Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Internal structure of the San Jacinto fault zone at the Ramona Reservation, north of Anza, California, from dense array seismic data

SUMMARY We image the internal structure of the San Jacinto fault zone (SJFZ) near Anza, California, with seismic data recorded by two dense arrays (RA and RR) from ∼42 000 local and ∼180 teleseismic events occurring between 2012 and 2017. The RA linear array has short aperture (∼470 m long with 12 strong motion sensors) and recorded for the entire analysed time window, whereas the RR is a large three-component nodal array (97 geophones across a ∼2.4 km × 1.4 km area) that operated for about a month in September–October 2016. The SJFZ at the site contains three near-parallel surface traces F1, F2 and F3 from SW to NE that have accommodated several Mw > 6 earthquakes in the past 15 000 yr. Waveform changes in the fault normal direction indicate structural discontinuities that are consistent with the three fault surface traces. Relative slowness from local events and delay time analysis of teleseismic arrivals in the fault normal direction suggest a slower SW side than the NE with a core damage zone between F1 and F2. This core damage zone causes ∼0.05 s delay at stations RR26–31 in the teleseismic P arrivals compared with the SW-most station, and generates both P- and S-type fault zone trapped waves. Inversion of S trapped waves indicates the core damaged structure is ∼100 m wide, ∼4 km deep with a Q value of ∼20 and 40 per cent S-wave velocity reduction compared with bounding rocks. Fault zone head waves observed at stations SW of F3 indicate a local bimaterial interface that separates the locally faster NE block from the broad damage zone in the SW at shallow depth and merges with a deep interface that separates the regionally faster NE block from rocks to the SW with slower velocities at greater depth. The multiscale structural components observed at the site are related to the geological and earthquake rupture history at the site, and provide important information on the preferred NW propagation of earthquake ruptures on the San Jacinto fault.

Geochemistry & Geophysics↗

Modulation of seismic noise near the San Jacinto fault in southern California: origin and observations of the cyclical time dependence and associated crustal properties

SUMMARY We examine the cyclic amplitude variation of seismic noise recorded by continuous three-component broad-band seismic data with durations spanning 91–713 d (2008–2011) from three different networks: Anza seismic network, IDA network and the transportable seismic array. These stations surround the San Jacinto Fault Zone (SJFZ) in southern California. We find the seismic noise amplitudes exhibit a cyclical variation between 0.3 and 7.2 Hz. The high-frequency (≥0.9 Hz) noise variations can be linked to human activity and are not a concern. Our primary interest is signals in the low frequencies (0.3–0.9 Hz), where the seismic noise is modulated by semi-diurnal tidal mode M2. These long-period (low-frequency) variations of seismic noise can be attributed to a temporal change of the ocean waves breaking at the shoreline, driven by ocean tidal loading. We focus on the M2 variation of seismic noise at f = 0.6 Hz, travelling distances of ∼92 km through the crust from offshore California to the inland Anza, California, region. Relative to the shoreline station, data from the inland stations show a phase lag of ∼ –12°, which we attribute to the cyclic change in M2 that can alter crustal seismic attenuation. We also find that for mode M2 at 0.6 Hz, the amplitude variations of the seismic quality factor (Q) depend on azimuth and varies from 0.22 per cent (southeast to northwest) to 1.28 per cent (northeast to southwest) with Q = 25 for Rayleigh waves. We propose the direction dependence of the Q variation at 0.6 Hz reflects the preferred orientation of subfaults parallel to the main faulting defined by the primarily N45°W strike of the SJFZ.

Geochemistry & Geophysics↗

Evaluating the location capabilities of a regional infrasonic network in Utah, US, using both ray tracing-derived and empirical-derived celerity-range and backazimuth models

SUMMARY More realistic models for infrasound signal propagation across a region can be used to improve the precision and accuracy of spatial and temporal source localization estimates. Motivated by incomplete infrasound event bulletins in the Western US, the location capabilities of a regional infrasonic network of stations located between 84–458 km from the Utah Test and Training Range, Utah, USA, is assessed using a series of near-surface explosive events with complementary ground truth (GT) information. Signal arrival times and backazimuth estimates are determined with an automatic F-statistic based signal detector and manually refined by an analyst. This study represents the first application of three distinct celerity-range and backazimuth models to an extensive suite of realistic signal detections for event location purposes. A singular celerity and backazimuth deviation model was previously constructed using ray tracing analysis based on an extensive archive of historical atmospheric specifications and is applied within this study to test location capabilities. Similarly, a set of multivariate, season and location specific models for celerity and backazimuth are compared to an empirical model that depends on the observations across the infrasound network and the GT events, which accounts for atmospheric propagation variations from source to receiver. Discrepancies between observed and predicted signal celerities result in locations with poor accuracy. Application of the empirical model improves both spatial localization precision and accuracy; all but one location estimates retain the true GT location within the 90 per cent confidence bounds. Average mislocation of the events is 15.49 km and average 90 per cent error ellipse areas are 4141 km2. The empirical model additionally reduces origin time residuals; origin time residuals from the other location models are in excess of 160 s while residuals produced with the empirical model are within 30 s of the true origin time. We demonstrate that event location accuracy is driven by a combination of signal propagation model and the azimuthal gap of detecting stations. A direct relationship between mislocation, error ellipse area and increased station azimuthal gaps indicate that for sparse networks, detection backazimuths may drive location biases over traveltime estimates.

58 GEOSCIENCES↗

Combining different 3-D global and regional seismic wave propagation solvers towards box tomography in the deep Earth

SUMMARY In previous publications, we presented a general framework, which we called ‘box tomography’, that allows the coupling of any two different numerical seismic wave propagation solvers, respectively outside and inside a target region, or ‘box’. The goal of such hybrid wavefield computations is to reduce the cost of computations in the context of full-waveform inversion for structure within the target region, when sources and/or receivers are located at large distances from the box. Previously, we had demonstrated this approach with sources and receivers outside the target region in a 2-D acoustic spherical earth model, and demonstrated and applied this methodology in the 3-D spherical elastic Earth in a continental scale inversion in which all stations were inside the target region. Here we extend the implementation of the approach to the case of a 3-D global elastic earth model in the case where both sources and stations are outside the box. We couple a global 3-D solver, SPECFEM3D_GLOBE, for the computation of the wavefield and Green’s functions in a reference 3-D model, with a regional 3-D solver, RegSEM, for the computation of the wavefield within the box, by means of time-reversal mirrors. We briefly review key theoretical aspects, showing in particular how only the displacement is needed to be stored at the boundary of the box. We provide details of the practical implementation, including the geometrical design of the mirrors, how we deal with different sizes of meshes in the two solvers, and how we address memory-saving through the use of B-spline compression of the recorded wavefield on the mirror. The proposed approach is numerically efficient but also versatile, since adapting it to other solvers is straightforward and does not require any changes in the solver codes themselves, as long as the displacement can be recovered at any point in time and space. We present benchmarks of the hybrid computations against direct computations of the wavefield between a source and an array of stations in a realistic geometry centred in the Yellowstone region, with and without a hypothetical plume within the ‘box’, and with a 1-D or a 3-D background model, down to a period of 20 s. The ultimate goal of this development is for applications in the context of imaging of remote target regions in the deep mantle, such as, for example, Ultra Low Velocity Zones.

Geochemistry & Geophysics↗

A Pn magnitude scale m b ( Pn ) for earthquakes along the equatorial Mid-Atlantic Ridge

We developed a short-period Pn magnitude scale m b (Pn) for earthquakes along the equatorial Mid-Atlantic Ridge. Due to low signal-to-noise ratios, teleseismic body wave magnitude and long-period surface wave magnitude cannot be confidently determined for small earthquakes of m b < 4. Local magnitude scales are also not useful for these events because the oceanic environment does not allow the propagation of crustal phases. However, regional high-frequency Pn waves from these small- to moderate-size (m b 3–6) earthquakes are well recorded in the equatorial Atlantic region and can be used to assign magnitudes. We measured over 2041 Pn peak amplitudes on vertical records from about 21 stations in northeastern Brazil and 11 stations in western Africa in the distance range of 700–3700 km. We analysed data from 189 events from the global centroid moment tensor catalogue to tie our m b (Pn) scale to M w so that seismic moments can be readily estimated. Pn arrivals show apparent group velocity between 7.9 km s –1 at short ranges (~1000 km) and up to 9.1 km s –1 at 3500 km. The measured peak amplitudes have a frequency between 0.8 and 3 Hz at 1000–1800 km, but at greater distances, 1800–3700 km, they show a remarkably consistent frequency of about 0.8 Hz. The peak amplitude attenuates at a higher rate at short distances (~0.65 magnitude units between 700 and 2000 km) but attenuates at a lower rate at long distances (~0.35 magnitude units between 2000 and 3700 km). The low rate of amplitude decay with distance and nearly constant frequency content of the peak amplitudes suggest that Pn waves propagate efficiently in the lower part of the upper mantle in the equatorial Atlantic Ocean basins. Furthermore, these are important attributes of oceanic Pn waves that can be used to assign magnitude for small- to moderate-size earthquakes in the equatorial mid-Atlantic region. The estimated station corrections correlate well with upper mantle low-velocity anomalies, especially in Brazil.

58 GEOSCIENCES↗

False alarms and the IMS infrasound network: Understanding the factors influencing the creation of false events

The International Monitoring System (IMS) infrasound network has been designed to acquire the necessary data to detect and locate explosions in the atmosphere with a yield equivalent to 1 kiloton of TNT anywhere on Earth. A major associated challenge is the task of automatically processing data from all IMS infrasound stations to identify possible nuclear tests for subsequent review by analysts. This paper is the first attempt to quantify the false alarm rate (FAR) of the IMS network, and in particular to assess how the FAR is affected by the numbers and distributions of detections at each infrasound station. To ensure that the results are sufficiently general, and not dependent entirely on one detection algorithm, the assessment is based on two detection algorithms that can be thought of as end members in their approach to the trade-off between missed detections and false alarms. The results show that the FAR for events formed at only two arrays is extremely high (ranging from 10’s to 100’s of false events per day across the IMS network, depending on the detector tuning). It is further shown that the FAR for events formed at three or more IMS arrays is driven by ocean-generated waves (microbaroms), despite efforts within both detection algorithms for avoiding these signals, indicating that further research into this issue is merited. Overall, the results highlight the challenge of processing data from a globally sparse network of stations to detect and form events. On the basis of these results, it is shown that further work on understanding signal and noise characteristics is needed before attempting to automatically form events detected at only two arrays on the global network. In particular, more work is required to reduce false alarms caused by the detection of microbarom signals.

47 OTHER INSTRUMENTATION↗

Accelerating full waveform inversion via source stacking and cross-correlations

SUMMARY Accurate synthetic seismic wavefields can now be computed in 3-D earth models using the spectral element method (SEM), which helps improve resolution in full waveform global tomography. However, computational costs are still a challenge. These costs can be reduced by implementing a source stacking method, in which multiple earthquake sources are simultaneously triggered in only one teleseismic SEM simulation. One drawback of this approach is the perceived loss of resolution at depth, in particular because high-amplitude fundamental mode surface waves dominate the summed waveforms, without the possibility of windowing and weighting as in conventional waveform tomography. This can be addressed by redefining the cost-function and computing the cross-correlation wavefield between pairs of stations before each inversion iteration. While the Green’s function between the two stations is not reconstructed as well as in the case of ambient noise tomography, where sources are distributed more uniformly around the globe, this is not a drawback, since the same processing is applied to the 3-D synthetics and to the data, and the source parameters are known to a good approximation. By doing so, we can separate time windows with large energy arrivals corresponding to fundamental mode surface waves. This opens the possibility of designing a weighting scheme to bring out the contribution of overtones and body waves. It also makes it possible to balance the contributions of frequently sampled paths versus rarely sampled ones, as in more conventional tomography. Here we present the results of proof of concept testing of such an approach for a synthetic 3-component long period waveform data set (periods longer than 60 s), computed for 273 globally distributed events in a simple toy 3-D radially anisotropic upper mantle model which contains shear wave anomalies at different scales. We compare the results of inversion of 10 000 s long stacked time-series, starting from a 1-D model, using source stacked waveforms and station-pair cross-correlations of these stacked waveforms in the definition of the cost function. We compute the gradient and the Hessian using normal mode perturbation theory, which avoids the problem of cross-talk encountered when forming the gradient using an adjoint approach. We perform inversions with and without realistic noise added and show that the model can be recovered equally well using one or the other cost function. The proposed approach is computationally very efficient. While application to more realistic synthetic data sets is beyond the scope of this paper, as well as to real data, since that requires additional steps to account for such issues as missing data, we illustrate how this methodology can help inform first order questions such as model resolution in the presence of noise, and trade-offs between different physical parameters (anisotropy, attenuation, crustal structure, etc.) that would be computationally very costly to address adequately, when using conventional full waveform tomography based on single-event wavefield computations.

Romanowicz, Barbara↗

Astrometry in two-photon interferometry using an Earth rotation fringe scan

Optical interferometers may not require a phase-stable optical link between the stations if instead sources of quantum-mechanically entangled pairs could be provided to them, enabling long baselines. We developed a new variation of this idea, proposing that photons from two different astronomical sources could be interfered at two decoupled stations. Interference products can then be calculated in post-processing or requiring only a slow, classical connection between stations. In this work, we investigated practical feasibility of this approach. We developed a Bayesian analysis method for the earth rotation fringe scanning technique and showed that in the limit of high signal-to-noise ratio it reproduced the results from a simple Fisher matrix analysis. Here we identify candidate stair pairs in the northern hemisphere, where this technique could be applied. With two telescopes with an effective collecting area of ~ 2 m 2 , we could detect fringing and measure the astrometric separation of the sources at ~100 μas precision in a few hours of observations, in agreement with previous estimates.

47 OTHER INSTRUMENTATION↗

Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy density is determined from the radio pulses at each observer position and is interpolated using a two dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge excess emission components. We found that the spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy – corrected for geometrical effects – is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. Finally we find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Harmonic Analysis of Electric Vehicle Loadings on Distribution System

With the increasing number of Electric Vehicles (EV) in this age, the power system is facing huge challenges of the high penetration rates of EVs charging stations. Therefore, a technical study of the impact of EVs charging on the distribution system is required. This paper is applied with PSCAD software and aimed to analyzing the Total Harmonic Distortion (THD) brought by Electric Vehicles charging stations in power systems. The paper starts with choosing IEEE34 node test feeder as the distribution system, building electric vehicle level two charging battery model and other four different testing scenarios: overhead transmission line and underground cable, industrial area, transformer and photovoltaic (PV) system. Then the statistic method is used to analyze different characteristics of THD in the plug-in transient, plug-out transient and steady-state charging conditions associated with these four scenarios are taken into the analysis. Finally, the factors influencing the THD in different scenarios are found. The analyzing results lead the conclusion of this paper to have constructive suggestions for both Electric Vehicle charging station construction and customers' charging habits.

Xu, Yijun A↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗

Improving EV Charger Resiliency for MW Charging Systems

In this paper, the resiliency of a megawatt-scale EV charging station is investigated. Fault detection and tolerance methodologies are presented, based on monitoring the voltage offsets in DABs and switch-level currents in three-phase inverters, with the goal of maintaining operation at rated power during single faults and at reduced power under multiple fault conditions. To validate the effectiveness of the proposed strategy, simulation results at the rated 1 MW power of the charging station are carried out, followed by controller hardware-in-the-loop (CHIL) experiments on a 250 kW section of the station. The results highlight the feasibility of the integrated fault-tolerant methods for resilient, high-power EV charging infrastructure.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

A Blockchain-Enabled Sustainable Safety Management Framework for Connected Vehicles

The notion of an intelligent transportation system (ITS) aims to boost the performance of transportation networks, which has gained more and more traction in both academic and commercial circles. ITS is a constantly evolving vision that combines cutting-edge transportation approaches with new information, communication, computers, and other technology. ITS should discover consequence routes to enhance the sustainability, safety, and trustworthiness of the entire transportation system utilizing emerging technologies. In this paper, a sustainable safety management framework for connected vehicles is proposed by integrating blockchain. It introduces smart transportation equipment called an AI-enabled vehicle smart device (AVSD) for vehicular communications. AVSD can reduce energy consumption by decreasing the computational costs in vehicular communications. Smart contracts are used to identify vehicles automatically and establish secure communication among vehicles and emergency service stations (ESSs) like hospitals, police stations, and fire stations. The experiment results show that the proposed framework provides a communication environment for sustainable safety and security using the introduced smart transportation device. In conclusion, the proposed blockchain-enabled sustainable safety management framework has the potential to improve safety and sustainability in the transportation industry by creating a secure, decentralized, and transparent platform for managing safety data and promoting safe and sustainable driving behaviors.

42 ENGINEERING↗

SMAC: A soft MAC to reduce control overhead and latency in CDMA-based AMI networks

The utilization of state-of-the-art 3G cellular CDMA technologies in a utility owned AMI network results in a large amount of control traffic relative to data traffic, increases the average packet delay and hence are not an appropriate choice for smart grid distribution applications. Like the CDG, we consider a utility owned cellular like CDMA network for smart grid distribution applications and classify the distribution smart grid data as scheduled data and random data. Also, we propose SMAC protocol, which changes its mode of operation based on the type of the data being collected to reduce the data collection latency and control overhead when compared to 3G cellular CDMA2000 MAC. The reduction in the data collection latency and control overhead aids in increasing the number of smart meters served by a base station within the periodic data collection interval, which further reduces the number of base stations needed by a utility or reduces the bandwidth needed to collect data from all the smart meters. The reduction in the number of base stations and/or the reduction in the data transmission bandwidth reduces the CAPital EXpenditure (CAPEX) and OPerational EXpenditure (OPEX) of the AMI network. Finally, the proposed SMAC protocol is analyzed using markov chain, analytical expressions for average throughput and average packet delay are derived, and simulation results are also provided to verify the analysis.

97 MATHEMATICS AND COMPUTING↗

Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System

This paper presents the development of a scaled four-terminal high-voltage direct current (HVDC) testbed, including hardware structure, communication architecture, and different control schemes. The developed testbed is capable of emulating typical operation scenarios including system start-up, power variation, line contingency, and converter station failure. Some unique scenarios are also developed and demonstrated, such as online control mode transition and station re-commission. In particular, a dc line current control is proposed, through the regulation of a converter station at one terminal. By controlling a dc line current to zero, the transmission line can be opened by using relatively low-cost HVDC disconnects with low current interrupting capability, instead of the more expensive dc circuit breaker. Utilizing the dc line current control, an automatic line current limiting scheme is developed. As a result, when a dc line is overloaded, the line current control will be automatically activated to regulate current within the allowable maximum value.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure mmWave Spectrum Sharing with Autonomous Beam Scheduling for 5G and Beyond

Spectrum Sharing (SS) has seen a renewed set of initiatives in 5G with the availability of shared and unlicensed spectrum bands that can be used by multiple cellular service providers and private cellular networks. Beam based transmission, instead of the traditional sector based transmission in conjunction with the spectrum agility of the 5G New Radio (NR) has brought new opportunities to optimized sharing of spectrum. Currently in the U.S., a centralized Spectrum Access Server (SAS) is used to co-ordinate spectrum sharing among networks sharing the same spectrum band. However, SAS becomes a focal point for security attacks and a performance bottleneck. In addition, SAS relies on an Environmental Sensor Network (ESN), separate from the 5G network. Without trusted spectral occupancy information, false reporting of spectrum sensing data can create sub-optimal and unfair spectrum usage. This paper summarizes our recent research findings in using a decentralized scheme for multiple networks to securely share spectrum with autonomous beam scheduling : 1) A new stochastic network framework based on Lyapunov Optimization approach is developed to optimize scheduling at the base stations; 2) Game theoretic (GT) approach is used to formulate the distributed scheduler; 3) Another distributed scheduler with Q-learning is presented that utilizes the Reinforcement Learning (RL) approach; 4) The performance and convergence rate of these distributed solutions to use shared and unlicensed spectrum are compared with existing solutions. Conditions under which the performance of these schedulers approach the theoretical upper bound, which is the performance possible with no interference among the operators sharing the spectrum, are presented; 5) The ability of a base station to use its own user equipment as sensors, for optimal spectrum sharing with base stations in other operator networks, is demonstrated to be an effective approach.

5G↗

A Compact Gas Liquid Separator for the Spallation Neutron Source Mercury Process Loop

Upgrades at the spallation neutron source (SNS) accelerator at Oak Ridge National Laboratory are underway to double its proton beam power from 1.4 to 2.8 MW. About 2 MW will go to the current first station while the rest will go to the future Second Target Station. The increase of beam power to the first target station is especially challenging for its mercury target. When the short proton beam hits the target, strong pressure waves are generated, causing cavitation erosion and challenging stresses for the target's weld regions. SNS has successfully operated reliably at 1.4 MW by mitigating the pressure wave with the injection of small Helium bubbles into the mercury. To operate reliably at 2 MW, more gas will be injected into mercury to mitigate the pressure wave further. However, the mercury process loop was not originally designed for gas injection, and the accumulation of gas in the pipes is a concern. Due to space constraints, a custom gas liquid separator (GLS) was designed to fit a 90-deg horizontal elbow space in the SNS mercury loop. Simulations and experiments were performed, and a successful design was developed that has the desired efficiency while keeping the pressure losses acceptable.

42 ENGINEERING↗