Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Transparent switchboard

A tin oxide coating is formed on a plate of glass and the coating is then etched away from the glass in thin lines to form separate electrical conductors which extend to one end of the plate and connect to either a vertical (column) or horizontal (row) position sensing SCR circuit. A thin transparent insulating coating is formed over the oxide layer except at selected touch points which are positioned in a matrix pattern of vertical columns and horizontal rows. Touching one of these points with a finger bridges the thin line between adjacent conductors to activate trigger circuits in the particular row and column sensing circuits associated with the point touched. The row and column sensing circuits are similar and are powered with a low frequency, ac voltage source. The source for the row circuits is 180 out of phase with the source for the column circuits so that one circuit acts as ground for the other during half of the supply voltage cycle. The signals from the sensing circuits are input to a logic circuit which determines the presence of a valid touch, stores a binary matrix number associated with the touched point, signals a computer of the presence of a stored number and prevents storage of a new number before receiving an enable signal from the computer.

Rasmussen, H. P.↗

Jupiter's great red spot revisited

On the original Taylor column theory of Jupiter's Great Red Spot, the fixed latitude of the Spot is taken to imply that the Taylor column in Jupiter's atmosphere is associated with a disturbance such as a topographic feature of the surface Q underlying the atmosphere. The alternative suggestion that the Taylor column is produced by a solid raft floating at depth in the atmosphere is somewhat easier to reconcile with the approximately 10s difference between the respective rotation periods P sub S and P sub R of the Red Spot and of the radio sources, but it does not account so readily for the fixed latitude of the Spot unless it can be shown that the raft is in stable equilibrium under the north-south components of the dynamical forces, including wind effects, acting upon it. A slight wavering of the upper end of the Taylor column relative to the lower end could account at least in part for the most rapid variations in P sub S, but the slow large-amplitude variations in P sub S must reflect changes in the longitudinal motion of either the surface Q or of the raft. By generalizing the Proudman-Taylor theorem to the case of a non-homogeneous fluid it is shown that the Taylor column theory does not imply very special and therefore unlikely horizontal and vertical temperature variations in Jupiter's atmosphere, thus refuting a widely-held belief to the contrary.

Hide, R.↗

Research on miniature gas analysis systems

Technology for fabricating very small valves, whose function will be to introduce a small sample of the gas to be analyzed into the main carrier gas stream flowing through the chromatograph column is described. In addition, some analyses were made of the factors governing the resolution of gas chromatographs, particularly those with miniature columns. These analyses show how important the column lining thickness is in governing the ability of a miniature column to separate components of an unknown gas. A brief description of column lining factors is included. Preliminary work on a super small thermistor detector is included.

Angell, J. B.↗

Flight contaminant trace analyser. Phase 1: Chromatographic input system

The purpose of this investigation was to develop two chromatographic columns which would enable a mass spectral identification of 40 specified compounds. The columns are for use in a toxic gas analyzer, which incorporates an automated gas chromatograph-mass spectrometer. Different types of stationary phases were investigated. The columns used were of the open tubular capillary type and were made of nickel. Limitations of initial and final temperature of operation led to final development of a column which could resolve most of the compounds required. The few unresolved components are capable of resolution and identification by the mass spectrometer. The columns (182m Ni x 0.8m 0.D x 0.5mm I.D) coated with Witconal La 23, yielded in excess of 200,000 theoretical plates and completed the analysis in less than 90 minutes using a carrier gas flow rate of 4 cc/min hydrogen.

Zlatkis, A.↗

The interstellar medium in the line of sight to X Persei and 3U 0352+30

The X-ray absorption column of 3U 0352+30 obtained with the Copernicus X-ray telescopes is compared with the atomic and molecular hydrogen column densities in the line of sight to X Per, as measured with the Copernicus ultraviolet telescopes, and with the visible reddening of X Per, by means of reddening/X-ray absorption-column relationships. The results are consistent with both the star and X-ray source being equidistant. When comparing X-ray absorbing column densities with those derived by other means, it is necessary to include the effects of molecular hydrogen in the line of sight to X Per and, in particular, the related number of medium-weight elements. It is suggested that failure to do this in previous work may account for reported discrepancies between the X-ray and radio column densities to the Crab Nebula and other sources. The far-ultraviolet extinction curve of X Per is presented.

Mason, K. O.↗

A survey of interstellar molecular hydrogen. I

Data from the Copernicus satellite's ultraviolet telescope were used to survey column densities of atomic and molecular hydrogen from a large sample of early-type stars; these data have bearing on an eventual understanding of diffuse and dense interstellar clouds. Column densities are derived by fitting damping profiles to the observed spectra, most of which exhibit strong damping lines in the lower rotational levels surveyed. Plots of dust column density, fractional abundance of molecular hydrogen, and the logarithm of fractional abundance versus total gas column density are given for many of the stars; stars with abnormally large or small hydrogen column densities, as well as some distant stars at high galactic latitudes, are considered. Equilibrium and nonequilibrium theories accounting for the abundance of interstellar hydrogen are compared, and support is found in the data for an account which balances hydrogen formation on interstellar grains with destruction through photodissociation. Overall averages for atomic and molecular hydrogen levels in the galactic plane are also calculated.

Savage, B. D.↗

Interstellar titanium

High-dispersion photoelectric scans of the interstellar 3384-A line of Ti II have been obtained for 68 stars. Column densities of Ti II are derived for the various individual kinematic components in the scans. These column densities, and those integrated over all components in the respective directions, are compared with corresponding results for Na I, Ca II, K I, H I, and H2. The column densities of titanium and hydrogen show directly that the depletion of titanium from the interstellar gas is large and variable. The abundance of titanium in the gas also varies strongly relative to the Na, K, and the grains responsible for reddening. In contrast, the titanium/calcium column-density ratio is relatively constant at about 4 times its solar value. Lower depletions are found in four out of five cases of absorption in the intercloud medium and toward each of two stars at high galactic z-distances. The column densities of Ca II and Ti II are used to estimate the electron densities in individual kinematic components. These electron densities are uncorrelated with the depletions of titanium, indicating that depletion is not a simple or unique function of local density.

Stokes, G. M.↗

Electrophoretic fractional elution apparatus employing a rotational seal fraction collector

Electrophoretic fractional elution apparatus which has a column with a rotating seal joint is described. A thin jet of eluting buffer is directed across the lumen of the electrophoretic column in a direction perpendicular to that of electrophoretic migration. Either the content of the column is rotated with respect to the stationary jet, or the jet is rotated with respect to the column. The system may employ electrophoresis either in free solution or in packed columns.

Bier, M.↗

The relationship between carbon monoxide abundance and visual extinction in interstellar clouds

Carbon monoxide column densities are compared to visual extinctions toward field stars in the rho Oph and Taurus molecular cloud complexes. The relationship of C(0-18) column density to extinction is established, and new determinations for (C-13)O column densities are given for a range of visual extinctions extended to beyond 20 mag. A prescription for determining hydrogen column densities and masses of molecular clouds from observations of CO isotopes is presented and discussed critically. These measurements agree well with the predictions of gas phase chemistry models which include chemical fractionation and selective isotopic photodestruction. The functional dependence of the C(O-18) column density on extinction is characterized by two different regimes separated by a distinct transition observed to occur at 4 mag in both molecular cloud complexes, whereas the functional dependence of (C-13)O is quite different in the two regions. Some saturation is found to occur for C(O-18) emission at high visual extinction and use the rarer isotopic species C(O-17) and (C-13)(O-18) to correct for it.

Frerking, M. A.↗

Molecule formation in quasar broad-line cloud gas

Models for the broad-line emitting clouds of quasars typically assume that the clouds have column densities of at most 10 to the 23rd/sq cm. The consequences of relaxing this assumption are examined, and it is shown that: (1) at slightly larger column densities the gas may cool to about 1000 K as a result of molecule formation; (2) in much of the molecule-forming region the temperature may have either of two values, about 1000 K or 6000-8000 K; (3) the strengths of most observable optical lines, including C II semiforbidden 2326-A lines and Fe II lines, are unaffected by such large column densities; and (4) lines from low-ionization species such as Na I are readily formed at large column densities. Observations of such lines provide evidence for large cloud column densities.

Kallman, T.↗

Interstellar C2, CH, and CN in translucent molecular clouds

Optical absorption-line techniques have been applied to the study of a number of translucent molecular clouds in which the total column densities are large enough that substantial molecular abundances can be maintained. Results are presented for a survey of absorption lines of interstellar C2, CH, and CN. Detections of CN through the A 2Pi-X 2Sigma(+) (1,O) and (2,O) bands of the red system are reported and compared with observations of the violet system for one line of sight. The population distributions in C2 provide diagnostic information on temperature and density. The measured column densities of the three species can be used to test details of the theory of molecule formation in clouds where photoprocesses still play a significant role. The C2 and CH column densities are strongly correlated with each other and probably also with the H2 column density. In contrast, the CN column densities are found to vary greatly from cloud to cloud. The observations are discussed with reference to detailed theoretical models.

Black, John H.↗

Golay and other box codes

The (24,12;8) extended Golay Code can be generated as a 6 x 4 binary matrix from the (15,11;3) BCH-Hamming Code, represented as a 5 x 3 matrix, by adding a row and a column, both of odd or even parity. The odd-parity case provides the additional 12th dimension. Furthermore, any three columns and five rows of the 6 x 4 Golay form a BCH-Hamming (15,11;3) Code. Similarly a (80,58;8) code can be generated as a 10 x 8 binary matrix from the (63,57;3) BCH-Hamming Code represented as a 9 x 7 matrix by adding a row and a column both of odd and even parity. Furthermore, any seven columns along with the top nine rows is a BCH-Hamming (53,57;3) Code. A (80,40;16) 10 x 8 matrix binary code with weight structure identical to the extended (80,40;16) Quadratic Residue Code is generated from a (63,39;7) binary cyclic code represented as a 9 x 7 matrix, by adding a row and a column, both of odd or even parity.

Solomon, G.↗

Does UV instrumentation effectively measure ozone abundance?

Measurements of O3 on Mars provide significant information about the chemistry and composition of the atmosphere, including long-term changes. The most extensive and accurate data were inferred from the Mariner 9 UV spectrometer experiment. Mars O3 shows strong seasonal and latitudinal variation, with column abundances ranging from 0.2 microns at equatorial latitudes to 60 microns over the northern winter polar latitudes (1 micron-atm is a column abundance of 2.689 x 10(exp 15) molecules cm(exp-2)). The Mariner 9 UV spectrometer scanned from 2100 to 3500 Angstroms in one of its two spectral channels every 3 seconds with a spectral resolution of 15 Angstroms and an effective field-of-view of approximately 300 km(exp 2). Measurements were made for almost half a Martian year, with winter and spring in the Northern Hemisphere and summer and fall in the Southern Hemisphere. The detectability limit of the spectrometer was approximately 3 microns of ozone. The UV spectrometer on Mariner 9 was incapable of penetrating the dust during dust storms; the single-scattering albedo and phase function of airborne dust and cloud ice are not known to the degree required to extract the small UV signal reflected up from near the surface. The reflectance spectroscopy technique would also have difficulty detecting the total column abundance of O3 in cases where large dust abundances exist together with the polar hood, especially at high latitudes where large solar zenith angles magnify those optical depths; yet these cases would contain the maximum O3, based on theoretical results. It is quite possible that the maximum O3 column abundance observed by Mariner 9 of 60 microns is common. In fact, larger quantities may exist in some of the colder areas with optically thick clouds and dust. As the Viking period often had more atmospheric dust loading than did that of Mariner 9, the reflectance spectroscopy technique may even have been incapable of detecting the entire O3 column abundance during much of the Mars year that Viking observed, particularly at high latitudes.

Lindner, Bernhard Lee↗

Unit operations for gas-liquid mass transfer in reduced gravity environments

Basic scaling rules are derived for converting Earth-based designs of mass transfer equipment into designs for a reduced gravity environment. Three types of gas-liquid mass transfer operations are considered: bubble columns, spray towers, and packed columns. Application of the scaling rules reveals that the height of a bubble column in lunar- and Mars-based operations would be lower than terrestrial designs by factors of 0.64 and 0.79 respectively. The reduced gravity columns would have greater cross-sectional areas, however, by factors of 2.4 and 1.6 for lunar and Martian settings. Similar results were obtained for spray towers. In contract, packed column height was found to be nearly independent of gravity.

Pettit, Donald R.↗

Micro-apparatus for rapid determinations of protein solubilities

We have developed a column-based micro-technique for rapid determinations of protein solubilities. While retaining a large crystal surface area, the column dead volume has been reduced to equal to or less than 5 micro liters. The technique was tested with tetragonal lysozyme (pH 4.5, 0.1 M acetate, 3.0 percent NaCl, 5-25 C) and column volumes of about 60, 300, and 900 micro liters. Identical solubility data were obtained, indicating that equilibration was obtained even in the smallest columns. In addition, solubility data for Br- and I- salts of lysozyme (pH 4.5, 0.1 M acetate buffer, 0.5 M salt concentrations) were obtained. It appears that the technique can be further miniaturized. The limit in further reducing the crystalline column volume is determined by the minimum solution sample size needed to determine the protein concentration.

Pusey, Marc L.↗

Measurements of stratospheric odd nitrogen at Arrival Heights, Antarctica, in 1991

An FTIR spectrometer was installed at Arrival Heights, Antarctica (78 deg S, 167 deg E) in February 1991 to measure the evolution of stratospheric HNO3 during the year. In particular, it was the intention to make the first observations of HNO3 trends during autumn, concurrently with ongoing measurements of column NO2 made with a grating spectrometer. The time-series of NO2 in the Antarctic shows a rapid decline in the column amount during autumn, and a slow recovery in spring, as the photochemical conditions move the species to and from higher storage reservoirs. The new nitric acid data show for the first time that during autumn the vertical column increases from approximately 1.9 x 10(exp 16) molecule cm(exp -2) at day 30 to approximately 3.1 x 10(exp 16) molecule cm(exp -2) by day 100. When the sun returns in spring, it is found that the column amount has fallen to about half the value at the end of autumn. Spring amounts are variable, but as found in the data from previous years remain low inside the vortex. The autumn increase is attributed to the heterogeneous conversion of N2O5 to gas-phase HNO3 on background aerosols. Low nitric acid column amounts at the start of spring suggest that the HNO3 has moved from the gas to the condensed phase on polar stratospheric clouds with the advent of low temperatures during the polar night.

Keys, J. Gordon↗

Effects of the Mount Pinatubo eruption on the radiative and chemical processes in the troposphere and stratosphere

The Lawrence Livermore National Laboratory two-dimensional zonally-averaged chemical-radiative-transport model of the global atmosphere was used to study the effects of the 15 June 1991 eruption of the Mt. Pinatubo volcano on stratospheric processes. SAGE 2 time-dependent aerosol surface area density and optical extinction data were used as input into the model. By 22 December 1991, a maximum equatorial change of -1.8 percent in column ozone was derived from heterogeneous chemical processes that convert NO(x) into HNO3 on sulfuric acid aerosols. Radiative feedbacks from increased aerosol optical thickness independently changes column ozone by approximately -3.5 percent for the same period. This occurs from increasing the net heating of the lower stratosphere, which indirectly increases chemical reaction rates via their temperature dependence and from changes in actinic fluxes, which directly modify photodissociation rates. Including both heterogeneous and radiative effects changes column ozone by -5.5 percent. The model-derived change overestimates the decrease in column ozone relative to the TOMS instrument on the Nimbus 7 satellite. Maximum local ozone decreases of 12 percent were derived in the equatorial region, at 25 km. Model-derived column NO2 peaked (-14 percent) at 30 deg S in October 1991. The timing of the NO2 peak is consistent with observation, but the model underestimates the magnitude of the decrease. Local concentrations of NO(x) (NO + NO2), ClO(x) (Cl + ClO), and HO(x) (OH + HO2), in the lower stratosphere between 30 deg S and 30 deg N, were calculated to have changed by -40 percent, +100 to +160 percent, and +120 to +140 percent respectively.

Kinnison, Douglas E.↗

The chemical and radiative effects of the Mount Pinatubo eruption

To clarify the mechanisms leading to effects on stratospheric ozone, time-dependent stratospheric aerosol and gas experiment II (SAGE II) and cryogenic limb array elaton spectrometer (CLAES) aerosol optical extinction data and SAGE II surface area density are used as parameters in a two-dimensional (2-D) zonally averaged chemical radiative transport model. The model was integrated with time from before the eruption through December 1993. The modeled impact on global ozone results from increased rates of heterogeneous reactions on sulfate aerosols and from the increased radiative heating and scattering caused by these aerosols. When the aerosol heating is allowed to modify the temperature distribution, the maximum change calculated in equatorial column ozone is -1.6%. The calculated equatorial temperature change and peak local ozone change in October 1991 are +6K and -4%, respectively. When aerosol heating perturbs the circulation in the model, the maximum change in equatorial column ozone is -6%. Increased heterogeneous processing on sulfate aerosols is calculated to have changed equatorial column ozone in late 1991 by -1.5%. Global column ozone in the model in 1992 and 1993 changed by -2.8% and -2.4%, respectively. The relationship of ozone-controlling processes in the lower stratosphere is altered as well; HO(x) becomes the most important catalytic cycle, followed by ClO(x) and NO(x). This is driven by significant changes in trace gas concentrations. In October 1991, lower stratospheric, equatorial NO(x) decreased by 40%, ClO(x) increased by 60%, and HO(x) increased by 25%. When the effect of heterogeneous chemical processing on sulfate aerosols is combined with aerosol heating, modifying either circulation or temperature, dramatically different ozone fingerprints with time and latitude are predicted. Model-derived changes in the equatorial region in column ozone best represented the observed data when perturbed circulation was combined with heterogeneous chemical effects. However, at high latitudes, the increased ozone production from the strengthening of the mean circulation tends to cancel the heterogeneous reduction of ozone. This is not in good agreement with observed data, especially in 1992 and 1993. When the circulation is held fixed and the temperature allowed to change, and heterogeneous chemical effects are included, the equatorial ozone decrease predicted was too small for 1991. However, the mid- to high-latitude decrease in 1992 and 1993 is in better agreement with observed data.

Kinneson, Douglas E.↗