Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-E-J-117: Verification Method for the Detection Accuracy of Automatic Winston Lutz Test

Purpose: Winston Lutz test (WLT) has been a standard QA procedure performed prior to SRS treatment, to verify the mechanical iso-center setup accuracy upon different Gantry/Couch movements. Several detection algorithms exist,for analyzing the ball-radiation field alignment automatically. However, the accuracy of these algorithms have not been fully addressed. Here, we reveal the possible errors arise from each step in WLT, and verify the software detection accuracy with the Rectilinear Phantom Pointer (RLPP), a tool commonly used for aligning treatment plan coordinate with mechanical iso-center. Methods: WLT was performed with the radio-opaque ball mounted on a MIS and irradiated onto EDR2 films. The films were scanned and processed with an in-house Matlab program for automatic iso-center detection. Tests were also performed to identify the errors arise from setup, film development and scanning process. The radioopaque ball was then mounted onto the RLPP, and offset laterally and longitudinally in 7 known positions ( 0, ±0.2, ±0.5, ±0.8 mm) manually for irradiations. The gantry and couch was set to zero degree for all irradiation. The same scanned images were processed repeatedly to check the repeatability of the software. Results: Miminal discrepancies (mean=0.05mm) were detected with 2 films overlapped and irradiated but developed separately. This reveals the error arise from film processor and scanner alone. Maximum setup errors were found to be around 0.2mm, by analyzing data collected from 10 irradiations over 2 months. For the known shift introduced using the RLPP, the results agree with the manual offset, and fit linearly (R{sup 2}>0.99) when plotted relative to the first ball with zero shift. Conclusion: We systematically reveal the possible errors arise from each step in WLT, and introduce a simple method to verify the detection accuracy of our in-house software using a clinically available tool.

60 APPLIED LIFE SCIENCES↗

Uncertainty in the visibility mask of a survey and its effects on the clustering of biased tracers

The forecasted accuracy of upcoming surveys of large-scale structure cannot be achieved without a proper quantification of the error induced by foreground removal (or other systematics like 0-point photometry offset). Because these errors are highly correlated on the sky, their influence is expected to be especially important at very large scales, at and beyond the first Baryonic Acoustic Oscillation (BAO). In this work we quantify how the uncertainty in the visibility mask of a survey, that gives the survey depth in a specific sky area, influences the measured power spectrum of a sample of tracers of the density field and its covariance matrix. We start from a very large set of 10,000 catalogs of dark matter (DM) halos in periodic cosmological boxes, produced with the PINOCCHIO approximate method. To make an analytic approach feasible, we assume luminosity-independent halo bias and an idealized geometry for the visibility mask, that is constant in square tiles of physical length l ; this should be interpreted as the projection, at the observation redshift, of the angular correlation scale of the foreground residuals. We find that the power spectrum of these biased tracers can be expressed as the sum of a cosmological term, a mask term and a term involving their convolution. The mask and convolution terms scale like P ∝ l {sup 2}σ {sub A} {sup 2}, where σ {sub A} {sup 2} is the variance of the uncertainty on the visibility mask. With l = 30−100 Mpc/ h and σ {sub A} = 5−20%, the mask term can be significant at k ∼ 0.01−0.1 h /Mpc, and the convolution term can amount to ∼ 1−10% of the total. The influence of mask uncertainty on power spectrum covariance is more complicated: the coupling of the convolution term with the other two gives rise to several mixed terms, that we quantify by difference using the mock catalogs. These are found to be of the same order of the mask covariance, and to introduce non-diagonal terms at large scales. As a consequence, the power spectrum covariance matrix cannot be expressed as the sum of a cosmological and of a mask term. More realistic settings (realistic foregrounds, luminosity-dependent bias) make the analytical approach not feasible, and the problem requires on the one hand usage of extended sets of mock catalogs, on the other hand detailed knowledge of the correlations among errors in the visibility masks. Our results lie down the theoretical bases to quantify the impact that uncertainties in the mask calibration have on the derivation of cosmological constraints from large spectroscopic surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of Φ₃ with a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decay

We present the first measurement of the angle Φ₃ of the unitarity triangle using a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decays. The method uses, as input, measurements of the strong phase of the D→K⁰ S π⁺π⁻ amplitude from the CLEO Collaboration. The result is based on the full data set of 772×106 BB¯¯¯ pairs collected by the Belle experiment at the Υ(4S) resonance. We obtain Φ₃=(77.3 +15.1 –14.9 ±4.1±4.3)° and the suppressed amplitude ratio r B =0.145±0.030±0.010±0.011. Here the first error is statistical, the second is the experimental systematic uncertainty, and the third is the error due to the precision of the strong-phase parameters obtained by CLEO.

Aihara, H.↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study

Purpose: Setup errors and prostate intrafraction motion are main sources of localization uncertainty in prostate cancer radiation therapy. This study evaluates four different imaging modalities 3D ultrasound (US), kV planar images, cone-beam computed tomography (CBCT), and implanted electromagnetic transponders (Calypso/Varian) to assess inter- and intrafraction localization errors during intensity-modulated radiation therapy based treatment of prostate cancer. Methods: Twenty-seven prostate cancer patients were enrolled in a prospective IRB-approved study and treated to a total dose of 75.6 Gy (1.8 Gy/fraction). Overall, 1100 fractions were evaluated. For each fraction, treatment targets were localized using US, kV planar images, and CBCT in a sequence defined to determine setup offsets relative to the patient skin tattoos, intermodality differences, and residual errors for each patient and patient cohort. Planning margins, following van Herk's formalism, were estimated based on error distributions. Calypso-based localization was not available for the first eight patients, therefore centroid positions of implanted gold-seed markers imaged prior to and immediately following treatment were used as a motion surrogate during treatment. For the remaining 19 patients, Calypso transponders were used to assess prostate intrafraction motion. Results: The means ({mu}), and standard deviations (SD) of the systematic ({Sigma}) and random errors ({sigma}) of interfraction prostate shifts (relative to initial skin tattoo positioning), as evaluated using CBCT, kV, and US, averaged over all patients and fractions, were: [{mu}{sub CBCT}= (-1.2, 0.2, 1.1) mm, {Sigma}{sub CBCT}= (3.0, 1.4, 2.4) mm, {sigma}{sub CBCT}= (3.2, 2.2, 2.5) mm], [{mu}{sub kV}= (-2.9, -0.4, 0.5) mm, {Sigma}{sub kV}= (3.4, 3.1, 2.6) mm, {sigma}{sub kV}= (2.9, 2.0, 2.4) mm], and [{mu}{sub US}= (-3.6, -1.4, 0.0) mm, {Sigma}{sub US}= (3.3, 3.5, 2.8) mm, {sigma}{sub US}= (4.1, 3.8, 3.6) mm], in the anterior-posterior (A/P), superior-inferior (S/I), and the left-right (L/R) directions, respectively. In the treatment protocol, adjustment of couch was guided by US images. Residual setup errors as assessed by kV images were found to be: {mu}{sub residual}= (-0.4, 0.2, 0.2) mm, {Sigma}{sub residual}= (1.0, 1.0,0.7) mm, and {sigma}{sub residual}= (2.5, 2.3, 1.8) mm. Intrafraction prostate motion, evaluated using electromagnetic transponders, was: {mu}{sub intrafxn}= (0.0, 0.0, 0.0) mm, {Sigma}{sub intrafxn}= (1.3, 1.5, 0.6) mm, and {sigma}{sub intrafxn}= (2.6, 2.4, 1.4) mm. Shifts between pre- and post-treatment kV images were: {mu}{sub kV(post-pre)}= (-0.3, 0.8, -0.2), {Sigma}{sub kV(post-pre)}= (2.4, 2.7, 2.1) mm, and {sigma}{sub kV(post-pre)}= (2.7, 3.2, 3.1) mm. Relative to skin tattoos, planning margins for setup error were within 10-11 mm for all image-based modalities. The use of image guidance was shown to reduce these margins to less than 5 mm. Margins to compensate for both residual setup (interfraction) errors as well as intrafraction motion were 6.6, 6.8, and 3.9 mm in the A/P, S/I, and L/R directions, respectively. Conclusions: Analysis of interfraction setup errors, performed with US, CBCT, planar kV images, and electromagnetic transponders, from a large dataset revealed intermodality shifts were comparable (within 3-4 mm). Interfraction planning margins, relative to setup based on skin marks, were generally within the 10 mm prostate-to-planning target volume margin used in our clinic. With image guidance, interfraction residual planning margins were reduced to approximately less than 4 mm. These findings are potentially important for dose escalation studies using smaller margins to better protect normal tissues.

60 APPLIED LIFE SCIENCES↗

Total experimental uncertainty in hydrodynamic testing of a semisubmersible wind turbine, considering numerical propagation of systematic uncertainty

Quantifying the uncertainty in experimental results is a vital step in properly validating numerical simulation tools for designing floating wind turbines; without a good understanding of the experimental uncertainties, it is impossible to confirm if numerical simulation tools can capture the physics with acceptable accuracy. Recent validation studies suggest that the wave-induced, low-frequency surge and pitch motions of semisubmersible-type floating wind turbines are consistently underpredicted by numerical simulations, but it has not been possible to state whether or not this underprediction is within the level of experimental error. Here, previously assessed systematic uncertainty components in hydrodynamic tests of the OC5-DeepCwind semisubmersible are propagated to response metrics of interest using numerical simulation tools, and combined with the system's random uncertainty to obtain the total experimental uncertainty. The uncertainty in the low-frequency response metrics is found to be most sensitive to the system properties (e.g., mooring stiffness and center of gravity), and also the wave elevation. The results of the present study suggest that the underprediction of the low-frequency response behavior observed in previous validation studies is larger than the experimental uncertainty.

17 WIND ENERGY↗

Determination of the Chiral Condensate from (2+1)-Flavor Lattice QCD

We perform a precise calculation of the chiral condensate in QCD using lattice QCD with 2+1 flavors of dynamical overlap quarks. Up and down quark masses cover a range between 3 and 100 MeV on a 16{sup 3}x48 lattice at a lattice spacing {approx}0.11 fm. At the lightest sea quark mass, the finite volume system on the lattice is in the {epsilon} regime. By matching the low-lying eigenvalue spectrum of the Dirac operator with the prediction of chiral perturbation theory at the next-to-leading order, we determine the chiral condensate in (2+1)-flavor QCD with strange quark mass fixed at its physical value as {Sigma}{sup MS}(2 GeV)=[242(04)((+19/-18)) MeV]{sup 3} where the errors are statistical and systematic, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlated theoretical uncertainties for the one-jet inclusive cross section

We discuss the correlated systematic theoretical uncertainties that may be ascribed to the next-to-leading order QCD theory used to predict the one-jet inclusive cross section in hadron collisions. We estimate the magnitude of these errors as functions of the jet transverse momentum and rapidity. The total theoretical error is decomposed into a set of functions of transverse momentum and rapidity that give a model for statistically independent contributions to the error. This representation can be used to include the systematic theoretical errors in fits to the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-EF-304-03: 4D Monte Carlo Robustness Test for Proton Therapy

Purpose: Breathing motion and approximate dose calculation engines may increase proton range uncertainties. We address these two issues using a comprehensive 4D robustness evaluation tool based on an efficient Monte Carlo (MC) engine, which can simulate breathing with no significant increase in computation time. Methods: To assess the robustness of the treatment plan, multiple scenarios of uncertainties are simulated, taking into account the systematic and random setup errors, range uncertainties, and organ motion. Our fast MC dose engine, called MCsquare, implements optimized models on a massively-parallel computation architecture and allows us to accurately simulate a scenario in less than one minute. The deviations of the uncertainty scenarios are then reported on a DVH-band and compared to the nominal plan.The robustness evaluation tool is illustrated in a lung case by comparing three 60Gy treatment plans. First, a plan is optimized on a PTV obtained by extending the CTV with an 8mm margin, in order to take into account systematic geometrical uncertainties, like in our current practice in radiotherapy. No specific strategy is employed to correct for tumor and organ motions. The second plan involves a PTV generated from the ITV, which encompasses the tumor volume in all breathing phases. The last plan results from robust optimization performed on the ITV, with robustness parameters of 3% for tissue density and 8 mm for positioning errors. Results: The robustness test revealed that the first two plans could not properly cover the target in the presence of uncertainties. CTV-coverage (D95) in the three plans ranged respectively between 39.4–55.5Gy, 50.2–57.5Gy, and 55.1–58.6Gy. Conclusion: A realistic robustness verification tool based on a fast MC dose engine has been developed. This test is essential to assess the quality of proton therapy plan and very useful to study various planning strategies for mobile tumors. This work is partly funded by IBA (Louvain-la-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of model improvements on 80 m wind speeds during the second Wind Forecast Improvement Project (WFIP2)

Abstract. During the second Wind Forecast Improvement Project (WFIP2; October 2015–March 2017, held in the Columbia River Gorge and Basin area of eastern Washington and Oregon states), several improvements to the parameterizations used in the High Resolution Rapid Refresh (HRRR – 3 km horizontal grid spacing) and the High Resolution Rapid Refresh Nest (HRRRNEST – 750 m horizontal grid spacing) numerical weather prediction (NWP) models were tested during four 6-week reforecast periods (one for each season). For these tests the models were run in control (CNT) and experimental (EXP) configurations, with the EXP configuration including all the improved parameterizations. The impacts of the experimental parameterizations on the forecast of 80 m wind speeds (wind turbine hub height) from the HRRR and HRRRNEST models are assessed, using observations collected by 19 sodars and three profiling lidars for comparison. Improvements due to the experimental physics (EXP vs. CNT runs) and those due to finer horizontal grid spacing (HRRRNEST vs. HRRR) and the combination of the two are compared, using standard bulk statistics such as mean absolute error (MAE) and mean bias error (bias). On average, the HRRR 80 m wind speed MAE is reduced by 3 %–4 % due to the experimental physics. The impact of the finer horizontal grid spacing in the CNT runs also shows a positive improvement of 5 % on MAE, which is particularly large at nighttime and during the morning transition. Lastly, the combined impact of the experimental physics and finer horizontal grid spacing produces larger improvements in the 80 m wind speed MAE, up to 7 %–8 %. The improvements are evaluated as a function of the model's initialization time, forecast horizon, time of the day, season of the year, site elevation, and meteorological phenomena. Causes of model weaknesses are identified. Finally, bias correction methods are applied to the 80 m wind speed model outputs to measure their impact on the improvements due to the removal of the systematic component of the errors.

17 WIND ENERGY↗

z'-BAND GROUND-BASED DETECTION OF THE SECONDARY ECLIPSE OF WASP-19b

We present the ground-based detection of the secondary eclipse of the transiting exoplanet WASP-19b. The observations were made in the Sloan z' band using the ULTRACAM triple-beam CCD camera mounted on the New Technology Telescope. The measurement shows a 0.088% {+-} 0.019% eclipse depth, matching previous predictions based on H- and K-band measurements. We discuss in detail our approach to the removal of errors arising due to systematics in the data set, in addition to fitting a model transit to our data. This fit returns an eclipse center, T{sub 0}, of 2455578.7676 HJD, consistent with a circular orbit. Our measurement of the secondary eclipse depth is also compared to model atmospheres of WASP-19b and is found to be consistent with previous measurements at longer wavelengths for the model atmospheres we investigated.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Reconciliation and Gross Error Detection: A Filtered Measurement Test

Measured process data commonly contain inaccuracies because the measurements are obtained using imperfect instruments. As well as random errors one can expect systematic bias caused by miscalibrated instruments or outliers caused by process peaks such as sudden power fluctuations. Data reconciliation is the adjustment of a set of process data based on a model of the process so that the derived estimates conform to natural laws. In this paper, we will explore a predictor-corrector filter based on data reconciliation, and then a modified version of the measurement test is combined with the studied filter to detect probable outliers that can affect process measurements. The strategy presented is tested using dynamic simulation of an inverted pendulum.

99 GENERAL AND MISCELLANEOUS↗

Precise determination of B{sub K} and light quark masses in quenched domain-wall QCD

We calculate nonperturbative renormalization factors at hadronic scale for {delta}S=2 four-quark operators in quenched domain-wall QCD using the Schroedinger functional method. Combining them with the nonperturbative renormalization group running by the Alpha Collaboration, our result yields the fully nonperturbative renormalization factor, which converts the lattice bare B{sub K} to the renormalization group invariant (RGI) B-circumflex{sub K}. Applying this to the bare B{sub K} previously obtained by the CP-PACS Collaboration at a{sup -1}{approx_equal}2,3,4 GeV, we obtain B-circumflex{sub K}=0.782(5)(7) [equivalent to B{sub K}{sup MS}(NDR,2 GeV)=0.565(4)(5) by two-loop running] in the continuum limit, where the first error is statistical and the second is systematic due to the continuum extrapolation. Except the quenching error, the total error we have achieved is less than 2%, which is much smaller than the previous ones. Taking the same procedure, we obtain m{sub u,d}{sup RGI}=5.613(66) MeV and m{sub s}{sup RGI}=147.1(17) MeV [equivalent to m{sub u,d}{sup MS}(2 GeV)=4.026(48) MeV and m{sub s}{sup MS}(2 GeV)=105.6(12) MeV by four-loop running] in the continuum limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atmospheric Dispersion Effects in Weak Lensing Measurements

The wavelength dependence of atmospheric refraction causes elongation of finite-bandwidth images along the elevation vector, which produces spurious signals in weak gravitational lensing shear measurements unless this atmospheric dispersion is calibrated and removed to high precision. Because astrometric solutions and PSF characteristics are typically calibrated from stellar images, differences between the reference stars' spectra and the galaxies' spectra will leave residual errors in both the astrometric positions (dr) and in the second moment (width) of the wavelength-averaged PSF (dv) for galaxies.We estimate the level of dv that will induce spurious weak lensing signals in PSF-corrected galaxy shapes that exceed the statistical errors of the DES and the LSST cosmic-shear experiments. We also estimate the dr signals that will produce unacceptable spurious distortions after stacking of exposures taken at different airmasses and hour angles. We also calculate the errors in the griz bands, and find that dispersion systematics, uncorrected, are up to 6 and 2 times larger in g and r bands,respectively, than the requirements for the DES error budget, but can be safely ignored in i and z bands. For the LSST requirements, the factors are about 30, 10, and 3 in g, r, and i bands,respectively. We find that a simple correction linear in galaxy color is accurate enough to reduce dispersion shear systematics to insignificant levels in the r band for DES and i band for LSST,but still as much as 5 times than the requirements for LSST r-band observations. More complex corrections will likely be able to reduce the systematic cosmic-shear errors below statistical errors for LSST r band. But g-band effects remain large enough that it seems likely that induced systematics will dominate the statistical errors of both surveys, and cosmic-shear measurements should rely on the redder bands.

79 ASTRONOMY AND ASTROPHYSICS↗

A Method for Evaluating Quality Assurance Needs in Radiation Therapy

The increasing complexity of modern radiation therapy planning and delivery techniques challenges traditional prescriptive quality control and quality assurance programs that ensure safety and reliability of treatment planning and delivery systems under all clinical scenarios. Until now quality management (QM) guidelines published by concerned organizations (e.g., American Association of Physicists in Medicine [AAPM], European Society for Therapeutic Radiology and Oncology [ESTRO], International Atomic Energy Agency [IAEA]) have focused on monitoring functional performance of radiotherapy equipment by measurable parameters, with tolerances set at strict but achievable values. In the modern environment, however, the number and sophistication of possible tests and measurements have increased dramatically. There is a need to prioritize QM activities in a way that will strike a balance between being reasonably achievable and optimally beneficial to patients. A systematic understanding of possible errors over the course of a radiation therapy treatment and the potential clinical impact of each is needed to direct limited resources in such a way to produce maximal benefit to the quality of patient care. Task Group 100 of the AAPM has taken a broad view of these issues and is developing a framework for designing QM activities, and hence allocating resources, based on estimates of clinical outcome, risk assessment, and failure modes. The report will provide guidelines on risk assessment approaches with emphasis on failure mode and effect analysis (FMEA) and an achievable QM program based on risk analysis. Examples of FMEA to intensity-modulated radiation therapy and high-dose-rate brachytherapy are presented. Recommendations on how to apply this new approach to individual clinics and further research and development will also be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A procedure for the estimation of the numerical uncertainty of CFD calculations based on grid refinement studies

This paper offers a procedure for the estimation of the numerical uncertainty of any integral or local flow quantity as a result of a fluid flow computation; the procedure requires solutions on systematically refined grids. The error is estimated with power series expansions as a function of the typical cell size. These expansions, of which four types are used, are fitted to the data in the least-squares sense. The selection of the best error estimate is based on the standard deviation of the fits. The error estimate is converted into an uncertainty with a safety factor that depends on the observed order of grid convergence and on the standard deviation of the fit. For well-behaved data sets, i.e. monotonic convergence with the expected observed order of grid convergence and no scatter in the data, the method reduces to the well known Grid Convergence Index. Examples of application of the procedure are included. - Highlights: • Estimation of the numerical uncertainty of any integral or local flow quantity. • Least squares fits to power series expansions to handle noisy data. • Excellent results obtained for manufactured solutions. • Consistent results obtained for practical CFD calculations. • Reduces to the well known Grid Convergence Index for well-behaved data sets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗