Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

A scanning drift tube apparatus for spatiotemporal mapping of electron swarms

A “scanning” drift tube apparatus, capable of mapping of the spatiotemporal evolution of electron swarms, developing between two plane electrodes under the effect of a homogeneous electric field, is presented. The electron swarms are initiated by photoelectron pulses and the temporal distributions of the electron flux are recorded while the electrode gap length (at a fixed electric field strength) is varied. Operation of the system is tested and verified with argon gas; the measured data are used for the evaluation of the electron bulk drift velocity. The experimental results for the space-time maps of the electron swarms — presented here for the first time — also allow clear observation of deviations from hydrodynamic transport. The swarm maps are also reproduced by particle simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron beam moiré fringes imaging by image converter tube with a magnetic lens

An image converter tube with a magnetic lens was used to obtain static images of moiré fringes formed by electron beam. These moiré fringes are formed due to the interference between the anode mesh and the photocathode containing slits of various spatial frequencies. Moiré fringes are observed at an accelerating voltage of 3.5 kV requiring the magnetic excitation condition of ∼550 ampere-turns. Not only the features of the fringes are analyzed but also the change of fringe spacing as a function of the rotation angle is investigated. The experimental results are found well in agreement with the theoretical analysis. By changing the rotation angle or adjusting the excitation condition of the magnetic lens, we were able to record parallel moiré and secondary moiré fringes too. The secondary moiré fringes can be observed in the rotation angle range of −39.5° to −50.6°. The theoretical analysis indicates that the secondary moiré is formed by the interference between the photocathode slits and the 2-D periodic structure of the anode mesh. Combining our proposed moiré method with the pulse-dilation technique may potentially open the door for future applications, in various fields including, but not limited to, ultrafast electrical pulse diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4} for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAUSAGE WAVES IN TRANSVERSELY NONUNIFORM MONOLITHIC CORONAL TUBES

We investigate fast sausage waves in a monolithic coronal magnetic tube, modeled as a local density inhomogeneity with a continuous radial profile. This work is a natural extension of our previous results, obtained for a slab loop model for the case of cylindrical geometry. Using Kneser’s oscillating theorem, we provided the criteria for the existence of trapped and leaky wave regimes as a function of the profile features. For a number of density profiles there are only trapped modes for the entire range of longitudinal wave numbers. The phase speed of these modes tends toward the external Alfvén speed in the long wavelength limit. The generalized results were supported by the analytic solution of the wave equation for the specific density profiles. The approximate Wentzel–Kramers–Brillouin solutions allowed us to obtain the desired dispersion relations and to study their properties as a function of the profile parameters. The multicomponent quasi-periodic pulsations in flaring loops, observed on 2001 May 2 and 2002 July 3, are interpreted in terms of the transversely fundamental trapped fast sausage mode with several longitudinal harmonics in a smooth coronal waveguide.

79 ASTRONOMY AND ASTROPHYSICS↗

Standing sausage modes in nonuniform magnetic tubes: An inversion scheme for inferring flare loop parameters

Standing sausage modes in flare loops are important for interpreting quasi-periodic pulsations (QPPs) in solar flare light curves. We propose an inversion scheme that consistently uses their periods P and damping times τ to diagnose flare loop parameters. We derive a generic dispersion relation governing linear sausage waves in pressure-less straight tubes, for which the transverse density inhomogeneity takes place in a layer of arbitrary width l and is of arbitrary form. We find that P and τ depend on the combination of [R/v{sub Ai},L/R,l/R,ρ{sub i}/ρ{sub e}], where R is the loop radius, L is the looplength, v{sub Ai} is the internal Alfvén speed, and ρ{sub i}/ρ{sub e} is the density contrast. For all the density profiles examined, P and τ experience saturation when L/R ≫ 1, yielding an inversion curve in the [R/v{sub Ai},l/R,ρ{sub i}/ρ{sub e}] space with a specific density profile when L/R is sufficiently large. When applied to a spatially unresolved QPP event, the scheme yields that R/v{sub Ai} is the best constrained, whereas l/R corresponds to the other extreme. For spatially resolved QPPs, while L/R ≫ 1 cannot be assumed beforehand, an inversion curve remains possible due to additional geometrical constraints. When a spatially resolved QPP event involves another mode, as is the case for a recent event, the full set of [v{sub Ai},l,ρ{sub i}/ρ{sub e}] can be inferred. We conclude that the proposed scheme provides a useful tool for magneto-seismologically exploiting QPPs.

79 ASTRONOMY AND ASTROPHYSICS↗

Preparatory Study of Photomultiplier Tubes of 10-inch and 3-inch Diameter for KM3NeT Underwater Neutrino Telescope

Large area photomultipliers are widely used in neutrino and astro-particle detectors to measure Cherenkov light in media like water or ice. The key element of these detectors are the so-called 'optical module', which consists of a photodetector enclosed in a transparent pressure-resistant container to protect it and ensure good light transmission. KM3NeT collaboration aims to construct an underwater 'hybrid' neutrino telescope by using two models detection unit. The 'tower' detection unit will be composed of large area 10-inch photomultipliers tube enclosed into 13-inch glass vessel sphere. In the 'string' detection unit instead, the light detector will be the 'digital optical module' (DOM) a glass vessel of 17-inch with 31 photomultipliers of 3- inch diameter looking upwards and downwards. The choice of two different kinds of photomultipliers, obliges us to investigate their main characteristics. Noise pulses at the anode of each photomultiplier strongly affect the performance of the detector. A large study was conducted on noise pulses of large area photomultipliers, considering time and charge distributions of dark pulses, pre-pulses, delayed pulses, and after-pulses. The contribution to noise pulses due to the presence of the external glass vessels was also studied. Moreover the presence of the Earth's magnetic field should modify quantities like gain and transit time spread in photomultipliers and we will deeply investigate on this. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Efficiency Inductive Output Tubes Using a Third Harmonic Drive on the Grid

In this article, we discuss the use of a third harmonic component to the drive voltage on the grid of an inductive output tube (IOT). High-efficiency IOTs are typically characterized by efficiencies up to 70%–75%. However, the achievement of efficiencies greater than 80% would substantially reduce the operating costs of next-generation accelerators. In order to achieve this goal, we consider the addition of a third harmonic component to the drive signal on the grid of an IOT. The use of a third harmonic drive component in IOT guns has been considered in order to apply such a gun as the injector of radio frequency linear accelerators (RF linacs). Furthermore, we consider that the IOT will be used to provide the rf power to drive RF linacs and apply the third harmonic with the intention of increasing the efficiency of the RF output of the IOT. We consider a model IOT with a 700-MHz resonant cavity and using an annular beam with a voltage of 30 kV, an average current of 6.67 A yielding a perveance of about 1.3 μP. We simulate this IOT using the NEMESIS simulation code which has been successfully validated by comparison with the K5H90W-2 IOT developed by Communications and Power Industries. It is found that the effect of the third harmonic on the efficiency is greatest when the phase of the third harmonic is shifted by radians with respect to the fundamental drive signal and with third harmonic powers greater than about 50% that of the fundamental drive power. For the present example, we show that efficiencies approaching 86% are possible by this means.

43 PARTICLE ACCELERATORS↗

Mechanical properties of photomultiplier tube glasses for neutrino detection

Photomultiplier tubes (PMT) are one of the primary components of water Cherenkov neutrino detection for the Long Baseline Neutrino Experiment (LBNE). Thousands of 10- to 12-inch diameter PMT bulbs are placed in the inner wall of a detection tank or a reservoir (e.g., deep mine) filled with 10,000 gallons of high purity water with a resistivity of 11–18.24 MΩ-cm. Long-term service of PMTs is vital to the success of neutrino detection projects. We report our results of our investigation on mechanical properties of PMT glasses from two vendors and the effect of ion exchange on their mechanical strength. Vickers indentation, four-point bend test, and ring-on-ring biaxial flexural strength test were used for evaluation of the mechanical strength. Chemical (potassium–sodium ion exchange) strengthening results show increased strength of 46% in one vendor glass and a 57% increase in the other, with no significant reduction in optical transmission in the ultraviolet-visible range of the electromagnetic spectrum that is critical to neutrino detection. Finally, our results also show narrowing of the distribution of strength calculated using Weibull statistics with chemical strengthening for comparable exchange depths of 22–28 μm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-interface Richtmyer-Meshkov turbulent mixing at the Los Alamos Vertical Shock Tube

We studied Mach number and initial conditions effects on Richtmyer–Meshkov (RM) mixing by the vertical shock tube (VST) at Los Alamos National Laboratory (LANL). At the VST, a perturbed stable light-to-heavy (air–SF 6 , A=0.64) interface is impulsively accelerated with a shock wave to induce RM mixing. We investigate changes to both large and small scales of mixing caused by changing the incident Mach number (Ma=1.3 and 1.45) and the three-dimensional (3D) perturbations on the interface. Simultaneous density (quantitative planar laser-induced fluorescence (PLIF)) and velocity (particle image velocimetry (PIV)) measurements are used to characterize preshock initial conditions and the dynamic shocked interface. Initial conditions and fluid properties are characterized before shock. Using two types of dynamic measurements, time series (N=5 realizations at ten locations) and statistics (N=100 realizations at a single location) of the density and velocity fields, we calculate several mixing quantities. Mix width, density-specific volume correlations, density–vorticity correlations, vorticity, enstrophy, strain, and instantaneous dissipation rate are examined at one downstream location. Results indicate that large-scale mixing, such as the mix width, is strongly dependent on Mach number, whereas small scales are strongly influenced by initial conditions. Lastly, the enstrophy and strain show focused mixing activity in the spike regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the x-ray tube anodes' surface profile and its effects on the x-ray spectra

An experimental study--involving measurements with an optical microscope, a profilometer, and a scanning electron microscope--for determination of the surface profile of x-ray tube anodes is presented. The islands on the ''mud-flatting'' surface are separated by approximately 8 {mu}m deep cracks. The surface roughness on the island is typically below 1 {mu}m, and the area ratio of cracks to the total surface is higher on the more extensively used regions (anode aging). A simple model was proposed to calculate the spectrum modification introduced by the rough surface. Loss of x-ray intensity of 4% was predicted using the roughest surface at a small emission angle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of reconstruction methods and x-ray tube current–time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study

Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR{sup 3D}) and filtered back projection (FBP) over a range of tube current–time product (mAs). Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and +100, −630, and −800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant. Images were reconstructed with both AIDR{sup 3D} and FBP. For the observer study, 34 normal cases (no nodules) and 34 abnormal cases (containing 1–3 nodules, mean 1.35 ± 0.54) were chosen. Eleven observers evaluated images from all mAs and reconstruction methods under the free-response paradigm. A crossed-modality jackknife alternative free-response operating characteristic (JAFROC) analysis method was developed for data analysis, averaging data over the two factors influencing nodule detection in this study: mAs and image reconstruction (AIDR{sup 3D} or FBP). A Bonferroni correction was applied and the threshold for declaring significance was set at 0.025 to maintain the overall probability of Type I error at α = 0.05. Contrast-to-noise (CNR) was also measured for all nodules and evaluated by a linear least squares analysis. Results: For random-reader fixed-case crossed-modality JAFROC analysis, there was no significant difference in nodule detection between AIDR{sup 3D} and FBP when data were averaged over mAs [F(1, 10) = 0.08, p = 0.789]. However, when data were averaged over reconstruction methods, a significant difference was seen between multiple pairs of mAs settings [F(3, 30) = 15.96, p < 0.001]. Measurements of effective dose and effective risk showed the expected linear dependence on mAs. Nodule CNR was statistically higher for simulated nodules on images reconstructed with AIDR{sup 3D} (p < 0.001). Conclusions: No significant difference in nodule detection performance was demonstrated between images reconstructed with FBP and AIDR{sup 3D}. mAs was found to influence nodule detection, though further work is required for dose optimization.

60 APPLIED LIFE SCIENCES↗

Quantum conductance of achiral graphene ribbons and carbon tubes

Explicit expressions of the band spectrum near the neutrality point are derived for armchair and zigzag graphene ribbons and carbon tubes. Several spectral features, which were previously observed only in numerical calculations, are given an adequate analytic description in terms of elementary functions. The obtained dispersion relations are used for a comparison of conductance ladders of graphene-based wires; these relations are also beneficial for many other applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First samples of Ti and Nb tubes explosion welding joint with stainless steel for ILC 1.8 K cryomodule

The world first samples of Ti and Nb tubes joint with stainless steel ones by an explosion welding by the JINR-VNIIEF-FNAL-INFN cooperation were manufactured in the frame of ILC R&D programe. An applying methods of relaxation of residual tensions (after explosion and electron beam welding), macro- and microanalyses of welding seam and cryogenic tests of the samples produced manifest the achievement of high mechanic strength (≈250 MPa/share) of welding seam, solidity and leak absence on 10{sup −10} l atm/s level at 1.8 K. The explosion welding technology and methods introducing to industrial manufacturing of the 4-th generation of cryomodule of TESLA TYPE DESIGN can exclude the Ti—communications, connect the Nb—cavity with stainless steel vessel and reduce significantly the accelerator cost.

43 PARTICLE ACCELERATORS↗

Generation of a Periodic Sequence of High-Power Ultrashort Pulses in a Chain of Coupled Backward-Wave and Traveling-Wave Tubes Operating in the Regimes of Amplification and Nonlinear Kompfner Suppression

We have studied the dynamics of an electronic microwave generator with backward-wave and traveling-wave tubes connected in the feedback circuit and operating in the regimes of amplification and nonlinear Kompfner absorption, respectively. It is shown that radiation generated in such a system can have the form of a periodic sequence of ultrashort pulses. The studied mechanism of pulse generation is analogous to the method of passive mode locking, which is widely used in laser physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transparent Traveling-Wave Tubes with Multivelocity Electron Beams

We present results of a theoretical and experimental investigation of the output characteristics of transparent (containing no local absorbers) traveling-wave tubes (TWTs) operating on multivelocity (turbulent) electron beams. It is established that higher gain (up to 20 dB) and higher efficiency (40–50%) can be achieved in this case in comparison to the output characteristics of transparent TWTs employing monovelocity (laminar) electron beams. This effect is explained by the formation of space-charge bunches of much higher density in multivelocity electron beams than in monovelocity beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Subterahertz Multiplier Based on a Traveling Wave Tube with a Sheet Electron Beam

In this paper, we present the results of the study of a multiplier based on a traveling wave tube with a sheet electron beam and slow-wave double-grating structures. Device configurations with the possibility of obtaining an output power above 60 W at the second harmonic frequency of 190 GHz with an input power of about 10 W at the first harmonic frequency were determined.

43 PARTICLE ACCELERATORS↗