Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

The development, testing and characterisation of a straw tracking detector and readout system for the Fermilab muon g-2 experiment

The anomalous magnetic moments of leptons can be both measured and theoretically predicted with high precision, and as such provide stringent tests of the Standard Model (SM) of particle physics. The anomalous magnetic moment of the muon, $a_\mu$, in particular offers sensitivity to new physics within the reach of current experiments. The current world’s best measurement of aμ made at the Brookhaven National Laboratory (BNL) deviates from the SM prediction by over 3σ, providing a tantalising but inconclusive hint that contributions from new physics may be present. A new $a_\mu$ experiment is currently under construction at the Fermi National Accelerator Laboratory (Fermilab), known as the Fermilab muon g-2 experiment. Due to commence in 2017, this new experiment is expected to improve the experimental measurement precision of $a_\mu$ by a factor of 4, and is seeking to confirm or reject the current discrepancy. The experiment, like its BNL predecessor, will measure the precession of the $\mu^{+}$ spin in a magnetic storage-ring. This new experiment has three straw tracking detectors used to measure the beam profile of the stored $\mu^{+}$, as well as other dynamic properties of the beam. This thesis describes the design of these detectors, and the data acquisition system and subsequent data processing systems that have been developed to read them out and make their data available for physics analysis. The performance of the straw trackers and the readout systems at a number of beam tests and test stands is presented, in addition to Monte-Carlo simulations of the trackers in the final experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

04BM XFM Beamline Radiation Shielding Analysis

The radiation shielding of the 04-BM-XFM beam line is analyzed for the gas bremsstrahlung (GB) and synchrotron radiation (SR) sources. The GB as a source originates from the long straight section of the storage ring during normal operation when the primary electrons interact with the residual gas molecules in the beam transport pipe giving rise to bremsstrahlung radiation. When the safety shutters are open, this can stream through the beampipe into the first optical enclosure (FOE) and beyond and can result in a radiation environment that is present at a constant rate.

36 MATERIALS SCIENCE↗

Shielding Analysis of the 22BM-FIS/MET Beampipe Penetration

The purpose of this report is to determine the shielding required, both on the inside and outside of the penetration through the storage ring shielding, which is required for the FIS/MET beamlines IR beampipe. The aim is to ensure that the dose rates in the occupied areas near the penetration comply with the NSLS-II shielding policy [1] for both normal and abnormal beam loss conditions.

36 MATERIALS SCIENCE↗

Rachet Door Shielding Design Calculations

The ratchet wall at the experimental floor side will have sliding doors to provide access to beamline front ends during installation and maintenance. The thickness and design of these sliding doors should provide shielding equivalence of the concrete thickness of the ratchet wall. Each of the sliding doors will be a composite to provide effective shielding from neutron and gamma radiation, emanating from beam losses inside the storage ring.

36 MATERIALS SCIENCE↗

Radiological Considerations of Top-off Operation at NSLS-II

High current (500 mA) and low emittance (~1 nm) have been specified for NSLS-II to achieve ultra high brightness in a medium energy (3 GeV) storage ring (1) . This leads to the expectation that the lifetime in NSLS-II will be limited by Touschek scattering, and after commissioning will settle in at ~3 hours. It may well be less in the early days of operation. At the same time, the intensity stability specified by the user community is 1% or better.

36 MATERIALS SCIENCE↗

Evaluation of Maximum Dose Rate Resulting from Failure of the Linac Charge Monitoring System

This evaluation was prepared in response to a request from the Accelerator Readiness Review Team for NSLS-II Routine Operations. The purpose of this evaluation is to document the maximum dose rate potential for failures in the linac charge monitoring system. It is noted that the probability of such a failure is extremely low and likely never realized. For the failure to occur, the linac injection has to be set to maximum output, monitoring devices as displayed in the Control Room would go unnoticed by the Operators, the Operator on duty would have to fail to recognize the event, other accumulating charge monitors that alarm at ASE limits would also need to fail or would have to go unrecognized by the Operator and finally there would have to be a simultaneous fault in the storage ring to generate dose on the experimental floor. Regardless of these multiple layers of protection, the maximum dose rate to staff on the NSLS-II experimental floor is presented below.

36 MATERIALS SCIENCE↗

Redundancy and SIL Requirements for the Safety Rated ACMI

The purpose of this analysis is to determine if the Safety Rated Accumulated Charge Monitor Interlock (ACMI) that is being designed for the Linac to Booster Transport Line requires redundant monitoring components and Programmable Logic Controllers (PLCs) and define the minimum Safety Integrity Level (SIL) for the ACMI system. The ACMI is required to monitor and limit the amount of total injected electron charge that can be transported from the Linac into the Booster, and consequently into the Storage Ring. The ACMI is one of the key components that assure compliance with the NSLS-II Accelerator Safety Envelope [1].

36 MATERIALS SCIENCE↗

Safety Integrity Level and Redundancy Requirements for the Top-Off Safety System

The purpose of this analysis is to evaluate the potential impacts resulting from the failure of the Top-Off Safety System (TOSS) and determine the minimum Safety Integrity Level (SIL) for the system. The TOSS consists of a series of apertures, interlocking monitors including current and voltage and electron beam stored current and other controls to ensure that the electron beam injected into the NSLS-II storage ring does not disturb the circulating electron beam and that the electron beam trajectory remains stable.

36 MATERIALS SCIENCE↗

Detecting Single Electrons in IOTA [Slides]

Detect synchrotron-light signal and characterize backgrounds in IOTA for 1) Beam diagnostics: turn-by-turn intensity monitor with wide dynamic range, from nominal intensities (~10 9 particles) down to single electrons; 2) Scientific experiments in IOTA: what is the time structure of radiation emission from a single electron in a storage ring? Is it random, regular, chaotic? Is there correlation between the emission from different dipoles?

43 PARTICLE ACCELERATORS↗

Operation of the NSLS-II Injector with a Lower Booster Injection Energy

The NSLS-II injector consists of a 200 MeV linac and a 3 GeV full-energy booster synchrotron. The linac contains five traveling-wave S-band accelerating structures driven by two high-power klystrons. Optimization of the NSLS-II injector has continued since user operation started in October 2014. Beam losses have been minimized by the injector tuning and stabilization, and high level software has been developed to characterize the booster and injection parameters. However, due to the recently increased frequency of klystrons arcing which shortens the lifetime of the klystron, operation of the linac with lowered klystron output power would allow injection to be maintained with fewer trips and extended lifetime of klystrons. Apart from the energy difference, the low energy klystron operation is quite similar to the nominal 200 MeV operation. Injection trials were carried out with scaled magnet settings of the linac, linac-to- booster (LtB) transport line, and the booster. The beam was successfully injected into the booster on May 31, 2017 at the low energy mode of the 170 MeV LtB injection. Overall transfer efficiency from the linac to the storage ring is identical to the standard 200 MeV operation. The 170 MeV injection mode has been adopted in NSLS-II user operation ever since the beam study. In the most recent injector studies on June 28 and July 3, 2017, the booster injection energy was further decremented to the final target value of 100 MeV via applying the same method established in the 170 MeV operation. The ultimate value of 100 MeV is determined by the special requirement of operating the injector at single klystron while repairing the other klystron or with two klystrons with significantly reduced outputs for the purpose of maximizing klystron lifetimes.

36 MATERIALS SCIENCE↗

Effects of a long low-gap in-vacuum undulator on the impedance and beam lifetime

Possible installation of a long low-gap in-vacuum undulator in the NSLS-II storage ring could result in several impedance-related and beam lifetime issues. High impedance of the low-gap undulator can result in beam instabilities and beam-induced overheating of the undulator itself. These issues have been preliminary studied using analytical formulae, computer simulations and experience of operations with existing in-vacuum undulators. Depending on the device location, the minimum gap and the overall ring-average residual gas pressure, an in-vacuum undulator (IVU) may appreciably shorten the elastic gas scattering component of the beam lifetime. When the latter becomes comparable to the Touschek lifetime, a significant reduction of the total beam lifetime will occur. Here this effect is studied by applying some well-known analytical formulas, as well as insights from NSLS-II operating experience. Finally, the issue of IVU radiation damage also needs to be looked at, and potentially addressed with a dedicated collimation system.

36 MATERIALS SCIENCE↗

Betatron Tune Shifts Induced by the Low-Frequency Resistive Wall Impedance

An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability $μ_r$. In the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets ($μ_r$ → $\infty$), and the case in which the magnets are fully saturated ($μ_r$ = 1).

36 MATERIALS SCIENCE↗

Hazard Analysis for 90 MeV Booster Injection Energy Limit

The NSLS-II booster is designed to accelerate 200 MeV electrons to an energy of 3 GeV to serve as a full energy injector for the NSLS-II storage ring. Electrons are supplied to the booster from the NSLS-II linac. The NSLS-II booster was specified to accept electrons with an energy as low as 170 MeV. The supplemental shielding is designed to shield all energies from 150 MeV to the booster’s maximum energy of 3.2 GeV. Due to the shielding design, the NSLS-II PPS system guarantees that the beam energy must be above 151 MeV upon transport to the booster ring for injection. Recently, problems with the linac klystrons have come to the point that operating the NSLS-II linac below the 150 MeV may be the only possible way for the linac to deliver electrons to the booster. If the NSLS-II linac were limited to operate on only 1 klystron, at full power only 120 MeV beam energy would be possible. The nominal operating energy would be 100 MeV to leave overhead for beam loading compensation and to not stress the last remaining klystron any more than necessary. Since this is below the design of the booster shielding, the supplemental shielding needs to be analyzed to ensure that it is sufficient for lower energy beams. In this report, we discuss the impact of lowering the booster injection energy to 90 MeV on the supplemental shielding. Issues relating to how the booster will perform at this lower energy are not discussed.

36 MATERIALS SCIENCE↗

The R&D of NSLS-II Girder Profiling

A precise state-of-the-art vibrating wire technique will be adopted to achieve the challenging ±30 μm magnet-magnet positioning requirement in NSLS-II storage ring. However, girder profile variation after relocation will merge all the efforts of precise magnet alignment. Girder profiling, a 2-steps process including baseline establishment and restoration in tunnel which never been applied before in accelerator field, will be implemented to keep the girder profile between magnetic measurement room and tunnel as close as possible. Laser tracker is chosen as the main instrument. Tests in environmentally controlled room indicate that a repeatability accuracy of ±10 μm can be achieved by laser tracker in several days period and it has the resolution of better than ±5 μm if serving as an indicator. Simulations and tests prove that an accuracy of better than ±10 μm can be achieved for both steps; therefore, the final magnet-magnet alignment accuracy can be better than ±20 μm. Most of the R&D activities will be presented.

36 MATERIALS SCIENCE↗

Dose rates near the Service Buildings for Al, Cu, Fe and Pb targets

Fluka simulations were performed to model fault conditions that result in the electron beam hitting different materials found in the storage ring (SR), namely aluminum in beam pipes, copper in magnet coils, iron in magnet yokes and lead in local shields. The primary goal of the simulations was to determine dose distributions outside the bulk shielding due to beam losses for different fault conditions. These predicted doses can be used to provide guidance regarding the need for additional shielding or administrative safeguards. A secondary goal was to compare the simulated dose at three different locations with the dose obtained from analytical calculations using the thick target approximation. The analytical calculations are quick and easy and do not require detailed modeling of the geometry. If these calculations can indeed provide reasonably accurate estimates of the dose then they can be used instead of the detailed FLUKA simulations which require more time, effort and computational resources. However the assumptions embedded in the analytical methods result in the maximum possible yield of secondary particles and will therefore overestimate the radiation dose and the radiation shielding required.

36 MATERIALS SCIENCE↗