DISCRIMINATION CALIBRATION ANALYSIS METHODS FOR REGIONAL STATIONS

For event discrimination, operational implementation of a regional seismic station requires three sequential calibration analyses. 1) Magnitude, distance and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. Calibration of MDAC can be accomplished with empirical Bayes estimation, which naturally provides metrics to determine when adequate calibration data have been acquired, and provides statistical assurance that the errors associated with MDAC calibration are negligible in future operational discrimination analysis. 2) MDAC corrected amplitudes can then be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We have developed a mathematical model to capture these near source effects as random (unknown) giving an error partition of three sources: model inadequacy, station noise and amplitude correlation. This mathematical model is the basis for a general multi-station regional discriminant. Calibration analysis for the standard error of the discriminant includes the calculation of the variances of model inadequacy and station noise, and amplitude correlation. 3) Likelihood-based seismic event identification analysis with MDAC discriminants requires estimated source population means and covariance matrices for the discriminants from each of the possible source types (e.g., deep earthquake, shallow earthquake, and explosion). Anderson et al. (2007) note that source population covariance matrices and the pooled covariance matrix are best estimated element-wise to fully utilize available calibration events. We propose an algorithm that may be used to mildly adjust an element-wise covariance matrix to ensure positive definiteness and non-singular behavior. The algorithm uses the Frobenius norm as the calibration metric because it minimally adjusts the variance terms of an element-wise covariance relative to the off-diagonal covariance terms to achieve a stable, positive semi-definite covariance matrix.

Anderson, Dale N.↗

Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

Chipera, S. J.↗

SU-E-P-44: The Characteristics and Clinical Application of the ArcCHECK for VMAT Verification

Purpose: To evaluate the characteristics and clinical suitability of the ArcCHECK QA system for VMAT verification. Methods: The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of TPS. Gamma index (3mm distance to agreement and 3% percentage difference ) was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans. Results: The ArcCHECK diodes performed well for all tests except directional dependence, which varies from a minimum of −3.9% (seen only when the beam is incident on the diode at 180°) to a maximum of 7.7% (approximately at 255°). Average gamma analysis passing rates with 3mm/3% for 113 NPC,48 cervical cancer and 50 rectal cancer VMAT plans are 93.5%,95.7% and 97.5%, statistical significance has been found between either two of the groups(t=−12.69∼−4.88,all P<0.01). Conclusion: With proposed calibration method,the ArcCHECK QA system is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.

60 APPLIED LIFE SCIENCES↗

Repeatability and reproducibility of intracellular molar concentration assessed by synchrotron-based x-ray fluorescence microscopy

Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the major obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Analysis of the theoretical bias in dark matter direct detection

Fitting the model ''A'' to dark matter direct detection data, when the model that underlies the data is ''B'', introduces a theoretical bias in the fit. We perform a quantitative study of the theoretical bias in dark matter direct detection, with a focus on assumptions regarding the dark matter interactions, and velocity distribution. We address this problem within the effective theory of isoscalar dark matter-nucleon interactions mediated by a heavy spin-1 or spin-0 particle. We analyze 24 benchmark points in the parameter space of the theory, using frequentist and Bayesian statistical methods. First, we simulate the data of future direct detection experiments assuming a momentum/velocity dependent dark matter-nucleon interaction, and an anisotropic dark matter velocity distribution. Then, we fit a constant scattering cross section, and an isotropic Maxwell-Boltzmann velocity distribution to the simulated data, thereby introducing a bias in the analysis. The best fit values of the dark matter particle mass differ from their benchmark values up to 2 standard deviations. The best fit values of the dark matter-nucleon coupling constant differ from their benchmark values up to several standard deviations. We conclude that common assumptions in dark matter direct detection are a source of potentially significant bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Generalized Canonical Polyadic Tensor Decomposition

Tensor decomposition is a fundamental unsupervised machine learning method in data science, with applications including network analysis and sensor data processing. This work develops a generalized canonical polyadic (GCP) low-rank tensor decomposition that allows other loss functions besides squared error. For instance, we can use logistic loss or Kullback--Leibler divergence, enabling tensor decomposition for binary or count data. We present a variety of statistically motivated loss functions for various scenarios. We provide a generalized framework for computing gradients and handling missing data that enables the use of standard optimization methods for fitting the model. Furthermore, we demonstrate the flexibility of the GCP decomposition on several real-world examples including interactions in a social network, neural activity in a mouse, and monthly rainfall measurements in India.

97 MATHEMATICS AND COMPUTING↗

Statistical analysis of failure data on controllers and SSME turbine blade failures

The expressions for the maximum likelihood functions are given when the failure data are censored at a given point or at multiple points, or when the data come in groups. Different models applicable to failure data are presented with their characteristics. A graphical method of distinguishing different models by using cumulative hazard fucnction is discussed. For the failure data on controllers the model is determined by cumulative hazard function and chi-square goodness of fit. Using the Weibull Model the maximum likelihood estimators of the shape parameter and the failure rate parameter are obtained. The confidence intervals, meantime between failures, and B1 are determined. Similarly, for the data on Space Shuttle Main Engine (SSME) blade failures the maximum likelihood estimators are obtained for the Weibull parameters. The variances, confidence intervals, meantime between failures, and reliability are determined. The analysis is performed under assumption of grouped data as well as randomly placed data.

Patil, S. A.↗

A Hybrid Energy System Workflow for Energy Portfolio Optimization

This manuscript develops a workflow, driven by data analytics algorithms, to support the optimization of the economic performance of an Integrated Energy System. The goal is to determine the optimum mix of capacities from a set of different energy producers (e.g., nuclear, gas, wind and solar). A stochastic-based optimizer is employed, based on Gaussian Process Modeling, which requires numerous samples for its training. Each sample represents a time series describing the demand, load, or other operational and economic profiles for various types of energy producers. These samples are synthetically generated using a reduced order modeling algorithm that reads a limited set of historical data, such as demand and load data from past years. Numerous data analysis methods are employed to construct the reduced order models, including, for example, the Auto Regressive Moving Average, Fourier series decomposition, and the peak detection algorithm. All these algorithms are designed to detrend the data and extract features that can be employed to generate synthetic time histories that preserve the statistical properties of the original limited historical data. The optimization cost function is based on an economic model that assesses the effective cost of energy based on two figures of merit: the specific cash flow stream for each energy producer and the total Net Present Value. An initial guess for the optimal capacities is obtained using the screening curve method. The results of the Gaussian Process model-based optimization are assessed using an exhaustive Monte Carlo search, with the results indicating reasonable optimization results. The workflow has been implemented inside the Idaho National Laboratory’s Risk Analysis and Virtual Environment (RAVEN) framework. The main contribution of this study addresses several challenges in the current optimization methods of the energy portfolios in IES: First, the feasibility of generating the synthetic time series of the periodic peak data; Second, the computational burden of the conventional stochastic optimization of the energy portfolio, associated with the need for repeated executions of system models; Third, the inadequacies of previous studies in terms of the comparisons of the impact of the economic parameters. The proposed workflow can provide a scientifically defendable strategy to support decision-making in the electricity market and to help energy distributors develop a better understanding of the performance of integrated energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design Oriented Structural Modeling for Airplane Conceptual Design Optimization

The main goal for research conducted with the support of this grant was to develop design oriented structural optimization methods for the conceptual design of airplanes. Traditionally in conceptual design airframe weight is estimated based on statistical equations developed over years of fitting airplane weight data in data bases of similar existing air- planes. Utilization of such regression equations for the design of new airplanes can be justified only if the new air-planes use structural technology similar to the technology on the airplanes in those weight data bases. If any new structural technology is to be pursued or any new unconventional configurations designed the statistical weight equations cannot be used. In such cases any structural weight estimation must be based on rigorous "physics based" structural analysis and optimization of the airframes under consideration. Work under this grant progressed to explore airframe design-oriented structural optimization techniques along two lines of research: methods based on "fast" design oriented finite element technology and methods based on equivalent plate / equivalent shell models of airframes, in which the vehicle is modelled as an assembly of plate and shell components, each simulating a lifting surface or nacelle / fuselage pieces. Since response to changes in geometry are essential in conceptual design of airplanes, as well as the capability to optimize the shape itself, research supported by this grant sought to develop efficient techniques for parametrization of airplane shape and sensitivity analysis with respect to shape design variables. Towards the end of the grant period a prototype automated structural analysis code designed to work with the NASA Aircraft Synthesis conceptual design code ACS= was delivered to NASA Ames.

Livne, Eli↗

Qualitative and Quantitative Evaluation for Representative Human Reliability Analysis Methods

The Korea Institute of Nuclear Safety (KINS) is the regulatory expert organization established by the Korean government to strengthen the nation’s technical capabilities relating to nuclear safety regulation. KINS oversees the technical aspects of nuclear safety regulation, including safety reviews, inspections, education, and safety research—all conducted based on technical knowledge and accumulated regulatory experience. In 2023, KINS requested that Idaho National Laboratory (INL) validates representative human reliability analysis (HRA) methods used throughout the world, thus affording KINS with a basis for determining an HRA method adequate for its domestic regulatory purposes. The present paper mainly examines INL’s efforts in this regard. The resulting INL study covered four representative HRA methods widely used by nuclear utilities and regulatory institutes. These methods were qualitatively evaluated by applying specific evaluation criteria and determining how well each method reflected critical HRA issues. For this assessment, INL benchmarked the Halden International HRA Empirical Study. Using the Halden empirical data, along with information on human failure events (HFEs), the present study employed the selected HRA methods to estimate human error probabilities (HEPs) for the HFEs. It also performed statistical analyses to compare the HEPs predicted via the HRA methods against those from the Halden empirical data.

99 - GENERAL AND MISCELLANEOUS↗

A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long term process performance indices (P{sub p}, P{sub pk}, and P{sub pm}) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-scale visual analysis of time-varying electrocorticography data via clustering of brain regions

There exists a need for effective and easy-to-use software tools supporting the analysis of complex Electrocorticography (ECoG) data. Understanding how epileptic seizures develop or identifying diagnostic indicators for neurological diseases require the in-depth analysis of neural activity data from ECoG. Such data is multi-scale and is of high spatio-temporal resolution. Comprehensive analysis of this data should be supported by interactive visual analysis methods that allow a scientist to understand functional patterns at varying levels of granularity and comprehend its time-varying behavior. We introduce a novel multi-scale visual analysis system, ECoG ClusterFlow, for the detailed exploration of ECoG data. Our system detects and visualizes dynamic high-level structures, such as communities, derived from the time-varying connectivity network. The system supports two major views: 1) an overview summarizing the evolution of clusters over time and 2) an electrode view using hierarchical glyph-based design to visualize the propagation of clusters in their spatial, anatomical context. We present case studies that were performed in collaboration with neuroscientists and neurosurgeons using simulated and recorded epileptic seizure data to demonstrate our system's effectiveness. ECoG ClusterFlow supports the comparison of spatio-temporal patterns for specific time intervals and allows a user to utilize various clustering algorithms. Neuroscientists can identify the site of seizure genesis and its spatial progression during various the stages of a seizure. Our system serves as a fast and powerful means for the generation of preliminary hypotheses that can be used as a basis for subsequent application of rigorous statistical methods, with the ultimate goal being the clinical treatment of epileptogenic zones.

60 APPLIED LIFE SCIENCES↗

Some new mathematical methods for variational objective analysis

Numerous results were obtained relevant to remote sensing, variational objective analysis, and data assimilation. A list of publications relevant in whole or in part is attached. The principal investigator gave many invited lectures, disseminating the results to the meteorological community as well as the statistical community. A list of invited lectures at meetings is attached, as well as a list of departmental colloquia at various universities and institutes.

Wahba, Grace↗

Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters

Leonard Johnson published a methodology for establishing the confidence that two populations of data are different. Johnson's methodology is dependent on limited combinations of test parameters (Weibull slope, mean life ratio, and degrees of freedom) and a set of complex mathematical equations. In this report, a simplified algebraic equation for confidence numbers is derived based on the original work of Johnson. The confidence numbers calculated with this equation are compared to those obtained graphically by Johnson. Using the ratios of mean life, the resultant values of confidence numbers at the 99 percent level deviate less than 1 percent from those of Johnson. At a 90 percent confidence level, the calculated values differ between +2 and 4 percent. The simplified equation is used to rank the experimental lives of three aluminum alloys (AL 2024, AL 6061, and AL 7075), each tested at three stress levels in rotating beam fatigue, analyzed using the Johnson- Weibull method, and compared to the ASTM Standard (E739 91) method of comparison. The ASTM Standard did not statistically distinguish between AL 6061 and AL 7075. However, it is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers using the Johnson- Weibull analysis. AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median, or L(sub 50), lives

Vlcek, Brian L.↗

BLIND EXTRACTION OF AN EXOPLANETARY SPECTRUM THROUGH INDEPENDENT COMPONENT ANALYSIS

Blind-source separation techniques are used to extract the transmission spectrum of the hot-Jupiter HD189733b recorded by the Hubble/NICMOS instrument. Such a 'blind' analysis of the data is based on the concept of independent component analysis. The detrending of Hubble/NICMOS data using the sole assumption that nongaussian systematic noise is statistically independent from the desired light-curve signals is presented. By not assuming any prior or auxiliary information but the data themselves, it is shown that spectroscopic errors only about 10%-30% larger than parametric methods can be obtained for 11 spectral bins with bin sizes of {approx}0.09 {mu}m. This represents a reasonable trade-off between a higher degree of objectivity for the non-parametric methods and smaller standard errors for the parametric de-trending. Results are discussed in light of previous analyses published in the literature. The fact that three very different analysis techniques yield comparable spectra is a strong indication of the stability of these results.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct measurements of slip irreversibility in a nickel-based superalloy using high resolution digital image correlation

Fatigue crack nucleation in crystalline materials typically develops due to highly localized cyclic slip. During a fatigue cycle, reverse slip differs locally from slip in the forward direction particularly in precipitate-containing materials such as superalloys. In this paper we report the first direct measurements of irreversibility at the scale of individual slip bands by high-resolution digital image correlation (DIC) in a polycrystalline nickel-based superalloy. Quantitative measurements of the slip irreversibility are challenging for regions of material that have a size that captures the microstructure and its variability. High spatial resolution at the nanometer scale during experimental measurements is needed to observe slip localization during deformation. Moreover, large fields are also needed to obtain the material response over statistically representative populations of microstructural configurations. Recently, high resolution scanning electron microscope (SEM) digital image correlation (DIC) has been extended for quantitative analysis of discontinuities induced by slip events using the Heaviside-DIC method. Therefore, this novel method provides quantitative measurements of slip localization at the specimen surface. In this paper, the Heaviside-DIC method is used to measure slip irreversibility and plastic strain accumulation in a nickel-based superalloy. The method detects bands with high levels of irreversibility early in cycling that ultimately form fatigue cracks upon further cycling. The local microstructural configurations that induce large amounts of plasticity and slip irreversibility are correlated to crack nucleation locations.

36 MATERIALS SCIENCE↗

How do mirror charge radii constrain density dependence of the symmetry energy?

It has recently been suggested that differences in the charge radii of mirror nuclei (Δ$R^{mirr}_{ch}$) are strongly correlated with the neutron-skin thickness ($R_{skin}$) of neutron-rich nuclei and with the slope of the symmetry energy ($L$). To test this assumption, we present ab initio calculations of $R_{skin}$ in 48 Ca and 208 Pb, Δ$R^{mirr}_{ch}$ in 36 Ca$-$ 36 S, 38 Ca$-$ 38 Ar, 41 Sc$-$ 41 Ca, 48 Ni$-$ 48 Ca, 52 Ni$-$ 52 Cr, and 54 Ni$-$ 54 Fe mirror pairs, and $L$. Employing the recently developed 34 chiral interaction samples, identified by the history matching approach, we conduct rigorous statistical analysis of correlations among Δ$R^{mirr}_{ch}$, $R_{skin}$ and $L$, accounting for quantified uncertainties from low-energy constants of chiral interaction, chiral effective field theory truncation and many-body method approximation. The ab initio results reveal an appreciable Δ$R^{mirr}_{ch}$ $-$ $L$ correlation in $fp$-shell mirror pairs. However, contrary to previous studies, the present calculation finds that the studied $sd$-shell mirror pairs do not exhibit any Δ$R^{mirr}_{ch}$ $-$ $L$ correlation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗