Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Feasibility study on the design of a probe for rectal cancer detection

Rectal examination techniques are considered in terms of detection capability, patient acceptance, and cost reduction. A review of existing clinical techniques are considered in terms of detection capability, patient acceptance, and cost reduction. A review of existing clinical techniques and of relevant aerospace technology included evaluation of the applicability of visual, thermal, ultrasound, and radioisotope modalities of examination. The desired improvements can be obtained by redesigning the proctosigmoidoscope to have reduced size, additional visibility, and the capability of readily providing a color photograph of the entire rectosigmoid mucosa in a single composite view.

Anselm, V. J.↗

Cardiovascular and pulmonary dynamics by quantitative imaging

The accuracy and range of studies on cardiovascular and pulmonary functions can be greatly facilitated if the motions of the underlying organ systems throughout individual cycles can be directly visualized and readily measured with minimum or preferably no effect on these motions. Achievement of this objective requires development of techniques for quantitative noninvasive or minimally invasive dynamic and stop-action imaging of the organ systems. A review of advances in dynamic quantitative imaging of moving organs reveals that the revolutionary value of cross-sectional and three-dimensional images produced by various types of radiant energy such as X-rays and gamma rays, positrons, electrons, protons, light, and ultrasound for clinical diagnostic and biomedical research applications is just beginning to be realized. The fabrication of a clinically useful cross-section reconstruction device with sensing capabilities for both anatomical structural composition and chemical composition may be possible and awaits future development.

Wood, E. H.↗

The Stanford-Ames portable echocardioscope - A case study in technology transfer

The paper describes a lightweight portable battery-powered echocardioscope fabricated largely from readily available components. The transducer contains a piezoelectric crystal which acts as both an ultrasound pulse emitter and echo receiver, and the oscilloscope is of modular construction. The oscilloscope display can be produced in any of three different modes: A-mode, B-mode, and M-mode (time-motion) by sweeping the intensified points of light of the B-mode display vertically along the oscilloscope face. The resulting display can be photographed in a time exposure, thus providing a hardcopy record for the patient's chart or physician's records. The device is clinically validated on both normal subjects and patients by experienced echocardiographers.

Schmidt, G.↗

High-resolution echocardiography

High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.

Nathan, R.↗

Sound and Noise

The effects of audible sound and noise, infrasound, and ultrasound on man are discussed. Those factors which have potential relevance to the space flight situation are emphasized.

J L Homick↗

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.↗

Ultrasonic and optical evaluation of surgical implant materials and devices. A durability study of pericardial bioprostheses

Laser Doppler Anemometry (LDA) and accelerated fatigue testing were used in an attempt to assess the durability of two cardiac value bioprostheses. The LDA system was used to monitor the function of the cardiac valves over time. This was done through flow characterization in an aortic flow chamber, designed to closely simulate in vivo conditions, both in the near vicinity (sinuses of valsalva region) and also somewhat downstream (aortic region) from the values. The accelerated fatigue tester was operated by opening and closing the valves at a rate of 1300 R.P.M., about 18 x the normal rate. The results from the two test valves indicate a definite change in the flow characteristics downstream from the valve after certain accelerated test intervals. The high velocity cross-sectional flow area seems to increase over time in use, causing a decrease in the peak velocity. The tissue became more flaccid in certain areas, and tears were apparent at about 9.4 million cycles for the Ionescu-Shiley valve and at 24 million cycles for the Carpentier-Edwards valve. The use of Doppler ultrasound as a technique for monitoring the function of bioprostheses over time in vivo is also discussed.

Schuster, P. R.↗

Pulmonary artery location during microgravity activity: Potential impact for chest-mounted Doppler during space travel

Doppler, or ultrasonic, monitoring for pain manifestations of decompression sickness (the bends) is accomplished by placing a sensor on the chest over the pulmonary artery and listening for bubbles. Difficulties have arisen because the technician notes that the pulmonary artery seems to move with subject movement in a one-g field and because the sensor output is influenced by only slight degrees of sensor movement. This study used two subjects and mapped the position of the pulmonary artery in one-g, microgravity, and two-g environments using ultrasound. The results showed that the pulmonary artery is fixed in location in microgravity and not affected by subject position change. The optimal position corresponded to where the Doppler signal is best heard with the subject in a supine position in a one-g environment. The impact of this result is that a proposed multiple sensor array on the chest proposed for microgravity use may not be necessary to monitor an astronaut during extravehicular activities. Instead, a single sensor of approximately 1 inch diameter and mounted in the position described above may suffice.

Hadley, A. T., III↗

Applications of aerospace technology in biology and medicine

Utilization of NASA technology and its application to medicine is discussed. The introduction of new or improved commercially available medical products and incorporation of aerospace technology is outlined. A biopolar donor-recipient model of medical technology transfer is presented to provide a basis for the methodology. The methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the ocular screening device, a system for quick detection of vision problems in preschool children, and Porta-Fib III, a hospital monitoring unit. Two institutional transfers were completed: implant materials testing, the application of NASA fracture control technology to improve reliability of metallic prostheses, and incinerator monitoring, a quadrupole mass spectrometer to monitor combustion products of municipal incinerators. Mobility aids for the blind and ultrasound diagnosis of burn depth are also studied.

Rouse, D. J.↗

Diagnostic imaging applications; Proceedings of the Meeting, Amsterdam, Netherlands, October 8, 9, 1984

It is more important than ever that engineers have an understanding of the future needs of clinical and research medicine, and that physicians know somthing about probable future developments in instrumentation capabilities. Only by maintaining such a dialog can the most effective application of technological advances to medicine be achieved. This workshop attempted to provide this kind of information transfer in the limited field of diagnostic imaging. Biomedical research at the Jet Propulsion Laboratory is discussed, taking into account imaging results from space exploration missions, as well as biomedical research tasks based in these technologies. Attention is also given to current and future indications for magnetic resonance in medicine, high speed quantitative digital microscopy, computer processing of radiographic images, computed tomography and its modern applications, position emission tomography, and developments related to medical ultrasound.

Beckenbach, E. S.↗

Ultrasonic angle beam standard reflector

A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

Berry, R. F., Jr.↗

Analytical ultrasonics for evaluation of composite materials response. Part 2: Generation and detection

To evaluate the response of composite materials, it is imperative that the input excitation as well as the observed output be well characterized. This characterization ideally should be in terms of displacements as a function of time with high spatial resolution. Additionally, the ability to prescribe these features for the excitation is highly desirable. Various methods for generating and detecting ultrasound in advanced composite materials are examined. Characterization and tailoring of input excitation is considered for contact and noncontact, mechanical, and electromechanical devices. Type of response as well as temporal and spatial resolution of detection methods are discussed as well. Results of investigations at Virginia Tech in application of these techniques to characterizing the response of advanced composites are presented.

Duke, J. C., Jr.↗

Ultrasonic verification of microstructural changes due to heat treatment

Ultrasonic attenuation was measured for polycrystalline samples of nickel and copper with various grain-size distributions produced by heat treatment. Attenuation as a function of frequency was determined for a sample having a known mean grain diameter. Once this function was determined, it could be scaled to determine the mean grain size of other samples of the same material with different mean grain diameters. These results were obtained by using broadband pulse-echo ultrasound in the 25 to 100 MHz frequency range. The results suggest an ultrasonic, nondestructive approach for verifying heat treatment of metals.

Generazio, E. R.↗

Scaling attenuation data characterizes changes in material microstructure

Ultrasonic attenuation was measured for polycrystalline samples of nickel and copper with various grain-size distributions produced by heat treatment. Attenuation as a function of frequency was determined for a sample having a known mean grain diameter D. It was found that, once this function is determined, it can be scaled to determine the mean grain size of other samples of the same material with different mean grain diameters. These results were obtained using broadband pulse-echo ultrasound in the 25 to 100 MHz frequency range. The results suggest an ultrasonic, nondestructive approach for verifying heat treatment of metals.

Generazio, E. R.↗

Ultrasonic verification of microstructural changes due to heat treatment

Ultrasonic attenuation was measured for polycrystalline samples of nickel and copper with various grain-size distributions produced by heat treatment. Attenuation as a function of frequency was determined for a sample having a known mean grain diameter. Once this function was determined, it could be scaled to determine the mean grain size of other samples of the same material with different mean grain diameters. These results were obtained by using broadband pulse-echo ultrasound in the 25 to 100 MHz frequency range. The results suggest an ultrasonic, nondestructive approach for verifying heat treatment of metals.

Generazio, E. R.↗

Concepts for the evolution of the Space Station Program

An evaluation is made of innovative but pragmatic waste management, interior and exterior orbital module construction, Space Shuttle docking, orbital repair operation, and EVA techniques applicable to the NASA Space Station program over the course of its evolution. Accounts are given of the Space Shuttle's middeck extender module, an on-orbit module assembly technique employing 'Pringles' stack-transportable conformal panels, a flexible Shuttle/Space Station docking tunnel, an 'expandable dome' for transfer of objects into the Space Station, and a Space Station dual-hatch system. For EVA operations, pressurized bubbles with articulating manipulator arms and EVA hard suits incorporating maneuvering, life support and propulsion capabilities, as well as an EVA gas propulsion system, are proposed. A Space Station ultrasound cleaning system is also discussed.

Michaud, Roger B.↗

Physiologic adaptation of man in space; Proceedings of the Seventh International Man in Space Symposium, Houston, TX, Feb. 10-13, 1986

Topics discussed in this volume include space motion sickness, cardiovascular adaptation, fluid shifts, extravehicular activity, general physiology, perception, vestibular response modifications, vestibular physiology, and pharmacology. Papers are presented on the clinical characterization and etiology of space motion sickness, ultrasound techniques in space medicine, fluid shifts in weightlessness, Space Shuttle inflight and postflight fluid shifts measured by leg volume changes, and the probability of oxygen toxicity in an 8-psi space suit. Consideration is also given to the metabolic and hormonal status of crewmembers in short-term space flights, adaptive changes in perception of body orientation and mental image rotation in microgravity, the effects of a visual-vestibular stimulus on the vestibulo-ocular reflex, rotation tests in the weightless phase of parabolic flight, and the mechanisms of antimotion sickness drugs.

Holland, Albert W.↗