Proving the Business Case for Building Analytics

As building monitoring becomes more common, facilities teams are faced with an overwhelming amount of data. These data do not typically lead to insights or corrective actions unless they are stored, organized, analyzed, and prioritized in automated ways. Buildings are full of energy savings potential that can be uncovered with the right analysis. With analytic software applied to everyday building operations, owners are using data to their advantage and realizing cost savings through improved energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First JAM results on the determination of polarized parton distributions

The Jefferson Lab Angular Momentum (JAM) collaboration is a new initiative aimed to the study of the angular-momentum-dependent structure of the nucleon. First results on the determination of spin-dependent parton distribution functions from world data on polarized deep-inelastic scattering will be presented and compared with previous determinations from other groups. Different aspects of global QCD analysis will be discussed, including effects due to nuclear structure, higher twist, and target-mass corrections, as well as the impact of different data selections.

Jimenez-Delgado, Pedro↗

First JAM results on the determination of polarized parton distributions

The Jefferson Lab Angular Momentum (JAM) collaboration is a new initiative aimed to the study of the angular-momentum-dependent structure of the nucleon. First results on the determination of spin-dependent parton distribution functions from world data on polarized deep-inelastic scattering will be presented and compared with previous determinations from other groups. Different aspects of global QCD analysis will be discussed, including effects due to nuclear structure, higher twist, and target-mass corrections, as well as the impact of different data selections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strangeness Contributions to the Static Properties of the Proton

Precision measurements of parity violation in electron-nucleus elastic scattering at low Q2 are sensitive to the strange quark magnetic moment and the strange-charge radius of the proton, and thus provide a unique opportunity to cleanly isolate the role of the quark- antiquark sea in low-energy Quantum Chromodynamics. While recent results have placed a tight upper-bound on strange quark contributions to the electric form-factor at low Q2, significant (~10%) contributions to the proton magnetic moment are still allowed by the existing data. Results from recently completed measurements of backward-angle scattering, by the G0 and A4 collaborations, will provide an improved sensitivity to the strange magnetic form-factor GsM of the proton as well as to axial radiative corrections which are otherwise poorly constrained by existing data. An important complement to those measurements is the HAPPEX-III experiment, which will measure forward-angle scattering at Q2 ~ 0.62 GeV2 with a much greater precision than has previously been achieved in that kinematic range, with a sensitivity to the linear combination of strange-quark vector form- factors GsE + 0.48GsM. In combination with the published results from low Q2, this measurement will play a crucial role in determining the possible strange quark contribution to the magnetic moment of the proton.

Paschke, Kent↗

Physical results from 2+1 flavor domain wall QCD and SU(2) chiral perturbation theory

We have simulated QCD using 2+1 flavors of domain wall quarks and the Iwasaki gauge action on a (2.74 fm){sup 3} volume with an inverse lattice scale of a{sup -1}=1.729(28) GeV. The up and down (light) quarks are degenerate in our calculations and we have used four values for the ratio of light quark masses to the strange (heavy) quark mass in our simulations: 0.217, 0.350, 0.617, and 0.884. We have measured pseudoscalar meson masses and decay constants, the kaon bag parameter B{sub K}, and vector meson couplings. We have used SU(2) chiral perturbation theory, which assumes only the up and down quark masses are small, and SU(3) chiral perturbation theory to extrapolate to the physical values for the light quark masses. While next-to-leading order formulas from both approaches fit our data for light quarks, we find the higher-order corrections for SU(3) very large, making such fits unreliable. We also find that SU(3) does not fit our data when the quark masses are near the physical strange quark mass. Thus, we rely on SU(2) chiral perturbation theory for accurate results. We use the masses of the {omega} baryon, and the {pi} and K mesons to set the lattice scale and determine the quark masses. We then find f{sub {pi}}=124.1(3.6){sub stat}(6.9){sub syst} MeV, f{sub K}=149.6(3.6){sub stat}(6.3){sub syst} MeV, and f{sub K}/f{sub {pi}}=1.205(0.018){sub stat}(0.062){sub syst}. Using nonperturbative renormalization to relate lattice regularized quark masses to regularization independent momentum scheme masses, and perturbation theory to relate these to MS, we find m{sub ud}{sup MS}(2 GeV)=3.72(0.16){sub stat}(0.33){sub ren}(0.18){sub syst} MeV, m{sub s}{sup MS}(2 GeV)=107.3(4.4){sub stat}(9.7){sub ren}(4.9){sub syst} MeV, and m-tilde{sub ud} ratio m-tilde{sub s}=1 ratio 28.8(0.4){sub stat}(1.6){sub syst}. For the kaon bag parameter, we find B{sub K}{sup MS}(2 GeV)=0.524(0.010){sub stat}(0.013){sub ren}(0.025){sub syst}. Finally, for the ratios of the couplings of the vector mesons to the vector and tensor currents (f{sub V} and f{sub V}{sup T}, respectively) in the MS scheme at 2 GeV we obtain f{sub {rho}}{sup T}/f{sub {rho}}=0.687(27); f{sub K*}{sup T}/f{sub K*}=0.712(12), and f{sub {phi}}{sup T}/f{sub {phi}}=0.750(8)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MULTI-KEV X-RAY YIELDS FROM HIGH-Z GAS TARGETS FIELDED AT OMEGA

The authors report on modeling of x-ray yield from gas-filled targets shot at the OMEGA laser facility. The OMEGA targets were 1.8 mm long, 1.95 mm in diameter Be cans filled with either a 50:50 Ar:Xe mixture, pure Ar, pure Kr or pure Xe at {approx} 1 atm. The OMEGA experiments heated the gas with 20 kJ of 3{omega} ({approx} 350 nm) laser energy delivered in a 1 ns square pulse. the emitted x-ray flux was monitored with the x-ray diode based DANTE instruments in the sub-keV range. Two-dimensional x-ray images (for energies 3-5 keV) of the targets were recorded with gated x-ray detectors. The x-ray spectra were recorded with the HENWAY crystal spectrometer at OMEGA. Predictions are 2D r-z cylindrical with DCA NLTE atomic physics. Models generally: (1) underpredict the Xe L-shell yields; (2) overpredict the Ar K-shell yields; (3) correctly predict the Xe thermal yields; and (4) greatly underpredict the Ar thermal yields. However, there are spreads within the data, e.g. the DMX Ar K-shell yields are correctly predicted. The predicted thermal yields show strong angular dependence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid inflation revisited in light of WMAP5 data

We study the effects of including one-loop radiative corrections in a nonsupersymmetric hybrid inflationary model. These corrections can arise from Yukawa couplings between the inflaton and right-handed neutrinos, and induce a maximum in the potential which admits hilltop-type solutions in addition to the standard hybrid solutions. We obtain a red-tilted spectral index n{sub s}, consistent with Wilkinson Microwave Anisotropy Probe 5 yr analysis data, for sub-Planckian values of the field. This is in contrast to the tree level hybrid analysis, in which a red-tilted spectrum is achieved only for trans-Planckian values of the field. Successful reheating is obtained at the end of the inflationary phase via a conversion of the inflaton and waterfall fields into right-handed neutrinos, whose subsequent decay can explain the observed baryon asymmetry via leptogenesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of Polarized PDFs and Higher Twist after the CLAS and COMPASS Data

The impact of the recent very precise CLAS and COMPASS g{sub 1}/F{sub 1} data on polarized parton densities and higher twist effects is discussed. It is demonstrated that the low Q{sup 2} CLAS data improve essentially our knowledge of higher twist corrections to the spin structure function g{sub 1}, while the large Q{sup 2} COMPASS dala influence mainly the strange quark and gluon polarizations which slightly decrease. It is shown that the uncertainties in the determination of the polarized parlon densities are significantly reduced. We find also that the present inclusive DIS data cannot rule out a negative polarized and changing in sign gluon densities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduced partition function ratios of iron and oxygen in goethite

First-principles calculations based on the density functional theory (DFT) with or without the addition of a Hubbard U correction, are performed on goethite in order to determine the iron and oxygen reduced partition function ratios (beta-factors). The calculated iron phonon density of states (pDOS), force constant and beta-factor are compared with reevaluated experimental beta-factors obtained from Nuclear Resonant Inelastic X-ray Scattering (NRIXS) measurements. The reappraisal of old experimental data is motivated by the erroneous previous interpretation of the low- and high-energy ends of the NRIXS spectrum of goethite and jarosite samples (Dauphas et al., 2012). Here the NRIXS data are analyzed using the SciPhon software that corrects for non-constant baseline. New NRIXS measurements also demonstrate the reproducibility of the results. Unlike for hematite and pyrite, a significant discrepancy remains between DFT, NRIXS and the existing Mossbauer-derived data. Calculations suggest a slight overestimation of the NRIXS signal possibly related to the baseline definition. The intrinsic features of the samples studied by NRIXS and Mossbauer spectroscopy may also contribute to the discrepancy (e. g., internal structural and/or chemical defects, microstructure, surface contribution). As for oxygen, DFT results indicate that goethite and hematite have similar beta-factors, which suggests almost no fractionation between the two minerals at equilibrium.

58 GEOSCIENCES↗

Global QCD analysis of spin PDFs in the proton with high-𝑥 and lattice constraints

We perform a comprehensive global QCD analysis of spin-dependent parton distribution functions (PDFs), combining all available data on inclusive and semi-inclusive deep-inelastic scattering (DIS), as well as inclusive weak boson and jet production in polarized 𝑝⁢𝑝 collisions, simultaneously extracting spin-averaged PDFs and fragmentation functions. Including recent Jefferson Lab DIS data at high 𝑥, together with subleading power corrections to the leading-twist framework, allows us to verify the stability of the PDFs for 𝑊 2 ≥ 4 GeV 2 and quantify the uncertainties on the spin structure functions more reliably. We explore the use of new lattice QCD data on gluonic pseudo-Ioffe time distributions, which, together with jet production and high-𝑥 DIS data, improve the constraints on the polarized gluon PDF. The expanded kinematic reach afforded by the data into the high-𝑥 region allows us to refine the bounds on higher-twist contributions to the spin structure functions, and test the validity of the Bjorken sum rule.

Perturbative QCD↗

Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

Purpose: To determine detector-specific output correction factors,k{sub Q} {sub c{sub l{sub i{sub n}}}} {sub ,Q} {sub m{sub s{sub r}}} {sup f{sub {sup {sub c}{sub l}{sub i}{sub n}{sub {sup ,f{sub {sup {sub m}{sub s}{sub r}{sub ,}}}}}}}} in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers. Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179–5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm{sup 2} and 10 × 10 cm{sup 2} from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm{sup 2}. Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ±1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates. Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bahamas: new analysis of type ia supernovae reveals inconsistencies with standard cosmology

We present results obtained by applying our BAyesian HierArchical Modeling for the Analysis of Supernova cosmology (BAHAMAS) software package to the 740 spectroscopically confirmed supernovae of type Ia (SNe Ia) from the “Joint Light-curve Analysis” (JLA) data set. We simultaneously determine cosmological parameters and standardization parameters, including corrections for host galaxy mass, residual scatter, and object-by-object intrinsic magnitudes. Combining JLA and Planck data on the cosmic microwave background, we find significant discrepancies in cosmological parameter constraints with respect to the standard analysis: we find Ω{sub m}=0.399±0.027, 2.8σ higher than previously reported, and w=−0.910±0.045, 1.6σ higher than the standard analysis. We determine the residual scatter to be σ{sub res}=0.104±0.005. We confirm (at the 95% probability level) the existence of two subpopulations segregated by host galaxy mass, separated at log{sub 10}(M/M{sub ⊙})=10, differing in mean intrinsic magnitude by 0.055 ± 0.022 mag, lower than previously reported. Cosmological parameter constraints, however, are unaffected by the inclusion of corrections for host galaxy mass. We find ∼4σ evidence for a sharp drop in the value of the color correction parameter, β(z), at a redshift z{sub t}=0.662±0.055. We rule out some possible explanations for this behavior, which remains unexplained.

79 ASTRONOMY AND ASTROPHYSICS↗

EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities

Purpose: One of the fundamental parameters used for dose calculation is percentage depth-dose, generally measured employing ionization chambers. There are situations where use of ion chambers for measuring depth-doses is difficult or problematic. In such cases, radiochromic film might be an alternative. The EBT-2 model GAFCHROMIC film was investigated as a potential tool for depth-dose measurement in radiotherapy beams over a broad range of energies and modalities. Methods: Pieces of the EBT-2 model GAFCHROMIC EBT2 film were exposed to x-ray, electron, and proton beams used in radiotherapy. The beams employed for this study included kilovoltage x-rays (75 kVp), {sup 60}Co gamma-rays, megavoltage x-rays (18 MV), electrons (7 and 20 MeV), and pristine Bragg-peak proton beams (126 and 152 MeV). At each beam quality, film response was measured over the dose range of 0.4-8.0 Gy, which corresponds to optical densities ranging from 0.05 to 0.4 measured with a flat-bed document scanner. To assess precision in depth-dose measurements with the EBT-2 model GAFCHROMIC film, uncertainty in measured optical density was investigated with respect to variation in film-to-film and scanner-bed uniformity. Results: For most beams, percentage depth-doses measured with the EBT-2 model GAFCHROMIC film show an excellent agreement with those measured with ion chambers. Some discrepancies are observed in case of (i) kilovoltage x-rays at larger depths due to beam-hardening, and (ii) proton beams around Bragg-peak due to quenching effects. For these beams, an empirical polynomial correction produces better agreement with ion-chamber data. Conclusions: The EBT-2 model GAFCHROMIC film is an excellent secondary dosimeter for measurement of percentage depth-doses for a broad range of beam qualities and modalities used in radiotherapy. It offers an easy and efficient way to measure beam depth-dose data with a high spatial resolution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase I Contaminant Transport Parameters for the Groundwater Flow and Contaminant Transport Model of Corrective Action Unit 99: Rainier Mesa/Shoshone Mountain, Nevada Test Site, Nye County, Nevada, Revision 1

This document presents a summary and framework of available transport data and other information directly relevant to the development of the Rainier Mesa/Shoshone Mountain (RMSM) Corrective Action Unit (CAU) 99 groundwater transport model. Where appropriate, data and information documented elsewhere are briefly summarized with reference to the complete documentation.

54 ENVIRONMENTAL SCIENCES↗

SNIa Cosmology Analysis Results from Simulated LSST Images: From Difference Imaging to Constraints on Dark Energy

Abstract The Vera Rubin Observatory Legacy Survey of Space and Time (LSST) is expected to process ∼10 6 transient detections per night. For precision measurements of cosmological parameters and rates, it is critical to understand the detection efficiency, magnitude limits, artifact contamination levels, and biases in the selection and photometry. Here we rigorously test the LSST Difference Image Analysis (DIA) pipeline using simulated images from the Rubin Observatory LSST Dark Energy Science Collaboration Data Challenge (DC2) simulation for the Wide-Fast-Deep survey area. DC2 is the first large-scale (300 deg 2 ) image simulation of a transient survey that includes realistic cadence, variable observing conditions, and CCD image artifacts. We analyze ∼15 deg 2 of DC2 over a 5 yr time span in which artificial point sources from Type Ia supernova (SNIa) light curves have been overlaid onto the images. The magnitude limits per filter are u = 23.66 mag, g = 24.69 mag, r = 24.06 mag, i = 23.45 mag, z = 22.54 mag, and y = 21.62 mag. The artifact contamination levels are ∼90% of all detections, corresponding to ∼1000 artifacts deg –2 in g band, and falling to 300 deg –2 in y band. The photometry has biases <1% for magnitudes 19.5 < m < 23. Our DIA performance on simulated images is similar to that of the Dark Energy Survey difference-imaging pipeline on real images. We also characterize DC2 image properties to produce catalog-level simulations needed for distance bias corrections. We find good agreement between DC2 data and simulations for distributions of signal-to-noise ratio, redshift, and fitted light-curve properties. Applying a realistic SNIa cosmology analysis for redshifts z < 1, we recover the input cosmology parameters to within statistical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTRAL ENERGY DISTRIBUTIONS OF WEAK ACTIVE GALACTIC NUCLEI ASSOCIATED WITH LOW-IONIZATION NUCLEAR EMISSION REGIONS

We present a compilation of spectral energy distributions (SEDs) of 35 weak active galactic nuclei (AGNs) in low-ionization nuclear emission regions (LINERs) using recent data from the published literature. We make use of previously published compilations of data, after complementing and extending them with more recent data. The main improvement in the recent data is afforded by high-spatial-resolution observations with the Chandra X-Ray Observatory and high-spatial-resolution radio observations utilizing a number of facilities. In addition, a considerable number of objects have been observed with the Hubble Space Telescope in the near-IR through near-UV bands since the earlier compilations were published. The data include upper limits resulting from either non-detections or observations at low spatial resolution that do not isolate the AGN. For the sake of completeness, we also compute and present a number of quantities from the data, such as optical-to-X-ray spectral indices ({alpha}{sub ox}), bolometric corrections, bolometric luminosities, Eddington ratios, and the average SED. We anticipate that these data will be useful for a number of applications. In a companion paper, we use a subset of these data ourselves to assess the energy budgets of LINERs.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CCQE, 2p2h excitations and ν—energy reconstruction

We analyze the MiniBooNE muon neutrino CCQE-like dσ/dT{sub μ} d cos θ{sub μ} data using a theoretical model that, among other nuclear effects, includes RPA correlations and 2p2h (multinucleon) mechanisms. These corrections turn out to be essential for the description of the data. We find that MiniBooNE CCQE-like data are fully compatible with former determinations of the nucleon axial mass M{sub A} ∼ 1.05 GeV. This is in sharp contrast with several previous analysis where anomalously large values of M{sub A} ∼ 1.4 GeV have been suggested. We also show that because of the the multinucleon mechanism effects, the algorithm used to reconstruct the neutrino energy is not adequate when dealing with quasielastic-like events. Finally, we analyze the MiniBooNE unfolded cross section, and show that it exhibits an excess (deficit) of low (high) energy neutrinos, which is an artifact of the unfolding process that ignores 2p2h mechanisms.