Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Discrete-time quantum walk approach to state transfer

We show that a quantum-state transfer, previously studied as a continuous-time process in networks of interacting spins, can be achieved within the model of discrete-time quantum walks with a position-dependent coin. We argue that, due to additional degrees of freedom, discrete-time quantum walks allow one to observe effects which cannot be observed in the corresponding continuous-time case. First, we study a discrete-time version of the engineered coupling protocol due to Christandl et al. [Phys. Rev. Lett. 92, 187902 (2004)] and then we discuss the general idea of conversion between continuous-time quantum walks and discrete-time quantum walks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering

A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.

36 MATERIALS SCIENCE↗

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Detection

The time series of data from a Radiation Portal Monitor (RPM) system are evaluated for the presence of point sources by isolating the contribution of anomalous radiation. Energy-windowed background spectra taken from the RPM are compared with the observed spectra at each time step during a vehicle drive-through. The total signal is turned into a spectral distance index using this method. This provides a time series with reduced systematic fluctuations due to background attenuation by the vehicle, and allows for point source detection by time-series analyses. The anomalous time series is reanalyzed by using a wavelet filter function of similar size to the expected source profile. A number of real drive-through data sets taken at a U.S. port of entry are analyzed in this way. A set of isotopes are injected into the data set, and the resultant benign and injected data sets are analyzed with gross-counting, spectral-ratio, and time-based algorithms. Spectral and time methods together offer a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular radiotherapy: The NUKFIT software for calculating the time-integrated activity coefficient

Purpose: Calculation of the time-integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time-integrated activity coefficient and its standard error.Methods: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user-friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time-integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of <1%. The differences for the time-integrated activity coefficients were also <1% (standard error between 0.4% and 3%). In general, the application of the software is user-friendly and the results are mathematically correct and reproducible. An application of NUKFIT is presented for three different clinical examples.Conclusions: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AIR Algebraic Multigrid for a Space-Time Hybridizable Discontinuous Galerkin Discretization of Advection(-Diffusion)

This article investigates the efficiency, robustness, and scalability of approximate ideal restriction (AIR) algebraic multigrid as a preconditioner in the all-at-once solution of a space-time hybridizable discontinuous Galerkin discretization of advection-dominated flows. The motivation for this study is that the time-dependent advection-diffusion equation can be seen as a “steady” advection-diffusion problem in $(d+1)$-dimensions and AIR has been shown to be a robust solver for steady advection-dominated problems. Numerical examples demonstrate the effectiveness of AIR as a preconditioner for advection-diffusion problems on fixed and time-dependent domains, using both slab-by-slab and all-at-once space-time discretizations, and in the context of uniform and space-time adaptive mesh refinement. A closer look at the geometric coarsening structure that arises in AIR also explains why AIR can provide robust, scalable, space-time convergence on advective and hyperbolic problems, while most multilevel parallel-in-time schemes struggle with such problems.

97 MATHEMATICS AND COMPUTING↗

Adaptive Time Step Control for Multirate Infinitesimal Methods

Multirate methods have been used for decades to temporally evolve initial-value problems in which different components evolve on distinct time scales, and thus use of different step sizes for these components can result in increased computational efficiency. Generally, such methods select these different step sizes based on experimentation or stability considerations. For problems that evolve on a single time scale, adaptivity approaches that strive to control local temporal error are widely used to achieve numerical results of a desired accuracy with minimal computational effort, while alleviating the need for manual experimentation with different time step sizes. However, there is a notable gap in the publication record on the development of adaptive time step controllers for multirate methods. In this paper, we extend the single-rate controller work of Gustafsson [ACM Trans. Math. Software, 20 (1994), pp. 496-517] to the multirate method setting. Specifically, we develop controllers based on polynomial approximations to the principal error functions for both the "fast" and "slow" time scales within multirate infinitesimal (MRI) methods. We additionally investigate a variety of approaches for estimating the errors arising from each time scale within MRI methods. We then numerically evaluate the proposed multirate controllers and error estimation strategies on a range of multirate test problems, comparing their performance against an estimated optimal performance. Through this work, we combine the most performant of these approaches to arrive at a set of multirate adaptive time step controllers that robustly achieve desired solution accuracy with minimal computational effort.

97 MATHEMATICS AND COMPUTING↗

Parallel-in-Time Solution of Scalar Nonlinear Conservation Laws

Here, we consider the parallel-in-time solution of scalar nonlinear conservation laws in one spatial dimension. The equations are discretized in space with a conservative finite-volume method using weighted essentially nonoscillatory (WENO) reconstructions, and in time with high-order explicit Runge–Kutta methods. The solution of the global, discretized space-time problem is sought via a nonlinear iteration that uses a novel linearization strategy in cases of nondifferentiable equations. Under certain choices of discretization and algorithmic parameters, the nonlinear iteration coincides with Newton’s method, although, more generally, it is a preconditioned residual correction scheme. At each nonlinear iteration, the linearized problem takes the form of a certain discretization of a linear conservation law over the space-time domain in question. An approximate parallel-in-time solution of the linearized problem is computed with a single multigrid reduction-in-time (MGRIT) iteration; however, any other effective parallel-in-time method could be used in its place. The MGRIT iteration employs a novel coarse-grid operator that is a modified conservative semi-Lagrangian discretization and generalizes those we have developed previously for nonconservative scalar linear hyperbolic problems. Numerical tests are performed for the inviscid Burgers and Buckley–Leverett equations. For many test problems, the solver converges in just a handful of iterations with a convergence rate independent of mesh resolution, including problems with (interacting) shocks and rarefactions.

97 MATHEMATICS AND COMPUTING↗

GrammarViz 3.0: Interactive Discovery of Variable-Length Time Series Patterns

The problems of recurrent and anomalous pattern discovery in time series, e.g., motifs and discords, respectively, have received a lot of attention from researchers in the past decade. However, since the pattern search space is usually intractable, most existing detection algorithms require that the patterns have discriminative characteristics and have its length known in advance and provided as input, which is an unreasonable requirement for many real-world problems. In addition, patterns of similar structure, but of different lengths may co-exist in a time series. In order to address these issues, we have developed algorithms for variable-length time series pattern discovery that are based on symbolic discretization and grammar inference—two techniques whose combination enables the structured reduction of the search space and discovery of the candidate patterns in linear time. In this work, we present GrammarViz 3.0—a software package that provides implementations of proposed algorithms and graphical user interface for interactive variable-length time series pattern discovery. The current version of the software provides an alternative grammar inference algorithm that improves the time series motif discovery workflow, and introduces an experimental procedure for automated discretization parameter selection that builds upon the minimum cardinality maximum cover principle and aids the time series recurrent and anomalous pattern discovery.

97 MATHEMATICS AND COMPUTING↗

The waiting time problem in a model hominin population

Functional information is normally communicated using specific, context-dependent strings of symbolic characters. This is true within the human realm (texts and computer programs), and also within the biological realm (nucleic acids and proteins). In biology, strings of nucleotides encode much of the information within living cells. How do such information-bearing nucleotide strings arise and become established? This paper uses comprehensive numerical simulation to understand what types of nucleotide strings can realistically be established via the mutation/selection process, given a reasonable timeframe. The program Mendel’s Accountant realistically simulates the mutation/selection process, and was modified so that a starting string of nucleotides could be specified, and a corresponding target string of nucleotides could be specified. We simulated a classic pre-human hominin population of at least 10,000 individuals, with a generation time of 20 years, and with very strong selection (50 % selective elimination). Random point mutations were generated within the starting string. Whenever an instance of the target string arose, all individuals carrying the target string were assigned a specified reproductive advantage. When natural selection had successfully amplified an instance of the target string to the point of fixation, the experiment was halted, and the waiting time statistics were tabulated. Using this methodology we tested the effect of mutation rate, string length, fitness benefit, and population size on waiting time to fixation. Biologically realistic numerical simulations revealed that a population of this type required inordinately long waiting times to establish even the shortest nucleotide strings. To establish a string of two nucleotides required on average 84 million years. To establish a string of five nucleotides required on average 2 billion years. We found that waiting times were reduced by higher mutation rates, stronger fitness benefits, and larger population sizes. However, even using the most generous feasible parameters settings, the waiting time required to establish any specific nucleotide string within this type of population was consistently prohibitive. We show that the waiting time problem is a significant constraint on the macroevolution of the classic hominin population. Routine establishment of specific beneficial strings of two or more nucleotides becomes very problematic.

54 ENVIRONMENTAL SCIENCES↗

Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality

Background: A newly introduced PET/CT scanner (Discovery Meaningful Insights—DMI, GE Healthcare) includes the silicon photomultiplier (SiPM) with timeof-flight (TOF) technology first used in the GE SIGNA PET/MRI. In this study, we investigated the impact of various acquisition times on image quality using this SiPM-based PET/CT. Methods: We reviewed data from 58 participants with cancer who were scanned using the DMI PET/CT scanner. The administered dosages ranged 295.3–429.9 MBq (mean ± SD 356.3 ± 37.4) and imaging started at 71–142 min (mean ± SD 101.41 ± 17. 52) after administration of the radiopharmaceutical. The patients’ BMI ranged 19.79–46. 16 (mean ± SD 26.55 ± 5.53). We retrospectively reconstructed the raw TOF data at 30, 60, 90, and 120 s/bed and at the standard image acquisition time per clinical protocol (180 or 210 s/bed depending on BMI). Each reconstruction was reviewed blindly by two nuclear medicine physicians and scored 1–5 (1—poor, 5—excellent quality). The liver signal-to-noise ratio (SNR) was used as a quantitative measure of image quality. Results: The average scores ± SD of the readers were 2.61 ± 0.83, 3.70 ± 0.92, 4.36 ± 0.82, 4.82 ± 0.39, and 4.91 ± 0.91 for the 30, 60, 90, and 120 s/bed and at standard acquisition time, respectively. Inter-reader agreement on image quality assessment was good, with a weighted kappa of 0.80 (95% CI 0.72–0.81). In the evaluation of the effects of time per bed acquisition on semi-quantitative measurements, we found that the only time point significantly different from the standard time were 30 and 60 s (both with P < 0.001). The effects of dose and BMI were not statistically significant (P = 0.195 and 0.098, respectively). There was a significant positive effect of time on SNR (P < 0.001), as well as a significant negative effect of weight (P < 0.001). Conclusions: Our results suggest that despite significant delays from injection to imaging (due to comparison with standard PET/CT) compared to standard clinical operations and even in a population with average BMI > 25, images can be acquired as fast as 90 s/bed using the SiPM PET/CT and still result in very good image quality (average score > 4).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Femtosecond timing distribution and control for next generation accelerators and light sources

Femtosecond Timing Distribution At LCLS Free-electron-lasers (FEL) have the capability of producing high photon flux from the IR to the hard x-ray wavelength range and to emit femtosecond and eventually even attosecond pulses. This makes them an ideal tool for fundamental as well as applied re-search. Timing precision at the Stanford Linear Coherent Light Source (LCLS) between the x-ray FEL (XFEL) and ultrafast optical lasers is currently no better than 100 fs RMS. Ideally this precision should be much better and could be limited only by the x-ray pulse duration, which can be as short as a few femtoseconds. An increasing variety of science problems involving electron and nuclear dynamics in chemical and material systems will become accessible as the timing improves to a few femtoseconds. Advanced methods of electron beam conditioning or pulse injection could allow the FEL to achieve pulse durations less than one femtosecond. The objective of the work described in this proposal is to set up an optical timing distribution system based on mode locked Erbium doped fiber lasers at LCLS facility to improve the timing precision in the facility and allow time stamping with a 10 fs precision. The primary commercial applications for optical timing distributions systems are seen in the worldwide accelerator facilities and next generation light sources community. It is reasonable to expect that at least three major XFELs will be built in the next decade. In addition there will be up to 10 smaller machines, such as FERMI in Italy and Maxlab in Sweden, plus the market for upgrading already existing facilities like Jefferson Lab. The total market is estimated to be on the order of a 100 Million US Dollars. The company owns the exclusive rights to the IP covering the technology enabling sub-10 fs synchronization systems. Testing this technology, which has set records in a lab environment, at LCLS, hence in a real world scenario, is an important corner stone of bringing the technology to market.

43 PARTICLE ACCELERATORS↗

Time-Gated Raman Spectroscopy (Intern Final Report)

Time-gated Raman spectroscopy is a powerful tool for rapid non-destructive analysis of chemical compounds, particularly when combined with other investigative methods. Time-gating the signal obtained from a sample during Raman spectroscopy allows for the removal of background emission and black body radiation, improving clarity and accuracy of scans. The main objectives of this project were to prove the lab’s time-gated Raman spectroscopy system works as proof of concept and to make select improvements to the in-house LabVIEW software used to run the time-gated system. This time-gated system will be added to the CTK’s TAP reactors in the future, but this is out of the scope of this internship project. This research is important, as understanding the mechanisms behind catalysts leads to designing better systems/materials and the perfection of catalysts, and energy-efficient chemical manufacturing is key when designing a greener future. The research for this project was done with samples at both ambient conditions in sample holders and at operando conditions (i.e., high temperature, unsteady-state) inside a small-volume chemical reactor. Numerous spectro-kinetic scans of the catalysts were obtained, but the advanced dynamics of these systems are still being interpreted. There is data that demonstrates that the time-gated system is correctly rejecting emission from samples, and one can observe real-time changes in the signal from the sample, due to coking or changes induced by redox chemistry. Chemical manufacturers and the planet are the main beneficiaries of catalysis research, as better catalysts will reduce carbon emissions.

36 MATERIALS SCIENCE↗

Visualizations of Travel Time Performance Based on Vehicle Reidentification Data

This paper provides a visual reference of the breadth of arterial performance phenomena based on travel time measures obtained from reidentification technology that has proliferated in the past 5 years. These graphical performance measures are revealed through overlay charts and statistical distribution as revealed through cumulative frequency diagrams (CFDs). With overlays of vehicle travel times from multiple days, dominant traffic patterns over a 24-h period are reinforced and reveal the traffic behavior induced primarily by the operation of traffic control at signalized intersections. A cumulative distribution function in the statistical literature provides a method for comparing traffic patterns from various time frames or locations in a compact visual format that provides intuitive feedback on arterial performance. The CFD may be accumulated hourly, by peak periods, or by time periods specific to signal timing plans that are in effect. Combined, overlay charts and CFDs provide visual tools with which to assess the quality and consistency of traffic movement for various periods throughout the day efficiently, without sacrificing detail, which is a typical byproduct of numeric-based performance measures. These methods are particularly effective for comparing before-and-after median travel times, as well as changes in interquartile range, to assess travel time reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time-resolved Neutron-gamma-ray Data Acquisition for in Situ Subsurface Planetary Geochemistry

The current gamma-ray/neutron instrumentation development effort at NASA Goddard Space Flight Center aims to extend the use of active pulsed neutron interrogation techniques to probe the subsurface elemental composition of planetary bodies in situ. Previous NASA planetary science missions, that used neutron and/or gamma-ray spectroscopy instruments, have relied on neutrons produced from galactic cosmic rays. One of the distinguishing features of this effort is the inclusion of a high intensity 14.1 MeV pulsed neutron generator synchronized with a custom data acquisition system to time each event relative to the pulse. With usually only one opportunity to collect data, it is difficult to set a priori time-gating windows to obtain the best possible results. Acquiring time-tagged, event-by-event data from nuclear induced reactions provides raw data sets containing channel/energy, and event time for each gamma ray or neutron detected. The resulting data set can be plotted as a function of time or energy using optimized analysis windows after the data are acquired. Time windows can now be chosen to produce energy spectra that yield the most statistically significant and accurate elemental composition results that can be derived from the complete data set. The advantages of post-processing gamma-ray time-tagged event-by-event data in experimental tests using our prototype instrument will be demonstrated.

Pulsed neutrongenerator↗

Taxi-Out Time Prediction for Departures at Charlotte Airport Using Machine Learning Techniques

Predicting the taxi-out times of departures accurately is important for improving airport efficiency and takeoff time predictability. In this paper, we attempt to apply machine learning techniques to actual traffic data at Charlotte Douglas International Airport for taxi-out time prediction. To find the key factors affecting aircraft taxi times, surface surveillance data is first analyzed. From this data analysis, several variables, including terminal concourse, spot, runway, departure fix and weight class, are selected for taxi time prediction. Then, various machine learning methods such as linear regression, support vector machines, k-nearest neighbors, random forest, and neural networks model are applied to actual flight data. Different traffic flow and weather conditions at Charlotte airport are also taken into account for more accurate prediction. The taxi-out time prediction results show that linear regression and random forest techniques can provide the most accurate prediction in terms of root-mean-square errors. We also discuss the operational complexity and uncertainties that make it difficult to predict the taxi times accurately.

Safe and efficient surface operations↗

Time-dependent Photoionization Modeling of Warm Absorbers: High-resolution Spectra and Response to Flaring Light Curves

Time-dependent photoionization modeling of warm absorber (WA) outflows in active galactic nuclei can play an important role in understanding the interaction between WAs and the central black hole. The WA may be out of the equilibrium state because of the variable nature of the central continuum. In this paper, with the help of time dependent photoionization modeling, we study how the WA gas properties change with time and how it reacts to changing radiation fields. Incorporating a flaring incident light curve, we investigate the behavior of WAs using a photoionization code that simultaneously and consistently solves the time-dependent equations of level population, heating and cooling, and radiative transfer. We simulate the physical processes in the gas clouds, such as ionization, recombination, heating, cooling, and the transfer of ionizing radiation through the cloud and present high-resolution time-resolved absorption spectra. We demonstrate that time-dependent radiative transfer is important and the calculations that omit this effect quantitatively and systematically underestimate the absorption. Time-dependent photoionization models provide crucial insights into the characteristics of WAs and can be used to constrain their density and spatial distribution.

Astrophysicists↗