duty diesel engine modified to operate using RCCI combustion with port injection of natural gas and DI of diesel fuel. Engine testing was conducted at an engine speed of 1200 rpm over a wide variety of loads and injection conditions. The impact on dual-fuel engine performance and emissions with respect to varying the fuel injection parameters is quantified within this study. The injection strategies used in the work were found to affect the combustion process in similar ways to both conventional diesel combustion (CDC) and RCCI combustion for phasing control and emissions performance. As the load is increased, the port fuel injection (PFI) quantity was reduced to keep peak cylinder pressure (PCP) and maximum pressure rise rate (MPRR) under the imposed limits. Overall, the peak load using the new injection strategy was shown to reach 22 bar brake mean effective pressure (BMEP) with a peak brake thermal efficiency (BTE) of 47.6%.

Hanson, Reed↗

Strength Properties of Aged Poled Lead Zirconate Titanate Subjected to Electromechanical Loadings

Electric field and aging time are two important factors that affect the mechanical strength and long-term reliability of lead zirconate titanate or PZT actuators. In the present work, a commercial PZT-5A aged four years was examined using ball-on-ring (BoR) mechanical testing under coupled electric fields. The electric field range of -3E{sub c} to +3E{sub c} (E{sub c}, coercive electric field) was studied (i.e., -3E{sub c}, -E{sub c}, 0, +E{sub c}, +2E{sub c}, and +3E{sub c}) with a controlled electric loading path. A Weibull distribution was used to interpret the mechanical strength data. With an electric field preloaded from 0 to -3E{sub c}, it was found that subsequent increases in the electric field resulted in an asymmetrical V-shaped curve of mechanical strength against the electric field. The bottom of the V curve was located near the zero electric field level. Microscopy analysis showed that pores were the strength limiter for the tested PZT under electromechanical loadings.

36 MATERIALS SCIENCE↗

Melting Hanford LAW into Iron-Phosphate Glass in a CCIM

A vitrification test has been conducted using the cold crucible induction melter (CCIM) test system at the Idaho National Laboratory. The test was conducted to demonstrate the vitrification of a Hanford low activity waste (LAW) that contains relatively large amounts of sulfate and sodium, compared to other radioactive Hanford waste streams. The high sulfate content limits the potential loading of this waste stream in conventional borosilicate glass, so this test demonstrated how this waste stream could be vitrified in an iron-phosphate glass that can tolerate higher levels of sulfate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BOP-301 and BOP-302R: Test Definitions and Analyses

Following the conclusion of the International Atomic Energy Agency (IAEA) coordinated research project (CRP) on analysis of two EBR-II tests, Argonne has continued its EBR-II analysis with additional tests from the Shutdown Heat Removal Test (SHRT) series. The tests selected for this follow-up analysis are BOP-301 and BOP-302R, two unprotected loss of heat of sink tests in which the intermediate sodium pump tripped without scramming the control rods or tripping the primary pumps. The IAEA CRP focused on the SHRT-17 and SHRT-45R tests, the most severe protected and unprotected loss of flow tests performed during the SHRT series. With the primary pumps tripping, flow rates decreased to levels where flowmeter uncertainty was very high. Accurately capturing the progressions of the two tests despite this uncertainty was one of the key modeling and simulation challenges during the CRP. BOP-301 and BOP-302R were selected because the primary sodium pumps did not trip for those tests. Primary flow rate measurements are known with greater certainty. Power and temperature discrepancies can be explored without concern that flow predictions match test measurements but not the actual flow rates from the tests. These two tests were performed during the same test window as SHRT-45R and had the same core load configuration. Therefore, core models created for analysis of SHRT-45R were easily adapted for analysis of BOP-301 and BOP-302R. Another reason for analyzing BOP-301 and BOP-302R is to analyze tests in which the core inlet temperature changed significantly, which did not occur during the loss of flow tests. The transient progression of the unprotected SHRT-45R test was driven by a decreasing core flow rate while the core inlet temperature remained relatively constant. For the BOP tests, the transient progression was driven by an increasing core inlet temperature while the core flow rate was stable. This report defines the BOP-301 and BOP-302R tests and provides a selection of measured test data. Initial predictions from SAS4A/SASSYS-1 simulations of these tests are then presented. Following these simulations, additional analysis was performed with the Dakota uncertainty quantification and optimization toolkit to determine which parameters have the greater impact on the transient results and the optimal values of the most important parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rotational Augmentation Disparities in the MEXICO and UAE Phase VI Experiments: Preprint

Wind turbine structures and components suffer excessive loads and premature failures when key aerodynamic phenomena are not well characterized, fail to be understood, or are inaccurately predicted. Turbine blade rotational augmentation remains incompletely characterized and understood, thus limiting robust prediction for design. Pertinent rotational augmentation research including experimental,theoretical, and computational work has been pursued for some time, but large scale wind tunnel testing is a relatively recent development for investigating wind turbine blade aerodynamics. Because of their large scale and complementary nature, the MEXICO and UAE Phase VI wind tunnel experiments offer unprecedented synergies to better characterize and understand rotational augmentation of bladeaerodynamics.

17 WIND ENERGY↗

Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis

Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.

08 HYDROGEN↗

Geometry Optimization of Cable-Based Actuation for Small-Scale Model Testing of a Floating Marine Turbine: Preprint

This research aims to apply combined wave and tidal current loads to a small-scale floating marine current turbine in a wave tank, where an actuation system applies hydrodynamic and mooring forces on the hardware based on results from a simulation. We use a real-time hybrid test setup with physical wave forcing from the wave tank and simulated current and mooring forces implemented through a tensioned cable array. For this paper, we developed an optimization algorithm that adjusts the hardware geometry of the cable array to achieve more efficient tension allocation across the cables for the loads that need to be actuated. By adjusting the points where the cables are attached to the floating platform and the angles between the platform and the winches, an optimal cable geometry can be found to minimize tension variations in the lines, maintain the desired pretension, and prevent excessive tensions. We present the optimization problem formulation, the actuation system evaluation approach, and optimization results that show effective cable actuation setups that are being considered for implementation in the wave tank tests.

cable-based actuation↗

Crack Growth Rate and Large Plate Demonstration of Chloride-induced Stress Corrosion Cracking in Spent Nuclear Fuel Storage Canisters

This report describes the body of work involving testing and analyses performed in FY18 and FY19 at the Savannah River National Laboratory and at Korea University to determine chloride-induced stress corrosion crack (CISCC) growth rates in weldments of austenitic stainless steel plate material. The primary work involved: several separate crack growth rate test campaigns with new testing setups using laboratory-scale corrosion specimens; analyses to estimate the stress intensity factors for flaws postulated to be present in the residual stress fields of axial and circumferential weldments in a prototypic dry storage canister; and establishment of a “large plate” (approximately 51×46 cm with thickness 16 mm and weight about 30 kg) CISCC test that uses a plate with a circumferential weldment harvested from the Sandia National Laboratories’ full-size mockup dry storage canister. The tests for crack growth rate were conducted on ASTM E1861 bolt-load compact tension specimens in a setup designed to allow initially dried salt deposits to deliquesce and infuse the brine to the crack front under conditions relevant to the canister storage environments (e.g., temperature and humidity). The crack growth rate test results matched previous experimental data in the open literature. These literature data had been compiled by SNL and EPRI to develop a temperature-dependent (K-insensitive) crack growth rate model to support flaw disposition in the ASME Boiler and Pressure Vessel Section XI Code Case N-860, “Examination Requirements and Acceptance Standards for Spent Nuclear Fuel Storage and Transportation Containment Systems.” The knowledge of the salt, temperature, humidity conditions for CISCC including the threshold stress intensity factor, $K_{ISCC}$, were used to setup the large plate test in which a set of partthrough- wall and through-wall electrical discharge machined (EDM) defects were positioned in the weld residual stress field of the welded plate material from the mockup canister. A salt solution was applied to this plate specimen with an air-brush spray, then dried, and then exposed to a constant 75% RH condition at an ambient room temperature of 22 °C. The salt loading and environmental condition is expected to be aggressive to cause CISCC. The visual results at the surface of the plate show corrosion product staining (brown rust appearance) but with no CISCC emanating from the machined notches after approximately 5 months exposure to date. The plate test will continue in FY20 and phased-array ultrasonic testing and other NDE techniques will be applied to identify and characterize CISCC that may emanate from the machined defects. The notches and any CISCC from them will be sectioned at the conclusion of the test to verify NDE characterization, and to develop effective through-wall crack growth rates from cracks that would likely be branched.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗