Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Norovirus RNA‐dependent RNA polymerase: A computational study of metal‐binding preferences

ABSTRACT Norovirus (NV) RNA‐dependent RNA polymerase (RdRP) is essential for replicating the genome of the virus, which makes this enzyme a key target for the development of antiviral agents against NV gastroenteritis. In this work, a complex of NV RdRP bound to manganese ions and an RNA primer‐template duplex was investigated using X‐ray crystallography and hybrid quantum chemical/molecular mechanical simulations. Experimentally, the complex crystallized in a tetragonal crystal form. The nature of the primer/template duplex binding in the resulting structure indicates that the complex is a closed back‐tracked state of the enzyme, in which the ‐end of the primer occupies the position expected for the post‐incorporated nucleotide before translocation. Computationally, it is found that the complex can accept a range of divalent metal cations without marked distortions in the active site structure. The highest binding energy is for copper, followed closely by manganese and iron, and then by zinc, nickel, and cobalt. Proteins 2017; 85:1435–1445. © 2017 Wiley Periodicals, Inc.

Shaik, Md Munan↗

Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee

Pencil-beam scanning (PBS) proton therapy (PT), particularly intensity modulated PT, represents the latest advanced PT technology for treating cancers, including thoracic malignancies. On the basis of virtual clinical studies, PBS-PT appears to have great potential in its ability to tightly tailor the dose to the target while sparing critical structures, thereby reducing treatment-related toxicities, particularly for tumors in areas with complicated anatomy. However, implementing PBS-PT for moving targets has several additional technical challenges compared with intensity modulated photon radiation therapy or passive scattering PT. Four-dimensional computed tomography–based motion management and robust optimization and evaluation are crucial for minimizing uncertainties associated with beam range and organ motion. Rigorous quality assurance is required to validate dose delivery both before and during the course of treatment. Active motion management (eg, breath hold), beam gating, rescanning, tracking, or adaptive planning may be needed for cases involving significant motion or changes in motion or anatomy over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cathepsin-Mediated Cleavage of Peptides from Peptide Amphiphiles Leads to Enhanced Intracellular Peptide Accumulation

Peptides synthesized in the likeness of their native interaction domain(s) are natural choices to target protein protein interactions (PPIs) due to their fidelity of orthostatic contact points between binding partners. Despite therapeutic promise, intracellular delivery of biofunctional peptides at concentrations necessary for efficacy remains a formidable challenge. Peptide amphiphiles (PAs) provide a facile method of intracellular delivery and stabilization of bioactive peptides. PAs consisting of biofunctional peptide headgroups linked to hydrophobic alkyl lipid-like tails prevent peptide hydrolysis and proteolysis in circulation, and PA monomers are internalized via endocytosis. However, endocytotic sequestration and steric hindrance from the lipid tail are two major mechanisms that limit PA efficacy to target intracellular PPIs. To address these problems, we have constructed a PA platform consisting of cathepsin-B cleavable PAs in which a selective p53-based inhibitory peptide is cleaved from its lipid tail within endosomes, allowing for intracellular peptide accumulation and extracellular recycling of the lipid moiety. We monitor for cleavage and follow individual PA components in real time using a resonance energy transfer (FRET)-based tracking system. Using this platform, components in real time using a Forster we provide a better understanding and quantification of cellular internalization, trafficking, and endosomal cleavage of PAs and of the ultimate fates of each component.

Acar, Handan↗

Dragonstone Strategy – State of Cybersecurity in the Oil & Natural Gas Sector

The oil & natural gas (ONG) system touches every corner of the nation and increased communications & control capabilities have not only allowed for greater efficiency of system operation, but have also created a massive target for adversaries to launch cyber-attacks. Like any other heavy industrial process, the ONG system relies on a complex system of information technology (IT) and operational technology (OT) devices. The current state of cyber-preparedness across the ONG industry varies from organization to organization. Among the most common challenges that ONG companies face are remote locations, longlived field assets, and lacking capabilities to find and track malware on their systems. ONG companies tend to be concerned with lack of cyber-awareness from employees, risk stemming from remote access for operations & maintenance, and software vulnerabilities within third-party equipment. Various industry and government organizations are performing research and development activities to address some of these challenges, but in many cases industry stakeholders are not aware of solutions that already exist. It is clear that a need exists for a coherent, comprehensive, multi-layered strategy for assuring the security and resilience of the nation's pipeline infrastructure against cyber threats. For a variety of reasons, the general consensus from stakeholders interviewed by LLNL is that the state of cyber-security within the electric grid is currently outpacing its ONG cousin. Existing strategies for the resilience and cyber-security of the electric grid can and should be leveraged to provide immediate benefits to the ONG system. In LLNL’s view, there are two key factors currently limiting the development of necessary cyber-practices within the ONG industry: The sheer number of differing regulatory bodies and trade groups offering both standards and best-practice recommendations for ONG cyber-security makes it difficult to create a comprehensive, directed, and coherent strategy that is applicable to all players within the ONG industry. The ONG industry is unaware of potentially useful technologies that have been developed for ensuring cyber-security of other infrastructure systems, such as the electric grid. Leveraging these technologies—and the science and engineering behind them—can provide some low-hanging fruit that can greatly improve cyber-security in the ONG industry without significant investments in terms of time and money. In the months following this report, LLNL will continue to perform outreach to key oil & gas industry stakeholders in a continual effort to identify the most pressing cyber-resilience issues in the industry. This outreach will be supplemented with LLNL’s threat intelligence capabilities to begin painting a clearer picture of the overall threat landscape faced by this sector. This assessment will be threat-informed and while the strategy itself will not be classified we will leverage intelligence analysis and adversary capabilities to identify gaps in current cybersecurity practices for oil & gas pipeline systems. Recommended efforts will be compiled into a cyber-resilience roadmap for the oil & gas pipeline sector, in which LLNL will highlight priority activities to immediately improve the state of cyber-resilience in the industry.

02 PETROLEUM↗

Mariner IX optical navigation using Mars lit limb

Optical spacecraft navigation data, i.e., the lit limb TV image of Mars, acquired during the approach phase of the Mariner IX spacecraft to Mars, has been successfully demonstrated to augment the radio spacecraft tracking data. Accurate in-flight calibration of the TV instrument and the scan platform was performed by referencing stars and planets. Simulated real-time processing and the detailed postflight analyses of the onboard optical data have shown that planet limb data is an important data source in a far-encounter period for which other types of onboard optical measurements, e.g., natural satellite(s) of the target planet with star background, may not be available.

Jerath, N.↗

MicroRNA-223 Enhances Radiation Sensitivity of U87MG Cells In Vitro and In Vivo by Targeting Ataxia Telangiectasia Mutated

Purpose: Ataxia telangiectasia mutated (ATM) protein is important in the DNA damage response because it repairs radiation-induced damage in cancers. We examined the effect of microRNA-223 (miR-223), a regulator of ATM expression, on radiation sensitivity of cancer cells. Methods and Materials: Human embryonic kidney 293 T (293T) cells were infected with pLL3.7-miR-223 plasmid to generate the pLL3.7-miR-223 and -empty virus (EV) lentivirus (miR-223 and EV). A dual luciferase assay in which the reporter contained wild-type 3′ untranslated region (UTR) of ATM was performed. U87MG cells were infected with miR-223 or EV to establish the overexpressed stable cell lines (U87-223 or U87-EV, respectively). Cells were irradiated in vitro, and dose enhancement ratios at 2 Gy (DER{sub 2}) were calculated. Hind legs of BALB/c athymic mice were injected with U87-223 or U87-EV cells; after 2 weeks, half of the tumors were irradiated. Tumor volumes were tracked for a total of 5 weeks. Results: The dual luciferase reporter assay showed a significant reduction in luciferase activity of 293T cells cotransfected with miR-223 and the ATM 3′UTR compared to that in EV control. Overexpression of miR-223 in U87MG cells showed that ATM expression was significantly downregulated in the U87-223 cells compared to that in U87-EV (ATM/β-actin mRNA 1.0 vs 1.5, P<.05). U87-223 cells were hypersensitive to radiation compared to U87-EV cells in vitro (DER{sub 2} = 1.32, P<.01). Mice injected with miR-223-expressing tumors had almost the same tumors after 3 weeks (1.5 cm{sup 3} vs 1.7 cm{sup 3}). However, irradiation significantly decreased tumor size in miR-223-expressing tumors compared to those in controls (0.033 cm{sup 3} vs 0.829 cm{sup 3}). Conclusions: miR-223 overexpression downregulates ATM expression and sensitizes U87 cells to radiation in vitro and in vivo. MicroRNA-223 may be a novel cancer-targeting therapy, although its cancer- and patient-specific roles are currently undefined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bioscience COVID Rapid Response Report

The COVID-19 disease outbreak and its impact on global health and economies have highlighted the national security threat posed by pathogens with pandemic potential and the need for rapid development of effective diagnostics and medical countermeasures. The Bioscience IA selected for funding rapid COVID LDRD project proposals that addressed critical R&D gaps in pandemic response that could be accomplished in 1-3 months with the requested funding. In total, the Bioscience IA funded nine rapid projects that addressed 1) rapid and accurate methods for SARS-CoV-2 RNA detection, 2) modeling tools to help prioritize populations for diagnostic testing, 3) bioinformatic tools to track SARS-CoV-2 genomic sequence changes over time, 4) molecular inhibitors of SARS-CoV-2 cellular infection, and 5) method for rapid staging of COVID19 disease to enable administration of more effective treatments. In addition, LDRD funded one larger project to be completed in FY21 that leverages Sandia capabilities to address the need for platform diagnostics and therapeutics that can be rapidly tailored against emerging pathogen targets.

59 BASIC BIOLOGICAL SCIENCES↗

On-Orbit Performance and Calibration Improvements For the Reflective Solar Bands of Terra and Aqua MODIS

Moderate Resolution Imaging Spectroradiometer (MODIS) is the keystone instrument for NASAs EOS Terra and Aqua missions, designed to extend and improve heritage sensor measurements and data records of the land, oceans and atmosphere. The reflective solar bands (RSB) of MODIS covering wavelengths from 0.41 micrometers to 2.2 micrometers, are calibrated on-orbit using a solar diffuser (SD), with its on-orbit bi-directional reflectance factor (BRF) changes tracked using a solar diffuser stability monitor (SDSM). MODIS is a scanning radiometer using a two-sided paddle-wheel mirror to collect earth view (EV) data over a range of (+/-)55 deg. off instrument nadir. In addition to the solar calibration provided by the SD and SDSM system, lunar observations at nearly constant phase angles are regularly scheduled to monitor the RSB calibration stability. For both Terra and Aqua MODIS, the SD and lunar observations are used together to track the on-orbit changes of RSB response versus scan angle (RVS) as the SD and SV port are viewed at different angles of incidence (AOI) on the scan mirror. The MODIS Level 1B (L1B) Collection 6 (C6) algorithm incorporated several enhancements over its predecessor Collection 5 (C5) algorithm. A notable improvement was the use of the earth-view (EV) response trends from pseudo-invariant desert targets to characterize the on-orbit RVS for select RSB (Terra bands 1-4, 8, 9 and Aqua bands 8, 9) and the time, AOI, and wavelength-dependent uncertainty. The MODIS Characterization Support Team (MCST) has been maintaining and enhancing the C6 algorithm since its first update in November, 2011 for Aqua MODIS, and February, 2012 for Terra MODIS. Several calibration improvements have been incorporated that include extending the EV-based RVS approach to other RSB, additional correction for SD degradation at SWIR wavelengths, and alternative approaches for on-orbit RVS characterization. In addition to the on-orbit performance of the MODIS RSB, this paper also discusses in detail the recent calibration improvements implemented in the MODIS L1B C6.

Angal, Amit↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Real-time tracking of structural evolution in 2D MXenes using theory-enhanced machine learning

In situ Electron Energy Loss Spectroscopy (EELS) combined with Transmission Electron Microscopy (TEM) has traditionally been pivotal for understanding how material processing choices affect local structure and composition. However, the ability to monitor and respond to ultrafast transient changes, now achievable with EELS and TEM, necessitates innovative analytical frameworks. Here, we introduce a machine learning (ML) framework tailored for the real-time assessment and characterization of in operando EELS Spectrum Images (EELS-SI). We focus on 2D MXenes as the sample material system, specifically targeting the understanding and control of their atomic-scale structural transformations that critically influence their electronic and optical properties. This approach requires fewer labeled training data points than typical deep learning classification methods. By integrating computationally generated structures of MXenes and experimental datasets into a unified latent space using Variational Autoencoders (VAE) in a unique training method, our framework accurately predicts structural evolutions at latencies pertinent to closed-loop processing within the TEM. This study presents a critical advancement in enabling automated, on-the-fly synthesis and characterization, significantly enhancing capabilities for materials discovery and the precision engineering of functional materials at the atomic scale.

47 OTHER INSTRUMENTATION↗

Coherent fragmentation of {sup 12}C nuclei of momentum 4.5 GeV/c per nucleon through the {sup 8}Be{sub g.s.}+{sup 4}He channel in a nuclear photoemulsion containing lead nuclei

A two-particle channel in which an unbound nucleus of {sup 8}Be in the ground state ({sup 8}Be{sub g.s.}) was one of the fragments was selected among events where {sup 12}C nuclei of momentum 4.5 GeV/c per nucleon undergo coherent dissociation into three alpha particles. The events in question were detected in a track nuclear photoemulsion containing lead nuclei, which was irradiated at the synchrophasotron of the Laboratory of High Energies at the Joint Institute for Nuclear Research (JINR, Dubna). The average transverse momentum of alpha particles produced upon the decay of {sup 8}Be{sub g.s.} nuclei was 87±6 MeV/c, while that for “single” alpha (α{sub s}) particles was 123±15 MeV/c. The average value of the transverse-momentum transfer in the reaction being considered, Pt(12C), was 223 ± 20 MeV/c. The average value of the cross section for this channel involving Ag and Br target nuclei was 13 ± 4 mb, while the cross section for the reaction on the Pb nucleus was 40 ± 15 mb. The Coulomb dissociation contribution evaluated on the basis of the number of events where the momentum P{sub t}({sup 12}C) did not exceed 0.1 GeV/c saturated about 20%. In nine events, the measured total transverse energy of the fragments in the reference frame comoving with the decaying carbon nucleus did not exceed 0.45 MeV, which did not contradict the excitation of the participant {sup 12}C nucleus to the level at 7.65 MeV. The average value of the transverse momentum in those events was 234 ± 25 MeV/c.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ground Simulator Studies of a Nonlinear Linkage in a Power Control System

An investigation was made to determine the characteristics of a nonlinear linkage installed in a power control system incorporated in a ground simulator. The nonlinear linkage provided for increased control-stick motion for relatively small simulator response at control motions near neutral. The quality of the control system was rated on the ease and precision with which various tracking tasks were performed by the pilots who operated the simulator. The results obtained with the nonlinear linkage installed in the control system were compared with those obtained by using the normal linear control system. Several combinations of nonlinearity of the linkage were tested for various dynamic characteristics of the simulator. It was found that the pilots were able to track almost as well with the nonlinear linkage installed as with the normal system. All of the pilots were of the opinion, however, that the nonlinearity was an undesirable feature in the control system because of the apparent lack of simulator response through the neutral range of the linkage where relatively large stick deflections could be made with very little simulator motion. The results showed that increased lag between the target and chair position, higher stick-force levels, and uneven stick forces due to the dynamics of the linkage were general characteristics of all the nonlinear linkage conditions tested. It was also found that for cases of low simulator damping, rapid control motions caused considerably higher overshoots when the nonlinear linkage was installed than were obtained for the normal linear control system. These characteristics were considered to be sufficiently undesirable to out-weigh the advantages to be gained from the use of a nonlinear linkage in the control system of an airplane.

Assadourian, Arthur↗

GERMcode: A Stochastic Model for Space Radiation Risk Assessment

A new computer model, the GCR Event-based Risk Model code (GERMcode), was developed to describe biophysical events from high-energy protons and high charge and energy (HZE) particles that have been studied at the NASA Space Radiation Laboratory (NSRL) for the purpose of simulating space radiation biological effects. In the GERMcode, the biophysical description of the passage of HZE particles in tissue and shielding materials is made with a stochastic approach that includes both particle track structure and nuclear interactions. The GERMcode accounts for the major nuclear interaction processes of importance for describing heavy ion beams, including nuclear fragmentation, elastic scattering, and knockout-cascade processes by using the quantum multiple scattering fragmentation (QMSFRG) model. The QMSFRG model has been shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections. For NSRL applications, the GERMcode evaluates a set of biophysical properties, such as the Poisson distribution of particles or delta-ray hits for a given cellular area and particle dose, the radial dose on tissue, and the frequency distribution of energy deposition in a DNA volume. By utilizing the ProE/Fishbowl ray-tracing analysis, the GERMcode will be used as a bi-directional radiation transport model for future spacecraft shielding analysis in support of Mars mission risk assessments. Recent radiobiological experiments suggest the need for new approaches to risk assessment that include time-dependent biological events due to the signaling times for activation and relaxation of biological processes in cells and tissue. Thus, the tracking of the temporal and spatial distribution of events in tissue is a major goal of the GERMcode in support of the simulation of biological processes important in GCR risk assessments. In order to validate our approach, basic radiobiological responses such as cell survival curves, mutation, chromosomal aberrations, and representative mouse tumor induction curves are implemented into the GERMcode. Extension of these descriptions to other endpoints related to non-targeted effects and biochemical pathway responses will be discussed.

Kim, Myung-Hee Y.↗

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology): Enabling Technology for Missions to the Venus Clouds

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) is an early-stage technology allowing a single aeroshell body to act as both an entry vehicle and aerosol-sampling passive descent sonde. AERACEPT does not require heat shield separation, deployable parachutes, or descent control, thus reducing the mass, volume, and complexity of planetary aerosol sampling. AERACEPT is particularly well suited for a Venus mission, where the particles of greatest interest are within the subsonic descent regime. AERACEPT uses the aeroshell’s own velocity to drive aerosol capture and separation through a series of embedded inlets. It takes advantage of recently developed thermal protection materials (3D-CC and HEEET) in combination with heritage aerosol sampling technologies from both planetary and airborne science (high-speed inlets and particle separation). The trade space for a given descent trajectory includes the particle capture efficiency for a given size, the bias introduced in the sampled particle size and concentration distributions, and the thermal alteration experienced by the particles during their brief exposure to the internal flow environment. AERACEPT is included in the Nephele mission concept study for a small spacecraft targeting the Venus middle and lower cloud layers. Nephele complements larger missions targeting Venus atmospheric gas analysis, such as DAVINCI and Venera-D, by specifically targeting cloud and haze particles. Because of the short lifetime of the probe in the lower atmosphere, Nephele requires a fast cadence of analysis of the captured particles, and includes the VOLTR dual optical spectrometer (SERS/LIBS) as part of its notional payload. Preliminary modeling based on the Nephele trajectory at 63 km to 39 km indicates AERACEPT can limit sample heating to 30-60 K above ambient. A modified particle tracking model has been implemented to estimate capture efficiency of particles larger than 0.1 µm and total sample volume as part of an inlet and interal flow path geometry trade study. Further modeling and empirical testing is underway to improve these estimates.

AERACEPT↗

nuSTORM Pion Beamline Design Update

A facility producing neutrinos from muons that decay in a racetrack ring can provide extremely well understood neutrino beams for oscillation physics and the search for sterile neutrinos. The “neutrinos from STORed Muons” (nuSTORM) facility based on this idea has been introduced by Bross, Neuffer et al. The design of the nuSTORM facility and the particle tracking have been presented in the paper of Liu, et al. This paper demonstrates the recent optimization results of the pion beamline, with G4beamline simulations. The optimum choice of pion beam center momentum, a new algorithm on fitting bivariate Gaussian distribution to the pion phase space data at the downstream side of the horn, and the comparison of the beamline performance with the optics designed based on Graphite and Inconel targets are also described.

43 PARTICLE ACCELERATORS↗

WIPP Certification of the Retrieval Box Assay System at the Advanced Mixed Waste Treatment Plant, Idaho - 16241

The Retrieval Box Assay System (RBAS) at the Advanced Mixed Waste Treatment Plant (AMWTP) is an Imaging Passive Active Neutron system supplemented with a High Purity Germanium (HPGe) gamma system for the quantification of Pu-239 Fissile Gram Equivalent (FGE) and transuranic (TRU) alpha activity of waste containers of various sizes up to 249 cm x 149 cm x 198 cm (Length x Width x Height). The system was originally calibrated in 2002 (with a range of surrogate matrices and radioactive sources in a 213 cm x 122 cm x 122 cm FRP box) and has been operational for over a decade. As of August 2015, the RBAS has measured approximately 18,000 boxes (50,000 m3 of waste) which has subsequently been fed into the facility's treatment process. Its success, and the wide envelope of waste that it can characterize, has led AMWTP to extend the RBAS mission to include WIPP certification. As part of this new project, the instrument must be capable of meeting WIPP's Waste Acceptance Criteria (WAC) which include reporting activities and masses of the 10 WIPP-tracked radionuclides. The system will be required to assay sludge and debris waste streams, shredded waste and large metal items. The container size includes Standard Waste Box (SWBs), Fiberglass Reinforced Plywood (FRPs) and large Shredder Boxes. Sludge matrices will be loaded into 210-liter (55-gallon) drums and placed inside an SWB. After assay, boxes will be over-packed into SLB-II's for shipment to WIPP. The target waste streams will contain mixtures of Weapons Grade plutonium, Heat Source plutonium (high in Pu-238 content) and Mixed Oxide (MOX). The activity of the waste is expected to encompass a wide dynamic range of activity from low-level waste (LLW) to TRU with up to several hundred grams of plutonium. Some packages will have high gamma activity associated with fission and activation products such as Cs-137 and Co-60. The existing RBAS hardware (detectors, electronics, assay chamber etc.) was retained for this project. Two lead filters were provided and installed on the existing filter wheels to attenuate the gamma ray flux from the highest activity boxes to avoid overload of the HPGe detectors. The new software suite includes PC-FRAM (Version 5), which is used for the isotopic analysis of the gamma spectra. Integration of FRAM and neutron results is performed using a software package known as RBAS WIPP Analysis Reporting Software (RWARS). This package also performs matrix dependent background adjustments. Other upgrades provided include automated tests that identify when assay parameters fall outside a predetermined range and a new Quality Checking (QC) application. Minimum Detectable Activity (MDA) values were determined for the active and passive neutron modes as a function of measured matrix correction indices. The resulting Minimum Detectable Concentration (MDC) has been demonstrated to be less than 3700 Bq/g alpha activity (100 nCi/g). Modifications were performed to update the system TMU parameters to accommodate assay of non-standard size boxes and a wider range of matrix materials. A series of calibration confirmation, measurements were performed on site in 2014 using a representative range of surrogate boxes and radioactive sources including Pu. The WIPP WAC performance criteria were successfully demonstrated up to 157 g Pu and the system passed its first Performance Demonstration Program (PDP) cycle in the Spring of 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated characterization of perceptual quality of clinical chest radiographs: Validation and calibration to observer preference

Purpose: The authors previously proposed an image-based technique [Y. Lin et al. Med. Phys. 39, 7019–7031 (2012)] to assess the perceptual quality of clinical chest radiographs. In this study, an observer study was designed and conducted to validate the output of the program against rankings by expert radiologists and to establish the ranges of the output values that reflect the acceptable image appearance so the program output can be used for image quality optimization and tracking. Methods: Using an IRB-approved protocol, 2500 clinical chest radiographs (PA/AP) were collected from our clinical operation. The images were processed through our perceptual quality assessment program to measure their appearance in terms of ten metrics of perceptual image quality: lung gray level, lung detail, lung noise, rib–lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm–lung contrast, and subdiaphragm area. From the results, for each targeted appearance attribute/metric, 18 images were selected such that the images presented a relatively constant appearance with respect to all metrics except the targeted one. The images were then incorporated into a graphical user interface, which displayed them into three panels of six in a random order. Using a DICOM calibrated diagnostic display workstation and under low ambient lighting conditions, each of five participating attending chest radiologists was tasked to spatially order the images based only on the targeted appearance attribute regardless of the other qualities. Once ordered, the observer also indicated the range of image appearances that he/she considered clinically acceptable. The observer data were analyzed in terms of the correlations between the observer and algorithmic rankings and interobserver variability. An observer-averaged acceptable image appearance was also statistically derived for each quality attribute based on the collected individual acceptable ranges. Results: The observer study indicated that, for each image quality attribute, the averaged observer ranking strongly correlated with the algorithmic ranking (linear correlation coefficient R > 0.92), with highest correlation (R = 1) for lung gray level and the lowest (R = 0.92) for mediastinum noise. There was a strong concordance between the observers in terms of their rankings (i.e., Kendall’s tau agreement > 0.84). The observers also generally indicated similar tolerance and preference levels in terms of acceptable ranges, as 85% of the values were close to the overall tolerance or preference levels and the differences were smaller than 0.15. Conclusions: The observer study indicates that the previously proposed technique provides a robust reflection of the perceptual image quality in clinical images. The results established the range of algorithmic outputs for each metric that can be used to quantitatively assess and qualify the appearance quality of clinical chest radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vision-based guidance for an automated roving vehicle

A controller designed to guide an automated vehicle to a specified target without external intervention is described. The intended application is to the requirements of planetary exploration, where substantial autonomy is required because of the prohibitive time lags associated with closed-loop ground control. The guidance algorithm consists of a set of piecewise-linear control laws for velocity and steering commands, and is executable in real time with fixed-point arithmetic. The use of a previously-reported object tracking algorithm for the vision system to provide position feedback data is described. Test results of the control system on a breadboard rover at the Jet Propulsion Laboratory are included.

Griffin, M. D.↗