Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

Combustion effects on film cooling

The effects of: (1) a reactive environment on film cooling effectiveness, and (2) film cooling on rocket engine performance were determined experimentally in a rocket thrust chamber assembly operating with hydrogen and oxygen propellants at 300 psi chamber pressure. Tests were conducted using hydrogen, helium, and nitrogen film coolants in an instrumented, thin walled, steel thrust chamber. The film cooling, performance loss, and heat transfer coefficient data were correlated with the ALRC entrainment film cooling model which relates film coolant effectiveness and mixture ratio at the wall to the amount of mainstream gases entrained with the film coolant in a mixing layer. In addition, a comprehensive thermal analysis computer program, HOCOOL, was prepared from previously existing ALRC computer programs and analytical techniques.

Rousar, D. C.↗

Effect of Fin Passage Length on Optimization of Cylinder Head Cooling Fins

The heat transfer performance of baffled cooling fins on cylinder heads of small, air-cooled, general-aviation aircraft engines was analyzed to determine the potential for improving cooling fin design. Flow baffles were assumed to be installed tightly against the fin end edges, an ideal baffle configuration for guiding all flow between the fins. A rectangular flow passage is thereby formed between each set of two adjacent fins, the fin base surface, and the baffle. These passages extend around each side of the cylinder head, and the cooling air absorbs heat as it flows within them. For each flow passage length, the analysis was concerned with optimizing fin spacing and thickness to achieve the best heat transfer for each fin width. Previous literature has been concerned mainly with maximizing the local fin conductance and has not considered the heating of the gas in the flow direction, which leads to higher wall temperatures at the fin passage exits. If the fins are close together, there is a large surface area, but the airflow is restricted.

Siegel, R.↗

Ambient temperature fatigue tests of elements of an actively cooled honeycomb sandwich structural panel

Elements of an actively cooled structural panel for a hypersonic aircraft have been investigated for fatigue characteristics. The study involved a bonded honeycomb sandwich panel with d-shaped coolant tubes. The curved portion of these tubes was embedded in the honeycomb, and the flat portion was bonded or soldered to the inner surface of the outer skin. The elements examined were two plain skin specimens (aluminum alloy); two specimens with skins attached to manifolds and tubes (one specimen was bonded, the other soldered); and a specimen representative of a corner section of the complete cooled sandwich. Sinusoidal loads were applied to all specimens. The honeycomb sandwich specimen was loaded in both tension and compression; the other specimens were loaded in tension only. The cooling tubes were pressurized with oil throughout the fatigue tests. The most significant results of these tests follow: All specimens exceeded their design life of 20,000 cycles without damage. Crack growth rates obtained in the plain skin specimens were used to determine the crack growth characteristics of aluminum alloy. Cracks in skins either bonded or soldered to cooling tubes propagated past the tubes without penetration. The coolant tubes served as crack arresters and temporarily stopped crack growth when a crack reached a tube-skin interface. The honeycomb core demonstrated that it could contain leakage from a tube.

Sharpe, E. L.↗

The pressure and energy balance of the cool corona over sunspots

The 22 largest sunspots observed with the Skylab SO55 spectrometer are studied for a relation between their EUV radiation and their umbral size or magnetic classification. The ultimate goal is to determine why the coronal plasma is so cool over a sunspot and how this cool plasma manages to support itself against gravity. Based on the time behavior of the EUV emission, a steady-state model is developed for the pressure and energy balance of the cool coronal-plasma loops over the spots. Analysis of the temperature structure in a typical loop indicates that the loop is exceedingly well insulated from the outside corona, that its energy balance is determined purely by internal heating and cooling processes, and that a heat input of about 0.0001 erg/cu cm per sec is required along the full length of the loop. It is proposed that: (1) coronal material flows steadily across the field lines at the tops of the loops and falls downward along both sides under gravity; (2) the corona is heated by mechanical-energy transport across the very thin transition region immediately over network-cell interiors; and (3) strong magnetic fields tend to inhibit mechanical-energy dissipation in the corona.

Foukal, P. V.↗

Finite-element methodology for thermal analysis of convectively cooled structures

A finite-element method for steady-state thermal analysis of convectively cooled structures is presented. The method is based on representing the coolant passages by finite elements with fluid bulk temperature nodes and fluid/structure interface modes. Four finite elements are described: two basic elements (mass transport and surface convection) and two integrated elements for applications to discrete tube and plate-fin convectively cooled structural configurations. Comparative finite-element and lumped-parameter thermal analyses of several convectively cooled structures demonstrate the practicality of utilizing finite-element methodology for thermal analysis of realistic convectively cooled structures.

Source record↗

The Jovian surface condition and cooling rate

A theory which is almost fully analytic is used to investigate Jupiter's cooling rate. A simple model of contraction with adiabatic interior structure gives a total cooling time to the present in good agreement with the age of the solar system. The interplay between the surface condition and the cooling rate is discussed. The current rate of change of the effective temperature is calculated to be -1 K per 0.145 billion yr. Discrepancies with fully numerical investigations of the Jovian age and cooling rate are noted.

Hubbard, W. B.↗

Cyclic structural analyses of air-cooled gas turbine blades and vanes

The creep-fatigue behavior of a fully impingement-cooled blade for four cyclic cases was analyzed by using the Elas 55, finite-element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of Strainrange Partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange Partitioning was also applied to previous results from a one-dimensional cyclic analysis of a film-impingement-cooled vane. The analyses indicated that Strainrange Partitioning is more applicable to a constrained airfoil such as the film-impingement-cooled vane than to the relatively unconstrained fully impingement-cooled airfoil.

Kaufman, A.↗

Computation of the temperature distribution in cooled radial inflow turbine guide vanes

A two-dimensional finite-difference numerical technique is presented to determine the temperature distribution of an internally-cooled blade of radial turbine guide vanes. A simple convection cooling is assumed inside the guide vane. Such an arrangement results in relatively small cooling effectiveness at the leading edge and at the trailing edge. Heat transfer augmentation in these critical areas may be achieved by using impingement jets and film cooling. A computer program is written in Fortran IV for IBM 370/165 computer.

Tabakoff, W.↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

Cooling of a sunspot

The question of whether a perturbed photospheric area can grow into a region of reduced temperature resembling a sunspot is investigated by considering whether instabilities exist that can lead to a growing temperature change and corresponding magnetic-field concentration in some region of the photosphere. After showing that Alfven cooling can lead to these instabilities, the effect of a heat sink on the temperature development of a perturbed portion of the photosphere is studied. A simple form of Alfven-wave cooling is postulated, and computations are performed to determine whether growing modes exist for physically relevant boundary conditions. The results indicate that simple inhibition of convection does not give growing modes, but Alfven-wave production can result in cooling that leads to growing field concentration. It is concluded that since growing instabilities can occur with strong enough cooling, it is quite possible that energy loss through Alfven waves gives rise to a self-generating temperature change and sunspot formation.

Boruta, N.↗

Measured effects of coolant injection on the performance of a film cooled turbine

Tests have been conducted on a 20-inch diameter single-stage air-cooled turbine designed to evaluate the effects of film cooling air on turbine aerodynamic performance. The present paper reports the results of five test configurations, including two different cooling designs and three combinations of cooled and solid airfoils. A comparison is made of the experimental results with a previously published analytical method of evaluating coolant injection effects on turbine performance.

Mcdonel, J. D.↗

System design package for the solar heating and cooling central data processing system

The central data processing system provides the resources required to assess the performance of solar heating and cooling systems installed at remote sites. These sites consist of residential, commercial, government, and educational types of buildings, and the solar heating and cooling systems can be hot-water, space heating, cooling, and combinations of these. The instrumentation data associated with these systems will vary according to the application and must be collected, processed, and presented in a form which supports continuity of performance evaluation across all applications. Overall software system requirements were established for use in the central integration facility which transforms raw data collected at remote sites into performance evaluation information for assessing the performance of solar heating and cooling systems.

Source record↗

Preliminary design package for solar heating and cooling systems

Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

Source record↗

Analysis of metal temperature and coolant flow with a thermal-barrier coating on a full-coverage-film-cooled turbine vane

The potential benefits of combining full-coverage film cooling with a thermal-barrier coating were investigated analytically for sections on the suction and pressure sides a high-temperature, high-pressure turbine vane. Metal and ceramic coating temperatures were calculated as a function of coating thickness and coolant flow. With a thermal-barrier coating, the coolant flows required for the chosen sections were half those of an uncoated design, and the metal outer temperatures were simultaneously reduced by over 111 K (200 F). For comparison, transpiration cooling was also investigated. Full-coverage film cooling of a coated vane required more coolant flow than did transpiration cooling.

Meitner, P. L.↗

Effects of film injection on performance of a cooled turbine

Some of the most dramatic increases in the performance of turbojet and turbofan aircraft engines have been obtained as a result of increased thermodynamic cycle temperatures made possible by the use of film cooling techniques. The realization of the potential performance gains, however, is only possible if the quantity of cooling air and the aerodynamic mixing losses resulting from the injection of coolant in the form of film on the flowpath surfaces are minimized. Such a minimization requires a more complete understanding of the relationship between cooling and aerodynamics. A review is conducted of tests which have been conducted to determine the effects of coolant injection on turbine performance. The results obtained in the tests are compared with an analytical technique developed for predicting coolant injection effects. Particular attention is given to the effects of turbine cooling on overall cycle thermodynamic efficiency, taking into account incremental changes in turbine thermodynamic efficiency for various incremental changes in coolant flow rate.

Mcdonel, J. D.↗

Cooling rate estimations based on kinetic modelling of Fe-Mg diffusion in olivine

A finite one-dimensional kinetic model was developed to estimate the cooling rates of lunar rocks. The model takes into consideration the compositional zonation of olivine and applies Buening and Buseck (1973) data on ion diffusion in olivine. Since the 'as-solidified' profile of a given olivine is not known, a step-function, with infinite gradient, is assumed; the position of this step is based on mass balance considerations of the measured compositional profile. A minimum cooling rate would be associated with the preservation of a given gradient. The linear cooling rates of lunar rocks 12002 and 15555 were estimated by use of the olivine cooling-rate indicator to be 10 C/day and 5 C/day, respectively. These values are lower than those obtained by dynamic crystallization studies (10-20 C/day).

Taylor, L. A.↗

Cooling rates for lunar samples determined with a diffusion model for phosphide exsolution

A numerical model for diffusion-controlled phase growth has been applied to the exsolution of phosphide lamellae in lunar metal grains. Computer simulations reproduce observed composition profiles, and reveal the influence of cooling rate on dimensional and compositional parameters of phosphide and metal. At lower cooling rates, phosphide lamellae are larger and the concentration of P in the metal host close to the interface is lower. Cooling rates inferred for Apollo 16 samples, based on compositions and dimensions of the phosphide-metal grains, are mostly in the range 1-100 C/day. These rates correspond to burial depths of 5-0.5 m for melt rocks and 3-0.3 m for breccias. This is in good agreement with thicknesses of lunar cooling units determined by other techniques.

Hewins, R. H.↗