Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Effects of Riser Diameter on Solids Holdup and Particle Velocity Profiles in Circulating Fluidized Bed Riser Systems

Tests were performed in a 0.1-m diameter small circulating fluidized bed (SCFB) and 0.3 m diameter cold flow circulating fluidized bed (CFCFB) riser systems located at the National Energy Technology Laboratory (NETL) to study the effects of riser diameter on the riser hydrodynamics. These tests were performed at solids circulation rates of G s = 20 and 75 kg/m 2 s and superficial gas velocities of U g = 5.8 and 6.5 m/s using high-density polyethylene (HDPE) pellets with a density of 0.863 g/cm 3 , particle size range of 600–1400 µm (with a Sauter mean diameter of 871 µm, placing them in the Geldart B classification). Comparisons of riser axial pressure and solids fraction profiles, radial particle velocity profiles, and radial profiles of higher statistical moments and select chaos analysis parameters were considered. The results showed that for a given U g and G s , the smaller diameter riser exhibited characteristics associated with more dilute solids flow than that observed in the larger diameter riser. Additionally, the larger diameter riser exhibited a downward flow of solids near the wall under all test conditions, whereas the smaller diameter riser data exhibited little or no indications of solids downflow near the wall. Overall, these findings suggest that, from an industrial standpoint, a direct scaleup of small-scale tests cannot readily be accomplished as the solids holdup and the solids velocity profiles in small units (those normally tested in the laboratory) are not similar to those of large units and the performance of large units can therefore not be predicted from small-scale tests.

42 ENGINEERING↗

PiTS-1: Carbon Partitioning in Loblolly Pine after 13C Labeling and Shade Treatments

The Partitioning in Trees and Soil (PiTS) task was established with the objective of improving the C partitioning routines in existing ecosystem models by exploring mechanistic model representations of partitioning tested against field observations. We used short-term field manipulations of C flow, through 13CO2 labeling, canopy shading and stem girdling, to dramatically alter C partitioning, and resultant data are being used to test model representation of C partitioning processes in the Community Land Model (CLM4 or CLM4.5). The research was conducted on individual trees within a small existing stand of planted Pinus taeda L.(loblolly pine) on the University of Tennessee Forest Resources Research and Education Center in Oak Ridge, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Geothermal Energy for New Mexico: Assessment of Potential and Exploratory Drilling

This report summarizes the drilling operations and subsequent interpretation of thermal and geochemical data from the New Mexico Tech NMT-2GT (OSE RG- 05276 POD) test well. This slim hole was drilled along an elongate heat-flow anomaly at the base of the Socorro Mountains to better assess the geothermal resource potential (Socorro Peak geothermal system) on the western side of the New Mexico Tech campus in Socorro, New Mexico. The reservoir depth, hydraulic properties, temperature and chemistry were unknown prior to drilling. The purpose of the NMT-2GT (OSE RG-05276 POD) well was to explore the feasibility of providing geothermal fluids for a proposed district space heating system on the New Mexico Tech campus. With DOE cost over runs funds we completed NMT-2GT to a depth of 1102 feet at the Woods Tunnel drill site. Temperatures were nearly constant (41 oC ) between a depth of 1102 feet. Above this isothermal zone, a strong temperature gradient was observed (210 oC /km) beneath the water table consistent with vertical convective heat transfer. The existence of a groundwater upflow zone was further supported by measured vertical hydraulic head measurements which varied between about 258 feet at the water table to 155 feet at a depth of 1102 feet yielding a vertical hydraulic a gradient of about 0.1. If the upflow zone is 1 km deep, then a vertical flow rate is about 0.6 m/yr could have produced the observed curvature in the thermal profile. This would suggest that the deep bedrock permeability is about 20 mD. This is much lower than the permeability measured in a specific capacity aquifer test completed in 2009 within fracture Paleozoic sandstones near the water table (3000 D). Flow rates measured during drilling were measured using a v-notch weir. Flow rates were consistently around 1000 gpm. While the temperatures are lower than we had anticipated, this geothermal resource can still be developed to heat the NM Tech campus using heat pump technology.

15 GEOTHERMAL ENERGY↗

Flow Measurements of Methane-Fueled Rotating Detonation Combustion

Time-resolved particle image velocimetry (PIV) is applied to the flow field at the immediate exit of a rotating detonation combustor (RDC) operating on methane fuel and oxygen-enriched air. The detailed experimental results, which allow for the quantification of the periodic flow field, are believed to be the first such measurements acquired for a RDC. A thorough understanding of the velocity flow field exiting the combustor is important to develop future rotating detonation engine (RDE) design, as well as to successfully implement the flow conditioning devices to power generating turbine hardware located downstream. In this study, multiple PIV tests were conducted and a test case with over 16,000 consecutive image pairs acquired at a PIV framing rate of 30 kHz is analyzed in detail, and is supplemented with another test case to verify the repeatability of the measurements. Results are discretized into a two-dimensional flow field to reveal the significant insights to characterize the cyclical velocity fluctuations. While the flow field is primarily axial, a significant circumferential velocity component is also present. Key attributes of the velocity flow field are observed to be repeated from cycle-to-cycle. The codependency of the fluctuations in axial and circumferential velocity components are investigated, as is the relationship between velocity magnitude and flow orientation. At discrete measurement locations, the Fourier analysis of PIV data is used to reconstruct the cyclical variation of velocity components with respect to the phase angle.

03 NATURAL GAS↗

In-situ investigation water distribution in polymer electrolyte fuel cell using neutron radiography

This paper investigates the water content within operating polymer electrolyte membrane (PEM) fuel cells using neutron radiography. We consider fuel cells with various PTFE loadings in their gas diffusion layers (GDL) and microporous layers (MPL), and examine the impacts of MPL/GDL properties on the liquid water behavior and fuel cell performance. Fuel cells are tested at both dry and fully hydrated conditions with different serpentine flow fields. Water contents in the projected areas of channel and land regions are probed. The fuel cell may be subject to more flooding at low current-density operation. Both MPL and GDL wetting properties have substantial impacts on the water content in fuel cell. Cell performance also varies on different scenarios of the MPL/GDL wetting properties. A quad-serpentine channel flow field exhibits higher water content without remarkable change in performance at low current densities. Liquid water profile along the channel is presented and on-set clearly indicated.

30 DIRECT ENERGY CONVERSION↗

Gyroaverage effects on nontwist Hamiltonians: separatrix reconnection and chaos suppression

A study of nite Larmor radius (FLR) eects on E B test particle chaotic transport in non- monotonic zonal ows with drift waves in magnetized plasmas is presented. Due to the non- monotonicity of the zonal ow, the Hamiltonian does not satisfy the twist condition. The electro- static potential is modeled as a linear superposition of a zonal ow and regular neutral modes of the Hasegawa-Mima equation. FLR eects are incorporated by gyro-averaging the EB Hamiltonian. It is shown that there is a critical value the Larmor radius for which the zonal ow transitions from a prole with one maximum to a prole with two maxima and a minimum. This bifurcation leads to the creation of additional shearless curves and resonances. The gyroaveraged nontwist Hamiltonian exhibits complex patterns of separatrix reconnection. A change in the Larmor ra- dius can lead to heteroclinic-homoclinic bifurcations and dipole formation. For Larmor radii for which the zonal ow has bifurcated, double heteroclinic-heteroclinic, homoclinic-homoclinic and heteroclinic-homoclinic topologies are observed. It is also shown that chaotic transport is typically reduced as the Larmor radius increases. Poincare sections shows that, for large enough Larmor radius, chaos can be practically suppressed. In particular, small changes on the Larmor radius can restore the shearless curve.

Del-Castillo-Negrete, Diego B↗

High fidelity simulation and validation of crossflow through a tube bundle and the onset of vibration

Flow induced vibrations can be detrimental to all manner of engineering applications with fluid flow. Heat exchangers with bundles of thin tubes experiencing a crossflow are especially susceptible to the unexpected onset of vibration. Heat-exchanger design necessarily involves extensive modeling and testing to ensure that significant vibrations cannot develop for any expected flow conditions. A properly validated numerical simulation can work in conjunction with physical experiments to identify problematic vibrations and allow for rapid iteration of design at relatively low expense. A high-fidelity fluid–structure interaction code has been developed by fully coupling CFD LES/DNS code Nek5000 and CSM code Diablo. The coupled code is used to simulate crossflow through a tube bundle in a geometry recreated after a physical experiment. Validation against this experiment involves comparing the amplitude and frequency spectrum for three different flow velocities. The velocities compared straddle the onset of large magnitude vibrations. The simulation accurately captures the onset of the vibrations with a marginally lower predicted frequency of vibration. When the onset velocity is compensated for the difference in natural frequency, the simulation results closely match the experiment. Finally, the continuous nature of the simulation measurements helps illustrate the fluid mechanics behind the pin motion and reveals the front to back propagation of the vibrations as the fluid velocity increases.

42 ENGINEERING↗

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Fidelity Simulation and Validation of Crossflow through a Tube Bundle and the Onset of Vibration

Flow induced vibrations can be detrimental to all manner of engineering applications with fluid flow. Heat exchangers with bundles of thin tubes experiencing a crossflow are especially susceptible to the unexpected onset of vibration. Heat-exchanger design necessarily involves extensive modeling and testing to ensure that significant vibrations cannot develop for any expected flow conditions. A properly validated numerical simulation can work in conjunction with physical experiments to identify problematic vibrations and allow for rapid iteration of design at relatively low expense. A high-fidelity fluid-structure interaction code has been developed by fully coupling CFD LES/DNS code Nek5000 and CSM code Diablo. The coupled code is used to simulate crossflow through a tube bundle in a geometry recreated after a physical experiment. Validation against this experiment involves comparing the amplitude and frequency spectrum for three different flow velocities. The velocities compared straddle the onset of large magnitude vibrations. The simulation accurately captures the onset of the vibrations with a marginally lower predicted frequency of vibration. When the onset velocity is compensated for the difference in natural frequency, the simulation results closely match the experiment. The continuous nature of the simulation measurements helps illustrate the fluid mechanics behind the pin motion and reveals the front to back propagation of the vibrations as the fluid velocity increases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of electric vehicles on the IEEE 34 node distribution infrastructure

With the growing penetration of the electric vehicles to our daily life owing to their economic and environmental benefits, there will be both opportunities and challenges to the utilities when adopting plug-in electric vehicles (PEV) to the distribution network. In this study, a thorough analysis based on real-world project is conducted to evaluate the impacts of electric vehicles infrastructure on the grid relating to system load flow, load factor, and voltage stability. IEEE 34 node test feeder was selected and tested along with different case scenarios utilizing the electrical distribution design (EDD) software to find out the potential impacts to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fabrication Status of ITER Central Solenoid Modules

The fabrication of the modules for the ITER Central Solenoid (CS) is in progress at General Atomics (GA) in Poway, California, USA. This purpose built facility has been established with the requisite tools and machines to fabricate the seven 110 tonne CS modules (six required plus one spare). GA’s project responsibility is completing the fabrication design, developing and qualifying the fabrication processes and tools, fabricating the seven modules, and testing the modules at 4.5 K with full current. The current schedule has the first module’s completing fabrication in 2018 followed by electrical and full current testing. Upon completion of testing, the modules will be shipped to the ITER site for assembly into the CS stack. GA has co mpleted the fabrication of a qualification coil, simulating all of the processes and exercising all of the tooling required to fabricate a production module. After completion, the qualification coil underwent a cool down cycle to 4.5K which served as the final commissioning step of the helium cooling system on the parallel flow paths of a module. In addition, other final test station systems and procedures were simulated to verify their functionality including simulated critical current sharing temperature (Tcs) measurements, DC switch operation to dump the energy from the coil, and a helium leak test on the coil at <10K. After warming the coil, Paschen tests were repeated prior to the coil being dissected to evaluate the quality of the vacuum pressure impregnation (VPI). Dissection is scheduled for early spring 2018 and the results showed full resin impregnation of all areas. In the production and testing of the qualification coil, many lessons were learned and the improvements incorporated into the module fabrication processes. GA currently has five production modules in fabrication, at different stages in the process. The first module is nearly ready for vacuum pressure impregnation. The second and third modules are currently in the insulation process and the 7 pancakes of the forth module are being joined together into a 110 tonne module. Module 5 is currently being wound. The qualification coil has been completed and dissected to evaluate the VPI. A description of the VPI process is provided. To verify the turn insulation of a module, unique impulse testing methods were developed to test the insulation between the 560 turns of a module. These methods are reported in this paper.

Smith, J.↗

Droplet Entrainment in Steam Supply System of Water-Cooled Small Modular Reactors: Experiment and Modeling Approaches

Droplet entrainment in steam-flow is a prominent phenomenon that needs adequate safety and risk analysis of postulated transient and accident scenarios—including experimental investigation and representative modeling and simulation (M&S)—for small modular reactor (SMR) system design and demonstration. This study identifies knowledge gaps by evaluating experimental and computational fluid dynamics modeling approaches to support early-stage reactor system design, testing, and model evaluation. Previous studies reported in the literature for steam-flow entrainment primarily focused on gigawatt capacity pressurized water reactor (PWR) systems. However, entrainment phenomena are even more prominent for PWR-type SMRs due to their more compact integrated designs, which need further research and development. To fill the research gaps, this study provides insight by specifying the phenomena of interest by leveraging the lessons learned from past research, adopting advanced M&S techniques and advanced instrumentation and control. The findings and recommendations are applicable for evaluating steam-flow entrainment models and for designing integral effect test and separate effect test facilities for gaining reactor design approvals.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predicting octane number from microscale flame dynamics

The standard method for measuring the octane number of fuels requires large sample volumes (~1L) and access to a Cooperative Fuel Research (CFR) engine. This method reliably quantifies the knock resistance of fuels in spark ignition engines, however the large sample volume requirement prevents testing of new experimental fuels (often produced in quantities of just ~1 mL), and the large equipment size impedes mobile, decentralized testing of remote fuel supplies. When direct measurements of octane number are impractical, other methods are needed. Micro flow reactors have shown promise in measuring ignition characteristics that are sensitive to octane number, and they are compact and operate on small volumes (~1 mL). This study uses simulations to demonstrate that measurements of the unsteady flame dynamics in a micro flow reactor can provide valuable data for accurate octane number predictions. Simulations of the flow reactor are used to obtain ignition characteristics for over 200 ethanol-toluene primary reference fuels (ETPRF) and 21 biofuel blends. A feed forward neural network is trained using the micro flow reactor ignition characteristics, fuel properties, and known research octane number (RON) and motor octane number (MON) for the ETPRF fuels. Here, the neural network is able to predict the RON and MON of the biofuel blends to within 2 octane number on average. Prediction results are compared to other methods available in the literature. Additional neural network models are trained that show improved prediction accuracy as additional fuel training data becomes available.

02 PETROLEUM↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Numerical Modeling of Gas-Liquid Compressible Pipe Flow Based on the Theory of Thermodynamically Compatible Systems

Based on the theory of thermodynamically compatible systems, we formulate the governing equations of a gas-liquid compressible pipe flow and develop the Runge–Kutta–TVD and Runge–Kutta–WENO high accuracy methods. The computational model is used to solve a series of test cases demonstrating its efficiency and capability to be applied to slug flows modeling.

42 ENGINEERING↗

Assessing Stainless Steel Compatibility in Flowing FLiBe Salt

To address the considerable interest in LiF-BeF 2 (FLiBe) compatibility for fission and fusion reactor applications, static and flowing compatibility experiments were conducted to assess the compatibility with type 316H stainless steel. In static testing at 550° and 650 °C, small mass changes were measured and posttest characterization of the FLiBe showed increased levels of Fe, Cr, Ni and Mn in the salt. Adding Be in the static salt test reduced the dissolution of Fe and Ni. Further, an initial assessment of mass transfer in flowing FLiBe without a Be addition was conducted using a monometallic 316H thermal convection loop (TCL) operated for 1000 h with a peak temperature of 650 °C. Similar to prior results in flowing FLiNaK salt, the 316H specimens exhibited small mass losses in the hot leg. Posttest characterization of the 316H specimens suggested Cr surface depletion in the hot and cold legs and possibly Fe deposition in the cold leg. To further understand this behavior, Cr and Fe dissolution was measured in static FLiBe at 550–650 °C.

316H stainless steel↗

High temperature thermal and mechanical stability of high-strength nanotwinned Al alloys

Al alloys have widespread applications, but often suffer from low yield strength. Recently, nanotwinned Al-Fe solid solution alloys have shown high flow stress (>1.5 GPa), ascribed to nanograins with abundant incoherent twin boundaries and solute-stabilized 9R phase. However, the high temperature mechanical behaviors of high-strength twinned Al-Fe alloys remain unknown. In this study, we show that nanotwinned microstructures are stable up to 280 °C, followed by recrystallization at 300 °C. In-situ uniaxial compression tests in a scanning electron microscope show that the nanotwinned Al alloys retain their high flow stress of ~1.3 GPa when tested up to 200 °C, and substantial softening occurs at a test temperature of 300 °C. This work reveals the superb thermal stability and high temperature mechanical behaviors of the nanotwinned Al-Fe alloys, and offers a new perspective to design future strong and thermally stable nanostructured Al alloys.

36 MATERIALS SCIENCE↗