Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “elevation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Elevation changes near the San Gabriel Fault, Southern California

Analysis of repeated leveling observations in the vicinity of the San Gabriel Fault in Southern California indicate subsidence immediately south of the Fault relative to points to the north, south and east. These observations were previously interpreted as reflecting tectonic motions associated with either the 'Palmdale Bulge' or with preseismic effects of the San Fernando earthquake. Relative subsidence between 1953 and 1964 reaches approximately 9 cm and extends over a distance of more than 20 km. Subsidence occurs directly above the Saugus aquifer and shows a temporal correlation with the history of water level decline within the aquifer. The degree of subsidence of individual benchmarks is roughly proportional to the product of aquifer thickness and water level decline at the location of the benchmarks. Thses observations strongly suggest that movements of the surface near the San Gabriel Fault, previously inferred to be of tectonic origin, actually result from near surface sediment compaction within the Saugus basin.

Reilinger, R.↗

MLS vertical guidance and navigation for a STOL airplane landing on an elevated STOLport

In contrast to CTOL landing operations, STOL airplanes landing on short STOLport runways typically begin the flare maneuver before reaching the runway surface. Vertical guidance procedures were developed to allow an autoland flight control system for a STOL airplane to use Microwave Landing System (MLS) signals as altitude and sink rate references for flare initiation, with a transition to radar altimeter after the airplane is over the runway. The implementation has minimum impact on the control system and landing performance. Data are presented which show validation of the concepts in a simulator.

Warner, D. N., Jr.↗

Elevation of a cane-growing area of the state of Sao Paulo using LANDSAT data

Images at a scale of 1:250.000 were visually interpreted for identification and area estimates of sugar cane plantations in Sao Paulo. The basic criteria for crop identification were the spectral characteristics of channels 5 and 7 and their temporal variations observed from different LANDSAT passes. Using this technique, it was possible to map the sugar cane areas as well as the sugar cane already harvested. An area of 801,950 hectares was estimated within the study area. The confidence interval of correct classification ranged from 87.11% to 94.71%.

Dejesusparada, N.↗

Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

Chapman, P.↗

Microstructural effects on the room and elevated temperature low cycle fatigue behavior of Waspaloy

Longitudinal specimens of Waspaloy containing either coarse grains with small gamma or fine grains with large gamma were tested in air at a frequency of 0.33 Hz or 0.50 Hz. The coarse grained structures exhibited planar slip on (III) planes and precipitate shearing at all temperatures. Cracks initiated by a Stage 1 mechanism and propagated by a striation forming mechanism. At 700 C and 800 C, cleavage and intergranular cracking were observed. Testing at 500 C, 700 C, and 800 C caused precipitation of grain boundary carbides. At 700 C, carbides precipitated on slip bands. The fine grained structures exhibited planar slip on (111) planes. Dislocations looped the large gamma precipitates. This structure led to stress saturation and propagation was observed. Increasing temperatures resulted in increased specimen oxidation for both heat treatments. Slip band and grain boundary oxidation were observed. At 800 C, oxidized grain boundaries were cracked by intersecting slip bands which resulted in intergranular failure. The fine specimens had crack initiation later in the fatigue life, but with more rapid propagation crack propagation.

Lerch, B. A.↗

Failure mechanisms of thermal barrier coatings exposed to elevated temperatures

The failure of a ZrO2-8%Y2O3/Ni-14% Al-0.1% Zr coating system on Rene 41 in Mach 0.3 burner rig tests was characterized. High flame and metal temperatures were employed in order to accelerate coating failure. Failure by delamination was shown to precede surface cracking or spalling. This type of failure could be duplicated by cooling down the specimen after a single long duration isothermal high temperature cycle in a burner rig or a furnace, but only if the atmosphere was oxidizing. Stresses due to thermal expansion mismatch on cooling coupled with the effects of plastic deformation of the bond coat and oxidation of the irregular bond coat are the probable life limiting factors. Heat up stresses alone could not fail the coating in the burner rig tests. Spalling eventually occurs on heat up but only after the coating has already failed through delamination.

Miller, R. A.↗

Electrical conductivity and electron-spin resonance in oxidatively stabilized polyacrylonitrile subjected to elevated temperature

Electrical conductivity and electron spin resonance measurements are presented for oxidatively stabilized polyacrylonitrile (PAN) fibers subjected to heat treatment at temperatures ranging from 700 to 950 K. Conductivity measurements made at temperatures between 77 and 523 K reveal that PAN fibers heat treated in vacuum behave as semiconductors, with a room-temperature conductivity dominated by the contributions of impurity states, with an activation energy of 88 kcal/mole. A decrease in conductivity is observed upon air which is attributed to a decrease in the electron-phonon scattering time. ESR spectra indicate that conducting pathways having metallic properties are formed at temperatures as low as 715 K, although the contribution of these pathways to the room-temperature conductivity is extremely small next to the contribution of localized spin centers.

Lerner, N. R.↗

Acoustical measurements of vibrational relaxation in moist N2 at elevated temperatures

Sound absorption measurements are conducted by the resonant tube technique to study vibrational relaxation in moist N2 at 301, 343, and 387 K. Analysis of the data shows that improved measurement accuracy at the higher temperatures establishes vibrational-vibrational energy transfer as the operative relaxation path for the de-excitation of N2 by H2O beyond the uncertainty of experimental error. The best-fitted temperature dependence of the vibrational-vibrational rate constant is given, noting that the expression is consistent with seven independent sets of both acoustical and nonacoustical data.

Zuckerwar, A. J.↗

A study of persistent elevated pollution episodes in the northeastern United States

To examine chemical transformation within stagnant air masses and the atmospheric processes acting upon such air masses, the United States EPA sponsored a study in the summer of 1980 in the northeastern region of the country. Ten research aircraft and several mobile and stationary surface monitoring platforms participated in an intensive measurement program between 16 July and 15 August 1980. Pollutants of interest included SO2, NO, NO(x), HC, O3, sulfate, nitrate, and aerosols in general. This paper summarizes the activities of these research aircraft. Three aircraft and one helicopter logged a total of 353 flight hours during 100 missions in the program. The flight patterns and data collected for each mission are documented. This summary will allow scientists who are interested in this data base to identify subsets of the data for model development.

Vaughan, W. M.↗

Wind tunnel tests of Space Shuttle external tank insulation material in the aerothermal tunnel at elevated (1440 deg F) total temperatures

Tests of the space shuttle external tank foam insulation were conducted in the von Karman Gas Dynamics Facility Tunnel C. For these tests, Tunnel C was run at Mach 4 with a total temperature of 1440 F and a total pressure which varied from 30-100 psia. Cold wall heating rates were changed by varying the test article support wedge angle and by adding and removing a shock generator or a cylindrical protuberance. Selected results are presented to illustrate the test techniques and typical data obtained.

Hartman, A. S.↗

Experimental verification of the Neuber relation at room and elevated temperatures

The accuracy of the Neuber equation at room temperature and 1,200 F as experimentally determined under cyclic load conditions with hold times. All strains were measured with an interferometric technique at both the local and remote regions of notched specimens. At room temperature, strains were obtained for the initial response at one load level and for cyclically stable conditions at four load levels. Stresses in notched members were simulated by subjecting smooth specimens to he same strains as were recorded on the notched specimen. Local stress-strain response was then predicted with excellent accuracy by subjecting a smooth specimen to limits established by the Neuber equation. Data at 1,200 F were obtained with the same experimental techniques but only in the cyclically stable conditions. The Neuber prediction at this temperature gave relatively accurate results in terms of predicting stress and strain points.

Lucas, L. J.↗

Satellite elevation magnetic anomaly maps

The problem of inverting 2 deg average MAGSAT scalar anomalies for the region 80 W, 60 E longitude and 40 S, 70 N latitude was attempted on the LARS computer; however, the effort was aborted due to insufficient allocation of CPU-time. This problem is currently being resubmitted and should be implemented shortly for quantitative comparison with free-air gravity anomaly, geothermal, and tectonic data.

Braile, L. W.↗

Elevated temperature behavior of superplastically formed/weld-brazed titanium compression panels having advanced shaped stiffeners

The 316 C (600 F) buckling behavior of superplastically formed/weld-brazed titanium compression panels having advanced shaped stiffeners was investigated. Fabrication of the advanced shaped stiffeners was made possible by the increased formability afforded by the superplasticity characteristics of the titanium alloy Ti-6Al-4V. Stiffeners having the configurations of a conventional hat, a beaded web, a modified beaded web, a ribbed web, and a stepped web were investigated. The data from the panel tests include load-shortening curves, local buckling strengths, and failure loads. The superplastic formed/weld-brazed panels with the ribbed web and stepped web stiffeners developed 25 and 27 percent higher buckling strengths at 316 C (600 F) than panels with conventionally shaped stiffeners. The buckling load reductions for panels tested at 316 C (600 F), compared with panels tested at room temperature, were in agreement with predictions based on titanium material property data. The advantage that higher buckling loads can be readily achieved by superplastically forming of advanced stiffener shapes was demonstrated. Application of these advanced stiffener shapes offers the potential to achieve substantial weight savings in aerospace vehicles.

Royster, D. M.↗

Single cell performance studies on the Fe/Cr Redox Energy Storage System using mixed reactant solutions at elevated temperature

Experimental studies in a 14.5 sq cm single cell system using mixed reactant solutions at 65 C are described. Systems were tested under isothermal conditions i.e., reactants and the cell were at the same temperature. Charging and discharging performance were evaluted by measuring watt-hour and coulombic efficiencies, voltage-current relationships, hydrogen evolution and membrane resistivity. Watt-hour efficiencies ranged from 86% at 43 ma/sq cm to 75% at 129 ma/sq cm with corresponding coulombic efficiencies of 92% and 97%, respectively. Hydrogen evolution was less than 1% of the charge coulombic capacity during charge-discharge cycling. Bismuth and bismuth-lead catalyzed chromium electrodes maintained reversible performance and low hydrogen evolution under normal and adverse cycling conditions. Reblending of the anode and cathode solutions was successfully demonstrated to compensate for osmotic volume changes. Improved performance was obtained with mixed reactant systems in comparison to the unmixed reactant systems.

Gahn, R. F.↗

Tensile and Compressive Constitutive Response of 316 Stainless Steel at Elevated Temperatures

Creep rate in compression is lower by factors of 2 to 10 than in tension if the microstructure of the two specimens is the same and are tested at equal temperatures and equal but opposite stresses. Such behavior is characteristic for monotonic creep and conditions involving cyclic creep. In the latter case creep rate in both tension and compression progressively increases from cycle to cycle, rendering questionable the possibility of expressing a time stabilized constitutive relationship. The difference in creep rates in tension and compression is considerably reduced if the tension specimen is first subjected to cycles of tensile creep (reversed by compressive plasticity), while the compression specimen is first subjected to cycles of compressive creep (reversed by tensile plasticity). In both cases, the test temperature is the same and the stresses are equal and opposite. Such reduction is a reflection of differences in microstructure of the specimens resulting from different prior mechanical history.

Manson, S. S.↗

Evaluation of Three Constitutive Models for the Prediction of Hastelloy X Elevated Temperature Cyclic Response

The approach for the method development assumes that, for a thermally loaded structure, the overall strain history is defined by linear elastic analysis. The local stress history at a fatigue critical location is then determined from a one dimensional material behavior model and the local strain and temperature conditions. Three material models are currently being evaluated to assess their ability to predict relevant high temperature cyclic material response characteristics. They are: a time independent classical plasticity and creep representation, a time dependent viscoplastic model capable of predicting combined creep and plasticity effects, and an approximate elastic analysis approach that uses a series of stress-strain curves and a cyclic hardening model to determine reverse plasticity.

Moreno, V.↗