Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Active control of panel vibrations induced by boundary-layer flow

Some problems in active control of panel vibration excited by a boundary layer flow over a flat plate are studied. In the first phase of the study, the optimal control problem of vibrating elastic panel induced by a fluid dynamical loading was studied. For a simply supported rectangular plate, the vibration control problem can be analyzed by a modal analysis. The control objective is to minimize the total cost functional, which is the sum of a vibrational energy and the control cost. By means of the modal expansion, the dynamical equation for the plate and the cost functional are reduced to a system of ordinary differential equations and the cost functions for the modes. For the linear elastic plate, the modes become uncoupled. The control of each modal amplitude reduces to the so-called linear regulator problem in control theory. Such problems can then be solved by the method of adjoint state. The optimality system of equations was solved numerically by a shooting method. The results are summarized.

Chow, Pao-Liu↗

Development of a Dynamic, End-to-End Free Piston Stirling Convertor Model

A dynamic model for a free-piston Stirling convertor is being developed at the NASA Glenn Research Center. The model is an end-to-end system model that includes the cycle thermodynamics, the dynamics, and electrical aspects of the system. The subsystems of interest are the heat source, the springs, the moving masses, the linear alternator, the controller, and the end-user load. The envisioned use of the model will be in evaluating how changes in a subsystem could affect the operation of the convertor. The model under development will speed the evaluation of improvements to a subsystem and aid in determining areas in which most significant improvements may be found. One of the first uses of the end-toend model will be in the development of controller architectures. Another related area is in evaluating changes to details in the linear alternator.

Regan, Timothy F.↗

Testing of Participant's Power Electronics Component for Circuit Performance and Efficiency (CRADA Final Report)

The "Solar SEED Smart Controller is a charge control device to condition solar power to load voltage with or without Battery (also called a "DC Power Platform") invented by David Gibbs and T4D Labs Inc. T4D Inc. and the SEED Smart Controller invention were selected for American Made Challenges Solar Prize, which includes voucher for NREL to provide technical assistance.

14 SOLAR ENERGY↗

Some experiences with active control of aeroelastic response

Flight and wind tunnel tests were conducted and multidiscipline computer programs were developed as part of investigations of active control technology conducted at the NASA Langley Research Center. Unsteady aerodynamics approximation, optimal control theory, optimal controller design, and the Delta wing and DC-10 models are described. The drones for aerodynamics and structural testing (DAST program) for evaluating procedures for aerodynamic loads prediction and the design of active control systems on wings with significant aeroelastic effects is described as well as the DAST model used in the wind tunnel tests.

Newsom, J. R.↗

Investigation of Injector Slot Geometry on Curved-Diffuser Aerodynamic Performance

The Compressor Branch vision is to be recognized as world-class leaders in research for fluid mechanics of compressors. Its mission is to conduct research and develop technology to advance the state of the art of compressors and transfer new technology to U.S. industries. Maintain partnerships with U.S. industries, universities, and other government organizations. Maintain a balance between customers focused and long range research. Flow control comprises enabling technologies to meet compression system performance requirements driven by emissions and fuel reduction goals (e.g., in UEET), missions (e.g., access-to-space), aerodynamically aggressive vehicle configurations (e.g., UAV and future blended wing body configurations with highly distorted inlets), and cost goals (e.g., in VAATE). The compression system requirements include increased efficiency, power-to-weight, and adaptability (i.e., robustness in terms of wide operability, distortion tolerance, and engine system health and reliability). The compressor flow control task comprises efforts to develop, demonstrate, and transfer adaptive flow control technology to industry to increase aerodynamic loading at current blade row loss levels, to enable adaptive1 y wide operability, and to develop plant models for adaptive compression systems. In this context, flow control is the controlled modification of a flow field by a deliberate means beyond the natural (uncontrolled) shaping of the solid surfaces that define the principal flow path. The objective of the compressor flow control task is to develop and apply techniques that control circulation, aerodynamic blockage, and entropy production in order to enhance the performance and operability of compression systems for advanced aero-propulsion applications. This summer I would be working with a curved-diffuser because it simulates what happens with flow in the stator blades in the compressor. With this experiment I will be doing some data analysis and parametric study of the injector slot geometries to get the best aerodynamic performance of it. This includes some data reduction, redesign and fast prototyping of the injector nozzle.

Silva, Odlanier↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intelligent control of a multi-degree-of freedom reaction compensating platform system using fuzzy logic

This paper presents the development of a general-purpose fuzzy logic (FL) control methodology for isolating the external vibratory disturbances of space-based devices. According to the desired performance specifications, a full investigation regarding the development of an FL controller was done using different scenarios, such as variances of passive reaction-compensating components and external disturbance load. It was shown that the proposed FL controller is robust in that the FL-controlled system closely follows the prespecified ideal reference model. The comparative study also reveals that the FL-controlled system achieves significant improvement in reducing vibrations over passive systems.

Choi, Benjamin B.↗

Aerodynamic Characteristics of a Large-Scale Unswept Wing-Body-Tail Configuration with Blowing Applied Over the Flap and Wind Leading Edge

An investigation has been conducted in the Langley full-scale tunnel to determine the effects of a blowing boundary-layer-control lift-augmentation system on the aerodynamic characteristics of a large-scale model of a fighter-type airplane. The wing was unswept at the 70-percent- chord station, had an aspect ratio of 2.86, a taper ratio of 0.40, and 4-percent-thick biconvex airfoil sections parallel to the plane of symmetry. The tests were conducted over a range of angles of attack from approximately -4 deg to 23 deg for a Reynolds number of approximately 5.2 x 10(exp 6) which corresponds to a Mach number of 0.08. Blowing rates were normally restricted to values just sufficient to control air-flow separation. The results of this investigation showed that wing leading-edge blowing in combination with large values of wing leading-edge-flap deflection was a very effective leading-edge flow-control device for wings having highly loaded trailing-edge flaps. With leading-edge blowing there was no hysteresis of the lift, drag, and pitching-moment characteristics upon recovery from stall. End plates were found to improve the lift and drag characteristics of the test configuration in the moderate angle-of-attack range, and blockage to one-quarter of the blowing-slot area was not detrimental to the aerodynamic characteristics. Blowing boundary-layer control resulted in a considerably reduced landing speed and reduced landing and take-off distances. The ailerons were very effective lateral-control devices when used with blowing flaps.

McLemore, H. Clyde↗

Flywheel energy storage for electromechanical actuation systems

The authors describe a flywheel energy storage system designed specifically to provide load-leveling for a thrust vector control (TVC) system using electromechanical actuators (EMAs). One of the major advantages of an EMA system over a hydraulic system is the significant reduction in total energy consumed during the launch profile. Realization of this energy reduction will, however, require localized energy storage capable of delivering the peak power required by the EMAs. A combined flywheel-motor/generator unit which interfaces directly to the 20-kHz power bus represents an ideal candidate for this load leveling. The overall objective is the definition of a flywheel energy storage system for this application. The authors discuss progress on four technical objectives: (1) definition of the specifications for the flywheel-motor/generator system, including system-level trade-off analysis; (2) design of the flywheel rotor; (3) design of the motor/generator; and (4) determination of the configuration for the power management system.

Hockney, Richard L.↗

Stability and Control Characteristics of a Model of an Aerial Vehicle Supported by Four Ducted Fans

The stability and control characteristics of a simple, lightly loaded model approximately one-third the size of a full-scale vehicle have been investigated by a series of free-flight tests. The model is representative of a type of vertically rising aircraft which would utilize four ducted fans as its sole source of lift and propulsion. The ducts were arranged in a rectangular pattern and were fixed to the airframe so that their axes of revolution were vertical for hovering flight. Control moments were provided by remotely controlled compressed-air jets at the sides and ends of the model. In hovering, the model in its original configuration exhibited divergent oscillations about both the roll and pitch axes. Because these oscillations were of a rather short period., the model was very difficult to control by the use of remote controls only. The model could be completely stabilized by the addition of a sufficient amount of artificial damping. The pitching oscillation was made easier to control by increasing the distance between the forward and rearward pairs of ducts. In forward flight, with the model in its original configuration, the top speed was limited by the development of an uncontrollable pitch-up. Large forward tilt angles were required for trim at the highest speeds attained. With the model rotated so that the shorter axis became the longitudinal axis, the pitch trim problem was found to be less than with the longer axis as the longitudinal axis. The installation of a system of vanes in the slipstream of the forward ducts reduced the tilt angle but increased the power required.

Parlett, Lysle P.↗

Self-reconfiguring solar cell system

A self-reconfiguring solar cell array is disclosed wherein some of the cells are switched so that they can be either in series or in shunt within the array. This feature of series or parallel switching of cells allows the array to match the load to achieve maximum power transfer. Automatic control is used to determine the conditions for maximum power operation and to switch the array into the appropriate configuration necessary to transfer maximum power to the load.

Gruber, R. P.↗

A higher harmonic control test in the DNW to reduce impulsive BVI noise

A model rotor acoustic test was performed to examine the benefit of higher control (HHC) of blade pitch to reduce blade-vortex interaction (BVI) impulse noise. A 40-percent dynamically scaled, four-bladed model of a BO-105 main rotor was tested in the German-Dutch Wind Tunnel (DNW). Acoustic measurements were made in a large plane underneath the rotor employing a traversing in-flow microphone array in the anechoic environment of the open test section. Noise characteristics and noise directivity patterns as well as vibratory loads were measured and used to demonstrate the changes when different HHC schedules (different modes, amplitudes, phases) were applied. Dramatic changes of the acoustic signatures and the noise radiation directivity with HHC phase variations are found. Compared to the baseline conditions (without HHD), significant mid-frequency noise reductions of as much as 6 dB are obtained for low speed descent conditions where BVI is most intensive. For other rotor operating conditions with less intense BVI there is less or no benefit from the use of HHC. Low frequency loading noise and vibratory loads, especially at optimum noise reduction control settings, are found to increase.

Splettstoesser, Wolf R.↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Upper troposphere dust belt formation processes vary seasonally and spatially in the Northern Hemisphere

Dust aerosols impact global energy balance substantially by acting as efficient ice nuclei to alter cold cloud properties. However, the estimate of dust indirect effect remains uncertain due to simulating dust distributions poorly and lacking reliable dust observations, especially in the upper-troposphere. Here, we characterize and understand upper-troposphere dust sources and transport with an improved dust dataset derived from A-train satellite lidar and radar measurements and an air parcel trajectory model. The distinct upper-troposphere dust belt over the northern hemisphere has seasonally varying base and top heights of 3.65 ± 2.84 and 8.35 ± 1.50 km above mean sea level and its column loading is strongest during spring (March-April-May). The out-of-phase annual cycles of mid-level dust concentration and westerly wind over source regions control the seasonal upper-tropospheric dust loading variations. African deserts contribute the most (46.3%) to the upper-troposphere dust belt in spring and the synoptic trough is the leading (49%) dust lifting mechanism.

54 ENVIRONMENTAL SCIENCES↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗