Processed Lab Data for Neural Network-Based Shear Stress Level Prediction

Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a non-overlapping window from the original acoustic data. The first column is the time of the window. The second and third columns are the mean and the variance of the acoustic data in this window, respectively. The 4th-11th column is the the power spectrum density ranging from low to high frequency. And the last column is the corresponding label (shear stress level). The name of the file means which driving velocity the sequence is generated from. Data were generated from laboratory friction experiments conducted with a biaxial shear apparatus. Experiments were conducted in the double direct shear configuration in which two fault zones are sheared between three rigid forcing blocks. Our samples consisted of two 5-mm-thick layers of simulated fault gouge with a nominal contact area of 10 by 10 cm^2. Gouge material consisted of soda-lime glass beads with initial particle size between 105 and 149 micrometers. Prior to shearing, we impose a constant fault normal stress of 2 MPa using a servo-controlled load-feedback mechanism and allow the sample to compact. Once the sample has reached a constant layer thickness, the central block is driven down at constant rate of 10 micrometers per second. In tandem, we collect an AE signal continuously at 4 MHz from a piezoceramic sensor embedded in a steel forcing block about 22 mm from the gouge layer The data from this experiment can be used with the deep learning algorithm to train it for future fault property prediction.

15 GEOTHERMAL ENERGY↗

Aerial Captured Data and Processed Models in Beaumont-Port Arthur Region in Feb and Oct, 2023

Our Co-design team is from the University of Texas, working on a Department of Energy-funded project focused on the Beaumont-Port Arthur area. As part of this project, we will be developing climate-resilient design solutions for areas of the region. More on www.caee.utexas.edu.We used a DJI Mavic 2 Pro to capture aerial photos in Beaumont-Port Arthur, TX, in February 2023, including:I. Beaumont Soccer ClubII. Corps’ Port Arthur Resident OfficeIII. Halbouty Pump Station comprises its vicinityIV. Lamar University (Including Exxon Power Plants close to Lamar Univ.)V. MLK Boulevard for aerial images of the industry and the ship channelVI. Salt Water Barrier (include some aerial images about the Big Thicket)Aerial photos taken were through DroneDeploy autonomous flight, and models were processed through the DroneDeploy engine as well. All aerial photos are in .JPG format and contained in zipped files for each location.The processed data package including 3D models, geospatial data, mappings, point clouds, and the animation video of Halbouty Pump Station has various file types:- The Adobe Suite gives you great software to open .Tif files.- You can use LASUtility (Windows), ESRI ArcGIS Pro (Windows), or Blaze3D (Windows, Linux) to open a LAS file and view the data it contains.- Open an .OBJ file with a large number of free and commercial applications. Some examples include Microsoft 3D Builder, Apple Preview, Blender, and Autodesk.- You may use ArcGIS, Merkaartor, Blender (with the Google Earth Importer plug-in), Global Mapper, and Marble to open .KML files.- The .tfw world file is a text file used to georeference the GeoTIFF raster images, like the orthomosaic and the DSM. You need suitable software like ArcView to open a .TFW file.This dataset provides researchers with sufficient geometric data and the status quo of the land surface at the locations mentioned above. This dataset could streamline researchers' decision-making processes and enhance the design as well.In October 2023, we had our follow-up data collection, including:I. Beaumont Soccer ClubII. Shipping and Receiving Center at Lamar UniversityAfter the aerial collection, we obtained aerial photos of those two locations mentioned above, as well as processed data (such as point clouds and models).

2D mapping↗

Aerial Data and Processed Models of Port Arthur Coastal Neighborhood and Pleasure Island Golf Course, June 2024

Our Co-design team is from the University of Texas, working on a Department of Energy-funded project focused on the Beaumont-Port Arthur area. As part of this project, we will be developing climate-resilient design solutions for areas of the region. More on www.caee.utexas.edu.We captured aerial photos in the Port Arthur Coastal Neighborhood Community and the Golf Course on Pleasure Island, Texas, in June 2024.Aerial photos taken were through DroneDeploy autonomous flight, and models were processed through the DroneDeploy engine as well. All aerial photos are in .JPG format and contained in zipped files for each area.The processed data package includes 3D models, geospatial data, mappings, and point clouds. Please be aware that DTM, Elevation toolbox, Point cloud, and Orthomosaic use EPSG: 6588. And 3D Model uses EPSG: 3857.For using these data:- The Adobe Suite gives you great software to open .Tif files.- You can use LASUtility (Windows), ESRI ArcGIS Pro (Windows), or Blaze3D (Windows, Linux) to open a LAS file and view the data it contains.- Open an .OBJ file with a large number of free and commercial applications. Some examples include Microsoft 3D Builder, Apple Preview, Blender, and Autodesk.- You may use ArcGIS, Merkaartor, Blender (with the Google Earth Importer plug-in), Global Mapper, and Marble to open .KML files.- The .tfw world file is a text file used to georeference the GeoTIFF raster images, like the orthomosaic and the DSM. You need suitable software like ArcView to open a .TFW file.This dataset provides researchers with sufficient geometric data and the status quo of the land surface at the locations mentioned above. This dataset could streamline researchers' decision-making processes and enhance the design as well.

2D mapping↗

Real-time kinematic (RTK) Drone-collected Data and Processed Models of Port Arthur Coastal Neighborhood and Pleasure Island Golf Course, June 2024

The Southeast Texas Urban Integrated field lab’s Co-design team captured aerial photos in the Port Arthur Coastal Neighborhood Community and the Golf Course on Pleasure Island, Texas, in June 2024. Aerial photos taken were through autonomous flight, and models were processed through the DroneDeploy engine. All aerial photos are in .JPG format and contained in zipped files for each area. The processed data package includes 3D models, geospatial data, mappings, and point clouds. Please be aware that DTM, Elevation toolbox, Point Cloud, and Orthomosaic use EPSG: 6588. And 3D Model uses EPSG: 3857.For using these data:- The Adobe Suite gives you great software to open .Tif files.- You can use LASUtility (Windows), ESRI ArcGIS Pro (Windows), or Blaze3D (Windows, Linux) to open a LAS file and view the data it contains.- Open an .OBJ file with a large number of free and commercial applications. Some examples include Microsoft 3D Builder, Apple Preview, Blender, and Autodesk.- You may use ArcGIS, Merkaartor, Blender (with the Google Earth Importer plug-in), Global Mapper, and Marble to open .KML files.- The .tfw world file is a text file used to georeference the GeoTIFF raster images, like the orthomosaic and the DSM. You need suitable software like ArcView to open a .TFW file.This dataset provides researchers with sufficient geometric data and the status quo of the land surface at the locations mentioned above. This dataset will support researchers' decision-making processes under uncertainties.

2D mapping↗

A Data-Driven Framework for Automated Detection of Aircraft-Generated Signals in Seismic Array Data Using Machine Learning

Abstract Ground motions associated with aircraft overflights can cover a significant portion of the seismic data collected by shallowly emplaced seismometers, such as new nodal and Distributed Acoustic Sensing systems. This article describes the first published framework for automated detection of aircraft on single channel and multichannel seismic data. The seismic data are converted to spectrograms in a sliding time window and classified as aircraft or nonaircraft in each window using a deep convolutional neural network trained with analyst-labeled data. A majority voting scheme is used to convert the output from the sequence of sliding time windows onto a decision time sequence for each channel and to combine the binary classifications on the decision time sequences across multiple channels. Precision, recall, and F-score are used to quantify the detection performance of the algorithm on nodal data using fourfold time-series cross validation. By applying our framework to data from the Sage Brush Flats nodal array in Southern California, we provide a benchmark performance and demonstrate the advantage of using an array of sensors.

Geochemistry & Geophysics↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

Evaluation and Testing of the ADVANTG Code on SNM Detection

Pacific Northwest National Laboratory (PNNL) has been tasked with evaluating the effectiveness of ORNL’s new hybrid transport code, ADVANTG, on scenarios of interest to our NA-22 sponsor, specifically of detection of diversion of special nuclear material (SNM). PNNL staff have determined that acquisition and installation of ADVANTG was relatively straightforward for a code in its phase of development, but probably not yet sufficient for mass distribution to the general user. PNNL staff also determined that with little effort, ADVANTG generated weight windows that typically worked for the problems and generated results consistent with MCNP. With slightly greater effort of choosing a finer mesh around detectors or sample reaction tally regions, the figure of merit (FOM) could be further improved in most cases. This does take some limited knowledge of deterministic transport methods. The FOM could also be increased by limiting the energy range for a tally to the energy region of greatest interest. It was then found that an MCNP run with the full energy range for the tally showed improved statistics in the region used for the ADVANTG run. The specific case of interest chosen by the sponsor is the CIPN project from Las Alamos National Laboratory (LANL), which is an active interrogation, non-destructive assay (NDA) technique to quantify the fissile content in a spent fuel assembly and is also sensitive to cases of material diversion. Unfortunately, weight windows for the CIPN problem cannot currently be properly generated with ADVANTG due to inadequate accommodations for source definition. ADVANTG requires that a fixed neutron source be defined within the problem and cannot account for neutron multiplication. As such, it is rendered useless in active interrogation scenarios. It is also interesting to note that this is a difficult problem to solve and that the automated weight windows generator in MCNP actually slowed down the problem. Therefore, PNNL had determined that there is not an effective tool available for speeding up MCNP for problems such as the CIPN scenario. With regard to the Benchmark scenarios, ADVANTG performed very well for most of the difficult, long-running, standard radiation detection scenarios. Specifically, run time speedups were observed for spatially large scenarios, or those having significant shielding or scattering geometries. ADVANTG performed on par with existing codes for moderate sized scenarios, or those with little to moderate shielding, or multiple paths to the detectors. ADVANTG ran slower than MCNP for very simply, spatially small cases with little to no shielding that run very quickly anyway. Lastly, ADVANTG could not solve problems that did not consist of fixed source to detector geometries. For example, it could not solve scenarios with multiple detectors or secondary particles, such as active interrogation, neutron induced gamma, or fission neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Visual Sample Plan Version 7.0 User's Guide

User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

97 MATHEMATICS AND COMPUTING↗

Analysis of the Chinese Market for Building Energy Efficiency

China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies on building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal Studies of the Laser Inertial Fusion Energy (LIFE) Target during Injection into the Fusion Chamber

The tests of the external heat transfer coefficient suggests that the values used in the numerical analysis for the temperature distribution within the fusion fuel target following flight into the target chamber are probably valid. The tests of the heat transfer phenomena occurring within the target due the rapid heating of the LEH window for the hot gasses within the fusion chamber show that the heat does indeed convect via the internal helium environment of the target towards the capsule and that the pressure in the front compartment of the target adjacent to the LEH window increases such that t bypass venting of the internal helium into the second chamber adjacent to the capsule is needed to prevent rupture of the membranes. The bypass flow is cooled by the hohlraum during this venting. However, the experiments suggest that our internal heat flow calculations may be low by about a factor of 2. Further studies need to be conducted to investigate the differences between the experiment and the numerical analysis. Future studies could also possibly bring the test conditions closer to those expected in the fusion chamber to better validate the results. A sacrificial layer will probably be required on the LEH window of the target and this can be used to mitigate any unexpected target heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Policy, Permit, Perform: Using City Benchmarking Data and Building Construction Permit History to Identify Energy Performance Improvements

The City of Portland (City) and Multnomah County 2015 Climate Action Plan targets a 40 percent reduction in carbon emissions below 1990 levels by 2030. To reach this goal, the plan includes a key objective to reduce the total energy use of existing buildings by 25 percent. Buildings are responsible for one-half of carbon emissions in Portland, Oregon, U.S., and improving their performance is critical to achieving the City’s climate goals. As part of its climate action planning, the City passed an ordinance on April 22, 2015, requiring commercial buildings 20,000 ft2 and larger to benchmark and disclose annual energy performance metrics through ENERGY STAR® Portfolio Manager® (ESPM), including greenhouse gas emissions, building energy use intensity (EUI) and ENERGY STAR scores. Twenty-five cities in the U.S. have adopted similar policies requiring energy benchmarking. These policies are generating a treasure trove of data about the drivers of building performance, but practitioners are only beginning to link benchmarking data to other datasets to produce actionable insight into improving building performance. In 2016, the City received a financial assistance award from the U.S. Department of Energy (DOE) through the Cities Leading through Energy Analysis and Planning project (Award Number DE-0007737). Portland’s project evaluated the application of the DOE Building Energy Asset Score Tool and rating system developed by Pacific Northwest National Laboratory (PNNL) to commercial buildings that report to the City. The City used building construction permit history to develop Asset Scores for a set of office buildings that reported energy performance for 2015 – the first year the City mandated energy benchmarking and reporting for commercial buildings 50,000 ft2 and larger. The primary project objective was to link energy benchmarking data and commercial building permit data to analyze commercial buildings systems that present the best, specific opportunities to improve energy performance. Integrating these datasets from two City departments, the Bureau of Development Services and the Bureau of Planning and Sustainability, could expand Portland’s use of analytics to inform climate policy decisions and strategic targeting of financial incentives for building owners and managers who are best positioned to improve the performance of their buildings. The project began with the commercial benchmarking data received for 340 commercial buildings that submitted calendar year 2015 energy reports. The City retained Research Into Action and Energy 350 (RIA team) to evaluate this self-reported benchmarking data. Based on a survey of 53 building managers, the RIA team found that most respondents used the City’s compliance tools, including a How-to Guide and Help Desk, and found access to utility data to be straightforward. However, almost one-third of the respondents encountered challenges when estimating the gross floor area (GFA), and some experienced confusion regarding the input of property use types and details into ESPM. Based on the RIA team’s recommendations, the City refined its How-to Guide, created online answers to frequently asked questions, and hosted office hour sessions to help building managers accurately characterize their building’s physical characteristics and operations in ESPM. Concurrently with the RIA team’s evaluation, the City worked with PNNL to estimate DOE Asset Score Preview (Preview) scores for 181 of the 340 commercial buildings that submitted ESPM reports to the City. Asset Score Tool is a web-based tool developed by PNNL for DOE to evaluate and rate the as-built energy efficiency of a building. Asset Score Tool’s full analysis capability runs a detailed energy model based on building geometry, age, envelope, lighting and mechanical systems using standard operating assumptions to give the building a score, similar to a miles per gallon rating for a car. Preview, a simplified deployment of the full Asset Score Tool, provides a preliminary score range using only seven data points, six of which are readily available in the ESPM benchmarking data. Analysis of the combined Preview scores and the operational ESPM scores identified buildings with a high potential for energy improvements through either retro-commissioning and retuning of existing operations or capital investments into building systems. The City contracted Whole Building Solutions (WBS) to mine building permit history and develop full Asset Scores for a subset of 26 office buildings that were eligible for both ENERGY STAR scores and Asset Scores. WBS researched permits and building plans to identify mechanical, lighting and envelope systems and other building characteristics necessary to complete Asset Scores. This historical data was recorded using the web-based Asset Score Tool, which evaluates the as designed energy efficiency of existing buildings. Much of this City information was available online after 2010; however, WBS had to search through microfiche files and the City’s database to obtain permit and plan history prior to 2010. Although building geometry, mechanical system type and basic envelope information was consistently identifiable, WBS found permit data gaps that prevented complete and accurate Asset Scores for most of the office buildings. If the City decides to develop Asset Scores based on building permit information in the future, WBS recommended requiring lighting plans, control diagrams and as-built drawings that reflect how the buildings are actually constructed. In addition, WBS recommended uploading plans and permits from microfiche storage into a more comprehensive, searchable database consistent with the City’s current online permit information. To identify the actual lighting types, WBS and City staff conducted site visits of all 26 office buildings. As part of managing the flow of ESPM and Asset Score data for the project, Earth Advantage, a sub-recipient of the Cities-LEAP award, created a DOE Standard Energy Efficiency Data (SEED) (USDOE 2018) instance for the City and used Asset Score’s Application Programming Interface (API) (Asset Score 2018) capabilities to develop two new features in the SEED Platform™: (1) automated Asset Score Preview ranges calculated based on benchmarking data and the City’s estimate of number of building floors; and (2) storage of full Asset Score information. Leveraging the construction permit history and site visit information for the 26 office buildings, The Cadmus Group (Cadmus) analyzed benchmarking data and Asset Score information to identify opportunities and drivers to improve performance. Correlation and regression analysis of the combined dataset was completed to determine whether building operations or specific systems – mechanical, lighting or envelope – present the best opportunities to improve energy performance. The central outcome of this project was Cadmus’ detailed analysis of the richer dataset that was created by combining the City of Portland’s commercial building permit activity and building-specific energy performance information based on metrics from ESPM and Asset Score Tool. Some of their findings collaborate with well-known facts, such as buildings with less efficient lighting systems are good targets for efficiency improvements through lighting upgrades. This analysis also helped identify that individual heating, ventilation, and air conditioning (HVAC) equipment efficiency does not necessarily correlate with building performance. However, overall HVAC system performance, as measured with the Total System Performance Ratio (TSPR) metric, is a better indicator of building performance (Goel et al. 2014). As a metric, TSPR considers whole system performance that includes equipment efficiency and system controls, such as resets for static pressure and chilled water setpoints, which can be more effective and financially feasible options for improving building performance. Given the high cost associated with envelope retrofits, opportunities to upgrade envelope insulation are likely to be limited. However, buildings with single-pane and non-thermal break windows are good candidates for window replacements, such as upgrading to double-pane windows with thermal breaks. This research project determined that developing Asset Scores based on site visits is preferable to mining City building permit data. In addition, the use of benchmarking data to develop Asset Score Preview Scores is recommended as a first step in engaging building managers to develop full Asset Scores. Asset Score Tool outputs can help building managers quickly identify opportunities for improvement and then work with the utility incentive administrator and energy service providers to develop their retrofit plan. Where full Asset Scores are available, analysis using a quadrant matrix with ENERGY STAR scores is recommended to identify buildings that present the best opportunities for operational-behavioral improvements versus ones with opportunities for upgrades to physical building systems. This workflow and the tools will help cities, utility incentive administrators, building portfolio managers and energy service providers develop energy programs and strategies for screening and analysis of buildings with the greatest energy savings potential. This report describes the project approach and research results to inform future coordination of ESPM and Asset Score data, including the use of benchmarking data to generate Preview scores. Given better awareness of energy performance, building managers can make more informed decisions to reduce energy consumption and carbon emissions. With cities, states and jurisdictions adopting benchmarking and auditing ordinances, there are substantial amounts of data submitted to cities that could be used to inform investments in energy efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High power coupler development for EIC

The synchrotron radiation loss in EIC Electron Storage Ring is as high as up to 10 MW. This energy loss will be compensated by 17 2K 591 MHz single-cell SRF cavities with a combined total of 34 high power fundamental power couplers. Each power coupler will operate 92% of revolution time CW and ~8% of revolution time with 400 kW forward power due to the beam abort gap. To satisfy the EIC needs, we developed two 500 kW standing-wave FPC designs at BNL based on either a BeO and an Al 2 O 3 RF window. This paper will briefly summarize test results of the BeO window FPC , and describe the design development of the Al 2 O 3 window based FPC.

43 PARTICLE ACCELERATORS↗

Climate-Relevant Gas Absorption Properties from AWARE and Other ARM Spectral Measurements (Final Report)

The objective of this project has been to use measurements from the Atmospheric Emitted Radiance Interferometer (AERI) deployed at ARM sites to improve our knowledge of uncertain infrared spectroscopic parameters of importance to climate, remote sensing, and data assimilation. A primary focus has been the water vapor continuum in the infrared atmospheric window. Radiation codes used to predict climate and weather base their representation of the water vapor continuum in this window on the MT_CKD model, but in this spectral region the MT_CKD water vapor continuum absorption coefficients were derived almost two decades ago by an analysis of AERI measurements for conditions with a limited range of precipitable water vapor (PWV) and temperature values, leading to uncertainty in the derived coefficients. This project has included a new, comprehensive analysis of all aspects of the water vapor continuum in the atmospheric window -- the self continuum, the foreign continuum, and the self continuum temperature dependence, all resolved spectrally. Having a wide range of PWV amounts and temperatures from deployments of the ARM Mobile Facility for GoAmazon as well as the more than a decade of AERI measurements at SGP has provided an appropriate foundation for such a comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Residential Façade Upgrades: Market Assessment and Recommendations

In support of DOE’s move toward transformational whole-building upgrades and enclosure solutions, the Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) are partnering and collaborating with leading building science researchers and home-performance entities to identify and characterize technical and economic barriers to façade retrofits in an effort to identify market-viable façade solutions and opportunities for an actionable plan to transform the market. The project includes partnerships with Building Science Corporation (BSC) and a combination of strategic implementation partners with home-performance and retrofit expertise and industry contacts. The project will include expert advisory and review consultation from Lawrence Berkeley National Laboratory’s (LBNL’s) Residential Windows & Attachments team and Oak Ridge National Laboratory’s Building Envelope team. The project consists of three parts: 1. a market analysis that captures the current state of the façade retrofit market and includes housing characteristics and retrofit costs, façade retrofit approaches and materials, contractor business models and workforce requirements to support advanced façade approaches; 2. an economic analysis focused on the viability of advanced façade retrofit approaches and materials; and 3. field demonstration of façade retrofits that include enhanced insulation/air-sealing and window technologies in multiple climate zones. This report represents the market analysis, as outlined in item 1 above. The goal of this analysis is to provide a techno-economic study that supports comprehensive retrofits of residential enclosures that include traditional approaches, and integrated wall assemblies and windows that result in durable, energy efficient, and marketable strategies. This study will provide a better knowledge base regarding the viable market for façade retrofit strategies, identify the barriers to uptake, analyze economic opportunities, and develop documentation specifically aimed to overcome technical and market barriers associated with installation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Production of Optimization-Based Control Logics for Dynamic Facade Systems, with Experimental Application to Two-Zone External Venetian Blinds

The primary goal of this research is to devise a system that produces controllers for complex fenestration systems that perform nearly as well as Model Predictive Control but at a level of cost and implementation complexity that rivals simple heuristic controls. To this end, a cloud-based automated controller production system has been set up for a motorized external Venetian blind device, with a simple web interface that can be used by non-experts. The computation cost per controller is in the range of a few dollars, and the control logic is simple enough to be implemented on small and cheap distributed controllers. The web interface allows the user to specify some details of their particular building and window configuration, including orientation, latitude, interior geometries, and lighting and HVAC system parameters. Upon submittal, a cloud-based system configures the necessary files and commands, and then runs thousands of optimizations with them. Once the calculations are finished, the system produces a lookup table and interpolation-based controller scripts that can be used on a simple and cheap distributed controller. This paper describes the underlying models and optimization processes. It also describes the resulting control logics for two cases tested at Lawrence Berkeley National Laboratory’s Advanced Windows Testbed Facility: illuminance maximization subject to glare constraints; and lighting + HVAC energy minimization. The performance of the model-based controllers produced by the automated web-based system are compared to a heuristic ‘block beam’ controller in physical experiments at the Testbed. The experimental results are supplemented by simulation experiments with the same configuration as the Testbed. The results show the illuminance maximizing controller significantly outperforms the heuristic controller in terms of glare avoidance, and also outperforms it in terms of hours of daylight autonomy. The energy minimizing controller also outperforms the heuristic controller. This paper also discusses how the web-based system may be extended to consider other configurations, such as electrochromic windows and thermally massive HVAC systems. Potential roles for this type of system within the building design and construction industry are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement Acceptance Region (MAR) Assessment Results Based On Sludge Batch 10 Projections from December 2021, February 2022 and August 2022

The Defense Waste Processing Facility (DWPF) is currently preparing to initiate processing of Sludge Batch 10 (SB10), which is comprised of material from Tanks 11H, 13H, 15H, and 26F, Alternate Feed Stock-2 and Sodium Reactor Experiment material from H-Canyon. Frit 473 (8B 2 O 3 -8Li 2 O-5Na 2 O-79SiO 2 , in weight percent) was recommended for sludge-only (SO) and coupled processing with the Salt Waste Processing Facility (SWPF) based on previous assessments of SB10 projections with the DWPF Product Composition Control System (PCCS) glass property models and their associated Measurement Acceptance Region (MAR) constraints. Due to the lower processing rate of Sludge Batch 9 (SB9), the heel in Tank 40 is anticipated to be greater than 40 inches at the projected start of SB10 processing to meet the upcoming Accelerated Basin Deinventory addition dates in Tank 51 for Sludge Batch 11. In December 2021 and February 2022, Savannah River Remediation System Planning provided updated SB10 Tank 40 blend projections based on heels of 74 inches, 84 inches, 94 inches and 103.4 inches. Savannah River Mission Completion (SRMC) subsequently pursued Wash Cycle Y to further reduce the total sulfur in the sludge batch and increase processing flexibility at DWPF. In August 2022, SRMC System Planning provided an updated SB10 Tank 40 blend projection with a 76 inch-heel representing Decant Y2 and 60 kilogallons of bearing water inleakage that is anticipated during the Tank 51 to Tank 40 transfer. The objectives of this task were to: • Determine the impact on the operating windows for SO and coupled processing • Determine whether any composition gaps exist between the already completed SB10 variability study and the reprojected SB10 glass composition region • Compare the SB10 reprojected glass composition region to the DWPF PCCS model development and validation ranges to ensure that compositional gaps do not exist between the data sets. This report documents the results of these evaluations. Calculation-based frit assessments were performed using the DWPF PCCS glass property models and their associated MAR constraints. Evaluated parameters for coupled processing included the following transfer volumes per Sludge Receipt and Adjustment Tank batch: 5700 gallons of Tank 40 sludge, 2400-4500 gallons of the SWPF monosodium titanate (MST) and sludge solids stream, and 15,000 gallons of strip effluent. Based on these MAR assessment results, Frit 473 remains viable for SB10 processing. A target waste loading (WL) of 36% is possible for SO operation and single strike (0.4 g/L MST) coupled processing up to 600 mg/L of SB9 insoluble sludge solids at a nominal transfer volume of ~2800 gallons. Increasing the single strike transfer volume to 4500 gallons may reduce the maximum WL below 40%. Operating windows are 12 percentage points for SO processing and 14-16 percentage points for coupled processing. Frit 625 allows for a target WL of 36% and is acceptable for use during the SB9 to SB10 transition to deplete remaining inventory as needed. Operating windows are 8 percentage points for SO processing and 12-14 percentage points for coupled processing. Predictive PCCS evaluations performed at DWPF will provide insight into batch-specific acceptability at desired WLs for compositions having expected oxide ratios during processing versus the extreme vertices (corner points) evaluated in this study. The reprojected SB10 glass composition region generally overlaps the previously evaluated SB10 variability study composition region. Thus, the minor composition shift of these updated SB10 projections indicates that no additional glasses are necessary to demonstrate acceptability relative to the chemical durability of the Environmental Assessment benchmark glass and predictability using the current PCCS models for durability. Based on a comparison of the PCCS model development and validation data to the reprojected SB10 glass composition region, the viscosity and liquidus temperature models will reliably predict SB10 compositions. No additional glasses are necessary to demonstrate predictability of these models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.