Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that reflects most of the Sun’s energy, yet still provides far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would benefit deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. However, perhaps the most significant enablement achieved from such a coating would be the long-term, deep space storage of cryogenic liquids, such as liquid oxygen (LOX). In our Phase I NIAC study, we realized that a combination of scattering particles and a silver backing could yield a highly effective, very broadband, reflector that could potentially reflect more than 99.9% of the Sun’s irradiant power. We developed a sophisticated model of this reflector and theoretically showed that cryogenic temperatures could be achieved in deep space at one astronomical unit (1 AU) from the Sun. We showed how this new reflector could minimize heat conduction into the cryogenic tanks by coating the tank support struts. We then modelled a strawman architecture for a mission to Mars, using a coated LOX tank, coated struts, and infrared shields, to show that with our new coating it would be possible to maintain liquid oxygen passively. As a result of this work a patent application was generated and a paper published in Optics Letters. Our Phase II NIAC study had two primary goals, to develop a rigid version of the cryogenic selective surface proposed in Phase I and to test its performance in a simulated deep space environment. During the first year of the project the work concentrated on developing rigid tiles of BaF2, leading to tiles as large as 4 inches in diameter that transmitted very little visible light. In addition, during the first year a simulated deep space environment was created using a vacuum chamber and cryocooler. Using this facility, we showed that our BaF2 tiles absorbed less than ¼% of 375 nm radiation, a significant milestone for the work. During the second year of the project, we continued to develop the BaF2 tiles and we put significant effort into the construction of a deep space environment where we could project simulated solar radiation onto a sample. In the spring of 2018, we conducted our first solar simulator test with BaF2 and saw about 3.6% absorption. This is better than the state-of-the-art, but disappointing since predictions were for much lower absorption. We, erroneously, attributed this absorption to water retention by the BaF2, and decided to change materials. We considered several oxides and settled on yttrium oxide (Y2O3) for further development, because it is broadband, lightweight, has high index, and is hydrophobic. In July 2018 we conducted our first test of a rigid tile of Y2O3 in the simulated deep space environment and saw significant absorption again. We then realized that the issue was not water, but mid-wave radiation passing through the tile and being absorbed by the temperature sensor and the varnish used to hold it in place. We wrapped the sensor in silver foil, re-ran the test, and saw much lower absorption; only 1.1%. We then re-ran the BaF2 tile and saw 1.4% absorption. These values are almost adequate to maintain LOX in deep space, but we suspect that there are still issues in our test apparatus; we suspect thermocouple wires may be absorbing radiation. Further, post-NIAC, testing will better determine the performance of our new solar reflector. In order to restrict the size of this report, we will only briefly describe topics that we have previously published, allowing us to devote more time to new material. So minimal material will be devoted to modeling the material and deep space cryogenic storage, while longer sections will cover our material development, simulated deep space testing, and new applications. The Launch Service Program (LSP) requested that we explore ways to use this new coating to maintain LOX in low Earth Orbit and that work is described. In addition, the Nuclear Thermal Propulsion (NTP) Program asked us to explore ways to reduce the heat load for liquid hydrogen, resulting in the development of a spray-on version of the coating that should significantly improve in-space multi-layer insulation performance.

Robert C. Youngquist,↗

A Simple Transient Thermal Test Assembly for Insulation Materials

A simple transient thermal test was developed for evaluating the thermal performance of high-temperature flexible insulation materials in atmospheric pressure air. The test setup was inspired by the test assembly used for evaluating the performance of fire shelters and fire protective clothing. The heating source used was a burner supplied with propane gas that can generate relatively uniform heating over a wide area. The ratio of the in-plane width to thickness of the insulation test sample in the test assembly was selected to be greater than ten so that the heat transfer in the center of the test assembly was nearly one-dimensional. A rigid, thin Inconel plate was used as the septum plate directly exposed to the flame to provide a relatively uniform, known-temperature boundary condition for the test assembly, and to prevent convective heat transfer through the test insulation from the burner. The test sample, flexible alumina paper insulation, was placed between the Inconel plate and a thin titanium witness plate. The overall assembly was further insulated using a combination of rigid and flexible ceramic insulations to minimize heat losses from the periphery of the test assembly. Thermocouples installed on the septum and witness plates and inside the insulation test sample provided temperature measurements at various locations. For the evaluation tests, the Inconel septum plate reached temperatures between 780°C and 850°C for tests with flame exposure durations of 120 sec to 300 sec. The measured temperatures for various tests with similar flame exposure times were repeatable. A one-dimensional numerical heat transfer model of the test assembly was developed. The close agreement between measured and predicted temperatures on the titanium witness plate and inside the insulation test sample indicated that this test may provide a one-dimensional thermal testing capability for evaluation of thermal performance of similar insulations.

Daryabeigi, Kamran↗

Radiative Heating for MSL Entry: Verification of Simulations from Ground Test to Flight Data

The heat shield of the Mars Science Laboratory (MSL) was equipped with thermocouplestacks to measure in-depth heating of the thermal protection system during atmosphericentry. The heat load derived from the thermocouples in the stagnation region was found tobe 33 lower than corresponding post-flight predictions of convective heating alone. It washypothesized that this difference could be attributed to radiation from the shock-heated gas,a mechanism not considered in post-flight analyses of flow fields. In order to test thehypothesis and quantify the contribution of shock-layer radiation to total surface heating,ground tests and simulations (both flow and radiation) were performed at several pointsalong the best-estimated entry trajectory of MSL. The present paper provides anassessment of the quality of the radiation model and its impact to stagnation point heating.Although the impact of radiative heating is shown to be significant, it only accounts for 43of the discrepancy. Additional factors behind the remaining discrepancy are discussed.

Aeroheating↗

Towards the Prediction of the Mars 2020 Heatshield Material Response

Introduction: NASA’s next mission to Mars, the Mars 2020, will use the same heatshield of the Mars Science Laboratory (MSL) for thermal protection during entry, descent and landing. The heatshield is a tiled system made of Phenolic Impregnated Carbon Ablators (PICA) blocks [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to compare the thermal response of the MSL heatshield to the MISP flight data. In preparation to Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against MEDLI flight data.

heatshield↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan- stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Measured Interfacial Residual Strains Produced by In-Flight Ice

The formation of ice on aircraft is a highly dynamic process during which ice will expand and contract upon freezing and undergoing changes in temperature. Finite Element Analysis (FEA) simulations were performed investigating the stress build up in a simplified case with uniform temperature changes between an idealized ice sample and acrylic substrate. These results were used to place strain gages on custom-built acrylic and aluminum specimens; these specimens were then placed in icing conditions such that ice was grown on top of the specimen. Tee rosettes were placed in two configurations adjacent to thermocouple sensors. It was hypothesized that the ice would expand on freezing and contract as the temperature of the interface returned to the equilibrium conditions. While results from the aluminum specimens matched this hypothesis, results from the acrylic specimens show a short period of contraction followed by a much larger expansion at the interface, indicating more complex ice growth thermodynamics than anticipated. Samples were observed to delaminate, and the data suggests that the residual strain is significant to the shedding of ice for in-flight applications.

residual strain↗

Heatshield Entry Modeling Using a Design, Analysis, and Optimization Toolbox

The Mars Science Laboratory (MSL) was protected during its Mars atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA). PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase the capability of the Design, Analysis, and Optimization of Thermal Protection Materials (DAOTPM) software. DAO-TPM is a Python based framework that works as a link between mission design, aerothermal and radiative environment computation, Thermal Protection Systems (TPS) microstructure analysis, material response and optimization tools. The toolbox has a Graphical User Interface (GUI) that allows the user to build as well as run the various software and utilities used to design, analyze and optimize a heatshield during atmospheric entry.

Meurisse, Jeremie B. E.↗

The Entry Descent and Landing Instrumentation (MEDLI2) Suite for the Mars 2020 Mission

This presentation will discuss the current state of each of the main measurements systems for MEDLI2. The first system is a network of pressure transducers, the Mars Entry Atmospheric Data System (MEADS). Improving upon MEDLI, separate MEDLI2 pressure transducers span the measurement range suitable for both hypersonic and supersonic flows. The MEADS will also measure pressure on the backshell of the vehicle to better characterize the contribution of backshell pressure on the overall forces and moments on the entry probe. The second system is the thermal instrumentation, or Mars Instrumented Sensor Plugs. This system includes a network of high-temperature thermocouples embedded in the thermal protection system across the heatshield and backshell. The MISP also includes two types of sensors for directly measuring incident heatflux on the backshell of the vehicle. In addition, a radiometer is included on the backshell to measure radiative heating. The presentation will also cover the current state of the MEDLI2 hardware, expected environments that will be measured, and data analysis techniques being developed to infer vehicle entry performance from both the MISP and MEADS sensor systems.

White, Todd↗

Charactarization of Thermal Protection Systems

In 2012, NASA's mission of landing the Mars Science Laboratory (MSL) on Mars was successful. MSL was protected by an ablative heatshield of tiled low density material known as PICA (phenolic impregnated carbon ablator). The heatshield was instrumented with MEDLI (MSL Entry Descent Landing Instrument) a suite of sensors & thermocouples at discrete locations in order to monitor the in-depth ablator temperature response and surface pressure. MEDLI was designed and developed by NASA Langley, in partnership with NASA Ames Research Center for the purposes of probing Mars and evaluating the performance of the spacecraft upon entry into the Martian atmosphere. The flight data reduces the uncertainty in engineer models for predicting the response of a spacecraft towards the extreme heating environment of an entry into the Martian atmosphere. MEDLI2 is a part of the Mars 2020 mission and is the next-generation sensor suite for entry, descent, and landing. This data will again help engineers validate their flight models. Additionally, the atmospheric data, can help us understand atmospheric density and winds. This is a critical study for reducing risks to both robotic and future human missions to Mars. Engineered models for Mars 2020 are dependent upon parameters related to the materials response to heating and radiation. In this work, the thermal properties and other measurements of various ablative materials are analyzed to achieve greater utility of the 2012 MEDLI flight data and more accurately determine the parameters being used in Mars 2020. The purpose of this study was to measure specific heat, thermal conductivity, char yield, reflectance as a function of wavelength, and other thermal parameters and optical properties of various ablative materials. CO2(g) at extreme temperatures emits radiation impacting MEDLI2 flight predictions. Emissivity & absorptivity as a function of temperature were calculated from FTIR and UV-Vis data as a means of investigating whether these materials might absorb CO2 radiation upon entry into the Mars atmosphere.

HEEET↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

Infrared Measurements of Forward Heat Conduction during Simulated Microgravity Flame Spread in the Narrow Channel Apparatus

An infrared (IR) camera provides a way of examining temperature trends associated with simulated microgravity flame spread in the Narrow Channel Apparatus (NCA). The IR camera measures the surface temperature of solid poly methyl methacrylate (PMMA) fuel. These tests examine the forward conduction of heat ahead of the flame front in the non-thermally thin fuel.The NCA is a combustion wind tunnel that simulates a microgravity flame spread environment by employing a narrow gap between the fuel and ceiling of the device, limiting the effects of buoyancy. Test conditions of a 5 mm gap, mean opposed flow velocity of 15 cm/s, and fuel thickness of 3 mm are used.PMMA is selected as the fuel due to repeatability of test results, ease of computational modeling, and known combustion mechanics. Using specific lens and bandpass filter combinations the PMMA can be imaged as effectively opaque. The spectral emissivity for PMMA was calculated and incorporated into the calibration of the camera.Surface temperatures from the IR camera are compared to results from thermocouples embedded in the surface of the fuel. The IR camera results show that nontrivial forward conduction occurs during tests, and therefore must be included in computational models of the process.

Berry, Michael↗

Development of Unsteady Pressure-Sensitive Paint Application on NASA Space Launch System

The key measurement to acquire for understanding unsteady flow is surface pressure. Unsteady Pressure-Sensitive Paint (uPSP) is an emerging optical technique used in wind tunnel testing to measure fluctuating surface pressures. Recently, tests were conducted on NASA’s Space Launch System in NASA Ames Research Center’s Unitary Plan Wind Tunnel to determine the aeroacoustics environment and assist in developing the buffet forcing functions. Unsteady PSP data was collected during this test campaign. Steady state PSP data, infrared thermography, shadowgraph, accelerometer data, and dynamic pressure transducer data were also collected. In all 50 TB of data were collected during the three days of testing. During these three days of testing, a repeating transonic and supersonic alpha sweep condition was acquired. This paper presents these two wind tunnel conditions and examines how the temperature influences the PSP data. In the first large demonstration of uPSP in 2015 on an NESC-, AETC-sponsored wind tunnel test, lifetime PSP results highlighted the influence the model temperature had on the PSP data. A best practice of heat soaking the model before acquiring calibration images was followed during the test campaign presented in this paper. An infrared thermography camera and thermocouples were installed in the model to collect more details of the model surface temperature. Data processing schemes for uPSP are still in development but will be briefly presented here as well.

Roozeboom, Nettie H.↗

Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods

The Mars Science Laboratory (MSL) was protected during entry into the Martian atmosphere by a thermal protection system that used NASA’s Phenolic Impregnated Carbon Ablator (PICA). The heat shield of the probe was instrumented with the Mars Entry Descent and Landing Instrument (MEDLI) suite of sensors. MEDLI Integrated Sensor Plugs (MISP) included thermocouples that measured in-depth temperatures at various locations on the heatshield. The flight data has been used as a benchmark for validating ablation codes within NASA. This work seeks to refine the estimate of the material properties for the MSL heat shield and the aerothermal environment during Mars entry using estimation methods in DAKOTA on the temperature data obtained from MEDLI.

Thornton, John M.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data was obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (on the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report. The rest of the data will be published in a future report, Part II, along with planned CFD predictions of the complex cooling film flow. The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Nozzle↗

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗