Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

X-ray Doppler Velocimetry for Diagnosis of Fluid Motion in ICF Implosions

Paper describes development of a novel diagnostic for measurement of bulk fluid motion in materials that is particularly applicable to very hot, x-ray emitting plasmas in the High Energy Density Physics (HEDP) regime. The X-ray Doppler Velocimetry technique relies on monochromatic imaging in multiple x-ray energy bands near the center of an x-ray emission line in a plasma, and utilizes bent imaging crystals. Higher energy bands are preferentially sensitive to plasma moving towards the viewer, while lower energy bands are preferentially sensitive to plasma moving away from the viewer. Combining multiple images in different energy bands allows for a reconstruction of the fluid velocity field integrated along the line of sight. This paper reviews the technique and discusses progress towards benchmarking the technique with proof-of-principle HEDP experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photo Doppler Velocimetry and Gamma/Neutron Yield Measurements of Godiva-IV Critical Assembly

The purpose of this experiment was to collect data for a dynamic benchmark of the Godiva-IV burst assembly. Data were taken using two different measurement systems. The gamma & neutron flux was measured using a calibrated, high-dynamic-range scintillator detector, the MHD-240. The measurement will be used to determine the total fission yield and alpha throughout the burst and shutdown sequence of Godiva-IV. The Photon Doppler Velocimetry (PDV) measurement detected the surface motion of the burst assembly as a function of time. The combined data will be used in a multi-physics simulation of the Godiva-IV burst assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

A NOVEL X-RAY IMAGING CRYSTAL SPECTROMETER FOR DOPPLER MEASUREMENTS OF ION TEMPERATURE AND PLASMA ROTATION VELOCITY PROFILES

A new type of X-ray imaging crystal spectrometer has been implemented on Alcator CMod for Doppler measurements of ion temperature and plasma rotation velocity profiles. The instrument consists of two spherically bent (102)-quartz crystals with radii of curvature of 1444 and 1385 mm and four 'PILATUS II' detector modules. It records spectra of He-like argon from the entire, 72 cm high, elongated plasma cross-section and spectra of H-like argon from a 20 cm high, central region of the plasma, with a spatial resolution of 1.3 cm and a time resolution of less than 20 ms. The new spectrometer concept is also of interest for the diagnosis of burning plasmas on future machines. This paper presents recent experimental results from Aclator C-Mod and discusses challenges in X-ray spectroscopy for the diagnosis of fusion plasmas on future machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detonation wave profiles measured in plastic bonded explosives using 1550 nm photon doppler velocimetry (PDV)

We present detonation wave profiles measured in two TATB based explosives and two HMX based explosives. Profiles were measured at the interface of the explosive and a Lithium-Fluoride (LiF) window using 1550 nm Photon Doppler Velocimetry (PDV). Planar detonations were produced by impacting the explosive with a projectile launched in a gas-gun. The impact state was varied to produce varied distance to detonation, and therefore varied support of the Taylor wave following the Chapman-Jouget (CJ) or sonic state. Profiles from experiments with different support should be the same between the Von-Neumann (VN) spike and CJ state and different thereafter. Comparison of profiles with differing support, therefore, allows us to estimate reaction zone lengths. For the TATB based explosive, a reaction zone length of {approx} 3.9 mm, 500 ns was measured in EDC-35, and a reaction zone length of {approx} 6.3 mm, 800 ns was measured in PBX 9502 pre-cooled to -55 C. The respective VN spike state was 2.25 {+-} 0.05 km/s in EDC-35 and 2.4 {+-} 0.1 km/s in the cooled PBX 9502. We do not believe we have resolved either the VN spike state (> 2.6 km/s) nor the reaction zone length (<< 50 ns) in the HMX based explosives.

36 MATERIALS SCIENCE↗

Acoustic Doppler Velocimeter (ADV) data from the University of New Hampshire Atlantic Marine Energy Center (UNH-AMEC ) Tidal Energy Test Site during a Perigean Spring Tide

The ADV measurements contained in this submission were taken on the floating turbine deployment platform (TDP) located at the Memorial Bridge in Portsmouth, NH. The measurements were conducted 11/4/2021-11/9/2021 with the fastest currents occurring on 11/7/2021. Along with the submission of ADV data, a .ppt and text document further explaining the ADV deployment location is included.

16 TIDAL AND WAVE POWER↗

Doppler Tracking Analysis

Explore the source record for details and available documents.

doppler doppler radar signal processing gravity gr↗

Development of the multi-purpose Cologne Compact Differential Plunger (CoCoDiff) for the measurement of nuclear level lifetimes with the Recoil Distance Doppler-shift method

Here, a new 3-foil plunger device, the Cologne Compact Differential (CoCoDiff) plunger has been built and commissioned. Due to its compact size, it can be used together with many different spectrometers and auxiliary detectors. As a commissioning experiment, level lifetimes of the $2^{+}_{1}$ and the $4^{+}_{1}$ excited states of 50 Cr have been measured, using the Differential Decay Curve method (DDCM). A derivation is given on how this method can be applied to a differential plunger measurement, in order to measure distances for lifetimes from two different regions of sensitivity at the same time. The commissioning experiment took place at the Cologne FN tandem accelerator, using the reaction 24 Mg( 32 S,4p2n) 50 Cr. Lifetimes, deduced from this measurement, agree well with literature values from earlier measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of sub-Doppler-width resonances in transmission and reflection spectra of micrometer-thick Cs vapor layers

We report experimental study of resonance sign reversal at the hyperfine F{sub g} = 4 → F{sub e} = 5 transition on D{sub 2} line of {sup 133}Cs. Alkali vapors are confined in an optical cell with micrometric thickness. For circular polarization of the irradiating light, transmission and reflection spectra, recorded at different laser intensities and different temperature of alkali vapor, are studied and compared. At low laser intensity, in the transmission spectra we observe a narrow resonance of increased absorption (bright resonance) at the F{sub g} = 4 → F{sub e} = 5 transition, however in reflection spectra, recorded at the same experimental conditions, this bright resonance transforms into a dark resonance of reduced absorption. A simple explanation is proposed in order to explain the observed difference between the transmission and reflection spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of Doppler coherence imaging for 2D ion velocity measurements on DIII-D

Coherence Imaging Spectroscopy (CIS) has emerged as a powerful tool for investigating complex ion phenomena in the boundary of magnetically confined plasma devices. The combination of Fourier-transform interferometry and high-resolution fast-framing cameras has made it possible to make sensitive velocity measurements that are also spatially resolved. However, this sensitivity makes the diagnostic vulnerable to environmental effects including thermal drifts, vibration, and magnetic fields that can influence the velocity measurement. Additionally, the ability to provide an absolute calibration for these geometries can be impacted by differences in the light-collection geometry between the plasma and reference light source, spectral impurities, and the presence of thin-films on in-vessel optics. This work discusses the mitigation of these effects and demonstration that environmental effects result in less than 0.5 km/s error on the DIII-D CIS systems. A diagnostic comparison is used to demonstrate agreement between CIS and traditional spectroscopy once tomographic artifacts are accounted for.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DOPPLER SHIFTS IN ACTIVE REGION MOSS USING SOHO/SUMER

The velocity of the plasma at the footpoint of hot loops in active region cores can be used to discriminate between different heating frequencies. Velocities on the order of a few kilometers per second would indicate low-frequency heating on sub-resolution strands, while velocities close to zero would indicate high-frequency (steady) heating. To discriminate between these two values requires accurate velocity measurements; previous velocity measurements suffer from large uncertainties, mainly due to the lack of an absolute wavelength reference scale. In this paper, we determine the velocity in the loop footpoints using observations from Solar Ultraviolet Measurements of Emitted Radiation (SUMER) on Solar and Heliospheric Observatory. We use neutral spectral lines to determine the wavelength scale of the observations with an uncertainty in the absolute velocity of <3.5 km s{sup -1} and co-aligned Transition Region and Coronal Explorer (TRACE) images to identify footpoint regions. We studied three different active regions and found average redshifts in the Ne VIII 770 A emission line (formed at 6 Multiplication-Sign 10{sup 5} K) of 5.17 {+-} 5.37 km s{sup -1} and average redshifts in the C IV 1548 and 1550 A emission lines (formed at 1 Multiplication-Sign 10{sup 5} K) of 13.94 {+-} 4.93 km s{sup -1} and 14.91 {+-} 6.09 km s{sup -1}, respectively. We find no correlation between the brightness in the spectral line and the measured velocity, nor do we find correlation between the Ne VIII and C IV velocities measured co-spatially and co-temporally. SUMER scanned two of the active regions twice; in those active regions we find positive correlation between the co-spatial velocities measured during the first and second scans. These results provide definitive and quantitative measurements for comparisons with simulations of different coronal heating mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Subluminal and superluminal parametric doppler effects in the case of light reflection from a moving smooth medium inhomogeneity

The reflection of test radiation from a smooth inhomogeneity of medium characteristics propagating with a subluminal or superluminal velocity is analyzed. The equations describing the propagation of the forward- and counter-propagating waves in such an inhomogeneous medium are derived. Quasi-phase conjugation is demonstrated in the case of superluminal inhomogeneities. The Bragg resonance conditions are formulated and the conditions for increasing the reflection coefficient of radiation from an inhomogeneity are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full report of laser doppler velocimetry (Het-V) data, results , and analysis for pRad shot 0632

This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shot also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗