Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE Healthcare), followed by a CT scan for attenuation correction (AC). For each experiment, separate images were created including reconstruction with no corrections (NC), with AC, with attenuation and dual-energy window (DEW) scatter correction (ACSC), with attenuation and partial volume correction (PVC) applied (ACPVC), and with attenuation, scatter, and PVC applied (ACSCPVC). The DEW SC method used was modified to account for the presence of the low-energy tail. Results: T-tests showed that the mean error in absolute activity measurement was reduced significantly for AC and ACSC compared to NC for both (hot and cold) datasets (p < 0.001) and that ACSC, ACPVC, and ACSCPVC show significant reductions in mean differences compared to AC (p ≤ 0.001) without increasing the uncertainty (p > 0.4). The effect of SC and PVC was significant in reducing errors over AC in both datasets (p < 0.001 and p < 0.01, respectively), resulting in a mean error of 5% ± 4%. Conclusions: Quantitative measurements of cardiac {sup 99m}Tc activity are achievable using attenuation and scatter corrections, with the authors’ dedicated cardiac SPECT camera. Partial volume corrections offer improvements in measurement accuracy in AC images and ACSC images with elevated background activity; however, these improvements are not significant in ACSC images with low background activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the magnitude of MBF errors resulting from motion in the superior/inferior and anterior/posterior directions was similar (up to 250%). Body motion effects were more detrimental for higher resolution PET imaging (2 vs 10 mm full-width at half-maximum), and for motion occurring during the mid-to-late time-frames. Motion correction of the reconstructed dynamic image series resulted in significant reduction in MBF errors, but did not account for the residual PET–CTAC misalignment artifacts. MBF bias was reduced further using global partial-volume correction, and using dynamic alignment of the PET projection data to the CT scan for accurate attenuation correction during image reconstruction. Conclusions: Patient body motion can produce MBF estimation errors up to 500%. To reduce these errors, new motion correction algorithms must be effective in identifying motion in the left/right direction, and in the mid-to-late time-frames, since these conditions produce the largest errors in MBF, particularly for high resolution PET imaging. Ideally, motion correction should be done before or during image reconstruction to eliminate PET-CTAC misalignment artifacts.

60 APPLIED LIFE SCIENCES↗

Technical Note: Dosimetric effects of couch position variability on treatment plan quality with an MRI-guided Co-60 radiation therapy machine

Purpose: Magnetic resonance imaging (MRI) guidance in radiation therapy brings real-time imaging and adaptive planning into the treatment vault where it can account for interfraction and intrafraction movement of soft tissue. The only commercially available MRI-guided radiation therapy device is a three-head {sup 60}Co and MRI system with an integrated treatment planning system (TPS). Couch attenuation of the beam of up to 20% is well modeled in the TPS. Variations in the patient’s day-to-day position introduce discrepancies in the actual couch attenuation as modeled in the treatment plan. For this reason, the authors’ institution avoids plans with beams that pass through or near the couch edges. This study investigates the effects of differential beam attenuation by the couch due to couch shifts in order to determine whether couch edge avoidance restrictions can be lifted. Couch shifts were simulated using a Monte Carlo treatment planning system and ion chamber measurements performed for validation. Methods: A total of 27 plans from 23 patients were investigated. Couch shifts of 1 and 2 cm were introduced in combinations of lateral and vertical directions to simulate patient position variations giving 16 shifted plans per reference plan. The 1 and 2 cm shifts were based on shifts recorded in 320 treatment fractions. Results: Following TG176 recommendations for measurement methods, couch attenuation measurements agreed with TPS modeled attenuation to within 2.1%. Planning target volume D95 changed less than 1% for 1 and 2 cm couch shifts in only the x-direction and less than 3% for all directions. Conclusions: Dosimetry of all plans tested was robust to couch shifts up to ±2 cm. In general, couch shifts resulted in clinically insignificant dosimetric deviations. It is conceivable that in certain cases with large systematic couch shifts and plans that are particularly sensitive to shifts, dosimetric changes might rise to a clinically significant level.

60 APPLIED LIFE SCIENCES↗

SU-F-T-330: Characterization of the Clinically Released ScandiDos Discover Diode Array for In-Vivo Dose Monitoring

Purpose: The ScandiDos Discover has obtained FDA clearance and is now clinically released. We studied the essential attenuation and beam hardening components as well as tested the diode array’s ability to detect changes in absolute dose and MLC leaf positions. Methods: The ScandiDos Discover was mounted on the heads of an Elekta VersaHD and a Varian 23EX. Beam attenuation measurements were made at 10 cm depth for 6 MV and 18 MV beam energies. The PDD(10) was measured as a metric for the effect on beam quality. Next, a plan consisting of two orthogonal 10 × 10 cm2 fields was used to adjust the dose per fraction by scaling monitor units to test the absolute dose detection sensitivity of the Discover. A second plan (conformal arc) was then delivered several times independently on the Elekta VersaHD. Artificially introduced MLC position errors in the four central leaves were then added. The errors were incrementally increased from 1 mm to 4 mm and back across seven control points. Results: The absolute dose measured at 10 cm depth decreased by 1.2% and 0.7% for 6 MV and 18 MV beam with the Discover, respectively. Attenuation depended slightly on the field size but only changed the attenuation by 0.1% across 5 × 5 cm{sup 2} and 20 − 20 cm{sup 2} fields. The change in PDD(10) for a 10 − 10 cm{sup 2} field was +0.1% and +0.6% for 6 MV and 18 MV, respectively. Changes in monitor units from −5.0% to 5.0% were faithfully detected. Detected leaf errors were within 1.0 mm of intended errors. Conclusion: A novel in-vivo dosimeter monitoring the radiation beam during treatment was examined through its attenuation and beam hardening characteristics. The device tracked with changes in absolute dose as well as introduced leaf position deviations.

60 APPLIED LIFE SCIENCES↗

X-ray Spectral Analysis for Void Fraction Measurement

X-ray attenuation technique has been widely used in two-phase flow measurement. In general, an x-ray system measures the overall attenuation of the two-phase mixture existing between an x-ray source and a detector. One can obtain the void fraction from the intensity of the attenuated x-ray beam and known attenuation coefficients of each phase. Fig. 1 shows a schematic of the line detector system developed at Virginia Tech, and the reconstructed image of a sample slug bubble. The system is capable of obtaining high-resolution (100 {mu}m or less) x-ray images of two-phase flow at a frame rate exceeding 1000 Hz. Note that the intensity of the image can be converted into the line-averaged void fraction data measured by each detector pixel. Typical x-ray systems do not resolve the energy spectrum. Instead, they only measure the total energy deposited in the detector during the exposure period. However, the x-ray source generated from x-ray tubes present polychromatic characteristics. The attenuation coefficient and detector efficiency strongly depend on the energy of x-ray photons. In relation to this, this paper presents the spectral characteristics of a typical x-ray system used for void fraction measurement in two-phase flows. The photon-energy-dependent efficiency of the detector is determined by a calibration test. (authors)

42 ENGINEERING↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retrofiting survivability of military vehicles

In Iraq the terrain was such that vehicles could be distributed horizontally, which reduced the effectiveness of mines. In the mountainous terrain of Pakistan and Afghanistan vehicles are forced to use the few, passable roads, which are dirt and easily seeded with plentiful, cheap, intelligent mines. It is desirable to reduce the losses to such mines, preferably by retrofit means that do not greatly increase weight or cost or reduce maneuverability. V-bottom vehicles - A known approach to reducing vulnerability is the Buffalo, a large vehicle developed by South Africa to address mine warfare. It has large tires, high axles, and a reinforced, v-shaped bottom that deflects the blast from explosions below. It is developed and tested in combat, but is expensive and has reduced off-road mobility. The domestic MRAP has similar cost and mobility issue. The addition of v-shaped blast deflectors to vehicles such as Humvees could act much as the deflector on a Buffalo, but a Humvee is closer to the ground, so the explosive's expansion would be reduced. The deflector would also reduce a Humvee's clearance for rough terrain, and a deflector of adequate thickness to address the blast by itself could further increase cost and reduce mobility. Reactive armor is developed and has proven effective against shaped and explosive charges from side or top attack. It detects their approach, detonates, and defeats them by interfering with jet formation. If the threat was a shaped charge from below, they would be a logical choice. But the bulk of the damage to Humvees appears to be from the blast from high explosive mines for which the colliding shock from reactive armor could increase that from the explosive. Porous materials such as sand can strongly attenuate the kinetic energy and pressure of a strong shock. Figure 1 shows the kinetic energy (KE), momentum (Mu), velocity (u), and mass (M) of a spherically expanding shock as functions of radius for a material with a porosity of 0.5. Over the range from 0.5 to 4.5 cm the shock KE is attenuated by a factor of {approx}70, while its momentum is changed little. The shock and particle velocity falls by a factor of 200 while the mass increases by a factor of 730. In the limit of very porous media u {approx} 1/M, so KE {approx} 1/M, which falls by a factor of {approx}600, while momentum Mu does not change at all. Figure 2 shows the KE, Mu, u, and M for a material with a porosity of 1.05, for which the KE changes little. In the limit of media of very low porosity, u {approx} 1/{radical}M, so KE is constant while Mu {approx} {radical}M, which increases by a factor of 15. Thus, if the goal is to reduce the peak pressure from strong explosions below, very porous materials, which strongly reduce pressure but do not increase momentum, are preferred to non-porous materials, which amplify momentum but do not decrease pressure. These predictions are in qualitative accord with the results of experiments at Los Alamos in which projectiles from high velocity, large caliber cannons were stopped by one to two sandbags. The studies were performed primarily to determine the effectiveness of sand in stopping fragments of various sizes, but could be extended to study sand's effectiveness in attenuating blast pressure. It would also be useful to test the above predictions on the effectiveness of media with higher porosity. Water barriers have been discussed but not deployed in previous retrofit survivability studies for overseas embassies. They would detect the flash from the mine detonation below, trigger a thin layer of explosive above a layer of water, and drive water droplets into the approaching blast wave. The blast loses energy in evaporating the droplets and loses momentum in slowing them. Under favorable conditions that could attenuate the pressure in the blast enough to prevent the penetration or disruption of the vehicle. However, such barriers would depend on prompt and reliable detonation detection and water droplet dispersal, which have not been tested. There is a large literature on the theoretical effectiveness of such barriers, but little careful experimentation. An exception is the set of experiments performed by the Australian government DoD. They measured pressures at 1, 2, and 3 m distances from 500 g PBX charges, using commercial fire sprinklers to produce the spray of droplets between the charge and the pressure gauges. The experiments showed some attenuation, but were performed only at a few atmosphere over pressure, so they did not test the effect of the principal posited vaporization mechanism. Preliminary experiments at Los Alamos showed some reduction, but used sheets of water, so they could only test the effect of momentum coupling.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Proton scaling

This note presents analytic estimates of the performance of proton beams in remote surveillance for nuclear materials. The analysis partitions the analysis into the eight steps used by a companion note: (1) Air scattering, (2) Neutron production in the ship and cargo, (3) Target detection probability, (4) Signal produced by target, (5) Attenuation of signal by ship and cargo, (6) Attenuation of signal by air, (7) Geometric dilution, and (8) Detector Efficiency. The above analyses indicate that the dominant air scattering and loss mechanisms for particle remote sensing are calculable with reliable and accepted tools. They make it clear that the conversion of proton beams into neutron sources rapidly goes to completion in all but thinnest targets, which means that proton interrogation is for all purposes executed by neutrons. Diffusion models and limiting approximations to them are simple and credible - apart from uncertainty over the cross sections to be used in them - and uncertainty over the structure of the vessels investigated. Multiplication is essentially unknown, in part because it depends on the details of the target and its shielding, which are unlikely to be known in advance. Attenuation of neutron fluxes on the way out are more complicated due to geometry, the spectrum of fission neutrons, and the details of their slowing down during egress. The attenuation by air is large but less uncertain. Detectors and technology are better known. The overall convolution of these effects lead to large but arguably tolerable levels of attenuation of input beams and output signals. That is particularly the case for small, mobile sensors, which can more than compensate for size with proximity to operate reliably while remaining below flux limits. Overall, the estimates used here appear to be of adequate accuracy for decisions. That assessment is strengthened by their agreement with companion calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of salvianolic acids on oxidative stress and hepatic fibrosis in rats

Enhanced oxidative stress is associated with hepatic fibrosis. Salvianolic acids A (Sal A) and B (Sal B) have been reported to be strong polyphenolic antioxidants and free radical scavengers. The present study is to investigate if Sal A and B could attenuate oxidative stress and liver fibrosis in rats. A cell line of rat hepatic stellate cells (HSCs) was stimulated with platelet-derived growth factor (PDGF, 10 ng/ml). The inhibitory effects of Sal A and B on intracellular hydrogen peroxide levels were measured with dichlorofluorescein diacetate (DCF-DA) dye assay. alpha-Smooth muscle actin (alpha-SMA), nicotinamide adenine dinucleotide phosphate (NADPH) oxidase subunits were measured by Western blotting. Liver fibrosis was induced by intraperitoneal injections of thioacetamide (TAA, 200 mg/kg) twice per week for 6 weeks. Sal A (10 mg/kg), Sal B (50 mg/kg) or S-adenosylmethionine (SAMe, 10 mg/kg), was given by gavage twice per day consecutively for 4 weeks starting 2 weeks after TAA injection. In vitro, PDGF increased the accumulation of hydrogen peroxide in HSCs, which was attenuated by Sal A (10 muM) and Sal B (200 muM). Sal A and B attenuated the PDGF-stimulated expressions of alpha-SMA and NADPH oxidase subunits gp91{sup phox} and p47{sup phox} in membrane fractions. In vivo studies showed that the hepatic levels of collagen, malondialdehyde, TNF-alpha, IL-6, and IL-1beta, fibrosis scores and protein expressions of alpha-SMA, heme-oxygenase-1, iNOS, and gp91{sup phox}, and serum levels of ALT, AST, IL-6, and IL-1beta were increased in TAA-intoxicated rats, all of which were attenuated by 4-week treatment of Sal A or Sal B. Our results showed that Sal A and B attenuated PDGF-induced ROS formation in HSCs, possibly through inhibition of NADPH oxidase. Sal A and B treatments were also effective against hepatic fibrosis in TAA-intoxicated rats.

60 APPLIED LIFE SCIENCES↗

Effect of baicalin on toll-like receptor 4-mediated ischemia/reperfusion inflammatory responses in alcoholic fatty liver condition

Alcoholic fatty liver is susceptible to secondary stresses such as ischemia/reperfusion (I/R). Baicalin is an active component extracted from Scutellaria baicalensis, which is widely used in herbal preparations for treatment of hepatic diseases and inflammatory disorders. This study evaluated the potential beneficial effect of baicalin on I/R injury in alcoholic fatty liver. Rats were fed an alcohol liquid diet or a control isocaloric diet for 5 weeks, and then subjected to 60 min of hepatic ischemia and 5 h of reperfusion. Baicalin (200 mg/kg) was intraperitoneally administered 24 and 1 h before ischemia. After reperfusion, baicalin attenuated the increases in serum alanine aminotransferase activity, tumor necrosis factor-α (TNF-α), and interleukin-6 (IL-6) levels in alcoholic fatty liver. The increased levels of TNF-α and IL-6 mRNA expression and inducible nitric oxide synthase and cyclooxygenase-2 protein and mRNA expressions increased after reperfusion, which were higher in ethanol-fed animals, were attenuated by baicalin. In ethanol-fed animals, baicalin attenuated the increases in toll-like receptor 4 (TLR4) and myeloid differentiation factor 88 protein expressions and the nuclear translocation of NF-κB after reperfusion. In conclusion, our findings suggest that baicalin ameliorates I/R-induced hepatocellular damage by suppressing TLR4-mediated inflammatory responses in alcoholic fatty liver. -- Highlights: ► Baicalin attenuates hepatic I/R-induced inflammation in alcoholic fatty liver. ► Baicalin downregulates TLR4, MyD88 expression during I/R in alcoholic fatty liver. ► Baicalin attenuates NF-κB nuclear translocation during I/R in alcoholic fatty liver.

60 APPLIED LIFE SCIENCES↗

Protective effects of the compounds isolated from the seed of Psoralea corylifolia on oxidative stress-induced retinal damage

The mechanism underlying glaucoma remains controversial, but apoptosis caused by increased levels of reactive oxygen species (ROS) is thought to play a role in its pathogenesis. We investigated the effects of compounds isolated from Psoralea corylifolia on oxidative stress-induced cell death in vitro and in vivo. Transformed retinal ganglion cells (RGC-5) were treated with L-buthione-(S,R)-sulfoximine (BSO) and glutamate in the presence or with pre-treatment with compound 6, bakuchiol isolated from P. corylifolia. We observed reduced cell death in cells pre-treated with bakuchiol. Moreover, bakuchiol inhibited the oxidative stress-induced decrease of mitochondrial membrane potential (MMP, ΔΨm). Furthermore, while intracellular Ca{sup 2+} was high in RGC-5 cells after exposure to oxidative stress, bakuchiol reduced these levels. In an in vivo study, in which rat retinal damage was induced by intravitreal injection of N-methyl-D-aspartate (NMDA), bakuchiol markedly reduced translocation of AIF and release of cytochrome c, and inhibited up-regulation of cleaved caspase-3, cleaved caspase-9, and cleaved PARP. The survival rate of retinal ganglion cells (RGCs) 7 days after optic nerve crush (ONC) in mice was significantly decreased; however, bakuchiol attenuated the loss of RGCs. Moreover, bakuchiol attenuated ONC-induced up-regulation of apoptotic proteins, including cleaved PARP, cleaved caspase-3, and cleaved caspase-9. Bakuchiol also significantly inhibited translocation of mitochondrial AIF into the nuclear fraction and release of mitochondrial cytochrome c into the cytosol. These results demonstrate that bakuchiol isolated from P. corylifolia has protective effects against oxidative stress-induced retinal damage, and may be considered as an agent for treating or preventing retinal degeneration. - Highlights: • Psoralea corylifolia have neuroprotective effects in vitro and in vivo. • Bakuchiol attenuated the increase of apoptotic proteins induced by oxidative stress. • Bakuchiol restored the reduced mitochondrial membrane potential. • Bakuchiol attenuated the increase of intracellular Ca{sup 2+}. • Bakuchiol attenuated retinal degeneration in vivo.

60 APPLIED LIFE SCIENCES↗

Andrographolide inhibits adipogenesis of 3T3-L1 cells by suppressing C/EBPβ expression and activation

Andrographolide, a diterpenoid, is the most abundant terpenoid in Andrographis paniculata, a popular Chinese herbal medicine. Andrographolide displays diverse biological activities including hypoglycemia, hypolipidemia, anti-inflammation, and anti-tumorigenesis. Recent evidence indicates that andrographolide displays anti-obesity property by inhibiting lipogenic gene expression, however, the underlying mechanisms remain to be elucidated. In this study, the effects of andrographolide on transcription factor cascade and mitotic clonal expansion in 3T3-L1 preadipocyte differentiation into adipocyte were determined. Andrographolide dose-dependently (0–15 μM) inhibited CCAAT/enhancer-binding protein α (C/EBPα) and C/EBPβ mRNA and protein expression as well as peroxisome proliferator-activated receptor γ (PPARγ) protein level during the adipogenesis of 3T3-L1 cells. Concomitantly, fatty acid synthase and stearoyl-CoA desaturase expression and lipid accumulation were attenuated by andrographolide. Oil-red O staining further showed that the first 48 h after the initiation of differentiation was critical for andrographolide inhibition of adipocyte formation. Andrographolide inhibited the phosphorylation of PKA and the activation of cAMP response element-binding protein (CREB) in response to a differentiation cocktail, which led to attenuated C/EBPβ expression. In addition, ERK and GSK3β-dependent C/EBPβ phosphorylation was attenuated by andrographolide. Moreover, andrographolide suppressed cyclin A, cyclin E, and CDK2 expression and impaired the progression of mitotic clonal expansion (MCE) by arresting the cell cycle at the Go/G1 phase. Taken together, these results indicate that andrographolide has a potent anti-obesity action by inhibiting PKA-CREB-mediated C/EBPβ expression as well as C/EBPβ transcriptional activity, which halts MCE progression and attenuates C/EBPα and PPARγ expression. - Highlights: • Andrographolide is a diterpenoid phytochemical. • Andrographolide inhibits adipogenesis of 3 T3-L1 adipocytes. • Andrographolide suppresses differentiation cocktail-induced C/EBPβ expression. • Andrographolide attenuates ERK and GSK3β-dependent C/EBPβ activation. • Andrographolide arrests 3 T3-L1 adipocytes at G0/G1 phase.

60 APPLIED LIFE SCIENCES↗

Role of necroptosis in autophagy signaling during hepatic ischemia and reperfusion

Ischemia and reperfusion (I/R) is a complex phenomenon involving massive inflammation and cell death. Necroptosis refers to a newly described cell death as “programmed necrosis” that is controlled by receptor-interacting protein kinase (RIP) 1 and RIP3, which is involved in the pathogenesis of several inflammatory diseases. Autophagy is an essential cytoprotective system that is rapidly activated in response to various stimuli and involves crosstalk between different modes of cell death and inflammation. In this study, we investigated pattern changes in necroptosis and its role in autophagy signaling during hepatic I/R. Male C57BL/6 mice were subjected to 60 min of ischemia followed by 3 h reperfusion. Necrostatin-1 (Nec-1, a necroptosis inhibitor; 1.65 mg/kg) was administered intraperitoneally 5 min before reperfusion. Hepatic I/R significantly increased the level of RIP3, phosphorylated RIP1 and RIP3 protein expression, and RIP1/RIP3 necrosome formation, which were attenuated by Nec-1. I/R also significantly increased serum levels of alanine aminotransferase, tumor necrosis factor-α, and interleukin-6, which were attenuated by Nec-1. Meanwhile, hepatic I/R activated autophagy and mitophagy, as evidenced by increased LC3-II, PINK1, and Parkin, and decreased sequestosome 1/p62 protein expression. Nec-1 attenuated these changes and attenuated the increased levels of autophagy-related protein (ATG) 3, ATG7, Rab7, and cathepsin B protein expression during hepatic I/R. Moreover, hepatic I/R activated the extracellular signal-regulated kinase (ERK) pathway, and Nec-1 attenuated this increase. Taken together, our findings suggest that necroptosis contributes to hepatic damage during I/R, which induces autophagy via ERK activation. - Highlights: • Hepatic I/R induces RIP1/RIP3-dependent necroptosis. • Necroptosis contributes to hepatic I/R injury. • Necroptosis activates autophagic flux via ERK activation during hepatic I/R.

60 APPLIED LIFE SCIENCES↗

Akt-dependent NF-{kappa}B activation is required for bile acids to rescue colon cancer cells from stress-induced apoptosis

Conjugated secondary bile acids promote human colon cancer cell proliferation by activating EGF receptors (EGFR). We hypothesized that bile acid-induced EGFR activation also mediates cell survival by downstream Akt-regulated activation of NF-{kappa}B. Deoxycholyltaurine (DCT) treatment attenuated TNF-{alpha}-induced colon cancer cell apoptosis, and stimulated rapid and sustained NF-{kappa}B nuclear translocation and transcriptional activity (detected by NF-{kappa}B binding to an oligonucleotide consensus sequence and by activation of luciferase reporter gene constructs). Both DCT-induced NF-{kappa}B nuclear translocation and attenuation of TNF-{alpha}-stimulated apoptosis were dependent on EGFR activation. Inhibitors of nuclear translocation, proteosome activity, and I{kappa}B{alpha} kinase attenuated NF-{kappa}B transcriptional activity. Cell transfection with adenoviral vectors encoding a non-degradable I{kappa}B{alpha} 'super-repressor' blocked the actions of DCT on both NF-{kappa}B activation and TNF-{alpha}-induced apoptosis. Likewise, transfection with mutant akt and treatment with a chemical inhibitor of Akt attenuated effects of DCT on NF-{kappa}B transcriptional activity and TNF-{alpha}-induced apoptosis. Chemical inhibitors of Akt and NF-{kappa}B activation also attenuated DCT-induced rescue of H508 cells from ultraviolet radiation-induced apoptosis. Collectively, these observations indicate that, downstream of EGFR, bile acid-induced colon cancer cell survival is mediated by Akt-dependent NF-{kappa}B activation. These findings provide a mechanism whereby bile acids increase resistance of colon cancer to chemotherapy and radiation.

60 APPLIED LIFE SCIENCES↗

Radiation Shielding Options for the Affordable Fission Surface Power System

The Affordable Fission Surface Power System (AFSPS) is a proposed power source for an outpost capable of housing six humans for up to six weeks on the lunar surface and emphasizes the design principles of low risk and affordability over high performance. The radiation shield is the most massive component of the reactor system and its effect on launch mass greatly affects the affordability of the AFSPS. Potential shielding materials include lithium hydride, enriched boron-10 carbide, water, borated water, beryllium, boron-doped beryllium and zirconium hydride. Zirconium hydride is the most effective neutron attenuator and also significantly attenuates gamma radiation, but at a significant mass penalty. The other neutron attenuating materials all require the addition of a tungsten layer to provide significant gamma attenuation. Based on neutron radiation alone, lithium hydride is the lightest of the potential attenuators, followed by water and borated water. When gamma radiation is also considered, the lithium hydride/tungsten shield is shown to be the lightest composite shield with a combined mass of 3246 kg, followed by the borated water/tungsten shield (3479 kg). The boron carbide/tungsten shield has a total mass of 4129 kg, but represents significantly less development risk.

36 MATERIALS SCIENCE↗

Nuclear fusion of deuterons with light nuclei driven by Coulomb explosion of nanodroplets

Theoretical-computational studies of table-top laser-driven nuclear fusion of high energy (up to 15 MeV) deuterons with {sup 7}Li, {sup 6}Li, T, and D demonstrate the attainment of high fusion yields. The reaction design constitutes a source of Coulomb exploding deuterium nanodroplets driven by an ultraintense, near-infrared, femtosecond Gaussian laser pulse (peak intensity 2 Multiplication-Sign 10{sup 18}-5 Multiplication-Sign 10{sup 19} W cm{sup -2}) and a solid, hollow cylindrical target containing the second reagent. The exploding nanodroplets source is characterized by the deuteron kinetic energies, their number, and the laser energy absorbed by a nanodroplet. These were computed by scaled electron and ion dynamics simulations, which account for intra-nanodroplet laser intensity attenuation and relativistic effects. The fusion yields Y are determined by the number of the source deuterons and by the reaction probability. When laser intensity attenuation is weak within a single nanodroplet and throughout the nanodroplets assembly, Y exhibits a power law increase with increasing the nanodroplet size. Y is maximized for the nanodroplet size and laser intensity corresponding to the 'transition' between the weak and the strong intensity attenuation domains. The dependence of Y on the laser pulse energy W scales as W{sup 2} for weak assembly intensity attenuation, and as W for strong assembly intensity attenuation. This reaction design attains the highest table-top fusion efficiencies (up to 4 Multiplication-Sign 10{sup 9} J{sup -1} per laser pulse) obtained up to date.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An ALMA survey of sub-millimeter galaxies in the extended Chandra deep field south: Physical properties derived from ultraviolet-to-radio modeling

The ALESS survey has followed up on a sample of 122 sub-millimeter sources in the Extended Chandra Deep Field South at 870 μm with the Atacama Large Millimeter Array (ALMA), allowing us to pinpoint the positions of sub-millimeter galaxies (SMGs) to ∼0.3 arcsec and to find their precise counterparts at different wavelengths. This enabled the first compilation of the multi-wavelength spectral energy distributions (SEDs) of a statistically reliable survey of SMGs. In this paper, we present a new calibration of the magphys SED modeling code that is optimized to fit these ultraviolet-to-radio SEDs of z>1 star-forming galaxies using an energy balance technique to connect the emission from stellar populations, dust attenuation, and dust emission in a physically consistent way. We derive statistically and physically robust estimates of the photometric redshifts and physical parameters (such as stellar masses, dust attenuation, star formation rates (SFRs), and dust masses) for the ALESS SMGs. We find that the ALESS SMGs have median stellar mass M{sub ∗}=8.9±0.1×10{sup 10} M{sub ⊙}, median SFR = 280±70 M{sub ⊙} yr{sup −1}, median overall V-band dust attenuation A{sub V}=1.9±0.2 mag, median dust mass M{sub dust}=(5.6±1.0)×10{sup 8} M{sub ⊙}, and median average dust temperature T{sub dust}≃40 K. We find that the average intrinsic SED of the ALESS SMGs resembles that of local ultra-luminous infrared galaxies in the infrared range, but the stellar emission of our average SMG is brighter and bluer, indicating lower dust attenuation, possibly because they are more extended. We explore how the average SEDs vary with different parameters (redshift, sub-millimeter flux, dust attenuation, and total infrared luminosity), and we provide a new set of SMG templates that can be used to interpret other SMG observations. To put the ALESS SMGs into context, we compare their stellar masses and SFRs with those of less actively star-forming galaxies at the same redshifts. We find that at z≃2, about half of the SMGs lie above the star-forming main sequence (with SFRs three times larger than normal galaxies of the same stellar mass), while half are consistent with being at the high-mass end of the main sequence. At higher redshifts (z≃3.5), the SMGs tend to have higher SFRs and stellar masses, but the fraction of SMGs that lie significantly above the main sequence decreases to less than a third.

79 ASTRONOMY AND ASTROPHYSICS↗