Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “droplets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Photoacoustic Extinctometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Photoacoustic Extinctiometer at 870 nm (Droplet Measurement Technology) Header: - AbsorptionNoise_870nm[1/Mm]: Noise level associated with the absorption measurement at 870 nm, expressed in inverse megameters (Mm⁻¹). - Absorption_870nm[1/Mm]: Absorption coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - Extinction_870nm[1/Mm]: Extinction coefficient of aerosols measured at 870 nm, expressing the sum of scattering and absorption by aerosols, in inverse megameters (Mm⁻¹). - Scattering_870nm[1/Mm]: Scattering coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - BackgroundAbsorption_870nm[1/Mm]: Background absorption measurement at 870 nm, used to correct the primary absorption data, expressed in inverse megameters (Mm⁻¹). - BackgroundScattering_870nm[1/Mm]: Background scattering measurement at 870 nm, used to correct the primary scattering data, expressed in inverse megameters (Mm⁻¹). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

CACTI: Fast Liquid Water Content

These data were collected during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI; https://www.arm.gov/research/campaigns/amf2018cacti ) field campaign in the Sierras de Córdoba mountain range of north-central Argentina as part of the ARM Aerial Facility (AAF) deployment. The ARM Aerial Facility Gulfstream-1 was operated from Las Higueras Airport (IATA: RCU, ICAO: SAOC), Río Cuarto, Córdoba, Argentina, for the Intensive Observation Period (IOP) from Nov. 1 through Dec. 15, 2018. The G-1 aircraft performed 22 research flights over the first ARM Mobile Facility (AMF1) location in the Sierras de Córdoba mountain range to measure atmospheric state and turbulence, cloud water content and droplet size distributions, aerosol precursor gases, and aerosol chemical composition and size distributions. The current data set presents re-processed Particle Volume Monitor PVM-100A (aka Gerber probe) data: Liquid Water Content (LWC), Particle Surface Area (PSA), and the effective droplet radius (re) averaged to 50Hz, 10Hz, and 1Hz.

54 ENVIRONMENTAL SCIENCES↗

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

Fundamental problems of injector design

The principal control of the combustion within a liquid-propellant rocket thrust chamber is provided by the injector. Only when precise control of the injection process is attained can optimum performance, dynamic stability, heat transfer compatibility and reproducibility be provided. Control must be designed into each step of the injection process with sufficient isolation provided to insure stability. In the design of the injector manifolding, the main desire is to provide mass and mixture ratio regulation across the injector face. The design of the injector orifices must be such that this mass and mixture ratio control is retained through the orifices and imparted to the droplet sprays that are produced. Furthermore, the orifice design must control the size and distribution of the droplets generated so that combustion will be completed within the chamber. Mechanical damping devices are often required to protect the early mixing zone from transverse velocities and associated displacement effects in the chamber. Only when each phase of the injection process is carefully controlled can the design aims be reached.

David T Harrje↗

Diffusive and radiative effects on vaporization times of drops in film boiling

Diffusive and radiative effects are incorporated into an analysis for the vaporization time of drops in film boiling. The momentum, energy, and continuity equations are solved with some appropriate simplifications so as to obtain a simple closed form solution for the overall film boiling heat transfer coefficient. Next, a theoretical expression for the droplet vaporization time is developed and compared to the measured vaporization times of water droplets vaporizing into air, argon, nitrogen, and helium. The agreement between experiment and theory is good. Under the helium blanket, the diffusive evaporative component is significant in comparison to the film boiling component.

Baumeister, K. J.↗

Frequency response of a vaporization process to distorted acoustic disturbances

The open-loop response properties expressed as the mass vaporized in phase and out of phase with the pressure oscillations were numerically evaluated for a vaporizing n-heptane droplet. The evaluation includes the frequency dependence introduced by periodic oscillation in droplet mass and temperature. A given response was achieved over a much broader range of frequency with harmonically distorted disturbances than with sinusoidal disturbances. The results infer that distortion increases the probability of incurring spontaneous and triggered instability in any rocket engine combustor by broadening the frequency range over which the vaporization process can support an instability.

Heidmann, M. F.↗

Project Fog Drops. Part 2: Laboratory investigations

Measurements of the total nucleus concentration and cloud condensation nuclei (CCN) were acquired for several conditions representing both high normal and severe pollution levels for the Los Angeles Basin as well as clean filtered air. The data show that in filtered air there is a large photochemically induced increase in the total particle content within a few minutes after starting the lamp. The concentration of CCN remains near zero, until sufficient coagulation and condensation occurs on the smaller Aitken particles. The addition of gaseous pollutants to filtered air results in large increases in the photochemical production of both the cloud and Aitken nucleus concentration. Fogs were also generated under controlled, reproducible conditions in the cloud chamber and seeded with aerosols of various compounds which form monomolecular surface films at air-water interfaces. Visibility characteristics and droplet data were obtained. The data suggest that droplet growth on treated nuclei can be retarded but fog formation was not significantly altered by the chemical seeding.

Kocmond, W. C.↗

Production of polydisperse sprays.

A device which produces a spray with a controllable drop size distribution is described. This system is especially well suited for generating nonsmooth (e.g., bimodal) distributions, although smooth distributions can also be produced. Droplets of uniform size result from the rapid growth of an oscillatory disturbance in a free liquid jet. Simultaneous generation of droplets of various diameters by this method produces the polydisperse spray. The range of drop diameters is approximately 300-3000 microns.

Pierce, T. H.↗

Some microphysical features of coastal and inland fogs.

Radiation fogs sampled at Los Angeles were found to possess low visibilities, high liquid water content (LWC), relatively small drops, narrow peaked drop-size distributions, and high concentrations of micron sized haze droplets. Typical characteristics of valley fogs observed at Elmira, N.Y., were low visibilities, moderately high LWC, low concentrations of haze droplets, and similar drop size distributions to those measured in Los Angeles. On the other hand, advection fogs observed in Vandenberg were characterized by less severe visibilities, low LWC, large drops in a broad drop-size distribution, and very low haze nucleus concentrations.

Mack, E. J.↗

Prediction of electron concentration reductions in re-entry flow fields due to electrophilic liquid and water injection.

Discussion of an analytical model which leads to predictions of reductions in electron concentrations in reentry flow fields due to the injection of electrophilic liquids and water. The processes incorporated into the model are: penetration and breakup of the liquid jet, droplet acceleration and vaporization, expansion of the liquid spray due to droplet vaporization, electrophilic vapor diffusion, heterogeneous and homogeneous charged species recombination kinetics and homogeneous electron attachment kinetics. Spray boundary calculations are shown to be in good agreement with photographic observations of water and Freon E-3 sprays in wind tunnel tests of a scale model RAM C-III flight vehicle. Fixed-bias electrostatic probe data taken during the RAM C-III flight are interpreted in terms of effective jet penetration distances - which are shown to be consistent with calculations using the present model.

Pergament, H. S.↗

Cloud microstructure studies

Over two thousand individual cloud droplet size distributions were measured with an optical cloud particle spectrometer flown on the NASA Convair 990 aircraft. Representative droplet spectra and liquid water content, L (gm/cu m) were obtained for oceanic stratiform and cumuliform clouds. For non-precipitating clouds, values of L range from 0.1 gm/cu m to 0.5 gm/cu m; with precipitation, L is often greater than 1 gm/cu m. Measurements were also made in a newly formed contrail and in cirrus clouds.

Blau, H. H., Jr.↗

Research of metal solidification in zero-g state

An experiment test apparatus that allows metal melting and resolidification in the three seconds available during free fall in a drop tower was built and tested in the tower. Droplets (approximately 0.05 cm) of pure nickel and 1090 steel were prepared in this fashion. The apparatus, including instrumentation, is described. As part of the instrumentation, a method for measuring temperature-time histories of the free floating metal droplets was developed. Finally, a metallurgical analysis of the specimens prepared in the apparatus is presented.

Aubin, W. M.↗

Study of the effects of condensation on the performance of Pioneer Venus probe windows

The transmission loss of Pioneer Venus Probe radiation windows if their exposed surfaces become contaminated with droplets of water, hydrochloric acid, sulfuric acid, and mercury which may be found in the Venusian atmosphere was investigated. Transmission loss was studied as a function of mass concentration of liquid droplets deposited on one surface of test window materials while the wavelength of the transmitting radiation is in the range of 0.3 to 30 microns. The parameters that affect the transmittance of radiation through a window are: (1) particle size, (2) surface concentration of particles, (3) wavelength of the radiation, (4) angle of acceptance of the radiation by the detector, and (5) the refractive index of the aerosol.

Testerman, M. K.↗

Cloud base levels for Jupiter and Venus and the heteromolecular nucleation theory

For purified binary gas mixtures like NH3-H2O or HCl-H2O, partial pressures appreciably greater than the two saturation partial pressures are needed to condense the gas mixture into small solution droplets (homogeneous heteromolecular nucleation). Thus without foreign nuclei, clouds are not as easily formed as in the theories of Lewis; the latter should be valid only if large condensation nuclei are available. We calculate here from classical homogeneous heteromolecular nucleation theory the threshold partial pressures necessary to achieve droplet nucleation for the gas mixtures NH3-H2O (Jupiter), HCl-H2O (Venus), H2SO4-H2O (Venus), and C2H5OH-H2O (laboratory).

Stauffer, D.↗

Structure and properties of a splat cooled 2024 aluminum alloy

In the investigation the alloy was melted, heated to 750 C, and atomized into fine droplets. The droplets were rapidly quenched against a heavy copper disk rotating at 1725 rpm. The resultant splat cooled flakes were screened. Three flake sizes were finally separated. Flakes of each size were separately processed. The characteristics of the splat cooling process and the properties of the obtained products are discussed. Splat cooling against a metallic substrate permits cooling rates up to about 1,000,000 deg C/sec. Increases in yield strength and tensile strength of 14 to 19% are observed for the splat products. Other improvements are connected with increases in fatigue life and stress rupture performance.

Lebo, M.↗

The time dependent growth of H2O-H2SO4 aerosols by heteromolecular condensation

A theory for the time-dependent growth of solution droplets by heteromolecular condensation is presented. The theory is applied to the growth of H2O-H2SO4 aerosols for relative humidities less than 100 per cent. Growth curves (droplet radius as a function of time) for different values of relative humidity are evaluated.

Hamill, P.↗