Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Frequency response in short thermocouple wires

Theoretical expressions are derived for the steady state frequency response of a thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for a nonuniform wire with unequal material properties and wire diameters across the junction. The amplitude ratio at low frequency omega approaches 0 agrees with the results of Scadron and Warshawsky (1952) for a steady state temperature distribution. Moreover, the frequency response for a nonuniform wire in the limit of infinite length l approaches infinity is shown to reduce to a simple expression that is analogous to the classic first order solution for a thermocouple wire with uniform properties. Theoretical expressions are also derived for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire and a two material wire with unequal material properties across the junction. For the case of a one material supported wire, an exact solution is derived which compares favorably with an approximate expression that only matches temperatures at the support junction. Moreover, for the case of a two material supported wire, an analytical expression is derived that closely correlates numerical results. Experimental measurements are made for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 pct. with the theoretical predictions of Forney and Fralick (1991). This is accomplished by choosing a natural frequency omega sub n for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decrease the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

Application of the Analogy Between Water Flow with a Free Surface and Two-dimensional Compressible Gas Flow

The theory of hydraulic analogy, that is, the analogy between water flow with a free surface and two-dimensional compressible gas flow and the limitations and conditions of the analogy are discussed. A test run was made using the hydraulic analogy as applied to the flow about circular cylinders at various diameters at subsonic velocities extending to the super critical range. The apparatus and techniques used in this application are described and criticized. Reasonably satisfactory agreement of pressure distributions and flow fields existed between water and airflow about corresponding bodies. This agreement indicated the possibility of extending experimental compressibility research by new methods.

Orlin, W James↗

Velocity Distribution in the Boundary Layer of a Submerged Plate

This report deals with the measurement of the velocity distribution of the air in the velocity of a plate placed parallel to the air flow. The measurements took place in a small wind tunnel where the diameter of the entrance cone is 30 cm and the length of the free jet between the entrance and exit cones is about 2.5 m. The measurements were made in the free jet where the static pressure was constant, which was essential for the method of measurement used.

Hansen, M↗

16-foot transonic tunnel test section flowfield survey

A flow survey has been made of the test section of the NASA Langley Research Center 16-Foot Transonic Tunnel at subsonic and supersonic speeds. The survey was performed using five five-hole pyramid-head probes mounted at 14 inch intervals on a survey rake. Probes were calibrated at freestream Mach numbers from 0.50 to 0.95 and from 1.18 to 1.23. Flowfield surveys were made at Mach numbers from 0.50 to 0.90 and at Mach 1.20. The surveys were made at tunnel stations 130.6, 133.6, and 136.0. By rotating the survey rake through 180 degrees, a cylindrical volume of the test section 4.7 feet in diameter and 5.4 feet long centered about the tunnel centerline was surveyed. Survey results showing the measured test section upflow and sideflow characteristics and local Mach number distributions are presented. The report documents the survey probe calibration techniques used, summarizes the procedural problems encountered during testing, and identifies the data discrepancies observed during the post-test data analysis.

Yetter, J. A.↗

In-situ measurements of changes in stratospheric aerosol and the N2O-aerosol relationship inside and outside of the polar vortex

Two optical particle counters on the ER-2, together covering a particle size diameter range from 0.1 microns to 23 microns, were used to measure the aerosol bulk quantities integral number, aerosol surface and volume, as well as detailed size distributions inside and outside of the polar vortex in the lower stratosphere. While AAES I (Arctic Airborne Stratospheric Expedition, (Dec. 88 - Feb. 89) was conducted in a period of relative volcanic quiescence, enhancements in aerosol number, surface and volume of factors around 10, 25 and 100 were observed during AASE 2 (Aug. 91 - Mar. 92) due to the eruption of Mt. Pinatubo. The changes in these bulk quantities as well as in the size distributions measured both outside and inside the polar vortex are presented and compared with those obtained in polar stratospheric cloud events (AASE I). Except for a shift towards larger aerosol mixing ratios the general shape of correlograms between the measured N2O and particle mixing ratios remain similar before and after the eruption. Similar correlograms are used to interpret data from vertical profiles inside and outside of the polar vortex.

Borrmann, S.↗

In-Situ Measurements of Changes in Stratospheric Aerosol and the N2O - Aerosol Relationship inside and outside of the Polar Vortex

Two optical particle counters on the ER-2, together covering a particle size diameter range from 0.1 micrometers to 23 micrometers, were used to measure the aerosol bulk quantities integral number, aerosol surface and volume, as well as detailed size distributions inside and outside of the polar vortex in the lower stratosphere. While AASE I (Arctic Airborne Stratospheric Expedition, (Dec. 1988 - Feb. 1989) was conducted in a period of relative volcanic quiescence, enhancements in aerosol number, surface and volume of factors around 10, 25 and 100 were observed during AASE II (Aug. 1991 - Mar. 1992) due to the eruption of Mt. Pinatubo. The changes in these bulk quantities as well as in the size distributions measured both outside and inside the the polar vortex are presented and compared with those obtained in polar stratospheric cloud events (AASE I). Except for a shift towards larger aerosol mixing ratios the general shape of correlograms between the measured N2O and particle mixing ratios remain similar before and after the eruption. Similar correlograms are used to interpret data from vertical profiles inside and outside of the polar vortex.

Borrmann, S.↗

Synthetic Jets in Cross-flow: Jets From Orifices of Different Geometry - Part 2

The flow fields of synthetic jets in a cross-flow from orifices of different geometry are investigated. The geometries include a straight, a tapered, a pitched and a cluster of nine orifices, all having the same cross-sectional area through which the perturbation is discharged into the cross-flow. The strength of the jet from the tapered orifice in comparison to that from the straight one is found to be only slightly enhanced. The flow field from the cluster of orifices, when viewed a few equivalent diameters downstream, is similar to that from the single orifice. However, the penetration is somewhat lower in the former case due to the increased mixing of the distributed jets with the cross-flow. The penetration for the pitched configuration is the lowest, as expected. The jet trajectories for the straight and pitched orifices are well represented by correlation equations available for steady jets-in-cross-flow. Distributions of streamwise velocity, vorticity as well as turbulence intensity are documented for various cases. In addition, distributions of phase-averaged velocity and vorticity for the cylindrical and the clustered orifices are presented providing an insight into the flow dynamics.

Milanovic, Ivana M.↗

Comet 81p/Wild 2: The Updated Stardust Coma Dust Fluence Measurement for Smaller (Sub 10-Micrometre) Particles

Micrometre and smaller scale dust within cometary comae can be observed by telescopic remote sensing spectroscopy [1] and the particle size and abundance can be measured by in situ spacecraft impact detectors [2]. Initial interpretation of the samples returned from comet 81P/Wild 2 by the Stardust spacecraft [3] appears to show that very fine dust contributes not only a small fraction of the solid mass, but is also relatively sparse [4], with a low negative power function describing grain size distribution, contrasting with an apparent abundance indicated by the on-board Dust Flux Monitor Instrument (DFMI) [5] operational during the encounter. For particles above 10 m diameter there is good correspondence between results from the DFMI and the particle size inferred from experimental calibration [6] of measured aerogel track and aluminium foil crater dimensions (as seen in Figure 4 of [4]). However, divergence between data-sets becomes apparent at smaller sizes, especially submicrometre, where the returned sample data are based upon location and measurement of tiny craters found by electron microscopy of Al foils. Here effects of detection efficiency tail-off at each search magnification can be seen in the down-scale flattening of each scale component, but are reliably compensated by sensible extrapolation between segments. There is also no evidence of malfunction in the operation of DFMI during passage through the coma (S. Green, personal comm.), so can the two data sets be reconciled?

Price, M. C.↗

Characterization of the Nucleus, Morphology, and Activity of Interstellar Comet 2I/Borisov by Optical and Near-infrared GROWTH, Apache Point, IRTF, ZTF, and Keck Observations

We present visible and near-infrared (NIR) photometric and spectroscopic observations of interstellar object (ISO) 2I/Borisov taken from 2019 September 10 to 2019 December 20 using the GROWTH, the Apache Point Observatory Astrophysical Research Consortium 3.5 m, and the NASA Infrared Telescope Facility 3.0 m combined with pre- and postdiscovery observations of 2I obtained by the Zwicky Transient Facility from 2019 March 17 to 2019 May 5. Comparison with imaging of distant solar system comets shows an object very similar to mildly active solar system comets with an outgassing rate of ∼1027 mol s−1. The photometry, taken in filters spanning the visible and NIR range, shows a gradual brightening trend of ∼0.03 mag day−1 since 2019 September 10 UTC for a reddish object becoming neutral in the NIR. The light curve from recent and prediscovery data reveals a brightness trend suggesting the recent onset of significant H2O sublimation with the comet being active with super volatiles such as CO at heliocentric distances >6 au consistent with its extended morphology. Using the advanced capability to significantly reduce the scattered light from the coma enabled by high-resolution NIR images from Keck adaptive optics taken on 2019 October 4, we estimate a diameter for 2I’s nucleus of <~1.4 km. We use the size estimates of 1I/’Oumuamua and 2I/Borisov to roughly estimate the slope of the ISO size distribution, resulting in a slope of ∼3.4 ± 1.2, similar to solar system comets and bodies produced from collisional equilibrium.

Bryce T Bolin↗

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

H S Alpert↗

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

LOFTID↗

Examination of New Theory for Neutron Multiplicity Counting of Non-Point-Like Sources of Special Nuclear Material

The purpose of a nondestructive assay is to accurately verify the declared mass of special nuclear material (SNM) samples in a limited amount of time. One measurement modality is neutron multiplicity counting (NMC), which relates time-correlated neutron detection rates to the mass of SNM present. Traditional theory assumes point-like sources, which can be ill-posed for kilogram-quantity, bulk samples. Recent theory was developed to improve NMC accuracy for non-point-like samples. This work preliminarily examines the theory with measured data. The OSCAR prototype (a 3-by-4 array of 5.08-cm-thick, 5.08-cm-diameter trans-stilbene organic scintillators) measures configurations of 29.41-49.00 kg of highly enriched uranium (93wt% 235 U). Adjusted factorial moments for the emitted neutron multiplicity distributions are used to account for the shape and type of SNM being measured.

252Cf↗

Functional soft materials and methods of making and using thereof

Disclosed are functional materials for use in additive manufacturing (AM). The functional material can comprise an elastomeric composition (e.g., a silicone composite) for use in, for example, direct ink writing. The elastomeric composition can include and elastomeric resin, and a magnetic nanorod filler dispersed within the elastomeric resin. Nanorod characteristics (e.g., length, diameter, aspect ratio) can be selected to create 3D-printed constructs with desired mechanical properties along different axes. Furthermore, since nickel nanorods are ferromagnetic, the spatial distribution and orientation of nanorods within the continuous phase can be controlled with an external magnetic field. This level of control over the nanostructure of the material system offers another degree of freedom in the design of functional parts and components with anisotropic properties. Magnetic fields can be used to remotely sense compression of the constructs, or alternatively, control the stiffness of these materials.

Berkland, Cory↗

Functional soft materials and methods of making and using thereof

Disclosed are functional materials for use in additive manufacturing (AM). The functional material can comprise an elastomeric composition (e.g., a silicone composite) for use in, for example, direct ink writing. The elastomeric composition can include an elastomeric resin, and a magnetic nanorod filler dispersed within the elastomeric resin. Nanorod characteristics (e.g., length, diameter, aspect ratio) can be selected to create 3D-printed constructs with desired mechanical properties along different axes. Furthermore, since nickel nanorods are ferromagnetic, the spatial distribution and orientation of nanorods within the continuous phase can be controlled with an external magnetic field. This level of control over the nanostructure of the material system offers another degree of freedom in the design of functional parts and components with anisotropic properties. Magnetic fields can be used to remotely sense compression of the constructs, or alternatively, control the stiffness of these materials.

Berkland, Cory↗

AC Loss Analysis on the Superconducting Coupling Magnet in MICE

A pair of coupling solenoids is used in MICE experiment to generate magnetic field which keeps the muons within the iris of thin RF cavity windows. The coupling solenoids have a 1.5-meter inner diameter and will produce 7.4 T peak magnetic field. Three types of AC losses in coupling solenoid are discussed. The affect of AC losses on the temperature distribution within the cold mass during charging and rapid discharging process is analyzed also. The analysis result will be further confirmed by the experiment of the prototype solenoid for coupling solenoid, which will be designed, fabricated and tested at ICST.

42 ENGINEERING↗

SU-C-BRE-02: BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning

Purpose: SBRT with hypofractionated dose schemata has emerged a compelling treatment modality for medically inoperable early stage lung cancer patients. It requires more accurate dose calculation and treatment delivery technique. This report presents the relationship between tumor control probability(TCP) and size-adjusted biological effective dose(sBED) of tumor volume for MC lung SBRT patients. Methods: Fifteen patients who were treated with MC-based lung SBRT to 50Gy in 5 fractions to PTVV100%=95% were studied. ITVs were delineated on MIP images of 4DCT-scans. PTVs diameter(ITV+5mm margins) ranged from 2.7–4.9cm (mean 3.7cm). Plans were generated using non-coplanar conformal arcs/beams using iPlan XVMC algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX with HD-MLCs and 6MVSRS(1000MU/min) mode, following RTOG-0813 dosimetric guidelines. To understand the known uncertainties of conventional heterogeneities-corrected/uncorrected pencil beam (PBhete/ PB-homo) algorithms, dose distributions were re-calculated with PBhete/ PB-homo using same beam configurations, MLCs and monitor units. Biologically effective dose(BED10) was computed using LQ-model with α/β=10Gy for meanPTV and meanITV. BED10-c*L, gave size-adjusted BED(sBED), where c=10Gy/cm and L=PTV diameter in centimeter. The TCP model was adopted from Ohri et al.(IJROBP, 2012): TCP = exp[sBEDTCD50]/ k /(1.0 + exp[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy; and more realistic MC-based TCP was computed for PTV(V99%). Results: Mean PTV PB-hete TCP value was 6% higher, but, mean PTV PB-homo TCP value was 4% lower compared to mean PTV MC TCP. Mean ITV PB-hete/PB-homo TCP values were comparable (within ±3.0%) to mean ITV MC TCP. The mean PTV(V99%)had BED10=90.9±3.7%(median=92.2%),sBED=54.1±8.2%(median=53.5%) corresponding to mean MC TCP value of 84.8±3.3%(median=84.9%) at 2- year local control. Conclusion: The TCP model which incorporates BED10 and tumor diameter indicates that radiobiological effect of target volume and dose calculation algorithm significantly affects TCP for lung SBRT patients. Dose calculation using MC-based algorithm is more realistic with tissue heterogeneities and is routinely performed in our clinic. Patients will be followed up to determine whether TCP prediction correlate clinical outcomes.

60 APPLIED LIFE SCIENCES↗

Dose Distribution Analysis in Stereotactic Body Radiotherapy Using Dynamic Conformal Multiple Arc Therapy

Purpose: We have used dynamic conformal multiple arc therapy (DCMAT) for stereotactic body radiotherapy (SBRT) since 2001. We investigated the consistency of DCMAT for SBRT using dose-volume histogram analysis. Methods and Materials: A total of 50 patients with peripheral lung tumors underwent SBRT. The median tumor diameter was 2.4 cm (range, 0.9-5.9). Treatment planning was performed using a superposition algorithm. The prescribed 50 Gy dose was divided into five fractions. The prescribed dose was defined as 80% of the maximal dose in the planning target volume (PTV), and the leaf margins were modified to ensure the PTV was included in the 80% isodose surface. The dose-volume histogram analysis was used to assess the PTV and normal lung volume. Results: The median dose covering 95% of the PTV was 50.27 Gy (range, 46.14-52.67), essentially consistent with the prescribed dose. The median homogeneity and conformity index was 1.41 (range, 1.31-1.53) and 1.73 (range, 1.41-2.21), respectively. The median volume of lung receiving {>=}20 Gy (V{sub 20}) was 4.2% (range, 1.4-10.2%). A linear correlation was found between the tumor diameter and V{sub 20}, and an even stronger correlation was found between the PTV/(normal lung volume) and V{sub 20}. The estimated V{sub 20} was 7.1% (range, 3.9-10.4%) for a 5-cm-diameter tumor, assumed to be the maximal size limitation for SBRT. Conclusion: SBRT with DCMAT achieved high conformity and delivered adequate doses within the PTV. The median dose covering 95% of the PTV was consistent with the prescribed dose. V{sub 20} can be estimated using the tumor diameter and normal lung volume. DCMAT was thus both a feasible and a reproducible method of SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗