Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coded source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

60 APPLIED LIFE SCIENCES↗

MCNP6 Elevation Scaling of Cosmic Ray Backgrounds - Paper 29

The galactic cosmic-ray (GCR) source option was implemented in the all-energy, all-particle transport code MCNP62 in 2010. This source option along with other newly added features to MCNP6 have been used to produce increasingly accurate global cosmic and terrestrial background flux data files (background.dat).3 This data file is produced on a grid and is read and sampled by MCNP6 whenever a user invokes the background source option. The most recent adaptation of this data file, Version 4, will be completed in 2014. This paper reports on current progress toward enhancements that have been made to the modeling and simulation of these background spectra, in particular the elevation scaling used to produce more accurate spectra at off-grid locations. Cosmic radiation continuously bombards Earth with various particles, such as protons, alpha particles, and heavier nuclei, some of which are deflected by the Earth's shielding magnetic field. Particles that carry sufficient momentum can overcome the deflection and penetrate into the atmosphere. The sufficient momentum is dependent on the terrestrial coordinates due to the shape of the Earth's magnetic field and the Lorentz force's proportionality to the sine of the angle between the velocity vector of the incoming particle and the magnetic field direction. As the particles propagate through the atmosphere, collisions with atmospheric molecules generate secondary particles such as neutrons, protons, photons, muons, pions, and other exotic particles. These secondary particles often have sufficient energy to undergo additional nuclear interactions, and so on, forming what is known as a cascade shower. The particles in the cascade shower are constantly undergoing energy losses due to interactions, especially charged particles whose paths are bent into helical trajectories around magnetic field lines. These energy losses make the integral flux of the cosmic background at the ground level highly dependent on the atmospheric depth traveled by the incident particle and its progeny, and therefore dependent on the elevation of the ground where the cascade deposits its energy. For relatively small depth changes of approximately 100 g/cm{sup 2} or less, the ground-level cosmic flux follows an exponential model. The tabulation of background particle fluxes on the surface of the earth is important for a variety of reasons, one of which is the design of nuclear material detection systems. This method is also useful in producing user-specified effective attenuation lengths for particles. Attenuation lengths are an essential parameter used to compare particle spectra from different locations, elevations, and energy ranges. Traditionally these attenuation lengths are inferred from measured data. Now with the ability to simulate an accurate galactic cosmic ray source and transport it and its shower through a modeled atmosphere, these attenuation lengths can be calculated for any set of conditions. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

An Open-Source Numerical Model for Mitigating Refractory Alloy Hot Cracking Susceptibility

Refractory alloys are susceptible to solidification cracking during welding and 3D printing. Composition control is an effective method of controlling solidification cracking. This work evaluates the effect of compositional variation in refractory metal systems on a computed solidification cracking susceptibility. A numerical model has been developed using Python code and open-source CALPHAD software to calculate Kou’s crack susceptibility index. The model is validated against past weldability studies performed on several refractory alloy systems. The approach is extended towards the development of new alloys with improved 3D printability and weldability and is shown to have utility in defining compositional limits for existing alloys and feedstocks. Furthermore, the model will aid in determining process controls for powder reuse and recycling.

pycalphad↗

SE-FIT

The mathematical theory of capillary surfaces has developed steadily over the centuries, but it was not until the last few decades that new technologies have put a more urgent demand on a substantially more qualitative and quantitative understanding of phenomena relating to capillarity in general. So far, the new theory development successfully predicts the behavior of capillary surfaces for special cases. However, an efficient quantitative mathematical prediction of capillary phenomena related to the shape and stability of geometrically complex equilibrium capillary surfaces remains a significant challenge. As one of many numerical tools, the open-source Surface Evolver (SE) algorithm has played an important role over the last two decades. The current effort was undertaken to provide a front-end to enhance the accessibility of SE for the purposes of design and analysis. Like SE, the new code is open-source and will remain under development for the foreseeable future. The ultimate goal of the current Surface Evolver Fluid Interface Tool (SEFIT) development is to build a fully integrated front-end with a set of graphical user interface (GUI) elements. Such a front-end enables the access to functionalities that are developed along with the GUIs to deal with pre-processing, convergence computation operation, and post-processing. In other words, SE-FIT is not just a GUI front-end, but an integrated environment that can perform sophisticated computational tasks, e.g. importing industry standard file formats and employing parameter sweep functions, which are both lacking in SE, and require minimal interaction by the user. These functions are created using a mixture of Visual Basic and the SE script language. These form the foundation for a high-performance front-end that substantially simplifies use without sacrificing the proven capabilities of SE. The real power of SE-FIT lies in its automated pre-processing, pre-defined geometries, convergence computation operation, computational diagnostic tools, and crash-handling capabilities to sustain extensive computations. SE-FIT performance is enabled by its so-called file-layer mechanism. During the early stages of SE-FIT development, it became necessary to modify the original SE code to enable capabilities required for an enhanced and synchronized communication. To this end, a file-layer was created that serves as a command buffer to ensure a continuous and sequential execution of commands sent from the front-end to SE. It also establishes a proper means for handling crashes. The file layer logs input commands and SE output; it also supports user interruption requests, back and forward operation (i.e. undo and redo), and others. It especially enables the batch mode computation of a series of equilibrium surfaces and the searching of critical parameter values in studying the stability of capillary surfaces. In this way, the modified SE significantly extends the capabilities of the original SE.

Chen, Yongkang↗

Initial Integration of Noise Prediction Tools for Acoustic Scattering Effects

This effort provides an initial glimpse at NASA capabilities available in predicting the scattering of fan noise from a non-conventional aircraft configuration. The Aircraft NOise Prediction Program, Fast Scattering Code, and the Rotorcraft Noise Model were coupled to provide increased fidelity models of scattering effects on engine fan noise sources. The integration of these codes led to the identification of several keys issues entailed in applying such multi-fidelity approaches. In particular, for prediction at noise certification points, the inclusion of distributed sources leads to complications with the source semi-sphere approach. Computational resource requirements limit the use of the higher fidelity scattering code to predict radiated sound pressure levels for full scale configurations at relevant frequencies. And, the ability to more accurately represent complex shielding surfaces in current lower fidelity models is necessary for general application to scattering predictions. This initial step in determining the potential benefits/costs of these new methods over the existing capabilities illustrates a number of the issues that must be addressed in the development of next generation aircraft system noise prediction tools.

Nark, Douglas M.↗

EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 {sup 137}Cs brachytherapy source models

Purpose: AAPM TG-56 recommends the use of a specific dosimetric dataset for each brachytherapy source model. In this study, a full dosimetric dataset for indigenously developed {sup 137}Cs source models, namely, the CSA1 and CSA2, in accordance with the AAPM TG-43U1 formalism is presented. The study includes calculation of dose-to-kerma ratio D/K in water around these sources including stainless steel encapsulated {sup 137}Cs sources such as RTR, 3M, and selectron/LDR {sup 137}Cs. Methods: The Monte Carlo-based EGSnrcMP code system is employed for modeling the sources in vacuum and in water. Calculations of air-kerma strength, S{sub K} for the investigated sources and collision kerma in water along the transverse axis of the RTR source are based on the FLURZnrc code. Simulations of water-kerma and dose in water for the CSA1, CSA2, RTR, 3M, and selectron/LDR {sup 137}Cs sources are carried out using the DOSRZnrc code. In DOSRZnrc calculations, water-kerma and dose are scored in a cylindrical water phantom having dimensions of 80 cm diameterx80 cm height. Results: The calculated dose-rate constants for the CSA1 and CSA2 sources are 0.945(1) and 1.023(1) cGy/(h U), respectively. The calculated value of S{sub K} per unit source activity, S{sub K}/A for the CSA1 and CSA2 sources is 7.393(7)x10{sup -8} cGy cm{sup 2}/(h Bq). The EGSnrcMP-based collision kerma rates for the RTR source along the transverse axis (0.25-10 cm) agree with the corresponding GEANT4-based published values within 0.5%. Anisotropy profiles of the CSA1 and CSA2 sources are significantly different from those of other sources. For the selectron/LDR single pellet {sup 137}Cs spherical source (modeled as a cylindrical pellet with dimensions similar to the seed selectron), the values of D/K at 1 and 1.25 mm from the capsule are 1.023(1) and 1.029(1), respectively. The value of D/K at 1 mm from the CSA1, CSA2, RTR, and 3M {sup 137}Cs source capsules (all sources have an external radius of 1.5 mm) is 1.017(1) and this ratio is applicable to axial positions z=0 to z={+-}L/2. This is in contrast to a published GEANT4-based Monte Carlo dosimetric study on RTR and 3M {sup 137}Cs sources wherein the authors have assumed that collision kerma is approximately equal to absorbed dose at 1 mm from the source capsules. Collision kerma is approximately equal to absorbed dose for distances {>=}2 mm from source capsules as opposed to {>=}1 mm reported in published studies. A detailed electron transport is necessary up to 2 mm from source capsules. Conclusions: The Monte Carlo-calculated dose-rate data for the CSA1 and CSA2 sources can be used as input data for treatment planning or to verify the calculations by radiotherapy treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a BlueCRAB/MELCOR Framework for Supporting Realistic Mechanistic Source Term Calculations in Microreactors

Efforts are currently underway to deploy microreactor modeling and simulation tools to better support vendors and regulatory authorities in submitting and reviewing licensing applications. In particular, the Nuclear Regulatory Commission is expected to rely on the Comprehensive Reactor Analysis Bundle (BlueCRAB) multiphysics toolset in performing design- and beyond-design-basis accident analyses. In addition, the Nuclear Regulatory Commission has been using the MELCOR code to estimate mechanistic source terms during accidents. As MELCOR relies on isotopic inventory and reactor temperature/power evolution profiles during accident conditions—all of which can theoretically be obtained from BlueCRAB—the ultimate goal of this activity is to establish a common BlueCRAB-MELCOR framework. However, prior to the present research, BlueCRAB had never been used to calculate such quantities of interest at the full-core level. While there are many Monte Carlo (MC) codes capable of computing such quantities of interest, they are unable to readily account for multiphysics feedback. BlueCRAB allows for the coupling of different physics codes together to perform multiphysics-informed calculations. Therefore, the purpose of this fiscal year 2023 work is to investigate the feasibility and challenges of performing such calculations within BlueCRAB so as to generate the data that MELCOR relies on. To demonstrate the methodology, the proposed workflow was applied to a prototypical heat pipe-cooled microreactor model. To predict isotopic concentrations (taking into account the ac- cumulation of fission products during operation), the necessary microscopic cross sections were generated via OpenMC and tabulated with respect to temperature and burnup. Next, a recently developed capability in Griffin (the reactor physics application in BlueCRAB) was used to convert the OpenMC output format into the ISOXML format used by Griffin. A multiphysics microscopic depletion calculation that involved performing a coupled full-core, heterogeneous neutron trans- port and thermal calculation at each depletion step was conducted to deplete the core to end of life (EOL) conditions so as to provide both isotopics and the initial condition for the transient calculation. Following a brief null-transient to verify that the initial condition had been properly restarted and was indeed in thermal equilibrium, a heat pipe failure transient was simulated. Thus, the entire workflow of using BlueCRAB to generate MELCOR inputs, from cross-section generation to producing isotopic inventory and power/temperature evolution profiles during transients, is demonstrated. This report also details the identified gaps in the workflow and how they were (for the most part) addressed. Future work should focus on directly including MEL- COR into the workflow by performing a MELCOR calculation using the BlueCRAB-generated input data. In addition, the heat pipe reactor design should be improved so as to reflect more prototypical burnup characteristics at EOL.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark studies among own and commercial beam tracking codes on fundamental conditions

In order to design accelerators or to analyze experimental data, commercially or noncommercially programs for tracking particles have been developed and used. However the reliabilities of those programs are not clear, especially if the beam quality is as high as that required for future applications. Therefore, for the purpose to study the reliabilities and to improve their accuracy, we planed to benchmark those programs. As a first step, the calculations were carried out in the both condition of free space and homogeneously accelerating-field by using three own codes and three commercial codes (MAGIC, PARMELA, and GPT)

43 PARTICLE ACCELERATORS↗

SU-E-T-380: Evaluation of BEBIG HDR 60Co System for AccuBoost Therapy

Purpose: In this project, the possibility of utilizing the BEBIG 60Co HDR system for AccuBoostTM treatment has been evaluated. Methods: Dose distributions in various breast sizes have been calculated for both Co-60 and Ir-192 sources using the MCNP5 code. These calculations were performed in breast tissues with thicknesses of 4cm, 6cm, and 8cm. The initial calculations were performed with the same applicator dimensions as the existing applicators used with the HDR Ir-192 system. The activity of the Co-60 source was selected such that the dose at the breast center was the same as the values from 192Ir. Then, the applicator thicknesses were increased to twice of those used with HDR Ir-192 system, for reducing skin and chest doses by Co-60 system. Dose to breast skin and chest wall were compared for both applicators types, with and without inclusion of a focusing cone at the applicator center. Results: The results showed that loading HDR Co-60 source inside the thin applicators impose higher doses to breast skin and chest wall compared to the 192Ir source. The area of the chest wall covered by 10Gy when treated by Co-60 with the thin and thick applicators, or treated by Ir-192 with thin applicator are 79cm2, 39cm2, and 3.8cm2, respectively. These values are reduced to 34cm2, 0cm2, and 0cm2 by using the focusing cone. It is worth noting that the breast skin areas covered by the 60Gy isodose line are 9.9cm2 and 7.8cm2 for Co-60 with the thin and thick applicators, respectively, while it is 20cm2 for Ir-192 when no focusing cone is present. These values are 0cm2, 0cm2, and 11cm2 in the presence of the focusing cone. Conclusion: The results indicate that using Co-60 with the thicker applicators is beneficial because of the higher half-life of Co-60, and the reduced maximum skin dose when compared with Ir-192.

60 APPLIED LIFE SCIENCES↗

Current State of Neutron Source Term Calculations

SOURCES-4C has some significant deficiencies that are mostly due to problems with the default data libraries that it uses. Some research groups have modified these libraries to fix most of the problems, but not all of them. Adding modern data libraries to SOURCES-4C is one of the most promising approaches to resolving these issues. Other promising options include using either NEDIS or a GEANT4 tool. Both of these codes approximately match the accuracy of the modified SOURCES-4C code. The NEDIS code is Russian. The GEANT4 tool might be computationally slow and it might also no longer be actively maintained. There are a handful of other (α,n) codes, but they are not accurate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fringe biasing: A variance reduction technique for optically thick meshes

Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

97 MATHEMATICS AND COMPUTING↗

MetaboDirect: an analytical pipeline for the processing of FT-ICR MS-based metabolomic data

Background: Microbiomes are now recognized as the main drivers of ecosystem function ranging from the oceans and soils to humans and bioreactors. However, a grand challenge in microbiome science is to characterize and quantify the chemical currencies of organic matter (i.e., metabolites) that microbes respond to and alter. Critical to this has been the development of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), which has drastically increased molecular characterization of complex organic matter samples, but challenges users with hundreds of millions of data points where readily available, user-friendly, and customizable software tools are lacking. Results: Here, we build on years of analytical experience with diverse sample types to develop MetaboDirect, an open-source, command-line-based pipeline for the analysis (e.g., chemodiversity analysis, multivariate statistics), visualization (e.g., Van Krevelen diagrams, elemental and molecular class composition plots), and presentation of direct injection high-resolution FT-ICR MS data sets after molecular formula assignment has been performed. When compared to other available FT-ICR MS software, MetaboDirect is superior in that it requires a single line of code to launch a fully automated framework for the generation and visualization of a wide range of plots, with minimal coding experience required. Among the tools evaluated, MetaboDirect is also uniquely able to automatically generate biochemical transformation networks (ab initio) based on mass differences (mass difference network-based approach) that provide an experimental assessment of metabolite connections within a given sample or a complex metabolic system, thereby providing important information about the nature of the samples and the set of microbial reactions or pathways that gave rise to them. Finally, for more experienced users, MetaboDirect allows users to customize plots, outputs, and analyses. Conclusion: Application of MetaboDirect to FT-ICR MS-based metabolomic data sets from a marine phage-bacterial infection experiment and a Sphagnum leachate microbiome incubation experiment showcase the exploration capabilities of the pipeline that will enable the research community to evaluate and interpret their data in greater depth and in less time. It will further advance our knowledge of how microbial communities influence and are influenced by the chemical makeup of the surrounding system. The source code and User’s guide of MetaboDirect are freely available through (https://github.com/Coayala/MetaboDirect) and (https://metabodirect.readthedocs.io/en/latest/), respectively.

54 ENVIRONMENTAL SCIENCES↗

Gamma-ray imaging with a rotating hexagonal uniformly redundant array

Laboratory experiments have been performed to demonstrate the capabilities of a gamma-ray imaging system employing a NaI Anger camera and a rotating coded aperture mask. The mask incorporates in its design a new type of hexagonal uniformly redundant array (HURA) which is essentially antisymmetric under 60 deg rotation. The image formation techniques are described and results are presented that demonstrate the imaging capability of the system for individual and multiple point sources of gamma-ray emission. The results are compared to analytical predictions for the imaging and point source localization capabilities of coded aperture systems using continuous detectors.

Cook, W. R.↗

Exploiting fission chain reaction dynamics to image fissile materials

Radiation imaging is one potential method to verify nuclear weapons dismantlement. In this work, we present a method to discriminate between non-multiplying and multiplying neutron sources using a neutron coded aperture imaging system. This method applies time-correlated pulse-height (TCPH) analysis to identify neutrons in fission chain reactions and recreate images using only these events. This analysis was applied to measurements of weapons-grade plutonium (WGPu) metal and 252 Cf performed at the Nevada National Security Site (NNSS) Device Assembly Facility in July 2015. The results demonstrate it is possible to eliminate the non-fissile 252 Cf source from the image while preserving the fissile WGPu source. TCPH analysis was also applied to additional scenes in which the WGPu and 252 Cf sources were measured individually. The results of these separate measurements further demonstrate the ability to remove the non-fissile 252 Cf source and retain the fissile WGPu source. Simulations performed using MCNPX-PoliMi indicate that in a one hour measurement, hollow WGPu spheres are retained at a 1σ level for neutron multiplications M ≃ 2:7 and above. This work has potential application to dismantlement verification where it may be valuable to verify that all neutron sources in an image are multiplying.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digitally Enhanced Heterodyne Interferometry

Spurious interference limits the performance of many interferometric measurements. Digitally enhanced interferometry (DEI) improves measurement sensitivity by augmenting conventional heterodyne interferometry with pseudo-random noise (PRN) code phase modulation. DEI effectively changes the measurement problem from one of hardware (optics, electronics), which may deteriorate over time, to one of software (modulation, digital signal processing), which does not. DEI isolates interferometric signals based on their delay. Interferometric signals are effectively time-tagged by phase-modulating the laser source with a PRN code. DEI improves measurement sensitivity by exploiting the autocorrelation properties of the PRN to isolate only the signal of interest and reject spurious interference. The properties of the PRN code determine the degree of isolation.

Shaddock, Daniel↗

A progressive data compression scheme based upon adaptive transform coding: Mixture block coding of natural images

A method for efficiently coding natural images using a vector-quantized variable-blocksized transform source coder is presented. The method, mixture block coding (MBC), incorporates variable-rate coding by using a mixture of discrete cosine transform (DCT) source coders. Which coders are selected to code any given image region is made through a threshold driven distortion criterion. In this paper, MBC is used in two different applications. The base method is concerned with single-pass low-rate image data compression. The second is a natural extension of the base method which allows for low-rate progressive transmission (PT). Since the base method adapts easily to progressive coding, it offers the aesthetic advantage of progressive coding without incorporating extensive channel overhead. Image compression rates of approximately 0.5 bit/pel are demonstrated for both monochrome and color images.

Rost, Martin C.↗

RVA. 3-D Visualization and Analysis Software to Support Management of Oil and Gas Resources

A free software application, RVA, has been developed as a plugin to the US DOE-funded ParaView visualization package, to provide support in the visualization and analysis of complex reservoirs being managed using multi-fluid EOR techniques. RVA, for Reservoir Visualization and Analysis, was developed as an open-source plugin to the 64 bit Windows version of ParaView 3.14. RVA was developed at the University of Illinois at Urbana-Champaign, with contributions from the Illinois State Geological Survey, Department of Computer Science and National Center for Supercomputing Applications. RVA was designed to utilize and enhance the state-of-the-art visualization capabilities within ParaView, readily allowing joint visualization of geologic framework and reservoir fluid simulation model results. Particular emphasis was placed on enabling visualization and analysis of simulation results highlighting multiple fluid phases, multiple properties for each fluid phase (including flow lines), multiple geologic models and multiple time steps. Additional advanced functionality was provided through the development of custom code to implement data mining capabilities. The built-in functionality of ParaView provides the capacity to process and visualize data sets ranging from small models on local desktop systems to extremely large models created and stored on remote supercomputers. The RVA plugin that we developed and the associated User Manual provide improved functionality through new software tools, and instruction in the use of ParaView-RVA, targeted to petroleum engineers and geologists in industry and research. The RVA web site (http://rva.cs.illinois.edu) provides an overview of functions, and the development web site (https://github.com/shaffer1/RVA) provides ready access to the source code, compiled binaries, user manual, and a suite of demonstration data sets. Key functionality has been included to support a range of reservoirs visualization and analysis needs, including: sophisticated connectivity analysis, cross sections through simulation results between selected wells, simplified volumetric calculations, global vertical exaggeration adjustments, ingestion of UTChem simulation results, ingestion of Isatis geostatistical framework models, interrogation of joint geologic and reservoir modeling results, joint visualization and analysis of well history files, location-targeted visualization, advanced correlation analysis, visualization of flow paths, and creation of static images and animations highlighting targeted reservoir features.

97 MATHEMATICS AND COMPUTING↗

VHClass

The code is used to predict the taxonomic source of an antibody heavy chain sequence. The code assigns a binary label to the input set of sequences - camelid or human. This prediction is generated using a random-forest based classification algorithm which is the backbone of the code. A complementary code splits the antibody sequence into antibody features - framework regions and CDR regions.

Davis, Anastasiia↗