Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Scanning tunneling microscope tip-induced formation of Bi bilayers on Bi 2 Te 3

We report the formation of Bi(111) bilayer islands and crater structures on Bi 2 Te 3 (111) surfaces induced by voltage pulses from a scanning tunneling microscope tip. Pulses above a threshold voltage (+3 V) produce craters ∼0.5μm in diameter, similar to the size of the tip. Redeposited material self-assembles into a network of atomically ordered islands with a lattice constant identical to the underlying Bi2Te3 surface. The island size monotonically decreases over several micrometers from the pulse site, until the pristine Bi 2 Te 3 surface is recovered. We assign these islands to Bi bilayer based on atomic resolution images, analysis of step heights, and tunneling spectroscopy. Here, the dependence of bilayer formation on bias polarity and the evidence for defect diffusion together suggest a mechanism driven by the interplay of field evaporation and tunneling-current-induced Joule heating.

Bi bilayer↗

A high contrast method of unstained biological samples under a thin carbon film by scanning electron microscopy

The contrast of biological samples in scanning electron microscopy (SEM) is very weak. To examine a biological specimen by SEM, many steps and/or special equipment are required to prepare the sample. Here, we describe a method using an unstained biological sample under a 40 nm carbon film to give a high contrast image, where the image is detected by the secondary electron (SE) signal at a low accelerating voltage of 1.5 kV. Under these conditions, it is hard to detect a direct signal from a biological specimen. The high contrast image is created by the SEs from the lower surface of the thin carbon film. Therefore, the damage to the sample from the electron beam is very low. Our method can be utilized to observe various biological samples of bacteria, viruses, and protein complexes.

60 APPLIED LIFE SCIENCES↗

Plasma membrane characterization, by scanning electron microscopy, of multipotent myoblasts-derived populations sorted using dielectrophoresis

Highlights: •Dielectrophoretic separation/sorting of multipotent cells. •Plasma membrane microvilli structure of C2C12 and fibroblasts by SEM microscopy. •Cell cycle determination by Ki-67 in DEP-sorted cells. •Plasma membrane differences responsible for changes in membrane capacitance. -- Abstract: Multipotent progenitor cells have shown promise for use in biomedical applications and regenerative medicine. The implementation of such cells for clinical application requires a synchronized, phenotypically and/or genotypically, homogenous cell population. Here we have demonstrated the implementation of a biological tag-free dielectrophoretic device used for discrimination of multipotent myoblastic C2C12 model. The multipotent capabilities in differentiation, for these cells, diminishes with higher passage number, so for cultures above 70 passages only a small percentage of cells is able to differentiate into terminal myotubes. In this work we demonstrated that we could recover, above 96% purity, specific cell types from a mixed population of cells at high passage number without any biological tag using dielectrophoresis. The purity of the samples was confirmed by cytometric analysis using the cell specific marker embryonic myosin. To further investigate the dielectric properties of the cell plasma membrane we co-culture C2C12 with similar size, when in suspension, GFP-positive fibroblast as feeder layer. The level of separation between the cell types was above 98% purity which was confirmed by flow cytometry. These levels of separation are assumed to account for cell size and for the plasma membrane morphological differences between C2C12 and fibroblast unrelated to the stages of the cell cycle which was assessed by immunofluorescence staining. Plasma membrane conformational differences were further confirmed by scanning electron microscopy.

60 APPLIED LIFE SCIENCES↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based compositional predictions for a differential scanning calorimetry/thermogravimetric analysis-mass spectrometry system used for heat of vaporization measurements

A Differential Scanning Calorimetry/Thermogravimetric Analysis (DSC/TGA) procedure for determination of Heat of Vaporization (HOV) of fuel and surrogate fuel mixtures has been previously utilized for evaluation of oxygenate impacts on spark ignition fuels. This analysis has been further leveraged with mass spectrometry (MS) to elucidate vapor phase compositional changes during evaporation. In this study we focus on a simple system of three compounds (ethanol, n-hexane, and n-octane) to provide a model-based understanding of the evaporation process under these experimental conditions. An Aspen Plus model was set up to provide liquid and vapor phase concentration predictions during mixture evaporation using the initial mixture composition, and measured temperature and mass loss profiles from DSC/TGA experiments. Agreements between the trends of the MS ion count profiles and model composition predictions provide a degree of validation of this modeling approach that can allow the interpretation and extrapolation of DSC/TGA measurements for more complex fuel mixtures.

33 ADVANCED PROPULSION SYSTEMS↗

Respiratory Motion Changes of Lung Tumors Over the Course of Radiation Therapy Based on Respiration-Correlated Four-Dimensional Computed Tomography Scans

Purpose: To determine whether lung tumor respiratory excursion at simulation is predictive of excursion during radiation and whether phase offsets between tumor and surrogate markers are constant throughout treatment. Methods and Materials: Respiration-correlated CT scans and two rescans (using a Brilliance Big Bore spiral CT simulator; Philips, Inc.) were obtained from 20 patients at simulation. Gross tumor volume (GTV) was contoured on 10 phases of the respiratory cycle, and excursions were calculated. Diaphragm and xyphoid motion were quantified. Phase offsets, DELTAPHI, were calculated for patients with a GTV motion of >3 mm. Interfraction differences in excursions between simulation and rescans and magnitudes of variation in phase offset between fractions were evaluated. Results: Mean GTV excursions at simulation in superior-inferior, anterior-posterior, and medial-lateral directions were 0.67, 0.29, and 0.21 cm, respectively. The magnitude of superior-inferior GTV excursion correlated with tumor location (upper vs. lower lobe, p = 0.011). GTV excursions between simulation and rescan 1 (p = 0.115) and between simulation and rescan 2 (p = 0.071) were stable. Fourteen patients were analyzed for variations in phase offsets. GTV-xyphoid phase offset changed significantly between simulation and rescan 1 (p = 0.007) and simulation and rescan 2 (p = 0.008), with mean DELTAPHI values of 13.2% (rescan 1) and 14.3% (rescan 2). Xyphoid-diaphragm offset changed between simulation and rescan 1 (p = 0.004) and between simulation and rescan 2 (p = 0.012), with mean DELTAPHI values of 14.5% (rescan 1) and 7.6% (rescan 2). Conclusions: Interfraction consistency in tumor excursion suggests tumor excursion at simulation may direct therapy. Significant variations in phase lag between GTV and other anatomic structures throughout treatment have important implications for techniques that rely on surrogate structures to predict tumor motion

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Measurement of the Displacement of Internal Fiducial and Skin Markers During 320-Multislice Computed Tomography Scanning of Breast Cancer

Purpose: To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. Methods and Materials: This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Results: Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 {+-} 0.3 mm, 2.1 {+-} 0.6 mm, and 1.6 {+-} 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 {+-} 0.2 mm in left-right, 1.7 {+-} 0.5 mm in A/P, and 1.1 {+-} 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Conclusions: Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D microstructure reconstruction of casting aluminum alloy based on serial block-face scanning electron microscopy

In this work, the inner microstructure of aluminum-silicon casting alloy was experimentally investigated to reveal the spatial morphology and phase distribution. Its industrial use is as a light-weight structural material. As a powerful three-dimensional (3D) imaging tool at the nano-scale, the serial block-face scanning electron microscopy (SBFSEM) was employed to investigate the specimens. After being 3D reconstructed, the images were visualized to identify preference for several specific intermetallics by quantitative analysis. It was found that these phases have certain relationships in spatial distribution and differences in spatial shapes. In conclusion, the spatial distribution of cracks was studied to understand their propagation and growth.

3D microstructure reconstruction↗

Scanning electron microscopy examination of a Fast Flux Test Facility irradiated U-10Zr fuel cross section clad with HT-9

Observations from a scanning electron microscopy examination of irradiated U-10Zr fuel are presented. The sample studied had a local burnup of 5.7 atom percent and a local inner cladding temperature of 615°C. This examination by electron microscopy has concentrated on producing data relevant to facilitating a better understanding of Zr redistribution in irradiated U-10Zr fuel and on a better understanding of the complex microstructure present in fuel cladding chemical interaction (FCCI) layers. The presented zirconium redistribution data supplements the existing literature by providing a data set at these particular local conditions. In addition to FCCI layers that are readily visible in optical microscopy, this examination has revealed lanthanide degradation of the cladding by what appears to be a grain boundary facilitated pathway. Precipitates of fission produced Pd-lanthanide compounds were observed in the fuel. Furthermore, precipitated regions with elevated Mo and elevated W content were also observed in the HT-9 cladding of this sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The use of the scanning electron microscope in the determination of the mineral composition of Ballachulish slate

Slate is a fine-grained, low-grade metamorphic rock derived from argillaceous sediments or occasionally volcanic ash. Although most slates contain mainly quartz, chlorite and white mica, they vary considerably in their durability, some lasting centuries while others fail after a few years of service. A detailed characterisation of their mineralogy is required for the assessment of performance, and to establish the provenance of a used slate. A combination of methods was used to examine Ballachulish slates; XRD analysis to determine the principal minerals present, XRF analysis to determine the total chemical composition, and scanning electron microscopy to determine the chemical composition of individual minerals. It was found that the white mica in Ballachulish slate is phengite and the chlorite is ripidolite. Feldspar is present as albite and carbonate as ferroan dolomite. Several accessory minerals were also identified, including chloritoid, monzonite and zircon. There was considerable variation in the ratio of the principal minerals, making it impossible to identify used slates by this criterion. Instead, chemical composition of the individual minerals, and possibly key accessory minerals, should be used to determine the provenance of slates.

36 MATERIALS SCIENCE↗

Transmission and scanning electron microscope study on the secondary cyclic hardening behavior of interstitial-free steel

Strain controlled fatigue experiment was employed to evaluate automotive grade interstitial-free ferrite steel. Hundreds of grains were examined by scanning electron microscope under electron channeling contrast image technique of backscattered electron image mode for comprehensive comparison of micrographs with those taken under transmission electron microscope. The cyclic stress responses clearly revealed that rapid hardening occurs at the early stage of cycling as a result of multiplication of dislocations to develop loop patches, dipolar walls and dislocation cells at various total strain amplitudes. After primary rapid hardening, stress responses varied from being saturated to further hardening according to dislocation structure evolution at various strain amplitudes. The fatigue failure was always accompanied with further hardening including secondary hardening. The corresponding dislocation structures with the three types of hardening behaviors are discussed. Once the secondary hardening starts, dislocation cells began to develop along grain boundaries in the low strain region and then extended into grain interiors as strain amplitudes increased and cycling went on. The secondary hardening rates were found to be directly proportional to their strain amplitudes.

36 MATERIALS SCIENCE↗

Scanning electron microscopy, X-ray diffraction and thermal analysis study of the TiH{sub 2} foaming agent

The decomposition of commercially available TiH{sub 2} was investigated while performing different thermal treatments. TiH{sub 2} powder, which is widely used as a foaming agent, was heat treated at 450 Degree-Sign C for various times, from 15 min to 120 min. Scanning electron microscopy (SEM) images of the surfaces at different magnifications were obtained and interpreted. A Bragg-Brentano X-ray diffractometer was used to measure the X-ray diffraction (XRD) spectra on all five samples. A close examination of the diffraction spectra showed that for an as-received sample and samples undergoing the longest thermal treatment (1 and 2 h) these spectra can be explained as deriving from cubic TiH{sub 1.924}, while for the other two samples they can be explained as deriving from tetragonal TiH{sub 1.924}. A constant-unit-cell-volume phase transition between the cubic and tetragonal phases in TiH{sub 2-y}-type compounds had been described in the literature. The unit-cell parameters obtained from measured spectra confirm that within the measurement uncertainty the unit-cell volume is indeed constant in all five samples. Thermo-gravimetry (TG) and differential thermal analysis (DTA) measurements were performed on all the samples, showing that the intensity of the dehydrogenation depends on the previous treatment of the TiH{sub 2}. After the thermal analysis XRD of the samples was performed again and the material was found to exhibit a Ti-like unit cell, but slightly enlarged due to the unreleased hydrogen. - Highlights: Black-Right-Pointing-Pointer TiH{sub 2} samples were cubic or tetragonal TiH{sub 1.924} Black-Right-Pointing-Pointer Onset of the hydrogen release temperature increases with the pre-treatment time. Black-Right-Pointing-Pointer Thermal dehydrogenation for the as-prepared TiH{sub 2} is a three-step process. Black-Right-Pointing-Pointer After thermal analysis 2 residual hydrogen TiH{sub x} phases, close to {alpha}Ti, appeared.

36 MATERIALS SCIENCE↗

Direct comparison between X-ray nanotomography and scanning electron microscopy for the microstructure characterization of a solid oxide fuel cell anode

X-ray computed nanotomography (nano-CT) and scanning electron microscopy (SEM) have been applied to characterize the microstructure of a Solid Oxide Fuel Cell (SOFC) anode. A direct comparison between the results of both methods is conducted on the same region of the microstructure to assess the spatial resolution of the nano-CT microstructure, SEM being taken as a reference. A registration procedure is proposed to find out the position of the SEM image within the nano-CT volume. It involves a second SEM observation, which is taken along an orthogonal direction and gives an estimate reference SEM image position, which is then refined by an automated optimization procedure. This enables an unbiased comparison between the cell porosity morphologies provided by both methods. In the present experiment, nano-CT is shown to underestimate the number of pores smaller than 1 μm and overestimate the size of the pores larger than 1.5 μm. - Highlights: ► X-ray computed nanotomography (nano-CT) and SEM are used to characterize an SOFC anode. ► A methodology is proposed to compare the nano-CT and SEM data on the same region. ► The spatial resolution of the nano-CT data is assessed from that comparison.

36 MATERIALS SCIENCE↗

Monitoring micro-crack healing in an engineered cementitious composite using the environmental scanning electron microscope

Environmental Scanning Electron Microscopy (ESEM) is used to study the origin of micro-crack healing in an Engineered Cementitious Composite (ECC). ESEM images were acquired from ECC specimens cut from pre-cracked, dog-bone samples which then subjected to submerged curing followed by exposure to the natural environment. The mineralogical and chemical compositions of the healing products were determined using the EDX facility in the ESEM. It is shown that the precipitation of calcium carbonate is the main contributor to micro-crack healing at the crack mouth. The healing products initially appeared in an angular rhombohedral morphology which then underwent a discernable transformation in size, shape and surface texture, from relatively flat and smooth to irregular and rough, resembling the texture of the original surface areas surrounding the micro-cracks. It is also shown that exposure to the natural environment, involving intermittent wetting/drying cycles, promotes additional crystal growth, which indicates enhanced self-healing capability in this environment. - Highlights: •ESEM with EDX used to characterize the origin of micro-crack healing in an ECC •Evolution of healing precipitates studied at three specific locations over four weeks •Specimens exposed to laboratory environment, followed by the natural environment •Calcium carbonate is the main contributor to crack healing at the crack mouth. •Outdoor exposure involving intermittent rain promotes additional crystal growth.

36 MATERIALS SCIENCE↗

In-situ investigation of incipient melting in a 319 type Al alloy using laser scanning confocal microscopy

Highlights: • In-situ analysis of incipient melting of ternary eutectic in Al alloy. • Incipient melting occurred in three distinct stages in the eutectic. • Increased heating rate increase rate of liquid film propagation. • Incipient melting transformed initial eutectic structure and caused oxidation. • Study determined incipient melting mechanism for eutectic structures. - Abstract: The modified 319 Al alloy system has been used extensively in precision sand casting of automotive powertrain applications such as engine blocks and cylinder heads, with significant improvement in vehicle fuel efficiency. However, a concern in elevated temperature processing of Al alloys, such as heat treatment and hot working processes, is incipient melting of secondary phases, which is deleterious to mechanical properties. In this study, the laser scanning confocal microscopy (LSCM) technique was used in the analysis of in-situ changes in microstructure as a result of incipient melting. Microstructural analysis was carried out prior to and following elevated temperature exposure in the LSCM using optical microscopy, SEM and EDX. The results suggest that incipient melting of the Al-Al{sub 2}Cu-Al{sub 5}Mg{sub 8}Cu{sub 2}Si{sub 6} ternary eutectic clusters was initiated by the formation of a liquid film which propagated rapidly from the eutectic clusters, coating the Al dendrites in regions adjacent to the eutectic clusters. Following film formation, the ternary eutectic clusters melted completely. Incipient melting also resulted in a localized change in composition in the interdendritic channels as supported by a change in cluster morphology from eutectic to a combination of coarse blocky Al-Cu-Ni and Si particles, and ultra-fine eutectic.

36 MATERIALS SCIENCE↗

Pore structure refinement of cement paste incorporating nanosilica: Study with dual beam scanning electron microscopy/focused ion beam (SEM/FIB)

Highlights: • The modifying effects of nanosilica on pore structure of cement-based composites are investigated. • Dual beam SEM/FIB is implemented to create the 3D pore structure model and calculate porosity and pore size distribution. • The porosity and pore diameter are found to decrease with the inclusion of nanosilica. - Abstract: Pozzolanic materials, micro- and nano-, have been found to improve the durability properties of cement-based materials by refining their pore structure. As a relatively newer material, the modifying effects of nanosilica on pore structure are still inconclusive in the literature. In this study, this was characterized by implementing dual beam SEM/FIB, which can generate 3D models of porous materials for quantitative analysis. The sample is milled by focused ion beam layer-by-layer, and each surface layer is 2D imaged via scanning electron microscopy. Three types of pores – large capillary pore, medium capillary pore and gel pore – can be observed. A 3D pore structure model is then reconstructed from 1000 of these 2D images, from which porosity and pore size distribution can be calculated. Cement pastes incorporating nanosilica and silica fume were compared. The porosity and pore diameter were found to decrease with the inclusion of nanosilica. Furthermore, reduction in capillary pores and subsequent increase in gel pores were also observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A study on the creep behavior of alloy 709 using in-situ scanning electron microscopy

In this research, an experimental evaluation of creep properties of Alloy 709 in the temperature range of 750–850 °C was undertaken. Alloy 709 is a novel austenitic stainless steel with 20% Cr and 25% Ni by wt% that was developed for application in structural components of nuclear power plants. Creep rupture tests were conducted in an in-situ heating-loading and Scanning Electron Microscope (SEM) unit equipped with Electron Backscatter Diffraction (EBSD) detector and Energy Dispersive Spectroscopy (EDS). “Real-time” creep damage mechanisms of Alloy 709 at various stresses and temperatures using a flat, un-notched sample with continuously reducing cross-section is studied so that the failure and maximum creep damage occurred at the center of the sample where the in-situ SEM imaging could be focused. Accelerated creep tests at temperatures and stresses above service conditions were performed by employing multiple blocks of constant loads where the loads were increased once the sample attained constant creep rate, indicating a secondary creep regime. This technique ensures multiple data points can be obtained from the same test, saves the time required for an otherwise long-term creep test and usage of SEM. Further, Coincident Site Lattice (CSL) boundary maps were collected as control maps before testing, and the grain boundaries were observed during the creep test to understand the effect of grain boundary character on the creep damage mechanism. Void growth, grain boundary separation, and sliding were found to be the main creep mechanisms whose rate is dependent on stress and temperature. Failure mechanisms studied on the fracture surface using SEM fractography were correlated to the sample surface observations to create complementary information to better understand the underline creep mechanism of Alloy 709.

36 MATERIALS SCIENCE↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗